| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹77,551Accepted-AOC AT PO DAKRA PS KHALARI DISTT RANCHI JHARKHAND 829210 | DAKRA | RANCHI | JHARKHAND | 829210 | L1 | Accepted-AOC The L1 bidder is techno-commercially eligible and the rate quoted is reasonable and justified, which has been accepted by the Competent Authority, NK Area. | |
| 2 | L2₹83,210+₹5,659 (7.30%)Rejected-Finance ANAND NAGAR KAMRE RATU ROAD RANCHI DIST RANCHI JHARKHAND 835222 | RANCHI | JHARKHAND | 835222 | L2 | Rejected-Finance L2 | |
| 3 | L3₹91,020+₹13,469 (17.4%)Rejected-Finance AT DAKRA PO DAKRA KHELARI DISST RANCHI JH PIN 829210 | DAKRA | RANCHI | JHARKHAND | 829210 | L3 | Rejected-Finance L3 |
Tender Value
₹84,070
EMD Value
₹1,100
Closing Date
1 Apr 2023, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SO EnM NK
GM Office, NK Area
Repair and maintenance of damaged internal electrical wiring of RCMU Office in Central Colony and B/03 Dakra under GM Unit, NK Area.
2023_CCL_276218_1
GM (NK)/EnM/e-NIT/2022-23/ 273
Open Tender
Electrical and Maintenance Works
Item Rate
10 days
GM Unit, NK Area
As per NIT
2 documents required · 2 mandatory
₹1,100
30 Apr 2023
21 Mar 2023
3 Apr 2023
22 Mar 2023
1 Apr 2023
22 Mar 2023
22 Mar 2023 - 29 Mar 2023
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group B
Supplying and fixing metal box of 150 mm X 75 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required (For light plugs to be used in non residential buildings).
Supplying and fixing metal box of 180 mm X 100 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 and 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as required
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc as required. 32 Amp TP&N.
Supplying and fixing DP sheet steel enclosure on surface / recess along with 25/32 amps 240 volts “C” curve DP MCB complete with connections, testing and commissioning etc. as required.
Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 x 4 sq. mm + 1 x 4 sq. mm earth wire.
Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire.
Supplying and fixing following piano type switch / socket on the existing switch box / cover including connections etc as required. 5/6 amps switch.
Supplying and fixing following piano type switch / socket on the existing switch box / cover including connections etc as required. 3 Pin 5/6 amp socket outlet.
Supplying and fixing brass batten / angle holder including connection etc as required.
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box / wooden block including connection etc as required.
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc as required.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel / PVC conduit as required. 2 x 6 sq. mm
Total impact of GST for the purpose of CTC
M/S OM ENTERPRISES
M/S MANOHAR KUMAR KESHARI
stage.html
html • 0.04 MB
techsummary_285952.pdf
PDF • 0.22 MB
finsummary_285952.pdf
PDF • 0.89 MB
AOC_273.pdf
PDF • 1.41 MB
finance_285952.pdf
PDF • 0.22 MB
BOQ Comparative Chart
xlsx • 0.01 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .