Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹57.2 LAccepted-AOC S O MAKHAN SINGH | L1 | Accepted-AOC Award of Contract GURPREET SINGH CONTRACTOR by the committee for the Lower Bidder than others | |
| 2 | L2₹59.8 L+₹2.6 L (4.53%)Rejected-Finance 440 GANDHI CHOWK SADAR BAZAR SHRI MUKATSAR SAHIB | RUPNAGAR | RUPNAGAR | PUNJAB | L2 | Rejected-Finance Higher tender rates from the lowest bidder |
Tender Value
₹50.9 L
EMD Value
₹1.0 L
Closing Date
11 May 2023, 9:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer, Abohar Canal Division Abohar
Executive Engineer, Abohar Canal Division Abohar
Estimate for Reconstruction of V.R Bridge at RD 44810 of Bhagsar Minor
2022_WR_94202_12
E-tender Notice No.32/Abohar Canal Division /2022-
Open Tender
Civil Works - Canal
Item Rate
Sri Muktsar Sahib
Please refer Tender documents.
6 documents required · 6 mandatory
₹2,000
Yes
₹1.0 L
Yes
5 Jun 2023
5 May 2023
11 May 2023
5 May 2023
11 May 2023
5 May 2023
Dismantling of old bridge C.C 1:4:8
Dismantling of old bridge Brick work
Dismantling of old bridge RCC
Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with excavated surplus soil. (Depth upto 3 m)
Laying RCC M-30 with using batching plant, transit mixer and concrete pump in Sub structure, complete as per drawing and Technical specifications. (Height upto 5 m)
Laying RCC M-30 for solid slab superstructure using batching plant, Transit mixer and concrete pump including cenetering & shuttering laid in position complete in all respects. (upto 5 m height)
Providing and laying 75 mm thick Wearing coat consisting of 50 mm thick bituminious concrete and 25 mm thick mastic asphalt including tack coat.
Providing and fixing drainage spout complete as per drawing and Technical specification.
Providing and laying filter media with granular materials/ stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2 of MORTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall/return wall to the full height compacted to a firm condition complete as per drawing and Technical specification.
Providing weep holes in brick masonry/Reinforced concrete abutment, wing wall/return wall with 100 dia PVC pipe, extending through the full width of the structure with slope of 1V:20H towards drawing face complete as per Drawing and Technical Specifications.
Providing and applying two coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ 1 Litre for 2 sqm.
Cement concrete lining 75mm. Thick or less laid manually for irrigation channels, using cement concrete M-15 with cement content 325 kg/cum mixed in an automatic computerized Batching & Mixing Plant and transported to the site in transit mixer
Extra for laying earth as per specifications for Compaction of earth in 20 cm layers, dressing, watering the earth and rolling to specifications. (For ramps)
Hazard maker sign board 300 x 900 mm rectangular as per IRC 67 - 2001 with retro reflective high intensity microprismatic grade sheeting fixed over 2 mm thick aluminium sheet with 25 x 25 x 3 mm angle iron frame supported on a mild steel angle iron post 65 x 65 x 6 mm without cost of definition plate firmly fixed to ground in foundation cconcrete 1:2:4 of size 0.45 x 0.45 x 0.60 m for vertical post complete as per technical clause 801 MORT&H specifications.
Cautionary sign board 600 x 600 x 600 mm triangular as per IRC 67 - 2001 with retro reflective high intensity microprismatic grade sheeting fixed over 2 mm thick aluminium sheet with 25 x 25 x 3 mm angle iron frame supported on a mild steel angle iron post 65 x 65 x 6 mm without cost of definition plate firmly fixed to ground in foundation cconcrete 1:2:4 of size 0.45 x 0.45 x 0.60 m for vertical post complete as per technical clause 801 MORT&H specifications.
Mandatory sign board 600 mm circular as per IRC 67 - 2001 with retro reflective high intensity microprismatic grade sheeting fixed over 2 mm thick aluminium sheet with 25 x 25 x 3 mm angle iron frame supported on a mild steel angle iron post 65 x 65 x 6 mm without cost of definition plate firmly fixed to ground in foundation cconcrete 1:2:4 of size 0.45 x 0.45 x 0.60 m for vertical post complete as per technical clause 801 MORT&H specifications.
Informatory sign board 600 x 600 mm square as per IRC 67 - 2001 with retro reflective high intensity microprismatic grade sheeting fixed over 2 mm thick aluminium sheet with 25 x 25 x 3 mm angle iron frame supported on a mild steel angle iron post 65 x 65 x 6 mm without cost of definition plate firmly fixed to ground in foundation cconcrete 1:2:4 of size 0.45 x 0.45 x 0.60 m for vertical post complete as per technical clause 801 MORT&H specifications.
Providing and Fixing 2 mm corrugated copper plate in expansion joints, complete as per drawing and Technical specifications.
Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply suportsd spans not exceeding 10 m to cater for a horizontal movement up to 20 mm, covered with sealant complete as per drawing and technical specifications.
Dewatering as per Sub estimate closed.
Plain/Reinforced Cement concrete in Substructure complete as per drawings technical specification RCC Grade M-25 (i) high upto 5m (ii) with batching plant, transit mixer and concrete Pump.
PCC 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by viberation i/c curing for 14 days as per drawing and technical specification.
PCC 1:3:6 grade M-15 in open foundation complete as per drawing and technical specification.
Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as drawing and technical specification .(Bridges-Foundation and Sub Structure)
Provision of an Reinforced cement concrete crash barrier at the edge of the Bridge, road, approaches to bridges structure and median,s constructed with M-40 grade concrete, as per dimensions, in the PWD standard drawing No 27-sectiion 4, including form work but excluding steel reinforcement and at location directed by the Engineer, all as specified with concrete mixer
supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as drawing and technical specification (Bridges Super Structure and protection Work Crash Barrier)
Excavation in soil using hydraulic jcb and hydraulic trolley with disposal upto 5.10 Km Pucca including cutting and loading in trolley, trimming bottom and side slopes in accordance with requirements of lines, grades and cross sections and transporting to embankment location within all lifts and lead.
Earthwork for lip cutting for irrigation of channel inclusive of all allowances leads and dressing 0 to 1.5 mtr depth.
Earthwork for lip cutting for irrigation of channel inclusive of all allowances leads and dressing 1.50 to 3.00 mtr depth.
Laying 1st class brick lining 75 mm thick laid in 1:3 CSM over 10 mm thick cement Plaster 1:3 over 12.5 mm thick cement plaster 1:5 over dressed sub grade (for side slopes) including supply carriage, loading and unloading of material from source to site of work complete in all respects as per PWD specification.
Laying 1st class brick on edge coping 229 mm wide and 115 mm thick in cement sand mortar 1:3 complete in all respects as per PWD specification.
Earthwork excavation in foundation, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and side of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within a lead of 30 metres.
Extra allowance for providing templates in curved portions of lining.
Any Other Item
DEEPAK KUMAR CONTRACTOR
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .