Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹16,380Qualified Make: LASSER
Model: choksi imaging limited 6.5X8.5 PKT of 50 sheets (BLUE) LANE NO 5 5 NEW DELHI DELHI 110046 | NEW DELHI | DELHI | 110046 | Make: LASSER
Model: choksi imaging limited 6.5X8.5 PKT of 50 sheets (BLUE) | ₹16,380 | L1 | Qualified |
| 2 | L2₹16,445+₹65 (0.40%)Qualified Make: Fujifilm
Model: Fujifilm Dry imaging xray film A 203 NANDANI BHAWAN SANT NAGAR BURARI DELHI 110084 NORTH DELHI NATIONAL CAPITAL TERRITORY OF DELHI 110084 | CENTRAL DELHI | DELHI | 110084 | Make: Fujifilm
Model: Fujifilm Dry imaging xray film | ₹16,445+₹65 (0.40%) | L2 | Qualified |
| 3 | L3₹16,497+₹117 (0.71%)Qualified Make: Fujifilm
Model: FUJIFILM MAKE & MODEL SUPER PLUS 6.5 inch x 8.5 inch F 109 PLOT NO 1 AZNARA TOWER L S C SAVITA VIHAR EAST DELHI DELHI 110092 | EAST DELHI | DELHI | 110092 | Make: Fujifilm
Model: FUJIFILM MAKE & MODEL SUPER PLUS 6.5 inch x 8.5 inch | ₹16,497+₹117 (0.71%) | L3 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
25 May 2018, 4:00 pmClosed
medical x ray film processing chemical kit Medical X Ray Film Processing Chemical Kit ( 1300 ) Technical Specifications Specification Specification Name Values Allowed Values construction Table Top Automatic Medical X ray Film Processor machine Yes - Machine Assembly made up of material non corrosive Yes - Length of Machine 8 - Width of Machine 8 - Height of Machine 8 - Rollers Mechanism Motrised - Auto washer Yes - Auto Dryer Yes - Auto Developer Yes - Rollers Material PVC with inner pipes of SS-304 Grade - Material of Cabinet ABS Plastic - Weight (Empty) 250 - Auto Fixer Yes - Automatic Replenishment Yes - certification & test report Radiology Certificate for Processed Film na - 1/4 High Voltage Test 1-5 KV for I minute Yes - Certification na - Availibility of Type Test Report (to be furnished by Seller to Buyer on demand)for performance test false - Test Report number & Date na - Name & Address of Laboratory na - features Continious film roller transport and auto start and stop facility Yes Rigid PVC
Yes Minimum Film size length (mm) x Width (mm) 100 x 100 - Maximum Film size length (mm) x Width (mm) 356 x 432 - Water Filter Compatible with equipment supplied with equipment Yes - Dryer Temprature(maximum) (degree 70 - Minimum Capacity of Fixer
Washer and Developer Tank 5 - Operating Temp Range (degree) (28-37) Degree - Processing Time: 90 sec to 200 sec in steps of six second with LED Display Yes - Maximum Power Consumption (kwh) 0 Mimimum capacity of Replenishment Developer and Fixer Tank with overflow drain facility 25 - Minimum Insulation at 500 V DC na - Developer and Fixer Temprature adjustable Yes - 2/4 throught automatic temprature controller Compatible to Power Supply 220-240 volt
AC
50Hz - Manual
Auto Stop with power saver/standby mode facility Yes - Processing Capacity of size 356mm x 432 mm in 90 second mode Yes - Instruction manual supplied with Equipment Yes - accessories Chemicals/Material for running Equipment for minimum one month na - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Amit Prakash N 110052
Kokiwala Bagh
Ashok Vihar
Phase IV 1300 15 EMD Required No ePBG Required No
90315
GEM/2018/B/12886
medical x ray film processing chemical kit
15 days
Delhi; North Delhi
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| medical x ray film processing chemical kit Medical X Ray Film Processing Chemical Kit ( 1300 ) Technical Specifications Specification Specification Name Values Allowed Values construction Table Top Automatic Medical X ray Film Processor machine Yes - Machine Assembly made up of material non corrosive Yes - Length of Machine 8 - Width of Machine 8 - Height of Machine 8 - Rollers Mechanism Motrised - Auto washer Yes - Auto Dryer Yes - Auto Developer Yes - Rollers Material PVC with inner pipes of SS-304 Grade - Material of Cabinet ABS Plastic - Weight (Empty) 250 - Auto Fixer Yes - Automatic Replenishment Yes - certification & test report Radiology Certificate for Processed Film na - 1/4 High Voltage Test 1-5 KV for I minute Yes - Certification na - Availibility of Type Test Report (to be furnished by Seller to Buyer on demand)for performance test false - Test Report number & Date na - Name & Address of Laboratory na - features Continious film roller transport and auto start and stop facility Yes Rigid PVC | - | - | - |
| Yes Minimum Film size length (mm) x Width (mm) 100 x 100 - Maximum Film size length (mm) x Width (mm) 356 x 432 - Water Filter Compatible with equipment supplied with equipment Yes - Dryer Temprature(maximum) (degree 70 - Minimum Capacity of Fixer | - | - | - |
| Washer and Developer Tank 5 - Operating Temp Range (degree) (28-37) Degree - Processing Time: 90 sec to 200 sec in steps of six second with LED Display Yes - Maximum Power Consumption (kwh) 0 Mimimum capacity of Replenishment Developer and Fixer Tank with overflow drain facility 25 - Minimum Insulation at 500 V DC na - Developer and Fixer Temprature adjustable Yes - 2/4 throught automatic temprature controller Compatible to Power Supply 220-240 volt | - | - | - |
| AC | - | - | - |
| 50Hz - Manual | - | - | - |
| Auto Stop with power saver/standby mode facility Yes - Processing Capacity of size 356mm x 432 mm in 90 second mode Yes - Instruction manual supplied with Equipment Yes - accessories Chemicals/Material for running Equipment for minimum one month na - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Amit Prakash N 110052 | - | - | - |
| Kokiwala Bagh | - | - | - |
| Ashok Vihar | - | - | - |
| Phase IV 1300 15 EMD Required No ePBG Required No | - | - | - |
Exempted
25 May 2018
15 May 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_90315.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .