Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.3 LAccepted-AOC | L1 | Accepted-AOC Accepted being lowest on 08 Mar 2021 | |
| 2 | L2₹19.8 L+₹51,562.75 (2.68%)Rejected-Finance H NO 273 VPO SURHERA WEST DELHI 110043 | WEST DELHI | DELHI | 110043 | L2 | Rejected-Finance Rejected | |
| 3 | L3₹19.9 L+₹60,540.95 (3.14%)Rejected-Finance | L3 | Rejected-Finance Rejected | |
| 4 | L4₹20.1 L+₹82,653.80 (4.29%)Rejected-Finance | L4 | Rejected-Finance Rejected | |
| 5 | L5₹20.7 L+₹1.4 L (7.50%)Rejected-Finance | L5 | Rejected-Finance Rejected |
Tender Value
₹21 L
EMD Value
₹42,000
Closing Date
1 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Faridkot
Garrison Engineer, Faridkot-151203 Punjab 01639-264982
Provn of certain sanctioned works under AGE B/R (P-1) and AGE E/M at Faridkot Mil Stn
2021_MES_413025_2
GE FRD-71/2020-21
Open Tender
Civil Works
Item Rate
180 days
Faridkot Mil Stn
Class E Category a i
8 documents required · 8 mandatory
₹500
Yes
GE Faridkot
₹42,000
Yes
8 Mar 2021
8 Feb 2021
3 Mar 2021
8 Feb 2021
1 Mar 2021
15 Feb 2021
60 days
Amount
Surface excavation in soft/loose soil not exceeding 30 cm deep and averaging 15 cm deep and getting out complete all as specified and directed by Engr-In-Charge.
Demolition of brick (laid flat or on edge) or brick tiles laid dry and pointed in berms, floors, channels, kerbs, aprons etc complete all as specified and directed by Engr-In-Charge.
M&L for hard core of broken stone or boulders of guage n.exc 63mm deposited spread and levelled in layer n.exc 15cm thick watered and well rammed to true surfacescomplete all as specified and directed by Engr-In-Charge.
M & L for 100mm thick plain cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in sub base complete all as specified and directed by Engr-In-Charge.
M & L for sand cushioning 25mm thick filling under floors or in foundation watering and consolidated complete all as specified and directed by Engineer-in-Charge.
M&L machine pressed precast concrete interlocking paver block of shape and size as approved by GE confirming to IS 15658-2006 of 80mm thickness, M-40 Grade, with grey cement and pigment, complete all as specified and directed by Engineer-in-Charge.
M&L for (Factory casted) Pre-cast cement concrete 1:3:6 type B-1 using 20mm graded stone aggregate as in kerb stone of approximate any size as directed by Engineer-in-Charge including form work with plain fair faces, including chamfering, weathering, throating etc set in cement mortar 1:6 with joints to match for path edging etc; embedded in position including all necessary excavation, tamping ground around blocks and removal of rubbish/surplus soil etc complete all s diirected complete all as specified and directed by Engineer in Charge.
S&F plastic speed breaker (ABS Material) of size L 250mm x W 350mm x H 50mm with four highly reflective reflectors moulded in PMMA material are welded with ABS plate through ultrasonic welding process and than fixed on to the speed breakers so that dust and water cannot touch reflectors inside and thus it maintains its reflectivity for a long time complete all as specified and directed by Engineer-in-Charge. Make : DArk Eye (Cat Part No. DA-1006) or equivalent of International Wire Product / Surya Enterprises / Greenlite / TATA BP
S&F MS round delineator 50mm dia and 900mm long having 2 Nos. 100mm dia highly reflective reflector made of PMMA and mounted on MS pipe of 50mm duly powder coated anti rust and anti theft steel net available in Red / White or Yellow and embedding the same in PCC 1:2:4 type B1 using 20mm graded stone aggregate complete all as specified and directed by Engineer-in-Charge. Make : International Wire Products or equivalent in Dark Eye (DA-952) / Surya Enterprises / Greenlite / TATA BP Note : Size of PCC block for embedding delineator shall be 10cm x 10cm x 15cm and cost of the same is deemed to be included int he unit rate of respect item of BOQ
S&F solar cat eye (Road stud) of red/yellow colour aluminium alloy body with suitable battery, rechargable automatically by sun light etc fixed on road by mean of adhesive complete all as specified and directed by Engineer-in- charge.
M & L for painting lines, dashes, arrows, letters etc on road / pavement and like using thermoplastic road marking paint, for a dry film 2.5mm thick @ 5 Kg per Sqm. Binder contents 18.0% min, glass beads 30-40%, Titanium, Dioxide 1.0% min, CaCos and inert fillers 42.0 max, including preparation of old / new surface complete all as specified and directed by Engineer-in-Charge. Make : Reliance / Shivalik / Swastic
Demolition of cement concrete unreinforced concrete in ground floor and paving n exc 15cm thick (below or above ground level etc complete all as specified and directed by Engr-In-Charge.
S &F Vitrified ceramic tiles light shade 10 mm thick (square/rectangular) polished area of each tile not exceeding 0.36 sqm in floors etc set and jointed in neat cement slurry over & including 15 mm thick screed in cement mortar (1:4) and pointed in white cement to match the colour of tiles complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster on brick or stone wall etc including raking out of joints, hacking for keys and scrubbing down with water etc and removal of debris upto a distance upto 50m complete all as specified and directed by Engr-In-Charge.
M & L Vitrified Ceramic tiles, coloured light shade in skirting/risers/dado etc, set and jointed in cement slurry over & including 10 mm thick rendering in cement mortar (1:4) and pointed in white cement with pigment to match the colour of tiles complete all as specified and directed by Engr-In-Charge.
S&F Solid PVC Wall Lining consisting of 5mm thick wood grain printed PVC sheet having beading/border on top and on joints inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and directed by Engineer-in-Charge. Note:- If any minor electric fittings and fixtures disturbed there will be match and fixed as existing.
S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and directed by Engineer-in-Charge.
Surface dressing including Trimming of Natural ground, rough excavated surfaces and filled up area to remove vegetation and/or small inequalities not exceeding 15 cm deep complete all as specified and directed by Engr-In-Charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out including baling/pumping /dewatering(if required) of water complete all as specified and directed by Engr-In-Charge.
Returning, filling in trenches including spreading, leveling watering and well ramming in layers not exceeding 25cm complete all as specified and directed by Engr-In-Charge.
Removing of surplus soil not exceeding 200 m and deposited where directed at a level not exceeding 1.50m above the starting point complete all as specified and directed by Engr-In-Charge.
M&L for PCC 1:4:8 type D2 40mm stone aggregate filling mass concrete in foundation complete all as specified and directed by Engr-In-Charge.
Material and labour for providing Reinforced Cement Concrete (1:1.5:3) type A1 using 20 mm graded aggregate as in foundation including rafts, footings, foundation beams, plinth beams, bases of columns etc complete all as specified and directed by Engr-In-Charge.
Material and labour for providing Reinforced Cement Concrete (1:1.5:3) type A1 using 20 mm graded aggregate as in Columns, pillars, piers, posts and struts complete all as specified and directed by Engr-In-Charge.
Material and labour for providing Reinforced Cement Concrete (1:1.5:3) type A1 using 20 mm graded aggregate as in beams, cantilever, lintels over 1.5 m complete all as specified and directed by Engr-In-Charge.
Material and labour for providing Reinforced Cement Concrete (1:1.5:3) type A1 using 20 mm graded aggregate as in slabs supported on walls, beams and columns in floor, roof, landing, balcknies, conopies, decks, slab and in shelves and like complete all as specified and directed by Engr-In-Charge.
M & L Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; rough finished vertical or to batter complete all as specified and directed by Engr-In-Charge.
M & L Formwork to sides of pillars, posts, struts, piers, columns and stanchions rough finished vertical or to batter complete all as specified and directed by Engr-In-Charge.
M & L formwork to sides and soffits of floor or roof beams, beam hunching, girders, lintels, cantlievers, shelves including supports, etc for rough finished flat surfaces of concrete complete all as specified and directed by Engr-In-Charge.
M & L formwork to soffits of suspended slabs such as roof slabs, floor slabs, la ndings and similar work; not exceeding 200 mm thick (Horizontal or slopping) for rough finished flat surfaces of concrete complete all as specified and directed by Engr-In-Charge.
Use and waste of form work to edges of concrete flats, slabs etc including fair finished surfaces complete all as specified and directed by Engineer in Charge.
Material and labour for 10 mm dia and over TMT bars, cut to length bend to shape as required including cranking, hooking etc and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed by Engr-In-Charge.
All as per above item here-in-before but 6 to 8 mm dia complete all as specified and directed by Engr-In-Charge.
M&L for hard core of broken brick of guage n.exc 63mm deposited spread and levelled in layer n.exc 15cm thick watered and well rammed to true surfaces as s complete all as specified and directed by Engr-In-Charge.
Material and labour for providing 75 mm thick cement concrete (1:3:6) type C2 using 40mm graded aggregate as in plinth protection surfaces even and smooth without using extra cement including provision of construction joints complete all as specified and directed by Engr-In-Charge.
M&L for 75mm thick cement concrete 1:4:8, type D-2 using 40mm graded stone aggregate as in sub floors, sub base, floor and pavings etc complete all as specified and directed by Engineer in Charge.
M&L for 40mm thick cement concrete 1:2:4, type B-1 using 20mm graded stone aggregate as in sub floors, sub base, floor and pavings etc complete all as specified and directed by Engineer in Charge.
M&L for glass dividing strips 3mm thick 38mm width in repair inserted in position complete all as specified and directed by Engineer in Charge.
Material and labour for steel framed work such as grills, gratings, etc, with ends of bars shouldered and or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walkways; railings; frame work of water tanks and similar work conforming to Fe-290. Gde-E-165 complete all as specified and directed by Engr-In-Charge.
Material and labour for preparation of new steel surfaces of any description, not otherwise described over 10cmwidth or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-In-Charge.
M&L for brick work with fly ash bricks of old size straight or curved on plan exceeding 6m mean radius with old size bricks in wall built in cement mortar (1:6) complete all as specified and directed by Engr-In-Charge.
M&L for 5mm thick rough cast plaster over 10mm thick rendering in cement mortar (1:4) on fair faces of brick work or concrete surfaces rough cast mixture shall consist of crushed stone or fine gravel aggregate, coarse sand & cement in the ratio of 1:1:1 over rendering coat complete all as specified and directed by Engineer in Charge.
M & L for rendering 15mm thick in cement mortar (1:4) on brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed by Engr-In-Charge.
M & L for rendering 15mm thick in cement mortar (1:6) on brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed by Engr-In-Charge.
M & L for rendering 5mm thick in cement mortar (1:3) on brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed by Engr-In-Charge.
M & L for rendering 5mm thick in cement mortar (1:3) on brick work or concrete surfaces of ceiling finished even and smooth without using extra cement complete all as specified and directed by Engr-In-Charge.
M & L for preparation of newly rough cast plastered surfaces of wall and applying two coats of cement base paint complete all as specified and directed by Engr-In-Charge.
M & L for preparation of newly plastered /RCC surfaces of wall and applying two coats of cement base paint complete all as specified and directed by Engr-In-Charge.
M&L Preparation of new surfaces plastered or unplastered and applying three coat of white wash on wall complete all as specified and directed by Engr -in - charge.
M&L Preparation of new surfaces plastered or unplastered and applying three coat of white wash on ceiling complete all as specified and directed by Engr -in - charge.
S&F rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 1000 Ltr capacity hoisted and fixed in position including PTMT high pressure, with polythene float and fly nut screwed for 20mm bore iron pipe complete all as specified and directed by Engineer in Charge.
S&F Mild Steel galvanised tubing medium grade 20mm bore with all fitting and fixed to wall with hooks, ceiling and laid in floor complete all as specified and directed by Engr-In-Charge.
S&F Cast copper alloy stop valve/angle ball screwed down for high pressure with crutch or butter fly handle screwed both ends for iron pipe of 20mm bore complete all as specified and directed by Engr-In-Charge.
S&F Mild Steel galvanised tubing medium grade 15mm bore with all fitting and fixed to wall with hooks, ceiling and laid in floor complete all as specified and directed by Engr-In-Charge.
S&F bib tap cast copper alloy, CP brass with crutch or butter fly handle, chromium plated screwed down screwed for 15mm bore pipe & fixed of approved make complete all as specified and directed by Engr-In-Charge.
S & F Hollow PVC wall lining interlocking type 7mm thick, plain/ coloured fitted into the wall with PVC rawal plugs and steel screws including fillet to edges and corners as per manufacturer instruction complete all as specified and directed by Engineer in Charge. (Note : If any minor electrical fitting and fixtures disturbed there in will be match and fixed as existing).
S&F Gypsum board 7mm thick in ceiling fixed with screw as per manufacturer's instructions, plain / coloured fixed on steel snap grid (Powder coated bottom side) with 'T' and 'L' (26mm x 24mm x 1mm thick) size of grid 600mm x 600mm placed in ceiling 'L' section fixed with wall using PVC rawl plugs and steel screws @ 600mm centre to centre and suspended / provided 14 gauge (2mm) galvanized bars @ 1.00 Sqm hanging arrangements and level including adjustable clips all as specified and directed. in clause 10.38 of MES Sechudle Part-I complete all as specified and directed by Engineer in Charge. (Note : If any minor electrical fittings and fixture dusturbed there in will be match and fixed as existing)
Taking down carefully existing aluminium/copper point wiring light, fan socket or power bell complete with fitting such as switches, sockets, ceiling roses, pendants batten holders regulators socket, call bells and making good to the disturbed surfaces of walls, matching the colour with existing surface complete all as specified and directed by Engineer in Charge.
Point wiring complete with ISI marked 1.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade FRLS with multistranded copper conductor drawn through concealed/surface in wall / roof/ ceiling surface and its accessories on the surface etc including PVC rigid concealed conduit suitable size with all acessories such as bend, reducers, MS hooks, MS junction boxes, 2mm thick galvanized steel pressed sunken terminal boxes of suitable sizes for mounting of switches, sockets, fan regulators etc covered with 2.8mm thick plastic laminate Hylem top cover of required colour fixed with brass screws and cup washers painting terminal boxes inside and outside with one coat red oxide primer including fixing and 1.5 Sqmm copper conductor as earth continuity to connect common earth dolly for One light point/fan point/exhaust fan point /call bell point to be controlled by one number one way switch complete all as specified and directed by Engineer in Charge.
All as per item No 59 here in before but one three pin socket outlet 5 Amps on the same board with other switches complete all as specified and directed by Engineer in Charge.
All as per item No 59 here in before but one 3 pin, 5A switch socket outlet point on independent board complete all as specified and directed by Engineer in Charge.
S & F of LED false ceiling (panel) light fitting 28/34/36W, (2x2 feet) 230 volts, environmental friendly, new generation, aesthetically designed, ultra modern recess mounting luminaire with high prightness SMD LEDs as light source and including connections up with copper conductor wire with suitable size as per spcification and directed by Engineer-in-Charge. (Make : Havells Cat Part No. PLUTONEO2X2 PLR28W LED840S or equivalent in Bajaj/Philips)
S&F switch Piano type single pole one way 5/6 Amp, 230 Volt AC supply complete all as specified and directed by Engineer in Charge.
S&F socket two in one, 3 Pin 5 Amps 230 Volt AC supply, complete all as specified and directed by Engineer in Charge.
Refixing only Exhaust fan complete with accessories any size, three core copper flexible wire not less than 0.5 mtr for connecting from ceiling rose/ connector to exhaust fan any size complete all as specified and directed by Engineer in Charge.
Supply, install and commissioning of hi wall-split type AC units indoor/outdoor air conditioner complete with cordless remote control unit and within built air ioniser and plazma filter for better indoor air quality with minimum BEE approved, not less than BEE 3 star rating, electric driven single phase 230 volts, AC 50 Hz, R-410A refrigerant of capacity 2.0 tone, including copper piping of adequatee size and required length as directed duly insulated with suitable insulating material e.g. glass wool, plywood, moulded thermocoal etc complete with steel bracket for condensing unit and copper cable of suitable size for making electric connection indluding necessary PCC in 1:2:4 type B1 using 20mm graded stone aggregate as in foundation, platform, form work and angle iron work, steel frame made with angle iron size as directed by Engineer-in-Charge. Note : The quoted rate shall be deemed to be inclusive of supply and fixing set of bracket inluding nuts and bolts for outdoor unit complete.
S&F voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 150 V to 285 V with output voltage stabilized at 230 volt with accurcy of + 2.5% and of capacity 5 KVA complete all as specified and directed by Engineer in Charge.
S&F sheet metal enclosure DB Plug metal clad SP & N with a 2 pin earth plug and socket with MCB SP 'C' series, 10 KA 20 Amps suitable for working on 230 volts AC complete all as specified & directed by Engineer-in-Charge.
S&F sub-main wiring with two single core cables PVC insulated and un-sheathed 6 sqmm (Nominal Area) FRLS stranded copper conductor drawn into PVC concealed conduit, including one run 6 Sqmm (Nominal Area) copper cable as earth continuity conductor including necessary connections, PVC flexible pipes are used in panel board while connecting the cable complete all as specified and directed by Engineer-in-Charge. Note : Two runs of 6 Sqmm single core cable and one run of 6 sqmm copper wire earth continuty conductor and conduit with fittings shall be measured as one length.
Point wiring complete with 1100 volts grade FRLS insulated unsheathed cable of copper conductor cable multi stranded of size 2.5 Sqmm single core drawing through concealed conduit terminated with steel pressed sunken terminal boxes and 2.5 sqmm PVC stranded copper conductor insulated unseathed stranded (Green colour) connected to common earth point dolly for earth plug & socket with MCB complete all as specified and directed by Engineer in Charge.
Supply, installation, commissioning and testing water storage heater (geyser) vertical type of 25 ltr capacity, ultathick stainless steel superior 304 Gde PUF insulation thermostate, thermal cut off, 1PX4 multifunctional safety valve technology, feroglas dry powder coating finish, suitable for to operate / function on AC 220 V, single phase having heating element of 2 KW capacity and high thermal cut-out, energy saving BEE 3 star rating or above including fixed along walls including grouting fastening & fixing (04 Nos) 16mm dia 150mm long GI bolts & nuts, washers and connecting up inlet/ outlet with cold water PVC connection pipes and electric connections cable cord min 1.50m length with copper conductor cable 3 core and 3 pin plug 15/16 Amp, including making good the disturbed surfaces matching with existing complete all as specified and directed by the Engr-in-charge. Make :- Havells, Bajaj, Surya, V Gaurd, Crompton Greaves, Racold, Jaquar & Co Pvt Ltd Note : PVC connection will be measured & paid separately.
S&F stop valves cast copper alloy fancy type, chormium plated with long shank and cup (concealed type ), with crutch or butterfly handle screwed for iron pipe or brass ferrule for 15mm bore pipe fixed complete all as specified and directed by Engineer-in-Charge.
Supply & fixing PVC connections 15mm size with PTMT nuts of length 300mm suitable for (Hot & cold pipe) application complete all as specified & directed by Engineer-in-charge.
Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth; or n exc 10 Sqm on plan and n exc 1.5 m in depth for foundations of poles, struts, stays etc. or laying underground cable etc. in soft/loose soil, & getting out including taking out old brick or precast cable cover for reuse complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, excavated soil including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed by Engineer-in-Charge
Removal of excavated surplus soil to a distance n.exc 50m and depositing where directed at level not exceeding 1.5 m above the starting point complete all as specified & directed by Engineer-in-charge
M & L for sand cushioning with dry coarse sand to under ground cable 23 cm thick, 8 cm thick below the cable and 15 cm thick after laying the cable complete all as specified and directed by Engineer-in-Charge. Note : Thickness after punning shall be considered for payment.
M & L for brick protection with old size sub class 'B' bricks laid flat , length of bricks across the route of underground cable complete all as specified and directed by Engineer-in-Charge.
Supply, fixing and testing LED flood light fitting of 45 Watt fitted on 4 to 9 meter high octagonal pole including LED lamps complete with body robust, corrosion, resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die cast aluminium alloy. The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP-65 protection as per IS-10322-1982 (Part-I) with latest amendments and input voltage range 140-300V, AC, frequency 50-60 Hz, PF should be more than 0.9 with total harmonic distoration THD (I) less than 15%, cool white colour and lamp starting time should not be more than 10 second, Fittings should be provided with 10 KV surge protection. Driver should be constant current constant voltage driver. Driver should have high voltage withstanding capacity upto 300V, AC. Driver should also have double phase protection, no load, open circuit and short circuit protection. LED light fittings should be suitable for ambient temperature from - 10 degree centrigrade to 50 degree centigrade and humidity level 10% to 90% RH. Covers should be polycarbonate/ toughened glass to ensure minimum IP 65 degree protection cover should not degrade due to heating and ageing. The efficient of LED luminaries system shall be more than 85 lumens per watt and must be certified by LM-79 test report complete all as specified and directed by Engineer-in-Charge. Make: Philips, Wipro, Bentech, Jaquar & Co Pvt Ltd, Syska LED Lights Pvt Ltd (Syska), Halonix technologies Pvt Ltd (Halonix), C & S Electric Ltd, Havells Note :- (a) Bidder shall submit test report of LED street light fitting from accredited test laboratory for LM-79 (b) Bidder has to furnish a replacement warranty of 05 years for LED light fittings complete including lamps from the date of completion of CA. The product will be replaced free of cost in the following cases : - (i) Manufacturing defects, (ii) Failure due to mechanical and electrical impact, (iii) Drop in lumen (or lux at 1m) below 90% of claimed values of lumen (or lux at 1m) of the LED/ luminairies. (c) All LED light luminaire must meet the provision laid down in IS-16101, 16102 Part-I/II, 16103 Part-I, 16104, 16105, 16106, 16108/2012 and 15885 Part-II/ Section 13 (d) scope of work shall include supply and fixing street light fittings on poles which includes needful T & P and required accessories etc if any, complete including making connection, testing etc complete. No extra payment is admissible on these account. Note: Every light fitting will be warranty 5 years after completion of CA and replacement/defects as applicable should be complied/rectified within 7 days .
Supply & fixing street light bracket fabricated made out of GI Tubing light grade 40mm bore bend to the shape as directed and of length 1.0 mtr complete with mounting MS clamp of flat iron 45 x 5 mm of suitable length 04 pairs including nut bolts etc of suitable size and painting to MS clamps with two coats of aluminum paint over one coat of red oxide metal primer complete all as specified and directed by the engineer in charge.
S&F pole mounted PVC/FRP pole box with clamps fixed on pole including provn of 32 Amps 4 way connector with nuts bolts, clamps including end termination of 02 Nos for XLPE cable and provn of 01xMCB SP 6 to 32 Amps complete all as specified and directed by the engineer in charge. Make: Hansel/Sintex
Supply & fixing PVC insulated multi stranded aluminium conductor PVC cable sheathed 4 sqmm two core and making connection of street light fittings with overhead lines/ UG cable complete all as specified and directed by Engineer-in-Charge.
Boring/Drilling ( horizontally) manually under existing road ( maximum 10 M in width) suitable for passing GI tubing of 40 to 100 mm bore complete all as specified and directed by the engineer in charge.
Supply and fix in repair Galvanised mild steel pipe/tubing of size 40 mm bore dia, light grade complete with all fittings, laid in trenches / under roads, drain, paths, fixed to poles / walls with mild steel clamps, bolts, nuts and washers complete all as specified of following bore and as directed by Engineer-in-Charge. Note : Excavation & earth work, Mild steel clamps, bolts, nuts and washers shall be measured and paid separately)
Supply and laying XLPE insulated stranded and PVC sheathed heavy duty armoured electric cable with stranded aluminium conductor 1100 Volts grade confirming to IS - 7098 cross sectional area 10 Sqmm 4 core including thimbles / lugs with and including passing through pipe along wall, under road crossing / Nallah / under floor etc complete all as specified and directed by Engineer in Charge. (Note : Earth work, sand cushioning, GI pipe protection and brick protection to be measured and paid seperately).
S & F Mild steel cross arms, bracings, stiffeners, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed complete all as specified and directed by Engr-in-Charge.
Supply, fixing and testing LED flood light fitting of 160 Watt fitted on 4 to 9 meter high octagonal pole including LED lamps complete with body robust, corrosion, resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die cast aluminium alloy. The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP-65 protection as per IS-10322-1982 (Part-I) with latest amendments and input voltage range 140-300V, AC, frequency 50-60 Hz, PF should be more than 0.9 with total harmonic distoration THD (I) less than 15%, cool white colour and lamp starting time should not be more than 10 second, Fittings should be provided with 10 KV surge protection. Driver should be constant current constant voltage driver. Driver should have high voltage withstanding capacity upto 300V, AC. Driver should also have double phase protection, no load, open circuit and short circuit protection. LED light fittings should be suitable for ambient temperature from - 10 degree centrigrade to 50 degree centigrade and humidity level 10% to 90% RH. Covers should be polycarbonate/ toughened glass to ensure minimum IP 65 degree protection cover should not degrade due to heating and ageing. The efficient of LED luminaries system shall be more than 85 lumens per watt and must be certified by LM-79 test report complete all as specified and directed by Engineer-in-Charge. Make: Philips, Wipro, Bentech, Jaquar & Co Pvt Ltd, Syska LED Lights Pvt Ltd (Syska), Halonix technologies Pvt Ltd (Halonix), C & S Electric Ltd, Havells Note :- (a) Bidder shall submit test report of LED street light fitting from accredited test laboratory for LM-79 (b) Bidder has to furnish a replacement warranty of 05 years for LED light fittings complete including lamps from the date of completion of CA. The product will be replaced free of cost in the following cases : - (i) Manufacturing defects, (ii) Failure due to mechanical and electrical impact, (iii) Drop in lumen (or lux at 1m) below 90% of claimed values of lumen (or lux at 1m) of the LED/ luminairies. (c) All LED light luminaire must meet the provision laid down in IS-16101, 16102 Part-I/II, 16103 Part-I, 16104, 16105, 16106, 16108/2012 and 15885 Part-II/ Section 13 (d) scope of work shall include supply and fixing street light fittings on poles which includes needful T & P and required accessories etc if any, complete including making connection, testing etc complete. No extra payment is admissible on these account. Note: Every light fitting will be warranty 5 years after completion of CA and replacement/defects as applicable should be complied/rectified within 7 days .
M&L for Cutting holes into through brick walls built in cement mortar depth of embedded portion of hold fast or lugs measured from the face of the jamb into wall exc half brick wall but n.exc one brick wall for in surting hold fasts and making good as required superficial area complete all as specified and directed by Engineer-in- charge.
M & L for cement Concrete (1:3:6) type C-1 using 20mm graded stone aggregate as in coping, bed block of hold fast and splash stone complete all as specified and directed by Engr-In-Charge.
M & L for band, straps, supports or stays for rain water, ventilating pipes, inlcuidng bolts, if required; hooks (stays), heavy , for large gates; hook and pintle hinges; large hasp and staples; chains; hand made sliding bolts; clamps; hold falsts; wall ties; hooks for hanging fans; plain angle cleats for seuring purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe 410-o or Fe 310-o complete all as specified and directed by Engr-In-Charge.
Supply & fix Mild Steel heavy weight colled rolled (ISI marked) butt hinges 100 mm long complete all as specified & directed by Engineer-in-Charge.
S&F 250 mm long Mild steel, sliding door bolt with hasp, staple (bolt type) not less than 12 mm dia and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminum alloy complete all as specified & directed by Engineer-in- Charge.
S&F of air termination rod 12 mm dia single pointed 300 mm long along with base plate welded at bottom of termination rod,of size 10 cm long fabricated out 25x3 mm thick aluminium strip along with making 9 mm dia for fixing in fastners (wooden block) includidng taking down old unserviceable air termination rod complete all as specified and directed by Engineer -in-Charge.
M&L for aluminium strip 25mmx3.15mm complete with seaddles and fixing screws etc for roof conductors and down conductors above ground including taking down old unserviceable aluminium strip complete all as specified and directed by Engineer -in-Charge.
Material & labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit /pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32X6mm galvanised iron strip including taking down old unserviceable earth continuitty conductor complete all as specified and directed by Engineer -in-Charge.
M&L in repair for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick packed layer of charcoal dust and common salt, connected to galvanized iron strip 32mm x 6mm thick as earth lead by means of bolts, nuts and washers of galvanised iron or steel and thimbles and other end of the earth strip connected to earthing test point/equipment and protected by galvanised iron pipe light grade 50mm dia upto earthing test point/equipment fixed with 2 Nos of mild steel clamp made out 25mm x 3mm flat iron and perforated water pipe 20mm dia GI medium grade and top with socket & plug and bottom connected to earth plate by slit and two bolts/nuts/washers, PCC chamber in cement concrete (1:3:6) type C-1 and CI cover with frame all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009. Note:- (i) Outer edge of earth pit shall be 1.5 metre away from the outer edge of PCC chamber. (ii) GI strip upto earth test point/equipment is included in this item. (iii) Water pipe shall be provided in slantling position. (iv) Unit rate included earth wire strip and protection pipe upto 7.50 meter from top of earth plate.
M&L in repair for test points as per IS specifications of shape and size as approved by GE and Engineer-in-Charge, made of gun metal or phosphorus bronze of size 75x75x25mm drilled and screwed including 3 nos, 8mm dia, 25 mm long hexagonal screw complete all as specified and directed by Engineer -in-Charge.
Supply and fix porcelain insulator 11000 volts grade, of size 15cmx7.5cmx0.57cm for insulation of conductor from the building wall by provviding 15cm long fastner at every 16cm distance in the wall complete all as specified and directed by Engineer-in-Charge.
S&F PCC block size 25x25x30cm height in PCC 1:2:3 type B1 using 20mm graded stone aggregate providing 02 Nos MS fastener at the top of the block by using 8/9mm dia 20cm long bolts with T junction of 10cm & embedded in the PCC block, keep 7cm portion of the bolt above the upper surface of PCC block alongwith 2 Nos washers and nuts etc complete all as specified and directed by Engineer in Charge.
S&F wooden block of locally available hard wood of size 25 x 10 x 5cm for mounted on top of PCC block for errection of air termination alongwith bolts and nuts and run the roof conductor complete all as specified and directed by Engineer in Charge.
M &L in replacement of 1x10 watt LED retrofit type bulk head fitting luminaries die cast aluminium alloy body heat resistant prismatic glass cover,with specially designed gasket, lamp holder etc with all accessories and including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230 V,50HZ complete all as specified and directed by Engineer in Charge. Note :- A Sum of Rs. 10,304.00 will be deducted on account of credit for dismantling/ demolished/ taking down material. Please refer detail on srl page No. 30 (Schedule of credit) of Tender Documents.
M/S RAJESH KUMAR and CO.
BABA FARID CONSTRUCTION CO
msgurjantconstructioncompany
DIAMOND SALES COROPORATION
Sandeep Enterprises
G.S CONSTRUCTION.CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .