Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹20.9 L+₹2.5 L (13.7%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹21.1 L+₹2.6 L (14.3%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹21.5 L+₹3.1 L (16.7%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹21.9 L+₹3.5 L (18.7%)Rejected-AOC LOHIA NAGAR WARD NO 14 CHANDAULI UP 232104 | CHANDAULI | CHANDAULI | UP | 232104 | L5 | Rejected-AOC L5 |
Tender Value
₹20.9 L
EMD Value
₹41,700
Closing Date
29 Oct 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Yelahanka
GE (AF) Yelahanka Bangalore - 63
PROVISION OF POL STORE, LADIES TOILET AND CERTAIN MINOR WORKS AT AFS YELAHANKA
2024_MES_669191_2
8287/E8
Open Tender
Civil Works
Item Rate
180 days
Yelahanka
As per NIT
9 documents required · 9 mandatory
₹500
GE (AF) Yelahanka
₹41,700
Yes
10 Dec 2024
15 Oct 2024
31 Oct 2024
15 Oct 2024
29 Oct 2024
15 Oct 2024
Amount
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep in soft/loose soil and getting out complete all as specified and as directed.
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for laying pipes etc or for manhole shaft n exc 10 sqm on plan and n exc 1.5m in depth and getting out in soft/loose soil all as directed
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth out in hard/dense soil for laying of cables, pipes/valves, foundation for poles etc complete all as specified and directed
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. Note : For payment purpose consolidated thickness will be considered and measured.
M & L plain cement concrete 1:4:8 type D – 2 (using 40 mm graded stone aggregate) in foundation, filling and mass concrete complete all as specified and directed.
M&L for reinforced cement concrete M-25 (Design Mix) in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified and directed
M&L for reinforced cement concrete M-25 (Design Mix) in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed
M&L for reinforced cement concrete M-25 (Design Mix) in Columns, pillars, piers, posts and struts complete all as specified and directed
M&L for reinforced cement concrete M-25 (Design Mix) in Chajjas complete all as specified and directed
M&L for reinforced cement concrete M-25 (Design Mix) in slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed
M&L for use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter to flat complete all as specified and directed
M&L for use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams etc complete all as specified and directed
M&L for use and waste of formwork to sides of pillars, posts, struts, piers, columns and stachions complete all as specified and directed
M&L for use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings, wall and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed
S&F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking bending spirallv for hopping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia complete all as specified and directed
All as per item No 15 above but TMT bars of dia 6 mm to 8 mm dia as in stirrups, spacers and binders complete all as specified and directed by Engr-in-Charge.
M&L for pre-cast cement concrete block type C1 1:3:6 (using 20mm graded stone aggregate) and masonry with solid blocks, exc. 10 cm in width and setting in cement mortar 1:6 complete all as specified and directed.
M&L for cement plastering 10mm thick in cement mortar 1:6 on brick work or cement concrete surfaces and surface finished even and smooth without using extra cement complete all as specified and directed.
M&L for cement plastering 15mm thick in two layers (10mm and 5mm respectively) in cement mortar 1:4 including mixing of liquid water proofing compound as per manufacturer's instructions on brick work or concrete surfaces or in chajjas/parapet walls etc finished even and smooth without using extra cement complete all as specified and directed. Note: WPC will be measured and paid separately.
M&L for cement plastering 5mm thick in cement mortar 1:3 on brick work or concrete surfaces and surface finished even and smooth without using extra cement complete all as specified and directed.
Supply only integral liquid water proofing compound all as specified and directed.
M&L for preparation of newly plastered or un plastered surfaces of walls and applying two coats of acrylic distemper over a coat of primer complete all as specified and as directed.
M&L for applying 02 coats of cement base paint to external walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc surfaces over & including preparation of new plaster surface and a coat of primer complete all as specified and directed.
M&L for preparation of new surface and applying 03 coats of white wash on ceiling surface complete all as specified and directed.
M&L for plain cement concrete 1:5:10 type E-2 (using 40mm graded stone aggregate) as in sub base complete all as specified and as directed.
M&L for 100mm thick plain cement concrete type D-2, 1:4:8 (using 40mm graded stone aggregate) as in sub-floors, sub bases, floors and pavings etc complete all as specified and directed.
M&L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab with and including rubbing, polishing and 20mm thick screed bed in CM 1:4 complete all as specified and as directed.
M&L for machine cut kota stone slab flooring 20-25mm thick as in riser with and including 10mm thick backcoat in CM 1:3 complete all as specified and as directed.
S&F 1mm thick Steel rolling shutters, without ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type complete all specified and directed.
S&F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and as directed
M&L for preparation of new steel surface of any description, over 10 cm in width or grith and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chorme primer complete all as specified and as directed.
M&L 75 mm thick plain cement concrete type C2, 1:3:6 (using 40 mm graded stone aggregate) in sub base of flooring/hard standing and plinth protection complete all as specified and directed.
M&L for water proofing treatment shall be comprising of the following applications: - (a) 10mm thick cement plaster (1:3) using coarse sand mixed with acrylic based water proofing compound shall be provided while the concrete of roof slab is green and finishing surface even and smooth with steel trowel. (b) The surface shall be painted with one coat of cold applied bituminous primer @ 0.40 litre per sq. m, all as described in paras 11.44.5 of MES Schedule Part-I. (c) A layer of Atactic polypropylene polymer (APP) modified prefabricated membrane shall be applied over primed surfaces all as described in paras 11.44.5 of MES Schedule Part-I. (d) Benching (gola) at junctions of roof / terrace with parapets / side walls in concave shape of 80 mm radius with PCC (1:2:4), Type B-0, shall be laid. (e) Treatment mentioned in above para (a), (b) & (c) shall also be provided over side of walls/parapets upto a height of 150 mm above roof slab. (f) APP modified polymeric membrane shall be covered with bituminous based aluminum paint @ 0.2 Kg per sqm in two coats. Note : The rate quoted by the contractor deemed to be inclusive of all above provisions.
M&L for non-skid ceramic colouredtiles 7-8mm thick (square/rectangular) polished, area of each tiles exceeding 0.18 sqm but not exceeding 0.36 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10 mm thick screed bed in cement mortar (1:4) with and over 50mm thick PCC 1:2:4 type B2 (using 40 mm graded stone aggregate) and pointed in white cement with pigment to match the colour of tiles complete all as specified and directed.
M&L for glazed ceramic colour tiles of size 200x300x7mm/ 350x250x7mm/ 450x300x7mm as in walls, set and jointed in neat cement slurry over and including 10mm thick backing coat in cement mortar (1:3) and pointed in coloured cement to match for work on vertical surface such as skirting dado etc complete all as specified & as directed by Engr-in-Charge.
M&L for glazed ceramic colour tiles, size 600x1200x8-9mm thick as in walls, set and jointed in neat cement slurry over and including 15mm thick backing coat in cement mortar (1:3) and pointed in coloured cement to match for work on vertical surface such as skirting dado etc complete all as specified & as directed by Engr-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm any kind of soil all as directed.
Returning filling in excavated soil upto a depth of 30 cm after riddling of excavated soil (in lieu of sand) for cushioning of cable and refilling of trenches with left over normal excavated soil including spreading, levelling, watering and well ramming in layers complete all as specified and as directed by Engr-in-Charge.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point all as directed.
S&F PVC (SWR)110mm bore pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F PVC (SWR)110mm bore bends of any radius complete all as specified and directed.
S&F 15mm dia Stop valves, chromium plated fancy type screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F 15mm dia of Gun-metal globe or gate valve, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F Pillar taps suitable for 15mm dia bore pipe, fancy type cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered "Hot" or "Cold" with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed.
S&F 15 mm dia bib taps (fancy type), cast copper alloy with crutch or butter fly handle screwed down, screwed for iron pipe or for brass ferrule complete with check nut 15mm bore complete all as specified and directed.
S&F Wash basins, Vitreous China (flat back or angle back type) of size 630 x 450mm, including brackets, waste fittings etc complete all as specified and as directed.
S&F Vitreous China Wash down water closet pan (Pedestal pattern), white including seat cover, 'P' trap and fixing bolt etc (excluding flushing cistern and flush pipe) complete all as specified and directed.
S&F vitreous China squatting pan 'orrisa' pattern white colour of size 580x440mm with integral foot rests including provision of cement concrete complete all as specified and directed
S&F PVC valveless, syphonic action type, low level PVC flushing cistern 10 ltr capacity white with flush pipe & all fitting complete all as specified and directed.
S&F 15mm dia PVC connection pipe with PTMT Nut of length 600mm etc complete all as specified and directed.
S&F 500 ltrs capacity rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) hoisted and jointed in position all as specified in SSR Part-I including all necessary fittings for connecting with pipe line, complete all as specified and directed
S&F GI tubing 15 mm dia bore medium grade galvanised with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F PVC (SWR) S trap 110mm bore, all as specified and directed.
S&F Grating doom 100mm dia of PTMT (Minimum weight 25gms) complete all as specified and directed.
S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other Frames/Chowkhat of size 60 x 30 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
S&F Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)
S&F mild steel Butt hinges medium weight cold rolled 75mm long complete all as specified and directed.
S&F aluminium anodized barrel tower bolt of extruded section 150 mm length complete all as specified and directed.
S&F extruded aluminium alloy handles fabricated type 150 mm size, anodized complete all as specified and directed.
S&F plain sheet glass 4mm thick, ordinary quality and glazing with oil putty n.exc 0.50 Sqm in each pane complete all as specified and directed.
S&F plain sheet glass 5.5mm thick, ordinary quality and glazing with oil putty n.exc 0.50 Sqm in each pane complete all as specified and directed.
M&L for Hard core of gauge n exc 63mm in broken stone or boulders , deposited, spread and levelled in layers n exc 15 cm thick , watered and rammed to a true surface complete all as specified and directed
M&L for machine pressed precast cement concrete interlocking paver block any shape and size conforming to IS 15658-2006 of 60mm thickness, M-35 Grade with grey cement and pigment complete all as specified and directed.
M&L for Plain Cement Concrete 1:3:6 type C2 (using 40 mm graded stone aggregate) for concrete bed to 200mm dia pipe incl packing under and haunching against the sides of pipe after they are laid and tested complete all specified and directed.
M&L for 200mm internal dia RCC NP3 class pipe laid in trenches jointed with CM 1:1 and tested complete all as specified and directed.
M&L for providing plain cement concrete type B0 1:2:4 (using 12.5mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed
M&L for plain cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) in forming channel, benching inside manholes (1/2 or 3/4 section) in manholes and as in coping including necessary form work complete all as specified and directed.
M&L for Plain Cement Concrete (1:2:4), type B1 (using 20mm graded stone aggregate) as in foundation , bands benching etc including finishing the concrete surfaces even and smooth without using extra cement including necessary form work Complete all as specified and directed by Engr-in-Charge.
M&L for rendering 15 mm thick in cement mortar 1:4 fair or unfair faces of brick work or concrete surfaces, trowelled to even and fair finish including mixing with water proofing compound as per manufacturers insturction complete all as specified. Note:Water proofing compound shall be measured seperately.
Material and labour for rendering 15mm thick in CM 1:6 external fair faces of brick work or concrete surface finished even and fair without using extra cement complete all as specified and directed.
Extra for forming fair finished channel or drain of 30 cm inner girth in cement concrete using extra cement including forms, moulds mitred stopped ends etc complete all as specified and directed.
Material and labour for Precast reinforced cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) as in cover slab for manholes set in CM 1:4 including necessary form work complete all specified and directed.
Demolition of concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as directed.
Taking down plaster in wall built in cement mortar complete all as specified and directed.
Taking down chowkat or frame without taking off shutters but not exceeding 1.5 sqm each complete all as directed.
Taking down chowkat or frame without taking off shutters exceeding 1.5 sqm but not exceeding 4 sqm each complete all as directed.
M&L for applying 02 coats of interior emulsion paint (light shade) @ 10 Sqm./litre/2 coats by using roller/brush to wall surfaces over & including a coat of interior wall primer @ 10 Sqm./Litre/1 Coat as recommended for under coat by manufacturer of interior emulsion over 1.5mm thick wall care putty complete all as specified and directed.
M&L for reinforced cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in slabs supported on walls,beams and columns in floors,roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
Point wiring complete with1.5 sqmm single core PVC insulated heavy duty ISI Marked FR, unsheathed FRLS cable 1100 volts grade with multistranded copper conductor(FRLS) drawn through ERW conduit with all accessories fixed to the surface of walls/roof/ floors / ceiling etc., M S terminal boxes 60 mm deep concealed in walls covered with plastic laminated top cover sheet 3.0 mm thick fixed with cadmium plated iron screws etc including 1.5 sqmm PVC insulated, unsheathed copper conductor Muistandere FRLS cable 1100V grade as earth continuity conductor & connecting to common earth dolly for one light/Exhaust Fan point controlled by one switch.
All as per item Srl Item No 81 but for one 5 Amps socket on independent including 1.5 Sqmm earth continuty FRLS Copper Cable complete all as specified..
Point wiring completed with 1.5 sqmm single core PVC insulated heavy duty ISI Marked unsheathed FRLS copper conductor cable 1100 volts grade with multistranded copper conductor drawn through concealed stove enamelled steel conduit and including provision of PVC Insulated heavy duty ISI marked Unsheathed copper conductor,1.5 sqmm for earth continuity conductor and connected to common earth dolly, including suitable size of sheet metal box 1.6mm thick fixed and flushed inside the walls, with 3mm thick laminated sheet top cover for housing the flame proof switches, switches, flame proof socket outlets, flame proof fan regulators etc., for One light/exhaust fan point controlled by one 5 Amps switch complete all as specified and directed.
S&F socket outlet 3 pin 6 Amps flush type complete all as specified and directed.
S&F switch piano flush type, single pole, one way 6 Amps complete all as specified and directed.
S&F ceiling rose, three terminal, PVC/polycarbonate, isolated body, ISI marked complete all as specified and directed by Engr-in-Charge.
S&F in repair modular white cover plate with frame, 1 module ISI marked complete all as specified and directed Engr-in-charge
S&F exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as specified and directed by Engr-in-Charge.
S&F LED light fitting mirror type with high output diffuser 2 feet, 10-watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engr in charge.
S&F in repair LED building security light fitting 35-Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection all as specified and directed.
S&F sheet metal enclosures for MCB distribution board 240 Volts Single pole and neutral 4 way Single door with 200 amps rated bus bar complete including flushing the DBs inside the wall and making good to the disturbed surfaces and also matching with the existing surface all as specified and directed by Engr in charge.
S&F MCB SPN 32 Amps, 240 Volts, 'C' Curve, 10 KA rupturing capacity complete all as specified and directed.
S&F MCB SP 6 to 32 Amps, 240 Volts, 'C' Curve, 10 KA rupturing capacity complete all as specified and directed.
M & L for Earthing complete with galvanised earth plate electrode of size 600x600x6 mm thick buried directly in ground earth pit not less than 2.25 m below ground level with top edge of earth plate not less than 1.5 mtrs below ground level connected to 4 mm dia GI earth wire as earth lead upto a length of 7.5 metre long by means of bolts, nuts, washers etc. and protected by GI pipe light grade 15mm dia and 20mm dia GI tubing light grade with funnel for watering, all as shown in electrical plate No 3 of SSR Part-I, back-fill with salt and charcoal, provision of test point including connected to earth test point and necessary earth work excavation in any type of soil, PCC (1:3:6) type C1 as foundation bed and chamber made up of RCC (1:2:4) type B1, iron grill including GI cover with hinge and funnel watering pipe etc complete all as specified and directed Note : If desired testing result is not acheived re-earthing shall be carried out by the contractor at no cost to the department.
S&F LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 66 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and as directed.
S & F flame proof exhaust fan 305 mm (12)" sweep heavy duty 1440 RPM, single phase 240 volts AC 50 Hz and connecting up complete including louvers, bird mesh complete all as specified and directed.
S&F Switch Flame proof Rotary type with termination box in LM, 16 Amps Double Pole 250 Volts complete all as specified and as directed.
Supply & Fix Air termination single pointed, copper rod 12mm dia 300 mm long complete all as specified and as directed
M&L for Earthing complete with copper earth plate electrode 60 cm x 60 cm x 3.15 mm thick, buried directly in ground (earth pit not less than 2.25 Metre, deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to 20 x 3 mm copper earth strip by means of bolts, nuts, washers, check nuts of galvanised iron or steel all as specified or indicated including excavation and earth work PCC 1:2:4 type B-1(using 20 mm graded aggregate) in chamber with MS chequered plate 6 mm thick as a chamber cover of the earth pit and writing the value of the earthing after completion including GI funnel, wire mesh and 25 mm bore GI pipe light grade for watering and connected to earth test point complete all as specified and as directed. Note:- Earthing Value should be below 01 Ohm. If desired testing result is not acheived re-earthing shall be carried out by the contractor at no cost to the department.
M&L copper strip earth continuity conductor or main earthing lead of size 32 mm x 6 mm fixed on wall/ floor/roof or any other surface with porcelain insulators and all joints should be by means brazing and all as specified and as directed.
S&F Test Point Terminal block made of gun metal or phosphorus bronze of size 75x75x25mm drilled and screwed including 3 nos 8mm dia 25mm long hexagonal head screw complete all as specified and directed by Engineer-in-charge. .
M&L for cutting existing 50mm bore water mains and inserting Tee 50 mm x 25mm for taking branch connection including fittings and joints complete all as specified and directed
S&F Gate valve, 25mm dia, cast iron body with flanged ends duly drilled ISI marked as per IS-14846:2000, PN-1.6 with brass spindle and check nut including operating wheel etc and fixed with flanges both end and new bolt, nuts, washers and rubber insertion packing complete all as specified and directed
S&F Brass Ball Valve of 25mm dia conforming to relevant IS to fit inside the storage tank complete all as specified and directed
Supply and lay 25 mm dia GI pipe “Medium grade” with all fittings, laid in trenches complete all as specified and directed
Supplying and laying brick protection cover on cable with sub class 'B' brick, laid dry and flat adjacent to each other complete all as specified and directed
Supply, laying and testing 4 core, 6 Sqm XLPE Insulated cable, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size complete all as specified and as directed by Engr-in-Charge.
S&F MCB SPN, 10KA 'C' curve 40 Amps current carrying capacity, 240V, in the existing panel with connection, testing and commissioning complete all as specified and as directed
S&F modular flush metal box 1/2 module ISI marked complete all as specified and as directed
M&L for cutting holes in brick / stone wall for inserting holdfast and making good disturbed portion in cement mortor 1:3 or cement concrete 1:2:4 type B-1 as required for exhaust fan complete all as specified and directed
M&L for sub-main wiring with two runs of 2.5 sqmm unsheathed PVC insulated, single core cable with copper stranded conductor FR drawn through and including suitable dia metallic steel conduit and conduit accessories concealed/fixed to wall/roof/floor and including suitable steel conduit with 2.5 sqmm FR copper earth wire and all as specified and directed by Engr-in-charge. Note: 2 runs of cable and one run earth wire and steel conduit will be measured as one length. Three run of 2.5 Sq mm cable and steel conduit is measured as one Run or one Meter.
Sub main wiring complete with two runs of 6 Sqmm single core PVC insulated heavy duty ISI Marked, FRLS unsheathed cable 1100 volts grade, multistanded with copper conductor drawn through and including 20 mm dia metallic steel conduit and conduit accessories concealed /fixed to walls/roofs/floors etc, and including provision of PVC insulated heavy duty ISI Marked, unsheathed cable 1100 volts grade 4 Sqmm for earth continuity conductor and making good the disturbed surface also matching the existing surface complete all as specified and as directed by Engineer-in-charge. Note:- Two run of cable and one run of earth wire and PVC conduct is measured as one length.
D K Engineers and contractors (BID ID -3146972)
SRI AYYAPPA ENTERPRISES (BID ID -3152725)
B.S.S.ENTERPRISES (BID ID -3153385)
RKT ENGINEER & SONS (BID ID -3152489)
ANAND REFRIGERATION (BID ID -3152775)
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .