Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹5,151
Closing Date
28 Oct 2024, 1:00 pmClosed
S.E, EUCC-V, LESA, Cis-gomti,Lucknow
Room No.61, LESA Bhawan Near Residency Park, Kaiserbagh, Lucknow.
As per tender specification
2024_MVVNL_962179_1
06/EUCC-V/LESA/2024-25
Open Tender
Electrical Works
30 days
33/11 Kv S/s Kakori
As per tender specification
2 documents required · 2 mandatory
₹1,180
A/c. No. 10101985364, IFSC CODE No.SBIN0003347,SBI
₹5,151
21 Nov 2024
5 Oct 2024
28 Oct 2024
5 Oct 2024
28 Oct 2024
5 Oct 2024
Amount
Safe Dragging, loading, carriage and unloading of following store materials with proper stacking from ESC Daliganj to JE dump store and JE dump store to work site within municipal areas.
11 KV 3x300 Sqmm XLPE cable
11 KV Cable Jointing Kit O/D
11 KV Cable Jointing Kit I/D
L.T XLPE Cable 1x630 sq.mm
33 KV Current Transformer 200/100/1-1/ A
Battery charger 24 Volt
Battery set 24 Volt
33 KV Control Pannel single circuit Transformer
Copper Control Cable 2x2.5 Sq. mm.
Copper Control Cable 4x2.5 Sq. mm.
Copper Control Cable 6x2.5 Sq. mm.
Dismantling of 33/11 KV 5 MVA power transformer by opening of jumpers of HV side, LV side 11 kV cable of 5 MVA T/F and earthing strip of T/F neutral bracket & 11 KV cable stand.
Removal & refixing of existing 11 KV Side Cable Stand with proper concreting / grouting as per Norms
Removal & refixing of existing nutral Stand with proper concreting / grouting as per Norms
Safe dragging of 5 MVA T/F from plinth to a safe place in/out the switch yard
Erection, commissioning and complete Testing of 10 MVA T/F with mounting of radiators & conservator tank, filling of T/F oil, complete wiring and other associated work .
Connecting 10 MVA Power Transformer to 33 KV & 11 KV line & jumpering by 1x630 Sqmm. cable including with fixing of connector & Al. lugs (Required connectors, PG clamps & Al. lugs/L-pices will be provided by contractor).
Minor Repairing of existing Power Transformor Plinth and switch yard area after commissioning of 10 MVA T/F
Hoisting of 11 KV 3x300 sq mm XLPE Cable at cable stand and in 11 KV VCB Pannel with complete work
Pipe boring type Earthing minimum 20 mtr deep from ground lavel or upto water level with ‘B’ class G.I. Pipe 2“ dia connection of equipments with earthing/strip included in the job as per norms for Transformer /other requried equipments.
Laying of Single 11 KV, 3x300 sq mm XLPE cable in constructed Trench
Laying of Single 11 KV, 3x300 sq mm XLPE cable in normal soil by digging of trench of suitable size & it's boxing with brick & sand and properly levelling & ramming after laying of cable etc. (All required materials will be provided by contractor except 11 KV cable)
Laying of copper control cable of following sizes its proper dressing ,ferruling and connection with the system in exsting control cale tranch in swithc yard to control room with proper cleaning trench (All required materials will be provided by contractor except control cable )
Copper Control Cable 2x2.5 Sq. mm.
Copper Control Cable 4x2.5 Sq. mm.
Copper Control Cable 6x2.5 Sq. mm.
Mounting of accessories/equipment on existing fabricated structure complete work with making proper alignment and tightening the work includes fabrication work if required for proper operation of equipment .(All required materials connectors lugs nut & bolts etc. will be provided by contractor except CT )
Dragging of control panel /T/F control pannel from unloading place upto control room and placement, erection with stand commissioning & complete testing of the same as per RESPO Norms (All required materials will be provided by contractor except T/F control pannel)
Supply & erection of Copper Bond 0.5 Mtr. Long 65x8mm suitable for 10 MVA T/F (All required materials will be provided by contractor )
Erection of Battery Charger 24 Volt & Battery Set on stand As per Norms (All required materials will be provided by contractor except battery & Battery Charger)
Testing of All equipment/control cable
Balance Recived material from site & its carriage with proper stocking to LESA Store & other misc. work
S.R. ENTERPRISES (BID ID -4689229)
ARIHANT ELECTRIC COMPANY (BID ID -4665750)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx