Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
PROVN OF SHADOWLESS LIGHT AT OT SUIT NO 1 AT CHCC UNDER GE E/M LUCKNOW
2020_MES_357503_1
GE/EM/LKO/HOSP/T-31 OF 2020-2021
Open Tender
Miscellaneous Works
Item Rate
180 days
Lucknow
Class E or above category b (i)
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹28,000
Yes
2 Sept 2020
1 Jul 2020
30 Jul 2020
1 Jul 2020
28 Jul 2020
16 Jul 2020
60 days
Amount
Supply fixing testing and commissioning of Surgical operating LED OT light COMPATIBLE WITH LAMINAR AIR FLOW SYSTEM ceiling hanging type double doom of make - Dr Mach /Dentis/philips/Trilux /Stryker and comprising the following specification (Note - OT light should be provided by OEM with 02 years warranty in any spare parts ) (a) No of dome - 02 Nos connected each other (b) input voltage supply - 100~264Vac, 50Hz (c) out put voltage - 24 DC/V (d) Temp rise - max 2 degree above ambient temp on the operating field (e) diameter of dome - 750 + 750 mm (f) diameter of each light - 300 mm (g) Spring arms stroke -850 mm (h) No of LED -104 nos each dome (j) rated life of LED -40000 hrs (k) light out put - 160000 + 160000 Lux at 1 M of Each dome (l) field size - 250 -380 mm (m) colour temp - 4300 degree kelvin (n) CRI -95 (o) illimination depth - 105 (p) Ceiling & arm rotation -360 degree (q) intensity control - control panel (r) focusing - by sterilizable handle (s) No of LED = 84 Note: OT light shoud be fixing by cutting ceiling of roof and drilling works and painting of hygenic bacteria free paintings outer surface and refixing ceiling old/new and required wiring as suitable in good conditions all as specified and directed by EIC. All cost to fixing of OT light shall be quoted in items rate above by contractor .
Supply & install, comissioning and testing indoor/Outdoor type wall mounted panel made out 3.14mm thick CRCA sheet poweder coated with pretreatment by 8 tank process , CPRI approved having the following complete all as specified &directed by Engr-in Charge . a) TPN, Aluminium bus bar 400 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. b) ATS 400 Amp 4 P, 415 Vots, 50 Hz, Make- Havells cat Pt No- IHYFCDO400. – 1 No c) LED Indicator lamp RYB - 01 set of three. (d) Single phasing preventer Relay voltage , 415 V Ac , 65 V AC asymmetry 3 PHase 3W 1 C/O fail safe type complete Make GIC Cat No- MA51BC - 02 Nos (e) 14 Pinplug in relays- miniature contact rating 6 A(res) at 24 VDC/250 V AC contact 4 C/O , coil voltage 230 V AC with LEd indication & Mechanical indicator with manual testng/latching lever type- ARPM4 make - BCH Cat No- ARPM4 4230 ALE-02 Nos (f) 14 Pin socket screw Terminals, 35 mm DN rail mounting make - BCH Cat No- ARSM14-02 Nos (g) MCB 6A SP 10 KA C Curve Make- Havells cat No- DHMGCSPF006-03 Nos (h) 6 A , SP 2 way Local Remote/ Auto Manual Switch with centre OFF 60 Deg operation Make- salzer Cat No- 61025- 2 Nos
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables, pipes etc. and getting out including trimming the sides and forming bottom surfaces to required levels in soft/loose soil complete all as specified & directed by Engr-in-Charge.
Returning, filling in, including spreading, levelling, and well ramming in layer not exceeding 25 cm thick in soft/loose soil complete all as specified & directed by Engr-in-Charge.
Removing excavated material ( soils) not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified & directed by Engr-in-Charge.
Material and labour for river sand, washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete all as specified & directed by Engr-in-Charge.
M&L laying well burnt old size bricks, sub class "B" bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection complete all as specified & directed by Engr-in-Charge.
Boring/Drilling ( horizontally) manually under existing road ( maximum 10 M in width) suitable for passing GI tubing of 40 to 100 mm bore complete all as specified & directed by Engr-in-Charge.
Supplying and fixing Galvanised mild steel pipe /tubing, of size 40 mm bore dia, light grade complete with all fittings, laid in trenches / under roads, drain, paths, fixed to poles/ walls with Mild steel clamps , bolts , nuts and washers complete all as specified of following bore complete all as specified &directed by Engr-in Charge Note:- Excavation & Earth work, Mild steel clamps, bolts , nuts and washers shall be measured and paid separately.
All as per item No 09 above but 80 mm size
M & Laying, jointing and testing LT under ground electric power cable crossed linked polyethylene ( XLPE) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of size 16 sqmm cross sectional area, 2 core ,complete all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc. with and including MS Clamps, nuts , bolts, washers complete all as specified and directed. Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles/ block and pipe shall be measured and paid separately under appropriate items.
All as per item No 11 above but of size 16 Sqmm 4 core
All as per item No 36 above but of size 25 Sqmm 4 core
All as per item No 36 above but of size 35 Sqmm 3.5 core
All as per item No 36 above but of size 50 Sqmm 3.5 core
All as per item No 36 above but of size 70 Sqmm 3.5 core
All as per item No 36 above but of size 95 Sqmm 3.5 core
Taking out old unsv/ faulty LT under ground cable of any size complete all as specified and as directed by Engineer-in-Charge.
Disconnecting, dismantling and taking down carefully ACSR conductor from poles of any size and setting a side complete all as specified and as directed by Engineer-in-Charge.
Dismantling taking down old cross arms, clamps, braces etc of any section from pole including nuts, bolts, washers complete all as specified and as directed by Engineer-in-Charge.
Dismantling of insulators any type and any size complete all as specified and as directed by Engineer-in-Charge.
Dismantling of GI wire any type and any size complete all as specified and as directed by Engineer-in-Charge.
Dismantling of stay assembly any type and any size complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing Switch Fuse Unit/Fuse switches Triple pole neutral Link, of capacity 100 Amp 415 Volt, 50 Hz complete all as specified &directed by Engr-in Charge
Supply, installation, testing and commissioning out door type Busbar panel board made out of 3.15 mm thick MS sheet and MS angle section 40x40x5 mm on PCC 1:2:4 type B-1 platform 40 cm above the ground level and 45 cm below the ground level, complete all as specified &directed by Engr-in Charge a) TPN, Aluminium bus bar 200 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. b) Incoming MCCB 200 Amps 36 KA, 415 Vots, 50 Hz, FP. – 1 No c) LED Indicator lamp RYB - 01 set of three.
Supply & fixing wall mounted Busbar Chamber Box 8 Way 200 Amp Rated with sheet metal enclosure including TPN, Aluminium bus bar 200 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. complete.all as specified and as directed by Engineer-in-Charge.
Supply & fixing of automatic street light switch using Infrared Sensor based for automatic switching of street lights based on LUX level of natural light. Required illuminance for switching ON is < 30 Lux and for switching OFF > 10 Lux level. The sensor (nature switch) alongwith suitable power contactors, Input (supply) MCB and output (load) MCB(s), support terminals should be enclosed in pole/ wall mountable enclosure made of rust proof, electric shock proof, termite proof and FR graded SMC junction box conforming to IP-54 degree of ingress three phase 8 KW lightening load capacity Complete all as directed by engr-in-charge
M&L Earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI strip 32 x 6 mm as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS TMT bars 8mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed and testing on completion. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
S&F Energy Efficient integral LED Street light fitting 60 watt having IP 66 protection, Class-I, IK protection - IK07, with 10 KV Build in surge protector mounting on suitable for 40 mm brackets as fixed with pole complete all as specified and directed by Engr-in Charge
Supply and fixing LED Flood light 120 W die cost aluminium IP 65 with high power LED as light source complete all as specified &directed by Engr-in Charge
S&F in repair flat twin core ,10 sqmm nominal cross sectional area multistranded aluminium conductor cable, over all PVC sheathed, 1100 Volts grade heavy duty cable complete including PVC Pipe 25 mm with accessories such as socket tee , elbow complete all as specified &directed by Engr-in Charge
All as per item No 36 above but 30 but 4.0 sqmm twin core.
All as per item No 36 above but 30 but 6.0 sqmm twin core.
Disconnecting the existing cable from Panel / Pole, preparing the end for jointing including all earth work, Supply and fixing Cable end termination heat shrinkable joint inclding sleeves suitable for LT XLPE cable of size 3.5 core 16 to 50 sq mm complete all as specified &directed by Engr-in Charge
All as per item No 36 above but size 70 to 120 sq mm
Disconnecting the existing cable from Panel / Pole, preparing the end for jointing including all earth work, Supply and fixing straight through heat shrinkable joint suitable for LT XLPE cable of size 3.5 core 16 to 50 sq mm complete all as specified &directed by Engr-in Charge
All as per item No 36 above but size 70 to 120 sq mm
Supply & Fixing in replacement , transporting, erecting Steel tubular swaged poles type 410 SP-31 ( 9.0 metres long) complete with cast iron base plate, finial, taper plug, bolts, nuts and screws as specified, including necessary excavation and earth work , PCC 1:4:8 type D2 in foundations below pole, PCC 1:3:6 type C2 around poles and PCC 1:3:6 type C1 as in plinth block , disposal of surplus soil to a distance not exceeding 50 m and depositing where directed, painting steel tubular poles exposed surafces with Aluminium paint two coats over one coat of red oxide primer and providing 300 mm wide bands (3 bands/ straps with synthetic enamel paint and 2 bands with Black bituminous paint ) from plinth block and numbering of poles , painting embedded portion of poles with one coat of bituminous paint complete all as specified &directed by Engr-in Charge
Supply & fixing in replacement GI brackets made of 40 mm nominal bore GI pipe medium grade of required length not less than 1.5 M long, mounting brackets made out of Mild steel FI 40x6 mm of required shape ( two Nos) duly fitted with Mild steel nuts, bolts and washers and painting with two coats of synthetic enamelled paint over one coat of red oxide Zn chrome primer and fixed to pole / walls etc complete all as specified &directed by Engr-in Charge
S&F MS Junction Box made of 1.6 mm thick MS sheet of size 300mmx200mmx150mm complete with front openable hinged cover and locking arrangements with 4 Nos aluminium bas bar 100 Amps, mounted on porcelin insulator including M&L for MCB SP 10-1No, fixed on box in Din rail complete with electrical connection fixed to pole with suitable size FI clamp nut bolts and washer including duly painted with powder coated paint complete complete all as specified &directed by Engr-in Charge
Cleaning the existing painted surface of LT panel by scrapping, making good distrubed surfaces by applying putties on uneven surface to make it even and M&L for spray painting to LT panel of any size with two coat of synthetic enamel paint with desired colour over one coat of red oxide primer complete all as specified and directed.
Material and labour for maintenance of feeder pillar/LT panel indoor/outdoor type Panel by cutting corroded MS lid from LT panel, and weilding the same with 2 mm thick MS sheet in any desired shape including removing the carbonized/melted sparked thimbles, cleaning the carbonized bus bar making cable ends clean and replacement of following unserviceable parts with new nut bolts and washer comlete all as specified and directed by Engr- in- Charge
Supply & fixing Multifunction meter complete all as specified and directed by Engr- in- Charge
Supply & fixing LED Indicator lamps complete all as specified and directed by Engr- in- Charge
m/s pal associates
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .