Rural Development and Panchayat Raj Department
EE PRE DIVISION KOPPAL
CONSTRUCTION OF COMPOUND RCC REAPIRS ELECTRIFICATION PLUMBING SEILING TILES AT PRIMARY GOVT HOSPITAL AR UPA KENDRA IN GUNDUR VILLAGE IN KARATAGI TALUKA
RDPR/2026-27/OW/WORK_INDENT29338
RDPR/2026-27/OW/WORK_INDENT29338
Reserved
Other Works
Electronic Documents, First(One Cover)
RDPR Division Office Koppal
11 documents required · 11 mandatory
₹500
₹6,000
12 Nov 2026
12 Nov 2026
16 Nov 2026
CONSTRUCTION OF COMPOUND RCC REAPIRS ELECTRIFICATION PLUMBING SEILING TILES AT PRIMARY GOVT HOSPITAL AR UPA KENDRA IN GUNDUR VILLAGE IN KARATAGI TALUKA
Chipping unsound weak concrete material from slabs. Beams, columns & roofs upto 50mm by manual means or by standard power driven percussion type including cleaning reinforcement with ...
polyurethane based single Component for New surface - Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrac...
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt...
Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mor...
Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes...
Repairs to plaster in patches of 2.5 m2 and less in walls, ceilings 10 to 20mm thick in cement mortar 1:4 including cutting the patches in proper shape and replastering the surface of the wall includi...
Distempering with dry distemper of approved brand and manufacture (two coats) of required shade on new work, over and including water thinnable priming coat to give an even shade after thoroughly broo...
Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2...
Providing and Fixing Fly Proof Wiore guaze top windows clerestory windows and doors with MS Flat 15x3 mm and nuts and bolts complete Galavanised MS Wire guage with 0.63 mm dia wire and 1.4 mm aperture...
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe wi...
ELECTRIFICATION
Supplying heavy gauge PVC conduit pipe . dia . mm thick
confirming to IS 2509 with suitable size bends, junction boxes,
adhesive paste etc , and fixing using inverted wood plugs in case of
Supplying heavy gauge PVC Conduit Pipe . dia . mm thick
with suitable size bends, metal junction boxes adhesive paste etc., by
groove cutting in the wall and fixing by bracing U or J hooks and
Supplying and flush mounting teak wooden box without front plank,
made of not less than 12 mm thick wood, after due groove cutting,
finishing with necessary cement plastering complete.12" x 12" x 3" (...
Supplying and fixing superior quality modular switch mounting
polycarbonate plate with necessary supporting back plate with required
nos. of machine screws, bolts nuts etc., complete on the existing
Supplying and wiring adopting loop system in existing PVC
Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) &
1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated
copper wire (confirming to...
Supplying and wiring adopting loop system in existing PVC
Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) &
1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated
copper wire (confirming to...
Supplying and wiring adopting loop system in existing PVC
Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) &
1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated
copper wire (confirming to...
Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS...
Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS...
Supplying 4mm thick plastic sheet with necessary nitches for
fixing switches, regulators etc, and fixing on existing wooden or
metal box using N.F. screws
Supplying 6A flush type socket and 6 A flush type SP switch either
surface/flush mounting in existing gang box or in 4mm thick plastic
sheet and fixing over a flush mounted wooden box and wiring using...
Supplying and fixing surface/flush mounting unbreakable PVC
modular box suitable for mounting modular switch plates with due
groove cutting in Brick/C.C wall, including necessary rawl plugs,
Supplying And fixing/replacing of 6/16/32A electrical
accessories on existing switch board.6A SP Switch
Supplying and fixing of slim box fitting, made out of CRCA Sheet
metal body with locking type holder completely wired. Excluding
Ballast & Fluorescent Tube.1 x 4' Tube light fitting.
Supplying and fixing regular MCB distribution boards on wall/ood
board / flush mounting using required clamps, bolts, nuts etc., with
provision for fixing suitable type capacity MCB's single phase/3
Supplying capacitor type ceiling fan complete with down rod blades,
shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase
AC supply conforming to ISS-374- 1979 and with double ball be...
Fixing all types and all capacities of fluorescent /false ceiling / spot
light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders
using 23/0.0076" twin twisted PVC insulated wires, r...
Fixing a ceiling / Wall mounting fan of all capacities and all types to
the existing 'S'' hook with fan regulator to the existing board together
with supplying and fixing 5 A. ceiling rose, necessary ...
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
KW 1.docx
Tender Document • 0.08 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .