Loading…
Loading…
Tender Value
₹4.8 Cr
EMD Value
₹2.4 L
Closing Date
16 Jul 2026, 5:00 pm
- PANKAJ MISHRA(DFLT)
CGSWC
CONSTRCTION OF GODOWN COMPLEX-(GROUP NO. 14) KESHLOOR 3600 MT & DANTEWADA (BHOGAM) 1800 MT [Total 5400 MT]
194499
No ./7180/CGSWC / CONST. / 2026-27 / Raipur Dt- 30.06.2026
RESTRICTED TENDER
WORKS
12 days
CGSWC
Required Past Technical Experience: As per NIT Document
Required Financial Turnover (in INR): AS PER NIT
Required Bid Capacity (in INR): AS PER NIT
16 documents required · 16 mandatory
Chhattisgarh State Warehousing Corporation (CGSWC)
WORKS
- PANKAJ MISHRA(DFLT)
RESTRICTED TENDER
PERCENTAGE
A B
CGSWC
TENDER SECTION
CGSWC
120
12
No
0
194499
16 Jul, 2026 5:00:00 PM IST
17 Jul, 2026 11:01:00 AM IST
2 Jul, 2026 5:45:00 PM IST
No ./7180/CGSWC / CONST. / 2026-27 / Raipur Dt- 30.06.2026
CONSTRCTION OF GODOWN COMPLEX-(GROUP NO. 14) KESHLOOR 3600 MT & DANTEWADA (BHOGAM) 1800 MT [Total 5400 MT]
239100.00 INR
RTGS/CHALLAN (ONLINE) Internet Banking (ONLINE)
47815000.00
2
47815000
AS PER NIT
AS PER NIT
As per NIT Document
0.00 INR
14d 16h 21m
16 documents required · 16 mandatory
₹0
₹2.4 L
2 Jul 2026
2 Jul 2026
17 Jul 2026
2 Jul 2026
16 Jul 2026
2 Jul 2026
Surface dressing of the ground including removing vegetation and making up undulations and in-equalities not exceeding 15 cms in depth/ height including disposal of rubbish upto 1.5 m lift and lead upto 50m (at least 5m away from the dressed area).
Excavation for all types of foundations,trenches and drains or for any othere purpose including disposal of excavated stuff upto 50m lead and a lift upto 1.50 M. (at least 5.00 M. away from the excavated area) including dressing and leveling of pits. In all types of soil.
Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size).
1:4:8 (1 cement : 4 course sand : 8 graded stone aggregate 40 mm. Nominal size)
Providing and placing in position reinforcement for R.C.C. work including straightenigng, cutting, bending, binding etc. complete as per drawings including cost of binding wire and including all complete.Thrermo-mechanically treated bars.
Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works up to floor five level excluding cost of form work. 1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggregate 20 mm. Nominal size)
Up to 4.00 M. Height
Above 4.00 M. to 8.00 M.
Above 8.00 M. to 12.00 M.
Providing and fixing formwork i/c centering, shuttering, strutting, staging, propping bracing etc complete and including its removal all levels for :Foundations, footing, base of columns and plinth beam in any shape and size.
Columns-rectangular or square in shape. (i) Up to 4m height
Above 4.00 M. to 5.00 M.
Above 5.00 M. to 6.00 M.
Above 6.00 M. to 7.00 M.
Above 7.00 M. to 8.00 M.
Above 8.00 M. to 9.00 M.
Wall of any thickness including attached pilasters, buttresses etc.
Above 6.00 M. to 7.00 M.
Above 7.00 M. to 8.00 M.
Above 8.00 M. to 9.00 M.
Above 9.00 M. to 10.00 M.
(D) weather shade chhajja cornies and moulding.
Suspended floor roof access plate form balconies (plain surface)and shelves(cast in situ)
Edge of slab breaks in floorand wall up to 200mm
Beams, lintel, cantilevers & walls.
Above 5.00 M. to6.00 m
Brick work with modular fly-ash lime bricks (FALG Bricks) confirming to IS:12894-2002 of class designation 40 in foundation and plinth in:Cement Mortar 1:6 (1 Cement : 6 Sand)
Extra for brick work In S/S above plinth & up to floor five level.
Extra for brick work In S/S above 4.00 m & upto 8.00 M
Filling from available stuff (Excluding rock) in trenches, plinth, sides of foundation etc in layers not exceeding 20cm. in depth consolidating each deposited layer by ramming and watering with a lead up to 50M. and lift up to 1.5M.
Providing and filling in plinth with sand/Crusher dust and hard moorum under floor in layers not exceeding 20 Cm. In depth consolidating each deposited layer by ramming & watering including dressing etc complete.
Extra for providing & fixing 4 mm. Thick glass strips in joints of Terrazzo floor/ cement concrete floor & or like. 40 mm. wide
60 mm. Wide
Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of red oxide zinc chromate primer.
Cement concrete flooring with cement concrete 1:2:4 concrete (1 cement : 2 course sand : 4 graded stone aggregate 20mm) finished with a floating coat of neat cement. 50mm thick
75mm thick
Providing and making 12mm thick cement plaster of mix:In Cement Mortar 1:6 (1 cement : 6 fine sand)
Providing and Fixing Ceramic glazed wall tile
Providing and Fixing Ceramic glazed wall tile
Providing and laying vitrified floor tiles with double charge/ multi charge printing with water absorption less than 0.5% and conforming to IS : 15622 of approved make in all colours and shades and size mentioned below (+/- 10mm), laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete. Size 600x600mm
Providing and fixing factory made ISI marks steel doors, windows and ventilators side/ top/ centre hung made up of standard rolled steel section conforming to IS 1038:1968 (viz. F7D, F4B, K11 and K12B etc.), joints mitred and flash butt and sash bars tenoned and riveted/ welded with 10 cm long lugs of size 15x3mm embedded in cement concrete block 15x10x10 cms of 1:3:6 (1 cement :3 Coarse sand: 6 graded stone aggregate 20 mm nominal size) or rawl plugs and screws or with bolts and nuts as required including providing and fixing of hinges, pivots, handles, pegs, stays, rolling devices, locking arrangements, spring catch etc., as required complete including applying a priming coat of red oxide zinc chromate primer.
Providing and fixing M.S. grill of approved pattern made of M.S. flats or square or round bars welded to steel frame of windows etc. including applying a priming coat welded to frame with all necessary fitting complete including applying a priming of red oxide zinc chromate primer.
Providing and fixing aluminium work for doors, windows, ventilators and partitions made out of extruded aluminium standard sections (main section with minimum 1.5mm thickness) conforming to IS: 733, IS: 1285 mitred and jointed mechanically including aluminium cleats, neoprene weather stripping gasket beveled edge beading, screws duly fixed in wall/ floor with fixing clips or hold fasteners or bolts and nuts as required aluminium sections shall be anodized transparent or dyed to approved shade according to IS: 1868, minimum anodic coating shall be of grade AC-15. (Glazing to be paid for separately: For fixed portion
For shutter of doors, windows & ventilators including providing and making provision for fixing of fitting wherever required including the cost of PVC/ neoprene gasket required (Fittings shall be paid for separately).
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete. (Cost of aluminium snap beading.With float glass panes of 6 mm thickness
Providing and fixing 2mm thick semi transparent polycarbonate profile roofing sheet of approved make and colour to make any normal roofing / covering and fixing as per manufacture specification at spacing not more than 1.2 m centre to centre with EPDM gasket and silicon sealant fixed with self drilling stainless steel screws all complete as per direction of Engineer-in-Charge
Supplying and fixing rolling shutter of approved makes made of M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft, with brackets, side guides and arrangements for inside and out side locking with push and pull arrangement complete but excluding the cost of top cover and spring.80 x 1.25 mm. M.S. laths
Extra for providing grilled rolling shutter manufactured out of 8 mm dia. M.S. bar instead of laths as per approved design (area of grill provided, only to be measured).
Providing and fixing 27.5cm. long wire spring for rolling shutters.
Providing and fixing M.S. sheet top cover for rolling shutter.0.90 mm. thick
Providing andfixing ball bearing for rolling shutters.
Providing and fixing M.S. frames of doors, windows and ventilators joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10cm of grade M-10 or with wooden plugs and screws or with dash fastener or rawl plugs and screws or with fixing clips or with bolts and nuts as required including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.In Angle-iron frames
Providing and fixing in position welded steel wire fabric to concrete/ wooden/ angle iron posts including securing and screwing with G.I. tying wire, G.I. stapples, G.I.U-nails or steel pins etc., complete. Aperture 50x25mm
Providing and fixing flush door shutters, conforming to IS : 2202 (Part-I), decorative type core of block board construction with frame of first class hard wood and well matched teak ply veneering with vertical grains or cross bands and face veneers on both faces of shutters excluding hinges.30 mm. thick (single leaf)
Providing and fixing stainless steel tower bolts (Barrel type) with necessary stainless steel screws etc complete. 250 x10mm
Providing and fixing stainless steel tower bolts (Barrel type) with necessary stainless steel screws etc complete. 250 x10mm
Providing and fixing stainless steel sliding door bolts with 16mm rod, 2.5mm thick flap, necessary stainless steel nuts bolts and screws etc complete. 300mm
Providing and fixing stainless steel hanging door stopper with necessary stainless steel screws complete. Single
Providing and fixing stainless steel door handles having flap thickness 2.5mm, necessary stainless steel screws etc complete. 150 mm
Providing and fixing stainless steel piano hinges with necessary stainless steel screws etc complete. Overall width 25 mm
Providing and fixing factory made PVC door shutter
Steel work in tubular structure in built-up sections, trusses and frame work including cutting, hoisting, fixing in position upto a height of 5m above plinth level, consisting of columns trusses, roof and bottom purlins, base plate, holding down bolts, wind ties bracing (if required), bolts, nuts and washers for fastening etc. complete with applying a priming coat of red oxide zinc chromate primer.Electric resistance or induction butt welded tubes Grade-300. Upto 5.00 M. height.
Above 5.00 M. height.
Extra for providing and fixing wind ties of 40 x 6 mm flat iron section.
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm +/- 5% total coated thickness (TCT), Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete : Crimp curve
Supply and fixing of polymer precoated galvalume profile sheets (PPGL) of approved size, shape and pitch of corrugation, total coated thickness (TCT) 0.60 mm +/- 5%, epoxy primer on both side of the sheet and colour polyester top coat 18-20 microns and 6-7 microns on bottom. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM seal or with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix:In Cement Mortar 1:6 (1 cement : 6 fine sand)
Providing and making 6mm thick cement plaster of mix:n Cement mortar 1:4 (1 cement : 4 fine sand)
Half brick thick brick masonry with fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in superstructure above plinth level upto plinth level: Cement Mortar 1:4 (1 cement : 4 coarse sand)
Extra for lining over plaster to imitate stone or concrete block walling.
Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size).Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth:
Providing and applying plaster of paris putty over plastered wall surface including scaffolding complete
Providing and applying Economy Plastic emulsion paint with roller application minimum three coats appied @ 1.25 lit /10 Sqm up to final finish as per relevant I.S. Code 15489:2013 Туpe -1 Class D & C (Glossy and Semi Glossy Finish) of required shade (product such as Tractor emulsion, Dulux Promise, Nerolac Bueaty Silver, Berger bison/breeze, Opus 130/ Style Paint) inclusive of providing abro tape on edges and article and cleaning of door, windows, floor and surface as required with all tools tackles and labour complete for the work. (With 2 Year warranty).
Providing and applying Polymaric cement primer on all surface applied @ 0.80 litrs/10 sqm as per relevant I.S. code 15489:1974 (product such as Birla white primacoat/activcoat, Asian Trucare, Dulux interior cement primer, Opus Calista/110) with all tool tackles and labour etc. complete for the work.
Providing and applying on exterior surface with LITE ECONOMY Exterior Emulsion paint of required shades to give protective and water proof finish minimum three coats applied @ 1.43 lit / 10Sqm up to final finish as per relevant I.S. Code 15489:2013 Туpe -2 Class D, C (Glossy /Semi Glossy finish) (Product such as Asian ACE Spark, Dulux Pomise exterior smart, Nerolac Littil Master, Berger Bison Lite, Nippon Superio etc) inclusive of providing abro tape on edges and article and cleaning of door, windows, floor and surface as required with all tools tackles and labour etc. complete for the work (With 2 Year Warranty.
Providing and applying Glossy finish Enamel paint mimimum 2 coats in all surface applying @ 0.75 lit/ 10 Sqm up to required finish as per relevent I.S. code 2932: 2013 of (Product such as Asian Apcolite Premium Enamel, Dulux Promise Premium Enamel, Nerolac Synthatic Enamel, Opus Prime enamel inclusive of providing abro tape on edges and article and cleaning of door, windows, floor and surface as required with all tools tackle and labour etc. complete for the work.
Surface dressing of the ground including removing vegetation and making up undulations and in-equalities not exceeding 15 cms in depth/ height including disposal of rubbish upto 1.5 m lift and lead upto 50m (at least 5m away from the dressed area).
Excavation for all types of foundations,trenches and drains or for any othere purpose including disposal of excavated stuff upto 50m lead and a lift upto 1.50 M. (at least 5.00 M. away from the excavated area) including dressing and leveling of pits. In all types of soil.
Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size).
1:4:8 (1 cement : 4 course sand : 8 graded stone aggregate 40 mm. Nominal size)
Providing and placing in position reinforcement for R.C.C. work including straightenigng, cutting, bending, binding etc. complete as per drawings including cost of binding wire and including all complete.Thrermo-mechanically treated bars.
Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works up to floor five level excluding cost of form work. 1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggregate 20 mm. Nominal size)
Up to 4.00 M. Height
Above 4.00 M. to 8.00 M.
Above 8.00 M. to 12.00 M.
Providing and fixing formwork i/c centering, shuttering, strutting, staging, propping bracing etc complete and including its removal all levels for :Foundations, footing, base of columns and plinth beam in any shape and size.
Columns-rectangular or square in shape. (i) Up to 4m height
Above 4.00 M. to 5.00 M.
Above 5.00 M. to 6.00 M.
Above 6.00 M. to 7.00 M.
Above 7.00 M. to 8.00 M.
Above 8.00 M. to 9.00 M.
Wall of any thickness including attached pilasters, buttresses etc.
Above 6.00 M. to 7.00 M.
Above 7.00 M. to 8.00 M.
Above 8.00 M. to 9.00 M.
Above 9.00 M. to 10.00 M.
(D) weather shade chhajja cornies and moulding.
Suspended floor roof access plate form balconies (plain surface)and shelves(cast in situ)
Edge of slab breaks in floorand wall up to 200mm
Beams, lintel, cantilevers & walls.
Above 5.00 M. to6.00 m
Brick work with modular fly-ash lime bricks (FALG Bricks) confirming to IS:12894-2002 of class designation 40 in foundation and plinth in:Cement Mortar 1:6 (1 Cement : 6 Sand)
Extra for brick work In S/S above plinth & up to floor five level.
Extra for brick work In S/S above 4.00 m & upto 8.00 M
Filling from available stuff (Excluding rock) in trenches, plinth, sides of foundation etc in layers not exceeding 20cm. in depth consolidating each deposited layer by ramming and watering with a lead up to 50M. and lift up to 1.5M.
Providing and filling in plinth with sand/Crusher dust and hard moorum under floor in layers not exceeding 20 Cm. In depth consolidating each deposited layer by ramming & watering including dressing etc complete.
Extra for providing & fixing 4 mm. Thick glass strips in joints of Terrazzo floor/ cement concrete floor & or like. 40 mm. wide
60 mm. Wide
Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of red oxide zinc chromate primer.
Cement concrete flooring with cement concrete 1:2:4 concrete (1 cement : 2 course sand : 4 graded stone aggregate 20mm) finished with a floating coat of neat cement. 50mm thick
75mm thick
Providing and making 12mm thick cement plaster of mix:In Cement Mortar 1:6 (1 cement : 6 fine sand)
Providing and Fixing Ceramic glazed wall tile
Providing and Fixing Ceramic glazed wall tile
Providing and laying vitrified floor tiles with double charge/ multi charge printing with water absorption less than 0.5% and conforming to IS : 15622 of approved make in all colours and shades and size mentioned below (+/- 10mm), laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete. Size 600x600mm
Providing and fixing factory made ISI marks steel doors, windows and ventilators side/ top/ centre hung made up of standard rolled steel section conforming to IS 1038:1968 (viz. F7D, F4B, K11 and K12B etc.), joints mitred and flash butt and sash bars tenoned and riveted/ welded with 10 cm long lugs of size 15x3mm embedded in cement concrete block 15x10x10 cms of 1:3:6 (1 cement :3 Coarse sand: 6 graded stone aggregate 20 mm nominal size) or rawl plugs and screws or with bolts and nuts as required including providing and fixing of hinges, pivots, handles, pegs, stays, rolling devices, locking arrangements, spring catch etc., as required complete including applying a priming coat of red oxide zinc chromate primer.
Providing and fixing M.S. grill of approved pattern made of M.S. flats or square or round bars welded to steel frame of windows etc. including applying a priming coat welded to frame with all necessary fitting complete including applying a priming of red oxide zinc chromate primer.
Providing and fixing aluminium work for doors, windows, ventilators and partitions made out of extruded aluminium standard sections (main section with minimum 1.5mm thickness) conforming to IS: 733, IS: 1285 mitred and jointed mechanically including aluminium cleats, neoprene weather stripping gasket beveled edge beading, screws duly fixed in wall/ floor with fixing clips or hold fasteners or bolts and nuts as required aluminium sections shall be anodized transparent or dyed to approved shade according to IS: 1868, minimum anodic coating shall be of grade AC-15. (Glazing to be paid for separately: For fixed portion
For shutter of doors, windows & ventilators including providing and making provision for fixing of fitting wherever required including the cost of PVC/ neoprene gasket required (Fittings shall be paid for separately).
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete. (Cost of aluminium snap beading.With float glass panes of 6 mm thickness
Providing and fixing 2mm thick semi transparent polycarbonate profile roofing sheet of approved make and colour to make any normal roofing / covering and fixing as per manufacture specification at spacing not more than 1.2 m centre to centre with EPDM gasket and silicon sealant fixed with self drilling stainless steel screws all complete as per direction of Engineer-in-Charge
Supplying and fixing rolling shutter of approved makes made of M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft, with brackets, side guides and arrangements for inside and out side locking with push and pull arrangement complete but excluding the cost of top cover and spring.80 x 1.25 mm. M.S. laths
Extra for providing grilled rolling shutter manufactured out of 8 mm dia. M.S. bar instead of laths as per approved design (area of grill provided, only to be measured).
Providing and fixing 27.5cm. long wire spring for rolling shutters.
Providing and fixing M.S. sheet top cover for rolling shutter.0.90 mm. thick
Providing andfixing ball bearing for rolling shutters.
Providing and fixing M.S. frames of doors, windows and ventilators joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10cm of grade M-10 or with wooden plugs and screws or with dash fastener or rawl plugs and screws or with fixing clips or with bolts and nuts as required including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.In Angle-iron frames
Providing and fixing in position welded steel wire fabric to concrete/ wooden/ angle iron posts including securing and screwing with G.I. tying wire, G.I. stapples, G.I.U-nails or steel pins etc., complete. Aperture 50x25mm
Providing and fixing flush door shutters, conforming to IS : 2202 (Part-I), decorative type core of block board construction with frame of first class hard wood and well matched teak ply veneering with vertical grains or cross bands and face veneers on both faces of shutters excluding hinges.30 mm. thick (single leaf)
Providing and fixing stainless steel tower bolts (Barrel type) with necessary stainless steel screws etc complete. 250 x10mm
Providing and fixing stainless steel tower bolts (Barrel type) with necessary stainless steel screws etc complete. 250 x10mm
Providing and fixing stainless steel sliding door bolts with 16mm rod, 2.5mm thick flap, necessary stainless steel nuts bolts and screws etc complete. 300mm
Providing and fixing stainless steel hanging door stopper with necessary stainless steel screws complete. Single
Providing and fixing stainless steel door handles having flap thickness 2.5mm, necessary stainless steel screws etc complete. 150 mm
Providing and fixing stainless steel piano hinges with necessary stainless steel screws etc complete. Overall width 25 mm
Providing and fixing factory made PVC door shutter
Steel work in tubular structure in built-up sections, trusses and frame work including cutting, hoisting, fixing in position upto a height of 5m above plinth level, consisting of columns trusses, roof and bottom purlins, base plate, holding down bolts, wind ties bracing (if required), bolts, nuts and washers for fastening etc. complete with applying a priming coat of red oxide zinc chromate primer.Electric resistance or induction butt welded tubes Grade-300. Upto 5.00 M. height.
Above 5.00 M. height.
Extra for providing and fixing wind ties of 40 x 6 mm flat iron section.
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm +/- 5% total coated thickness (TCT), Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete : Crimp curve
Supply and fixing of polymer precoated galvalume profile sheets (PPGL) of approved size, shape and pitch of corrugation, total coated thickness (TCT) 0.60 mm +/- 5%, epoxy primer on both side of the sheet and colour polyester top coat 18-20 microns and 6-7 microns on bottom. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM seal or with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix:In Cement Mortar 1:6 (1 cement : 6 fine sand)
Providing and making 6mm thick cement plaster of mix:n Cement mortar 1:4 (1 cement : 4 fine sand)
Half brick thick brick masonry with fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in superstructure above plinth level upto plinth level: Cement Mortar 1:4 (1 cement : 4 coarse sand)
Extra for lining over plaster to imitate stone or concrete block walling.
Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size).Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth:
Providing and applying plaster of paris putty over plastered wall surface including scaffolding complete
Providing and applying Economy Plastic emulsion paint with roller application minimum three coats appied @ 1.25 lit /10 Sqm up to final finish as per relevant I.S. Code 15489:2013 Туpe -1 Class D & C (Glossy and Semi Glossy Finish) of required shade (product such as Tractor emulsion, Dulux Promise, Nerolac Bueaty Silver, Berger bison/breeze, Opus 130/ Style Paint) inclusive of providing abro tape on edges and article and cleaning of door, windows, floor and surface as required with all tools tackles and labour complete for the work. (With 2 Year warranty).
Providing and applying Polymaric cement primer on all surface applied @ 0.80 litrs/10 sqm as per relevant I.S. code 15489:1974 (product such as Birla white primacoat/activcoat, Asian Trucare, Dulux interior cement primer, Opus Calista/110) with all tool tackles and labour etc. complete for the work.
Providing and applying on exterior surface with LITE ECONOMY Exterior Emulsion paint of required shades to give protective and water proof finish minimum three coats applied @ 1.43 lit / 10Sqm up to final finish as per relevant I.S. Code 15489:2013 Туpe -2 Class D, C (Glossy /Semi Glossy finish) (Product such as Asian ACE Spark, Dulux Pomise exterior smart, Nerolac Littil Master, Berger Bison Lite, Nippon Superio etc) inclusive of providing abro tape on edges and article and cleaning of door, windows, floor and surface as required with all tools tackles and labour etc. complete for the work (With 2 Year Warranty.
Providing and applying Glossy finish Enamel paint mimimum 2 coats in all surface applying @ 0.75 lit/ 10 Sqm up to required finish as per relevent I.S. code 2932: 2013 of (Product such as Asian Apcolite Premium Enamel, Dulux Promise Premium Enamel, Nerolac Synthatic Enamel, Opus Prime enamel inclusive of providing abro tape on edges and article and cleaning of door, windows, floor and surface as required with all tools tackle and labour etc. complete for the work.
Wiring for light/ fan/ exhaust fan / call bell point with 1.5 sqmm FR PVC insulated stranded copper conductor single core cable in concealed PVC conduit, with 5 amp modular switch, modular base and cover plate, suitable size G.I. box and earthing the point with same size cable as required. Short Point
Medium point
Long point
Extra for providing and fixing light plug point on board in concealed PVC conduit point wiring with modular type 3 pin 5 amp socket outlet and 5 amp switch including cost of base and cover plate and G. I. box etc. as required.
Short
Wiring for light plug point with 2x2.5 sq mm FR PVC insulated stranded copper conductor cable in concealed PVC conduit along with modular type 6 Amp switch and 3 pin 6 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size cable etc. as required. Medium Point
Wiring for light plug point with 2x2.5 sq mm FR PVC insulated stranded copper conductor cable in concealed PVC conduit along with modular type 6 Amp switch and 3 pin 6 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size cable etc. as required. Long Point
wiring Short Point
Wiring for power plugpoint with2x4sqmmFRPVC insulatedstrandedcopperconductorcable inconcealed PVCconduitalongwithmodular type16Ampswitchand 6pin16ampssocketoutletwithmodularbaseandcover plate,suitablesizeG.I.box,earthingtheswitchboxand socket outlet with same size cable etc. as required. Medium Point
Long Point
3x2.5 sq. mm in 20 mm conduit
6x2.5 sq. mm in 20 mm conduit.
9x2.5 sq. mm in 20 mm conduit.
Earhting with copper earth plate 600 mm X 600 mm X 3 mm thkick i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe.
Supplying and laying 8 SWG copper wire at 0.50 meter below ground level for conductor earth electrode, i/c solding etc. as required.
Providingandfixingmetalclad,SP&Nswitchfuseunit(re wirable), 230/250 volts, withporcelain re-wireble fuses including drilling holes on the board, connections, earthingthebodyetc. as required. (Thimbelingshall be paid separately). 32 amps
Supplyingandfixingonsurface/ recessprewiredvertical type followingway, 415 volts TP&N, MCBdistribution boardof sheet steel phosphatizedandpowder painted completewithloosewirebox, terminalblocks,200amps tinnedcopperbusbar,commonneutral link,earthbar,din bar, detachable gland plate, loosewire box, superior maketerminal connectors forall incomingandoutgoing circuits, duly prewired with suitable size FR PVC insulated copper conductor up to terminal blocks includinginterconnections,earthingetc.asrequired. (But withoutMCB/ RCCB/ Isolator) (Note: Prewired vertical typeMCBTPDBisnormallyusedwhere3phaseoutlets are required.)8 way (4 + 24), Single door
100 Amp TP&N
63 Amp TP&N
32 Amp TP&N
Supplyingand fixingonsurface/ recess followingway, 240voltsSP&NMCBdistributionboardof sheet steel phosphatizedandpowder paintedcompletewith tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, including interconnections, earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way, Single door
Supplyingand fixingonsurface/ recesshorizontal type followingway,415volts,TPNMCBdistributionboardof sheet steel phosphatizedandpowderpainted, complete withtinnedcopperbusbar,neutralbusbar,earthbar,din bar, detachableglandplate, including interconnections, earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way Double door
Supplying and fixing DPMCB, 240 volts, 'C' curve, suitablefor lightingandother loads intheexistingMCB DB complete with connections, testing and commissioning etc. as required. 6 amps to 32 amps
Supplying and fixing TPMCB, 440 volts, 'C' curve, suitablefor lightingandother loads intheexistingMCB DB complete with connections, testing and commissioning etc. as required. 6 amps to 32 amps
Supplying and fixing following rating, 240 volts TWO POLE ISOLATOR in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps.
Providingandfixingporcelainre-wireblefusecarrierand baseunitonwoodenboardincludingdrillingholesonthe board,screws,connectionsetc.asrequired. (Thimbeling shall be paid separately)100 amps
4 x 25 sq. mm.
4 x 10 sq. mm
4 x 25 sq. mm. on 7 SWG GI bearer wire
4 x 10 sq. mm. on 8 SWG GI bearer wire
Supplyingandfixingmetalcladbusbarchambermadeof 1.6mmthickCRCAsheetwith4stripcopperbusbarsof following capacity and length, complete with all accessories, including earthing the body etc. as required. 200 amps x 450mm long
Providing and fixing round/ hexagonal fan box (125 mm. dia) depth 75mm. (max) with 12 mm. dia steel bar hook, 1.6 mm. thiuck MS sheet cover, in RCC slab etc. as required
Supplyingandfixingmetalboxof followingsizes(nominal size)inrecesswithsuitablesizephenoliclaminatedsheet cover in front including painting etc as required. 75 mm X 75 mm X 60 mm deep
100 mm X 100 mm X 60 mm deep
150 mm X 75 mm X 60 mm deep
180 mm X 100 mm X 60 mm deep
200 mm X 300 mm X 60 mm deep
Supplying, instaling, testing and commissioning of following sizes ceiling fan with resistance type regulqator, i/c wiring the down fods of standard length up to 30 cm. with 1.5 sq. mm. FR PVC insulated, copper conductor, sinle core cable, earthing etc. complete as required. 1200 mm. sweep
Supplying, installation, testing and commissioning of following T-5 fluorescent fitting (luminaries) complete with electronic ballast but without fluorescent lamp, on ceiling/ wall surface, earthing the fitting etc. as required. Single box type with decorative end caps
Supplying, fixing, testingandcommissioningof following 230/250volts fluorescent lamp(tube) inexisting lighting luminaries as required. 4' x 28 watt (T-5)
Supplying, fixing, testingandcommissioningof following LEDlampswithinbuiltelectronicdriverheatsinkandall other accessories in existing holder/ luminaries as requiredandfurnishing2YrsGuaranteecertificatefrom manufacturer. 9 Watt
Supplying, installation, testing and commissioning of following 230/250 volts LED street light fitting with all accessories like driver, heat sink made of die cast aluminium with IP 66 protection and 5 KV surge protection on pole bracket complete as required and furnishing 2 Yrs Guarantee certificate from manufacturer. 40-45 watt
Batten/ angle holder
Ceiling rose 3 pin 5 amp
Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ concealed, steel/ PVC conduit/ PVC casing caping as required.3 x 6 sq. mm
Supplyofswagedsteel tubularpoleasper IS2713with base plate of size 300x300x6mmwelded at bottom, necessaryholeforcableentryandearthingstudwelded atspecifiedheight includingpaintingwithonecoatof red oxide zinc chromate primer. Designation 410 SP-35 height 9.50 metre
Granular Sub-base as per Table:- 400-1 Construction of granular sub base by providing graded Mateial, , Carriage of mixed Material to work site spreading in uniform layers with motor grader on on perpared surface watering , rolling and compacting with vibratory power roller at OMC to achieve the desired density, complete as per clause 401 Plant mix method ( with Mechanically crushed stone only) (A) For Lower Sub-base with (i) Grading-V Material
Wet Mix Macadam (Providing laying, spreading and compacting graded stone aggregate to wet mix machadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site laying in uniform layers with paver in sub -base / base course on well prepared surface and compacting with vibtatory roller to achieve the desired density as per clause
Dry Lean Cement Concrete Sub-base Construction of dry Lean Cement Concrete Sub-base as per IRC:SP-49 over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 26.5 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing as per clause 601.)
Cement Concrete Pavement (Construction of un-reinforced, dowel jointed, plain cement concrete pavement as per IRC:58 over a prepared sub-base, coarse and fine aggregate conforming to IS:383 and graded as per table 600-3 mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing as per clause 602.) (A) Using Slip Form Paver (a) With Cement concrete grade M-40 and minimum cement content @ 400 kg/cum.
Surface dressing of the ground including removing vegetation and making up undulations and in-equalities not exceeding 15 cms in depth/ height including disposal of rubbish upto 1.5 m lift and lead upto 50m (at least 5m away from the dressed area).
Excavation for all types of foundations,trenches and drains or for any othere purpose including disposal of excavated stuff upto 50m lead and a lift upto 1.50 M. (at least 5.00 M. away from the excavated area) including dressing and leveling of pits. In all types of soil.
Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size).
1:4:8 (1 cement : 4 course sand : 8 graded stone aggregate 40 mm. Nominal size)
Providing and placing in position reinforcement for R.C.C. work including straightenigng, cutting, bending, binding etc. complete as per drawings including cost of binding wire and including all complete.Thrermo-mechanically treated bars.
Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works up to floor five level excluding cost of form work. 1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggregate 20 mm. Nominal size)
Up to 4.00 M. Height
Above 4.00 M. to 8.00 M.
Above 8.00 M. to 12.00 M.
Providing and fixing formwork i/c centering, shuttering, strutting, staging, propping bracing etc complete and including its removal all levels for :Foundations, footing, base of columns and plinth beam in any shape and size.
Columns-rectangular or square in shape. (i) Up to 4m height
Above 4.00 M. to 5.00 M.
Above 5.00 M. to 6.00 M.
Above 6.00 M. to 7.00 M.
Above 7.00 M. to 8.00 M.
Above 8.00 M. to 9.00 M.
Wall of any thickness including attached pilasters, buttresses etc.
Above 6.00 M. to 7.00 M.
Above 7.00 M. to 8.00 M.
Above 8.00 M. to 9.00 M.
Above 9.00 M. to 10.00 M.
(D) weather shade chhajja cornies and moulding.
Suspended floor roof access plate form balconies (plain surface)and shelves(cast in situ)
Edge of slab breaks in floorand wall up to 200mm
Beams, lintel, cantilevers & walls.
Above 5.00 M. to6.00 m
Brick work with modular fly-ash lime bricks (FALG Bricks) confirming to IS:12894-2002 of class designation 40 in foundation and plinth in:Cement Mortar 1:6 (1 Cement : 6 Sand)
Extra for brick work In S/S above plinth & up to floor five level.
Extra for brick work In S/S above 4.00 m & upto 8.00 M
Filling from available stuff (Excluding rock) in trenches, plinth, sides of foundation etc in layers not exceeding 20cm. in depth consolidating each deposited layer by ramming and watering with a lead up to 50M. and lift up to 1.5M.
Providing and filling in plinth with sand/Crusher dust and hard moorum under floor in layers not exceeding 20 Cm. In depth consolidating each deposited layer by ramming & watering including dressing etc complete.
Extra for providing & fixing 4 mm. Thick glass strips in joints of Terrazzo floor/ cement concrete floor & or like. 40 mm. wide
60 mm. Wide
Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of red oxide zinc chromate primer.
Cement concrete flooring with cement concrete 1:2:4 concrete (1 cement : 2 course sand : 4 graded stone aggregate 20mm) finished with a floating coat of neat cement. 50mm thick
75mm thick
Providing and making 12mm thick cement plaster of mix:In Cement Mortar 1:6 (1 cement : 6 fine sand)
Providing and Fixing Ceramic glazed wall tile
Providing and Fixing Ceramic glazed wall tile
Providing and laying vitrified floor tiles with double charge/ multi charge printing with water absorption less than 0.5% and conforming to IS : 15622 of approved make in all colours and shades and size mentioned below (+/- 10mm), laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete. Size 600x600mm
Providing and fixing factory made ISI marks steel doors, windows and ventilators side/ top/ centre hung made up of standard rolled steel section conforming to IS 1038:1968 (viz. F7D, F4B, K11 and K12B etc.), joints mitred and flash butt and sash bars tenoned and riveted/ welded with 10 cm long lugs of size 15x3mm embedded in cement concrete block 15x10x10 cms of 1:3:6 (1 cement :3 Coarse sand: 6 graded stone aggregate 20 mm nominal size) or rawl plugs and screws or with bolts and nuts as required including providing and fixing of hinges, pivots, handles, pegs, stays, rolling devices, locking arrangements, spring catch etc., as required complete including applying a priming coat of red oxide zinc chromate primer.
Providing and fixing M.S. grill of approved pattern made of M.S. flats or square or round bars welded to steel frame of windows etc. including applying a priming coat welded to frame with all necessary fitting complete including applying a priming of red oxide zinc chromate primer.
Providing and fixing aluminium work for doors, windows, ventilators and partitions made out of extruded aluminium standard sections (main section with minimum 1.5mm thickness) conforming to IS: 733, IS: 1285 mitred and jointed mechanically including aluminium cleats, neoprene weather stripping gasket beveled edge beading, screws duly fixed in wall/ floor with fixing clips or hold fasteners or bolts and nuts as required aluminium sections shall be anodized transparent or dyed to approved shade according to IS: 1868, minimum anodic coating shall be of grade AC-15. (Glazing to be paid for separately: For fixed portion
For shutter of doors, windows & ventilators including providing and making provision for fixing of fitting wherever required including the cost of PVC/ neoprene gasket required (Fittings shall be paid for separately).
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete. (Cost of aluminium snap beading.With float glass panes of 6 mm thickness
Providing and fixing 2mm thick semi transparent polycarbonate profile roofing sheet of approved make and colour to make any normal roofing / covering and fixing as per manufacture specification at spacing not more than 1.2 m centre to centre with EPDM gasket and silicon sealant fixed with self drilling stainless steel screws all complete as per direction of Engineer-in-Charge
Supplying and fixing rolling shutter of approved makes made of M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft, with brackets, side guides and arrangements for inside and out side locking with push and pull arrangement complete but excluding the cost of top cover and spring.80 x 1.25 mm. M.S. laths
Extra for providing grilled rolling shutter manufactured out of 8 mm dia. M.S. bar instead of laths as per approved design (area of grill provided, only to be measured).
Providing and fixing 27.5cm. long wire spring for rolling shutters.
Providing and fixing M.S. sheet top cover for rolling shutter.0.90 mm. thick
Providing andfixing ball bearing for rolling shutters.
Providing and fixing M.S. frames of doors, windows and ventilators joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10cm of grade M-10 or with wooden plugs and screws or with dash fastener or rawl plugs and screws or with fixing clips or with bolts and nuts as required including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.In Angle-iron frames
Providing and fixing in position welded steel wire fabric to concrete/ wooden/ angle iron posts including securing and screwing with G.I. tying wire, G.I. stapples, G.I.U-nails or steel pins etc., complete. Aperture 50x25mm
Providing and fixing flush door shutters, conforming to IS : 2202 (Part-I), decorative type core of block board construction with frame of first class hard wood and well matched teak ply veneering with vertical grains or cross bands and face veneers on both faces of shutters excluding hinges.30 mm. thick (single leaf)
Providing and fixing stainless steel tower bolts (Barrel type) with necessary stainless steel screws etc complete. 250 x10mm
Providing and fixing stainless steel tower bolts (Barrel type) with necessary stainless steel screws etc complete. 250 x10mm
Providing and fixing stainless steel sliding door bolts with 16mm rod, 2.5mm thick flap, necessary stainless steel nuts bolts and screws etc complete. 300mm
Providing and fixing stainless steel hanging door stopper with necessary stainless steel screws complete. Single
Providing and fixing stainless steel door handles having flap thickness 2.5mm, necessary stainless steel screws etc complete. 150 mm
Providing and fixing stainless steel piano hinges with necessary stainless steel screws etc complete. Overall width 25 mm
Providing and fixing factory made PVC door shutter
Steel work in tubular structure in built-up sections, trusses and frame work including cutting, hoisting, fixing in position upto a height of 5m above plinth level, consisting of columns trusses, roof and bottom purlins, base plate, holding down bolts, wind ties bracing (if required), bolts, nuts and washers for fastening etc. complete with applying a priming coat of red oxide zinc chromate primer.Electric resistance or induction butt welded tubes Grade-300. Upto 5.00 M. height.
Above 5.00 M. height.
Extra for providing and fixing wind ties of 40 x 6 mm flat iron section.
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm +/- 5% total coated thickness (TCT), Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete : Crimp curve
Supply and fixing of polymer precoated galvalume profile sheets (PPGL) of approved size, shape and pitch of corrugation, total coated thickness (TCT) 0.60 mm +/- 5%, epoxy primer on both side of the sheet and colour polyester top coat 18-20 microns and 6-7 microns on bottom. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM seal or with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix:In Cement Mortar 1:6 (1 cement : 6 fine sand)
Providing and making 6mm thick cement plaster of mix:n Cement mortar 1:4 (1 cement : 4 fine sand)
Half brick thick brick masonry with fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in superstructure above plinth level upto plinth level: Cement Mortar 1:4 (1 cement : 4 coarse sand)
Extra for lining over plaster to imitate stone or concrete block walling.
Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size).Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth:
Providing and applying plaster of paris putty over plastered wall surface including scaffolding complete
Providing and applying Economy Plastic emulsion paint with roller application minimum three coats appied @ 1.25 lit /10 Sqm up to final finish as per relevant I.S. Code 15489:2013 Туpe -1 Class D & C (Glossy and Semi Glossy Finish) of required shade (product such as Tractor emulsion, Dulux Promise, Nerolac Bueaty Silver, Berger bison/breeze, Opus 130/ Style Paint) inclusive of providing abro tape on edges and article and cleaning of door, windows, floor and surface as required with all tools tackles and labour complete for the work. (With 2 Year warranty).
Providing and applying Polymaric cement primer on all surface applied @ 0.80 litrs/10 sqm as per relevant I.S. code 15489:1974 (product such as Birla white primacoat/activcoat, Asian Trucare, Dulux interior cement primer, Opus Calista/110) with all tool tackles and labour etc. complete for the work.
Providing and applying on exterior surface with LITE ECONOMY Exterior Emulsion paint of required shades to give protective and water proof finish minimum three coats applied @ 1.43 lit / 10Sqm up to final finish as per relevant I.S. Code 15489:2013 Туpe -2 Class D, C (Glossy /Semi Glossy finish) (Product such as Asian ACE Spark, Dulux Pomise exterior smart, Nerolac Littil Master, Berger Bison Lite, Nippon Superio etc) inclusive of providing abro tape on edges and article and cleaning of door, windows, floor and surface as required with all tools tackles and labour etc. complete for the work (With 2 Year Warranty.
Providing and applying Glossy finish Enamel paint mimimum 2 coats in all surface applying @ 0.75 lit/ 10 Sqm up to required finish as per relevent I.S. code 2932: 2013 of (Product such as Asian Apcolite Premium Enamel, Dulux Promise Premium Enamel, Nerolac Synthatic Enamel, Opus Prime enamel inclusive of providing abro tape on edges and article and cleaning of door, windows, floor and surface as required with all tools tackle and labour etc. complete for the work.
Wiring for light/ fan/ exhaust fan / call bell point with 1.5 sqmm FR PVC insulated stranded copper conductor single core cable in concealed PVC conduit, with 5 amp modular switch, modular base and cover plate, suitable size G.I. box and earthing the point with same size cable as required. Short Point
Medium point
Long point
Extra for providing and fixing light plug point on board in concealed PVC conduit point wiring with modular type 3 pin 5 amp socket outlet and 5 amp switch including cost of base and cover plate and G. I. box etc. as required.
Short
Wiring for light plug point with 2x2.5 sq mm FR PVC insulated stranded copper conductor cable in concealed PVC conduit along with modular type 6 Amp switch and 3 pin 6 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size cable etc. as required. Medium Point
Wiring for light plug point with 2x2.5 sq mm FR PVC insulated stranded copper conductor cable in concealed PVC conduit along with modular type 6 Amp switch and 3 pin 6 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size cable etc. as required. Long Point
wiring Short Point
Wiring for power plugpoint with2x4sqmmFRPVC insulatedstrandedcopperconductorcable inconcealed PVCconduitalongwithmodular type16Ampswitchand 6pin16ampssocketoutletwithmodularbaseandcover plate,suitablesizeG.I.box,earthingtheswitchboxand socket outlet with same size cable etc. as required. Medium Point
Long Point
3x2.5 sq. mm in 20 mm conduit
6x2.5 sq. mm in 20 mm conduit.
9x2.5 sq. mm in 20 mm conduit.
Earhting with copper earth plate 600 mm X 600 mm X 3 mm thkick i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe.
Supplying and laying 8 SWG copper wire at 0.50 meter below ground level for conductor earth electrode, i/c solding etc. as required.
Providingandfixingmetalclad,SP&Nswitchfuseunit(re wirable), 230/250 volts, withporcelain re-wireble fuses including drilling holes on the board, connections, earthingthebodyetc. as required. (Thimbelingshall be paid separately). 32 amps
Supplyingandfixingonsurface/ recessprewiredvertical type followingway, 415 volts TP&N, MCBdistribution boardof sheet steel phosphatizedandpowder painted completewithloosewirebox, terminalblocks,200amps tinnedcopperbusbar,commonneutral link,earthbar,din bar, detachable gland plate, loosewire box, superior maketerminal connectors forall incomingandoutgoing circuits, duly prewired with suitable size FR PVC insulated copper conductor up to terminal blocks includinginterconnections,earthingetc.asrequired. (But withoutMCB/ RCCB/ Isolator) (Note: Prewired vertical typeMCBTPDBisnormallyusedwhere3phaseoutlets are required.)8 way (4 + 24), Single door
100 Amp TP&N
63 Amp TP&N
32 Amp TP&N
Supplyingand fixingonsurface/ recess followingway, 240voltsSP&NMCBdistributionboardof sheet steel phosphatizedandpowder paintedcompletewith tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, including interconnections, earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way, Single door
Supplyingand fixingonsurface/ recesshorizontal type followingway,415volts,TPNMCBdistributionboardof sheet steel phosphatizedandpowderpainted, complete withtinnedcopperbusbar,neutralbusbar,earthbar,din bar, detachableglandplate, including interconnections, earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way Double door
Supplying and fixing DPMCB, 240 volts, 'C' curve, suitablefor lightingandother loads intheexistingMCB DB complete with connections, testing and commissioning etc. as required. 6 amps to 32 amps
Supplying and fixing TPMCB, 440 volts, 'C' curve, suitablefor lightingandother loads intheexistingMCB DB complete with connections, testing and commissioning etc. as required. 6 amps to 32 amps
Supplying and fixing following rating, 240 volts TWO POLE ISOLATOR in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps.
Providingandfixingporcelainre-wireblefusecarrierand baseunitonwoodenboardincludingdrillingholesonthe board,screws,connectionsetc.asrequired. (Thimbeling shall be paid separately)100 amps
4 x 25 sq. mm.
4 x 10 sq. mm
4 x 25 sq. mm. on 7 SWG GI bearer wire
4 x 10 sq. mm. on 8 SWG GI bearer wire
Supplyingandfixingmetalcladbusbarchambermadeof 1.6mmthickCRCAsheetwith4stripcopperbusbarsof following capacity and length, complete with all accessories, including earthing the body etc. as required. 200 amps x 450mm long
Providing and fixing round/ hexagonal fan box (125 mm. dia) depth 75mm. (max) with 12 mm. dia steel bar hook, 1.6 mm. thiuck MS sheet cover, in RCC slab etc. as required
Supplyingandfixingmetalboxof followingsizes(nominal size)inrecesswithsuitablesizephenoliclaminatedsheet cover in front including painting etc as required. 75 mm X 75 mm X 60 mm deep
100 mm X 100 mm X 60 mm deep
150 mm X 75 mm X 60 mm deep
180 mm X 100 mm X 60 mm deep
200 mm X 300 mm X 60 mm deep
Supplying, instaling, testing and commissioning of following sizes ceiling fan with resistance type regulqator, i/c wiring the down fods of standard length up to 30 cm. with 1.5 sq. mm. FR PVC insulated, copper conductor, sinle core cable, earthing etc. complete as required. 1200 mm. sweep
Supplying, installation, testing and commissioning of following T-5 fluorescent fitting (luminaries) complete with electronic ballast but without fluorescent lamp, on ceiling/ wall surface, earthing the fitting etc. as required. Single box type with decorative end caps
Supplying, fixing, testingandcommissioningof following 230/250volts fluorescent lamp(tube) inexisting lighting luminaries as required. 4' x 28 watt (T-5)
Supplying, fixing, testingandcommissioningof following LEDlampswithinbuiltelectronicdriverheatsinkandall other accessories in existing holder/ luminaries as requiredandfurnishing2YrsGuaranteecertificatefrom manufacturer. 9 Watt
Supplying, installation, testing and commissioning of following 230/250 volts LED street light fitting with all accessories like driver, heat sink made of die cast aluminium with IP 66 protection and 5 KV surge protection on pole bracket complete as required and furnishing 2 Yrs Guarantee certificate from manufacturer. 40-45 watt
Batten/ angle holder
Ceiling rose 3 pin 5 amp
Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ concealed, steel/ PVC conduit/ PVC casing caping as required.3 x 6 sq. mm
Supplyofswagedsteel tubularpoleasper IS2713with base plate of size 300x300x6mmwelded at bottom, necessaryholeforcableentryandearthingstudwelded atspecifiedheight includingpaintingwithonecoatof red oxide zinc chromate primer. Designation 410 SP-35 height 9.50 metre
Granular Sub-base as per Table:- 400-1 Construction of granular sub base by providing graded Mateial, , Carriage of mixed Material to work site spreading in uniform layers with motor grader on on perpared surface watering , rolling and compacting with vibratory power roller at OMC to achieve the desired density, complete as per clause 401 Plant mix method ( with Mechanically crushed stone only) (A) For Lower Sub-base with (i) Grading-V Material
Wet Mix Macadam (Providing laying, spreading and compacting graded stone aggregate to wet mix machadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site laying in uniform layers with paver in sub -base / base course on well prepared surface and compacting with vibtatory roller to achieve the desired density as per clause
Dry Lean Cement Concrete Sub-base Construction of dry Lean Cement Concrete Sub-base as per IRC:SP-49 over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 26.5 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing as per clause 601.)
Cement Concrete Pavement (Construction of un-reinforced, dowel jointed, plain cement concrete pavement as per IRC:58 over a prepared sub-base, coarse and fine aggregate conforming to IS:383 and graded as per table 600-3 mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing as per clause 602.) (A) Using Slip Form Paver (a) With Cement concrete grade M-40 and minimum cement content @ 400 kg/cum.
UOM Name
Percentage
Per mile
Per Diem Rate
MAN DAYS
Siemens Per meter
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 1.09 MB
3283564258365578955_194499_Group No 14 Keshloor Dantewada 5400 MT.docx
NIT • 6.53 MB
4648910420447831091_194499_Group No 14 dantewada,keshloor.xlsx
BOQ • 0.09 MB
Download all tender documents and submit your bid