Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical TECHNICAL DOCUMENTS CORRECTS |
| 2 | Accepted-Technical | Accepted-Technical TECHNICAL DOCUMENTS CORRECTS |
| 3 | Accepted-Technical | Accepted-Technical TECHNICAL DOCUMENTS CORRECTS |
Tender Value
₹1.7 Cr
EMD Value
₹3.4 L
Closing Date
19 Jan 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE OFFICER
NAGAR PALIKA PARISHAD CHUNAR MIRZAPUR UP
PARED GROUND KE ANDAR 04 ADAD HIGHMAST KA ADHISTHAPAN KARYA TATHA INDOOR KHEL SUVIDHAO KE LIE TENIS COURT, TABLE TENIS COURT, BADMINTAL COURT KA NIRMAD KARYA
2025_DOLBU_1102571_1
376/E-NIVIDA SUCHNA/PDDUNVY/2025-26 DT. 26-12-2025
Open Tender
Civil Works
Percentage
365 days
NAGAR PALIKA PARISHAD CHUNAR MIRZAPUR
Please refer Tender documents.
2 documents required · 2 mandatory
₹16,900
Yes
EXECUTIVE OFFICER
₹3.4 L
Yes
24 Jan 2026
29 Dec 2025
20 Jan 2026
29 Dec 2025
19 Jan 2026
29 Dec 2025
CONSTRUCTION OF HIGHMAST ETC
EARTH WORK IN EXCAVATION BY MECHNICAL MEANS (HYDROLIC EXCAVATOR)/NATURAL MEANS OVER AREAS EXCEEDING 30.0 CM IN DEPTH 1.5 INCH WIDTH AS WELL AS 10 SQM ON PLAN ) INCLUDING GETTING OUT AND DISPOSAL OF EXCAVATED EARTH LEAD UPTO 50M AND LIFT UPTO 1.5 M AS DIRECTED BY ENGINEER -INCHARGE ALL KINDS OF SOIL AS PER SOR.....2.8.1
EXTRA FOR EVERY ADDITIONAL LIFT OF 1.5 M OR PART THEROF IN EXCAVATION/BANKING EXCAVATED OR STACKED MATERIALS. AS PER SOR.....2.26.1
FILLING AVAIBLE EXCAVATED EARTH EARTH (EXCLUDED ROCK) IN TREANCEH PLINTH SIDES OF FOUNDATIONS ETC. IN LAYER NOT EXCEEDING 20CM IN DEPTH. CONSOLIDATING EACH DEPOSITED LAYER BY RAMMING AND WATCHING LEAD UPTO 50M AND LIFT UP TO 1.5M AS PER SOR.....2.25
STONE WORK R.C.R. (1 : 4) FOUNDATION AND SUPERSTRUCTURE
PROVIDING AND LAYING IN POSITION CEMENT CONCRETE OF SPECIFIED GRADE EXCLUDING THE COST OF CENTERING AND SHUTTERING ALL WORK UPTO PLINTH LEVEL 1:4:8 1 CEMENT 4 COARSE SAND (ZONE- III) DERIVED FROM NATURAL SOURCES A GRADED STONE AGGRIGATE 40MM NOMINAL SIZE AS PER SOR....4.1
REINFORCED CEMENT CONCRETE WORK IN BEAMS, SUSPENDED FLOORS ROOFS HAVING SLOPE UPTO 15" LANDINGS BALCOINES SHELVES, AND SPIRAL STAIR CASES ABOVE PLINTH LEVEL UPTO FLOOR FIVE LEVEL, EXCLUDING THE COST OF CONTERING SHUTTERING FINISHING AND REINFORCEMENT WITH 1:1:5:3 CEMENT 1.5 COARSE SAND (ZONE-III) DERIVED FROM NATURAL SOUCES 3 GRADDED STONE AGGRIGATE 20MM NOMINAL SIZE DERIVED FROM NATURAL SOURCES AS PER SOR.....5.3
PROVIDING AND LAYING IN POSITION CEMENT CONCRETE OF SPECIFIED GRADE EXCLUDING THE COST OF CENTERING AND SHUTTERING ALL WORK UPTO PLINTH LEVEL 1:1.5:3 1 CEMENT 1.5 COARSE SAND (ZONE- III) DERIVED FROM NATURAL SOURCES 3 GRADED STONE AGGRIGATE 20MM NOMINAL SIZE DREIVED FROM A NATURAL SOURCES AS PER SOR NO. 5.12 PLINTH BEAM AS PER SOR.....5.1.2
REINFORCED CEMENT CONCRETE WORK IN BEAMS, SUSPENDED FLOORS ROOFS HAVING SLOPE UPTO 15" LANDINGS BALCOINES SHELVES, AND SPIRAL STAIR CASES ABOVE PLINTH LEVEL UPTO FLOOR FIVE LEVEL, EXCLUDING THE COST OF CONTERING SHUTTERING FINISHING AND REINFORCEMENT WITH 1:1:5:3 CEMENT 1.5 COARSE SAND (ZONE-III) DERIVED FROM NATURAL SOUCES 3 GRADDED STONE AGGRIGATE 20MM NOMINAL SIZE DERIVED FROM NATURAL SOURCES BEAM
PROVIDING CORRUGATED G.S. SHEET ROOFING INCLUDING VERTICAL/COVERED SURFACE FIXED WITH POLYMER CONTROL J OR I.G.I. INPUT WASHER OR WITH G.I. INPUT WASHER FIELD WITH WHITE LEAD INCLUDING A COAT OF APRROVED STEEL PRIMER TWO COAT OF APPROVED PAINT ON OVERLAPING OF SHEET COMPLETE (UPTO ANY PATCH IN HORIZONTAL VERTICAL OR CURVED) SURFACESA) EXCLUDING THE COST OF PURLINS REFER AS TREASES AND INCLUDING INTHE SIZE AND SHAPE WHEREAS REQUIRED AS PER SOR.....5.3
STRUCTURAL STEEL WORK RIVETED BOLTED OR WHEELED IN BUILT UP SECTIONS TRUSES AND FRAMED WORK INCLUDING CUTTING HOISTING FIXING IN POSITION AND APPLYING A PRIMING COAT OF APPROVED STEEL PRIMER ALL COMPLETE.
BRICK WORK WITH COMMON BRUNT CLAY F.PS. (NON MODULAR) BRICK OF CLASS DESIGNATION 7.5 IN SUPERSTRUCTURE ABOVE PLINTH LEVEL UPTO FLOOR V LEVEL IN ALL SHAPE AND SIZE IN CEMENT MORTAR 1:6 (1 CEMENT : 6 COARSE SAND )
STEEL REINFORCED FOR R.C.C. WORK INCLUDING SHUTERING CUTTING BENDING PLACING IN POSITION AND BINDING ALL COMPLETE UPTO PLINTH LEVEL . THERMO MECHANICALLY TREATED BARS GRADE FE 500D OR MORE
CENTERING AND SHUTTERING INCLUDING STRUTTING PROPPING ETC AND REMOVAL OF FROM FOR - FOUNDATION FOOTINGS BASE OF COLUMNS ETC FRO MASS CONCRETE
FOUNDATION FOOTINGS BASE OF COLOUMN ETC. FOR MASS CONCRETE
COLUMN PILLERS PIERS ABUTMENTS POST AND STRUTS.
PROVIDNG SAL WOOD WORK IN FRAME OF DOORS WINDOW CLERESTORY WINDOW AND OTHER FRAME WROUGHT FRAMED AND FIXED IN POSITION WITH HOLD FAST LUGS OR WITH DASH FASTNER OF REQUIRED DIA AND LENGTH (HOLD FAST LUGS OR WITH DASH FASTNER SHALL BE PAID SEPERATELY)
LINTELS BEAMS, PLINTH BEAMS, GIRDER BRESSUMERS AND CANTILEVELS WITH WATER PROOF PLY 12MM THICK
CEMENT CONCRETE FLOORING 1:2:4 (1 CEMNET: 2 COARSE SAND :4 GRADDED STONE AGGRIGATE) FINISHED WITH A FLOATING COAT OF NEAT CEMENT INCLUDING FIXING CEMENT SHURY BUT EXCLUDING THE COST OF NOISING OF STEP ETC COMPLETE. 25MM WOODEN PLANKING TOUGUED AND GROOVED IN FLOORING INCLUDING FIXING WITH IRON SCREWS COMPLETE WITH SECOND CLASS TEAK WOOD
FINISHING WITH 12MM CEMENT PLASTER 1:3 (1 CEMENT : 3 COARSE SAND0 FINISHED WITH A FLOATING COAT OF NEAT CEMENT
FINISHING WITH 15MM CEMENT PLASTER 1:3 (1 CEMENT : 3 COARSE SAND0 FINISHED WITH A FLOATING COAT OF NEAT CEMENT ON THE ROUGH SIDE OR HALF BRICK WALL
PAINTING AND DISTERMPERING WITH Ist QUALITY ACRYLIE DISTERMPER (REALY MIXED) HAVING VOC CONTENT LESS THAN 50GMS/LTR OF APPROVED MANUFACTURE OF REQUIRED SHADE AND COLOUR COMPLETE AS PER MANUFACTURE SPECIFICATION TWO OR MORE COAT ON NEW WORK
EXTERIOR WALL 100% PRIMIUM ACRYLIE EMULSION PAINT LAYING VOC LESS THAN 50GMS/LTR AND UV REISTANCE DIRT RESISTANCE EXTERIOR PAINT OF REQUIRED SHADE WITH SILICON ADDITIVES TWO RO MORE COAT APPLIED @1.43 LTR/10GMS
PROVIDNG AND LAYING FILTER MATERIALS UNDER EARTH PITCHING AS PER DRAWING AND TECHNICAL SPECIFICATION
25CM THICK CEMENT CONCRETE CONSISTING OF ONE PART CEMNT 1.5 PARTS APPROVED COARSE SAND AND 3 PART OF APPROVED 13MM GRADED STONE GRITE AND INCLUDING WATER PROFFING MATERIALS.
SUPPLY AND FIXING OF FOLLOWING SIZE OF STEEL CONDUIT ALONG WITH ACCESSORIES IN SURFACE/RECUS PAINTING IN A CASE OF SURFACE SONDUIT OR CUTTING THE WALL AND MAKING GOOD THE SAME IN CASE OF RECESSED CONDUIT AS REQUIRED 20MM DIA 2MM THICK
SUPPLY AND FIXING OF FOLLOWING SIZE OF STEEL CONDUIT ALONG WITH ACCESSORIES IN SURFACE/RECUS PAINTING IN A CASE OF SURFACE SONDUIT OR CUTTING THE WALL AND MAKING GOOD THE SAME IN CASE OF RECESSED CONDUIT AS REQUIRED 25MM DIA 2.5MM THICK
SUPPLY AND FIXING OF METAL BOX OF FOLLOWING SIZE (NOMINAL SIZE) ON SURFACE OR IN RECES WITH SUITABLE SIZE OF PHENOLIC LAMINATED SHEET COVER IN FRONT INCLUDING PAINTING ETC AS REQUIRED 200MM X 150MM X 75MM
SUPPLY AND FIXING OF METAL BOX OF FOLLOWING SIZE (NOMINAL SIZE) ON SURFACE OR IN RECES WITH SUITABLE SIZE OF PHENOLIC LAMINATED SHEET COVER IN FRONT INCLUDING PAINTING ETC AS REQUIRED 150MM X 75MM X 60MM
SUPPLY AND FIXING OF FOLLOWING MODULAR SWITCH /SOCKET ON THE EXISTING MODULAR PLATE ETC AS REQUIRED. 2 WAY 5/6 A SWITCH
SUPPLY AND FIXING OF FOLLOWING MODULAR SWITCH /SOCKET ON THE EXISTING MODULAR PLATE ETC AS REQUIRED. 3PIN 5/6 A SOCKET OUTLET
SUPPLY AND FIXING OF FOLLOWING MODULAR SWITCH /SOCKET ON THE EXISTING MODULAR PLATE ETC AS REQUIRED. 6PIN 15/6 A SOCKET OUTLET
SUPPLY AND FIXING OF TWO MODULE STEPPED TYPE OF ELECTRONIC FAN REGULATER ON THE EXISTING MODULAR PLATE ETC AS REQUIRED
SUPPLY AND FIXING OF MODULAR BLANKING PLATE ON THE EXISTING MODULAR PLATE AND SWITCH BOX EXCLUDING MODULAR PLATE AS REQUIRED
SUPPLY AND FIXING OF FOLLOWING SIZE/MODULES GI BOX ALONT WITH MODULAR BASE AND COVER PLATE FOR MDDULAR SWITCHES IN RECESS ETC. AS REQUIRED 6 MODULE (200MM X 75MM)
SUPPLY AND FIXING OF FOLLOWING SIZE/MODULES GI BOX ALONT WITH MODULAR BASE AND COVER PLATE FOR MDDULAR SWITCHES IN RECESS ETC. AS REQUIRED 4 MODULE (125MM X 75MM)
SUPPLYING CAPACITOR TYPE CEILDING FAN COMPLETE WITH DOWN ROADS BLADES SHACKLE CANOPIES ETC FOR OPERATION ON 230V 50 CYCLES, SINGLE PHASE AC SUPPLY CONFIRMING TO ISS 374-1979 AND WITH LATEST AMENDMENT 2 YEAR MANUFACTURE WARANTY 48" SWEEP (1200MM) REGULAR MODEL
LED MODULAR DOWN LIGHT 2' X 2' /1' X 4' 42-55 W
WIRING FOR LIGHT POINT/FAN POINT WITH 1.5 SQ. MM FRLS PVC INSULATED COPPER CONDUCTOR SINGLE CORE CABLE IN SURFACE /RECESES STEEL CONDUIT WITH MODULAR SWITCH MODULAR PLATE SUITABLE GI BOX AND EARTHING THE POINT WITH 1.5 SQ. MM FRLS PVC INSULATED COPPER CONDUCTOR SINGLE CORE CABLE ETC AS REQUIRED. GROUP A
WIRING FOR LIGHT POINT/FAN POINT WITH 1.5 SQ. MM FRLS PVC INSULATED COPPER CONDUCTOR SINGLE CORE CABLE IN SURFACE /RECESES STEEL CONDUIT WITH MODULAR SWITCH MODULAR PLATE SUITABLE GI BOX AND EARTHING THE POINT WITH 1.5 SQ. MM FRLS PVC INSULATED COPPER CONDUCTOR SINGLE CORE CABLE ETC AS REQUIRED. GROUP B
2.5 MM COPPER WIRE POLY / HAVELLS
4 MM COPPER WIRE POLY / HAVELLS
SUPPLYING AND INSTALATION OF RESIDUAL CURENT CIRCUIT BREAKER (RCCB) 63AMP 2 POLE SENSITIVITY 100MM 415 VOLT AC COMPLETE WITH ALL ACCESSORIES SUTABLE TO FIX ON A DIN-BAR ETC AS REQUIRED
SUPPLY AND FIXING OF HOLONIX SOLAR STREET LIGHT 60 WATT
1 % Consultancy Charge
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.95 MB
BOQ_2032946.xls
BOQ • 0.24 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .