Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.5 LAccepted-AOC NOT FOUND | L1 | Accepted-AOC L1 | |
| 2 | L2₹12.5 L+₹81,079 (6.95%)Rejected-AOC 660 POLICE LINE AREA HISAR HARYANA 125001 | HISAR | HARYANA | 125001 | L2 | Rejected-AOC L2 |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
25 Sept 2021, 6:00 pmClosed
CWE
HQ CWE AF Bhisiana
Repair/ Maint/ Improvement of VCB, RMU alongwith allied HT infrastructure at AF Station Sirsa
2021_MES_471864_1
CWE(BHI)/SIR-34/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
AFS Sirsa
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE AF Sirsa
₹50,000
Yes
14 Oct 2021
31 Aug 2021
27 Sept 2021
31 Aug 2021
25 Sept 2021
13 Sept 2021
1 Sept 2021 - 8 Sept 2021
Amount
Disconnecting & Taking down/out Serviceable/ unserviceable HT XLPE Cable 11 KV of size 70 Sqmm to 120 Sqmm 3 core of any description and checking for fault rectification from Trenches, Floors, Walls, GI Pipes, etc., seggrating Serviceable Cables, Pipes, Bricks, etc. including keep in Safe Custody for re-use and unserviceable Cable removing to and depositing at AGE E/M STORE YARD, complete all as specified and as directed. NOTE : (i) Any damage/punchred into HT cable the contractor will be responsible. (ii) Before Laying meggaring the complete cable in presence of Engr-in-charge. (iii) Any damage of HT cable the contractor will be responsible. The contractor will have to supply new cable of same size and specification in lien of old cable without any extra cost.
S&F XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured (Earthed), electric power cables (heavy duty) with aluminium conductor, 11000 volts, grade cross sectional area 95 Sqmm 3 core complete all as specified and as directed.
Relaying XLPE Under Ground Cable (Serviceable Cable obtained from Item No. 1.0 here-in-before) 11000 Volt grade, Cross sectional area 70 Sqmm to 120 Sqmm, 3 Core including Jointing and Testing, complete all as specified and as directed.
M&L for replacement of Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and as directed.
M&L for replacement of Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and as directed.
M&L for replacement of Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and as directed.
M&L for replacement of Cable jointing kit for 33 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 300 sqmm complete all as specified and as directed.
Excavation in trenches manually not use a JCB not exc 1.5 m wide and not exceeding 1.5 m depth for foundation laying of cables etc and getting out in soft loose soil all as specified and directed.
Excavation in trenches manually not use a JCB not exc 1.5 m wide and not exceeding 1.5 m depth for foundation laying of cables etc and getting out in Hard soil/ Road/ Path etc complete all as specified and directed.
Returning filling including spreading leveling watering and well ramming in layers n.exc 25 cm in soil completed all as specified and directed.
Removing excavated material n.exc 50 m and depositing where directed at a level n.exc 1.5 mtr above the starting point as in soil complete all as specified and directed.
M&L dry river sand as in sand cushioning to under ground cable including punning down all as directed.
M&L taking out of dry river sand from trenches for fault rectification of cable, refilling in trenches and sand cushioning to under ground cable including punning down all as directed.
Supply and laying un-reinforced precast concrete cable cover, class HVP, type 1 with peak, size 300mm x 180mm x 40mm complete all as specified and directed.
M&L for taking out old precast concrete cable cover of any type and any size and relaying serviceable precast concrete cable cover complete all as specified and as directed.
M&L for making of bore to road link width for providing GI Pipe upto110mm dia for passing armoured cable complete all as specified and directed.
M&L for replacement of Galvanised Steel Tubing Pipe 80mm bore (dia), light grade with Bend, laid in Trenches or under Roads/ Flooring/ Culverts and/or fixing to Electric Poles with suitable size Mild Steel Flat Iron Clamps, Bolts, Nuts, Washers, etc., complete all as specified and as directed.
M&L for disconnecting of all HT/Earthing/AC/DC connections of existing VCB 11 KV carefully and shifting the VCB for making good of ducts with all accessories to the another location at Air Force Station Sirsa including Jhopra and making all HT/Earthing/AC/DC connections and testing complete all as specified and as directed. Note:- (i). If any damage occurred of VCB during shifting of VCB 11 KV then contractor will be responsible for repair of VCB without any extra cost with original materials of OEM.
M&L for Servicing of Vacuum Circuit Breaker 400/630/800 Amps 11 KV with taking out of trolley from cabinet and opening top cover, de-carbonizing moving and fixed contacts, lubricating, inspecting the wiring of Micro processor Earth Fault and Over Current relays, tripping coil electrical, indication systems, metering systems and checking for manual/auto tripping system, meggaring all the contacts and placing back the breaker trolley in its original position including removing all the dust form the VCB cabinates complete all as specified and directed. Note:- (i). All Vacuum Circuit Breaker are 11 KV of Capacity 400/630/800 Amps. (ii). Make of Vacuum Circuit Breakers are Yamuna Power/ ABB/ CG/ ITE/ SIEMENS.
M&L for Replacement of fixed contact block complete suitable for Vacuum Circuit Breaker 11 KV of capacity 400/630/800 Amps of Make Yamuna Power/ ABB/ CG/ ITE complete all as specified and as directed.
M&L for Replacement of moving contact block complete suitable for Vacuum Circuit Breaker 11 KV of capacity 400/630/800 Amps of Make Yamuna Power/ ABB/ CG/ ITE complete all as specified and as directed.
M&L for Replacement of mechanical castle interlock assembly with key suitable for Vacuum Circuit Breaker 11 KV of capacity 400/630/800 Amps of Make Yamuna Power/ ABB/ CG/ ITE complete all as specified and as directed.
M&L for Replacement of closing coil assembly 230 volts AC/ 24 volts DC suitable for Vacuum Circuit Breaker 11 KV of capacity 400/630/800 Amps of Make Yamuna Power/ ABB/ CG/ ITE complete all as specified and as directed.
M&L for Replacement of Tripping coil with plunger assembly 230 volts AC/24V DC suitable for Vacuum Circuit Breaker 11 KV of capacity 400/630/800 Amps of Make Yamuna Power/ ABB/ CG/ ITE complete all as specified and as directed.
M&L for Replacement of closing coil plunger with 24 volts DC suitable for Vacuum Circuit Breaker 11 KV of capacity 400/630/800 Amps of Make Yamuna Power/ ABB/ CG/ ITE complete all as specified and as directed.
M&L for Replacement of spout bushing suitable for Vacuum Circuit Breaker 11 KV of capacity 400/630/800 Amps of Make Yamuna Power/ ABB/ CG/ ITE complete all as specified and as directed.
M&L for Replacement of Canister Assembly suitable for Vacuum Circuit Breaker 11 KV of capacity 400/630/800 Amps of Make Yamuna Power/ ABB/ CG/ ITE complete all as specified and as directed.
M&L for Replacement of HT 11 KV PT HRC Fuse suitable for Vacuum Circuit Breaker 11 KV of capacity 400/630/800 Amps of Make Yamuna Power/ ABB/ CG/ ITE complete all as specified and as directed.
M&L for Replacement of HT 33 KV PT HRC Fuse suitable for Vacuum Circuit Breaker 11 KV of capacity 400/630/800 Amps of Make Yamuna Power/ ABB/ CG/ ITE complete all as specified and as directed.
M&L for Replacement of Vacuum interrupter suitable for Vacuum Circuit Breaker 11 KV of capacity 400/630/800 Amps of Make Yamuna Power/ ABB/ CG/ ITE complete all as specified and as directed.
M&L for Replacement trip push button suitable for Vacuum Circuit Breaker 11 KV of capacity 400/630/800 Amps of Make Yamuna Power/ ABB/ CG/ ITE complete all as specified and as directed.
M&L for Callibration of microproccessor E/F and O/C relay of VCB complete and calibrating with portable relay test kit to set time and fault level and adjustment of setting with according to load & time with Dakshin Haryana Bijli Board for proper functioning complete all as specified and directed.
M&L for Replacement of bakelite kit kat with 2/5/10 amps HRC fuse suitable for Vacuum Circuit Breaker 11 KV of capacity 400/630/800 Amps of Make Yamuna Power/ ABB/ CG/ ITE complete all as specified and as directed.
M&L for Replacement of indicator lamp LED 110 Volt AC with holder (R/Y/B in colour) suitable for Vacuum Circuit Breaker 11 KV of capacity 400/630/800 Amps of Make Yamuna Power/ ABB/ CG/ ITE complete all as specified and as directed.
M&L for Replacement of indicator lamp LED 24 Volt DC with holder (R/Y/B in colour) suitable for Vacuum Circuit Breaker 11 KV of capacity 400/630/800 Amps of Make Yamuna Power/ ABB/ CG/ ITE complete all as specified and as directed.
M&L for Replacement of shunt trip coil 24 to 30 volts DC suitable for Vacuum Circuit Breaker 11 KV of capacity 400/630/800 Amps of Make Yamuna Power/ ABB/ CG/ ITE complete all as specified and as directed.
M&L for Replacement motor and gear assembly 110 volts AC/24V DC suitable for Vacuum Circuit Breaker 11 KV of capacity 400/630/800 Amps of Make Yamuna Power/ ABB/ CG/ ITE complete all as specified and as directed.
M&L for Replacement TNC switch of capacity 25 Amp, 2NO + 2NC with barrel lock suitable for VCB 11 KV of capacity 400/630/800 Amps of Make Yamuna Power/ ABB/ CG/ ITE complete all as specified and as directed.
M&L for Replacement of isolating contact assembly suitable for Vacuum Circuit Breaker 11 KV of capacity 400/630/800 Amps of Make Yamuna Power/ ABB/ CG/ ITE complete all as specified and as directed.
M&L for Replacement of Sealed Maintenance Free/ Valve - Regulated Lead-Acid Battery 2 Volt 100 AH, Rechargeable type, complete all as specified and as directed.
M & L Replacement of Battery Charger suitable for battery bank 24 volts 15 Amp with auto cut of, complete all as specified and as directed.
M&L for Replacement of Power pack with battery backup 24 Volt DC & connected to HT PT secondary circuit including testing for triping complete all as specified and as directed.
M&L for servicing of battery bank installed at 11 KV sub stations by opening top cover, checking of batteries, cleaning of terminals and top up distilled water complete and checking meters complete all as specified and directed.
M&L for preparation of old painted surface of steel by brushing and painting with spray painting one coat with metallic paint to HT VCB Panel and marking /lettering of SM/ MES Number complete all as specified and as directed.
M&L for repairing of three phase over current and earth fault relay including electronic circuit for HT 11 KV VCB panel including testing on complition complete all as specified and as directed.
M&L for Replacement of Multi Function Meter LCD Display with Parameters - Amp, Volt, Freq, PF, RPM, %Load, %Unbal, Amp phase angle, Maximum Demand with RS-485 including necessary wiring required at site, complete all as specified and as directed.
M&L for Servicing of Ring Main Unit 400/630 Amps 11 KV with opening front cabinets and de-carbonizing moving and fixed contacts, lubricating, inspecting the wiring of Micro processor Earth Fault and Over Current relays, tripping coil electrical, indication systems, metering systems and checking for manual/auto tripping system, meggaring all the contacts with replacement of complete wiring with existing size copper conductor cable and colour coding and removing all the dust form the Ring Main Unit cabinates complete all as specified and directed. Note:- (i). All Ring Main Units are 11 KV of Capacity 400/630 Amps. (ii). Make of Ring Main Units are ABB/ CG/ SIEMENS.
M&L for Replacement of plug in voltage presence indicator system 3 Phase (VPIS) type WIM for Ring Main Unit SF-6 of capacity 11 KV, 630 Amps of Make ABB complete all as specified and as directed.
M&L for Replacement of fuse assembly by opening fuse canisters of RMU positioned behind interlocking cover for Ring Main Unit SF-6 of capacity 11 KV, 630 Amps of Make ABB complete all as specified and as directed.
M&L for Replacement of Bushing assembly for Ring Main Unit SF-6 of capacity 11 KV, 630 Amps of Make ABB complete all as specified and as directed.
M&L for Replacement of terminal contact piece with silicone coupling by opening the terminal cover for Ring Main Unit SF-6 of capacity 11 KV, 630 Amps of Make ABB complete all as specified and as directed.
M&L for Replacement of gear assembly grooved inside and outside for operating of Ring Main Unit SF-6 of capacity 11 KV, 630 Amps of Make ABB complete all as specified and as directed.
M&L for Replacement of Operating Handle for Ring Main Unit SF-6 of capacity 11 KV, 630 Amps of Make ABB complete all as specified and as directed.
M&L for Replacement of SF-6 gas in safe ring/safe plus by SF-6 gas bottle by removing front cover and on screw manometer and reduction valve and maintained the pressure 14 bar obslute for Ring Main Unit SF-6 of capacity 11 KV, 630 Amps of Make ABB complete all as specified and as directed.
M&L for Replacement of Trifurcation boot 11 KV capacity for cable termination joint of RMU incoming and outgoing terminals including taking out old defective trifurcation boot for Ring Main Unit SF-6 of capacity 11 KV, 630 Amps of Make ABB complete all as specified and as directed.
M&L Cement Concrete 1:2:4 (20mm graded stone aggregate) type B1 around the LT/HT Pole/Bus Bar/LT Panel/Path, 15 Cm thick, complete all as specified and as directed.
M&L for Replacement and pasting of Electrical Insulating Mat 2.5mm thick made out of Dielectric 'Elastomer' which possess elastic properties and may be natural or synthetic in nature. Should have Working Voltage - 11 KV, No tear or breakage due to Trolley movement & Foot Traffic, Resistant to Acids, Alkalis, Solvent and transformer Oil, Pasteable type can be easily pasted/Installed on Floor, Water and Moisture Proof, complete all as specified and as directed.
M&L for Replacement of 3SAFT LS14500 LS 14500 AA 3.6v Li-SOCl2 Lithium Battery complete all as specified and as directed.
S&F in replacement of electronic siren horizontal single stage continuous normal operation for atleast 50 minutes with sound level 65 DB to 120 DB measured at 1.5 Mtr with sound output variation of +5 DB 500 mtrs range.
VERMA BROTHERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .