Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹15.8 LAccepted-AOC | 1 | Accepted-AOC Being L-1 | |
| 2 | 2₹18.2 L+₹2.4 L (15.1%)Rejected-Finance | 2 | Rejected-Finance Being other than L-1 |
Tender Value
₹14 L
EMD Value
₹28,000
Closing Date
1 Oct 2022, 6:30 pmClosed
Col Sharath Ravindran CWE
HQ CWE (AF) Chakeri Pin-208008
PROVN OF FIRE PROTECTION SYSTEM FOR STORES AT 24ED UNDER AGE (I) MANAURI
2022_MES_545259_2
CA No.CWE(AF)/CHK/MNR/T-22 OF 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
AGE (I) Manauri
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
AGE (I) AF Manauri
₹28,000
11 Oct 2022
16 Sept 2022
3 Oct 2022
16 Sept 2022
1 Oct 2022
16 Sept 2022
Amount
Supply, Installation, testing and commissioning of floor/surface mounting addressable microprocessor fire alarm control main control with BS EN 54 and indicating panel sounder circuits complete with LCD Display with back light illumination autodialler and push button to acknowledge alarm, testing and reset suitable for operation 230 volts single phase 50 Hzs AC supply 24 V DC supply with suitable capacity charger maintenance free batteries and battery charger including painting labeling earthing etc compatible with detector for communication to detectors and response indicators together with mimic diagram made on Auto CAD and pasted on acrylic sheet with data logging facility and 2 x 16 character LCD, confirming to IS : 2189 and BSEN 54 of capacity from 99 detector and 99 module devices upto 200 detector single loop 6*4' character 2 sounder circuits PTR requires network card and modules (per each loop) with PA based evacuation system with its own stand by power backup supply with batteries, battery charger incl an auto dialling facility and potential No and NC contacts and a 80 watts PA amplifier and capacity not less than 8 zones etc incl making all connection and fixing accessories complete all as specified and directed. (Make : HONEYWELL model : DXc2-714/001/225 or equivalent in Edwards/Siemens/Ravel/Hochiki/Advance including PA based evacuation system comprising of monitor console with on/off, Volume control, switches, Fuse indication with 45 watts main Amplifier of make as recommended by OEM hand held mike enclosed in MS fabricated out of CRCA sheet suitable for work on 230 V AC and 24 VDC power supply along with battery charger with 2 x 12 v x 7 Ah sealed lead acid maintenance free batteries including making all connection and fixing accessories complete all as specified and directed by Engr-in-Charge. Note :(a) Quoted rate shall include cost of batteries (in qty, rating capacity) with suitable rating charger and GI angle factory made battery stand as per original manufacturer instructions.
Supply, Installation, testing and commissioning of addressalbe sensor type certified to EN 54 part 1, 58 degree addressable type microprocessor based, programmable intelligent type, blue light rate of rise thermal (Heat) detector with detector base, advanced protocol and smoothing filter to suppress false alarm, rotary decade switches, in-built isolator, dual Integrated LED for 360 degree visibility, LPCB approved, environment friendly-meets WEEE & RoHS legislative requirements, operating voltage 15 to 32 Vdc complete including necessary connection all as specified and directed. Make : Honeywell cat part No MI-FHSE-S2-IV and detector base cat part No MI-B501AP-IV or equivalent in Edwards/Siemens/Ravel/Hochiki/Advance.
Supply, Installation, testing and commissioning of addressable sensor type certified to EN 45 addressable type microprocessor based, programmable intelligent type, blue light optical smoke detector with detector base, advanced protocol and smoothing filter to suppress false alarm, rotary decade switches, in-built isolator, dual Integrated LED for 360 degree visibility, conforms to EN 54-7, LPCB approved, environment friendly-meets WEEE & RoHS legislative requirements, operating voltage 15 to 32 Vdc complete including necessary connection all as specified and directed. Make : Honeywell cat part No MI-PSE-S2-IV and detector base cat part No MI-B501AP-IV or equivalent in Edwards/Siemens/Ravel/Hochiki/Advance.
Supply, Installation, testing and commissioning of addressable intelligence having inbuilt microprocessor, memory and decision algorithm twin angle with both forward and backward light scattering mechanism cum Photo-thermal multi criteria detector with heat and smoke combination confirms EN54-5 & FN 54-7 LPCB approved make by by Honeywell part code : MI-PTSE-S2-IV/MI-PTSE-S21-IV and mounting detector base cat part No MI-B501 AP -IV or equivalent in Edwards/Siemens/Ravel/Hochiki/Advance.
Supply and fixing of addressable manual call with Box with flush mounting glass box resettable type, unique plug and play installation concept, confirms to EN 54-11, LPCB approved, point break glass type compatible with main fire alarm control board microprocessor based as per IS-2189 and including chain hammer facility and bliking facility complete all as specified and directed. Make : Honeywell Cat part No MI-MCP-FLEX or equivalent in Edwards/Siemens/Ravel/Hochiki/Advance.
Supply, Installation, testing and commissioning of beam master detector with standard transmitter, 10-100 m range, 4 fixed sensitivity levels, 2 automatic variable sensitivity modes, numerical indicators to aid beam alignment, standby, fault and alarm LED indicators, automatic drift compensation, complies EN54-12, LPCB approved alongwith following accessories Beam-LRK, long range reflector kit (70-100m range), BEAM-SMK surface mount accessory, BEAM-MMK multi mount accessories for ceiling or wall mounted with additional mounting adjustment complete all as directed by Engr-in-charge. Make : Honeywell cat Part No MI-LPB2 or equivalent in Edwards/Siemens/Ravel/Hochiki/Advance.
Supply, Installation, testing and commissioning of addressable wall mounting intelligent electronic sounder cum strobe, 32 built-in tones, lower power requirement, optional IP 65 rating, optional built in isolator, Anti tamper feature, CPD approved, LPCB approved in accordance to EN 54 part -3, EN 54 part 17 & CPD including making all connection all as directed by Engr-in-charge. Make : Honeywell cat Part No WSS-PR-NO5 or equivalent in Edwards/Siemens/Ravel/Hochiki/Advance.
Supply, install, testing and commissioning of addressable remote response indicators having flashing green LED and Red LED for indication of fire and continous monitoring including necessary connection to pin point location of fire complete all as specified and directed.
Supply, install, testing and commissioning of conventional electronic speaker cum hooter with range of 25-30 meter with output not less than 4 watt including necessary connection complete all as specified and directed.
Supply and fixing of analogue addressable short-circuit Isolator module, operating voltage 15 to 30 Vdc, LPCB approved Make of Honeywell cat part No : MI-DISO or equivalent in Edwards/Siemens/Ravel/Hochiki/Advance.
S&F sub main wiring with two single core PVC-FRLSH insulated unsheathed multistranded copper conductor cable of size 1.5 sqmm drawn in and including heavy duty PVC conduit of 20mm dia medium grade, ISI marked in concealed position inclusive all fitting such as tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, saddles, pipe hooks etc fixed properly on as in concealed position incl cutting chasing & making good to disturbed surfaces & matching with the existing colour of wall/floor etc including one single core 1.5 Sqmm PVC-FRLSH insulated unsheathed multi stranded copper conductor as a continuous earth wire in conduit complete all as specified and directed. (Note: Three run of single core cable of respective size and one run of PVC conduit shall be measured and paid as one unit length).
S&F sub main wiring with two single core PVC-FRLSH insulated unsheathed multistranded copper conductor cable of size 4.0 sqmm drawn in and including heavy duty PVC conduit of 20mm dia medium grade, ISI marked in concealed position inclusive all fitting such as tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, saddles, pipe hooks etc fixed properly on as in concealed position incl cutting chasing & making good to disturbed surfaces & matching with the existing colour of wall/floor etc including one single core 4.0 Sqmm PVC-FRLSH insulated unsheathed multi stranded copper conductor as a continuous earth wire in conduit complete all as specified and directed. (Note: Three run of single core cable of respective size and one run of PVC conduit shall be measured and paid as one unit length).
Supply, install, testing and commissioning of active repeater panel for remote monitoring with 1 x 40 character liquid crystal display with backlight illumination, operating voltage 18-32 Vdc, rated voltage 24 Vdc, Alarm current 120 mA, Ambient temperature 5 to 45 deg celsius, dimension 165 x 253.5 x 50 mm and weight should not exceed 1.7 Kg all as directed by Engr-in-Charge.Make : Honeywell or equivalent in Edwards/Siemens/Ravel/Hochiki/Advance.
Supply, Installation, testing and commissioning of Network card for integration of 2 loop Panels into a networked system one network as required for two panel. Make Honeywell cat Part No 795-099 or equivalent in Edwards/Siemens/Ravel/Hochiki/Advance.
Supply, laying, jointing, testing & commissioning in trenches/ fixing with clamp on wall connecting, thembling, glanding of XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (Heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 Sqmm 4 core (earthed) complete all as specified and directed.
Excavation in trenches in hard/dense soil not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide for laying of cables, foundation, etc or for shaft well, cesspits, manholes, pireholes, etc not exc 10 Sqm plan and getting out in hard/dense soil complete all as specified and directed at site.
Returning, filling in including spreading, levelling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each, back in trenches after cables have been laid and tested,poles, stays, struts have been erected and tested all as specified and directed at site.
Removing excavated surplus soil (Soft/Hard soil) obtained from excavation to a distance not exceeding 50 mtr and deposting where directed at a level not exceeding 1.5 m above the starting point all as specifed and ddirected
M&L for sand cushioning(dry sand) to underground cable for cable protection with layer of 8cm deep before laying the cable and 15 cm depthh after laying the cable,complete all as specified and directed. Note: Punned thickness of sand layers shall be measured and paid.
M&L for laying of old size sub class B well burnt Brick laid dry flat in trenches over the cable for protection complete all as specified and directed.
M&L for boring of holes under road/drain/PCC path by manual method for inserting upto 150 mm dia light GI tubing for cable protection in minimum 60 mm depth from normal ground level all as specified and directed.Note:-GI pipe shall be measured and paid separately.Quoted rate shall be deemed inclusive of the cost of material and labour required for making good as per existing surface.
Supply and laying 40 mm dia GI tubing medium grade complete with all fittings (ISI Marked) lain in trenches/fixed complete to wall and ceiling or laid in floors, trenches, under road crossing, fixed on poles/walls for cable protection all as specified.
GUJRAL BUILDERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .