Executive Engineer MHD, Srinagar
Office of Executive Engineer, Mechanical Hospital Division Srinagar
Supply, Installation, Testing and Commissioning of Mist based Fire Fighting System at Forensic Science Laboratory Bemina, Srinagar
2023_PWDJK_228142_1
MHDS/TS /2023-24/81/e-tendering dt30-08-2023
Open Tender
Machineries/ Mechanical Engg Items
Item Wise
60 days
Forensic Science Lab Bemina
As detailed in NIT
6 documents required · 6 mandatory
₹3,000
Executive Engineer MHD SGR
₹1.6 L
Office of Executive Engineer, MH Division Srinagar
3 Oct 2023
30 Aug 2023
16 Sept 2023
30 Aug 2023
16 Sept 2023
2 Sept 2023
31 Aug 2023 - 7 Sept 2023
2 Sept 2023
Amount
Supply, Installation testing & Commissioning of Watermist Based Hydrant System. It should be self contained standalone firefighting device, suitable for locations with no ready supply of compressed air and water. It should be easy-to-use system features an in-built pressure container, water storage unit and an Optional foam supply unit. Effective use of water: It should convert 100% into mist, which evaporates in the fire environment Fighting larger fires: It shall ensure 3 times further reach than normal Watermist hydrants that emit droplets of 100 - 150 microns by converting water into small droplets of less than 40 microns.. Thermal barrier: The mist's cross section of water droplets shall create a barrier against radiation. Classes of fire: It shall work on all classes of fire as well as electrically started fires. Compatible: It shall conduct no electricity (up to 35kV) and can be safely used on electrically started fires. Hence compatible with electronic equipments. Safe on people: The mist shall be made of water or inorganic salt solutions and does not harm people or the environment. Easy on the environment: The mist generated by these firefighting systems shall be 100% non toxic and ecofriendly. Length Of Fire Hose should be 30m Nitrogen Gas Cylinder Capacity of 60 L (minimum) Nitrogen Gas Pressure 300 bar Water Tank Capacity 60 L( minimum) Foam tank capacity 5 ltrs (minimum)
Providing of water mist and CAF fire extinguisher low pressure trolley mounted. The Trolley mounted configuration shall have water tank, compressed air cylinder and gun mounted on a free moving trolley provided with strong wheels as specified in DIN EN 1866-1:2007-08 Standards. Trolley mounted shall be supplied with two air cylinders of 6 lt capacity. Pressure vessel to hold the media with safety valve, Compressed air cylinder couped with a reducer, Hose pipes for discharge of water mist media, Extinguishing gun. Fire Rating for Trolley Mounted II B and Di Electric. With marking of Fire Class A amp; B as per EN 3-7 Standard. Pressure vessel of capacity 50 Its
DIRECTEL ADVISORY PRIVATE LIMITED
BARIAR ESTATE PVT.LTD
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .