Loading…
Loading…
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
23 Jul 2026, 6:00 pm
GE NAGROTA
GE NAGROTA
SPL REPAIR/REPLACEMENT OF PERIMETER SECURITY LIGHTS OF VARIOUS SECTORS AND CONNECTED ITEMS UNDER GE NAGROTA
2026_MES_774730_1
CANO GEN/TOKEN-70/2026-2027
Open Tender
Electrical and Maintenance Works
180 days
GE NAGROTA
Class D Category b(i)
8 documents required · 8 mandatory
₹500
GE NAGROTA
₹92,000
Yes
2 Jul 2026
2 Jul 2026
28 Jul 2026
2 Jul 2026
23 Jul 2026
16 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | S&F in repair LED street light fitting of capacity 45W of epoxy powder coated pressure die cast aluminium housing with toughened glass with Lens delivering (efficiency) : 120 lumens/ watt, and high performance driver with built in surge , over voltage, open/short circuit protection for longer life, IP-66 protection, 50000 burning hours including making connection with two core PVC insulated and sheathed copper conductor cable of size 1.50 sqmm from fitting to light source complete all as specified and directed.
Note for item No. 1 to 8 :- 1. Contractor shall be submitted the warranty cert from the manufacturer for 02 years before payment and contractor is responsible for to repair/replacement the unserviceable fitting on free of cost from the manufacturer for the period of 02 years from payment date.
2. 02 years warranty certificate from the manufacturer , purchase voucher and LM-79 & LM-80 certificate before payment. | 175 | Each | - | - |
| 2 | S&F in repair LED street light fitting of capacity 60W of epoxy powder coated pressure die cast aluminium housing with toughened glass with Lens delivering (efficiency) : 120 lumens/ watt and high performance driver with built in surge , over voltage, open/short circuit protection for longer life, IP-66 protection, 50000 burning hours including making connection with two core PVC insulated and sheathed copper conductor cable of size 1.50 sqmm from fitting to light source complete all as specified and directed. | 425 | Each | - | - |
| 3 | S&F in repair LED street light fitting of capacity 72W of epoxy powder coated pressure die cast aluminium housing with toughened glass, Lens delivering (efficiency) : 120 lumens/ watt and high performance driver with built in surge , over voltage, open/short circuit protection for longer life, IP-66 protection, 50000 burning hours including making connection with two core PVC insulated and sheathed copper conductor cable of size 1.50 sqmm from fitting to light source complete all as specified and directed. | 425 | Each | - | - |
| 4 | S&F in repair LED street light fitting of capacity 90W of epoxy powder coated pressure die cast aluminium housing with toughened glass, Lens delivering (efficiency) : 120 lumens/ watt and high performance driver with built in surge , over voltage, open/short circuit protection for longer life, IP-66 protection, 50000 burning hours including making connection with two core PVC insulated and sheathed copper conductor cable of size 1.50 sqmm from fitting to light source complete all as specified and directed. | 190 | Each | - | - |
| 5 | S&F in repair of LED flood light capacity 100W of epoxy powder coated pressure die cast aluminium housing with toughened glass, Lens delivering (efficiency) : 120 lumens/ watt and high performance driver with built in surge , over voltage, open/short circuit protection for longer life, IP-66 protection, 50000 burning hours including making connection with two core PVC insulated and sheathed copper conductor cable of size 1.50 sqmm from fitting to light sourcecomplete all as specified and directed. | 75 | Each | - | - |
| 6 | S&F in repair of LED flood light capacity 120W of epoxy powder coated pressure die cast aluminium housing with toughened glass, Lens delivering (efficiency) : 120 lumens/ watt and high performance driver with built in surge , over voltage, open/short circuit protection for longer life, IP-66 protection, 50000 burning hours including making connection with two core PVC insulated and sheathed copper conductor cable of size 1.50 sqmm from fitting to light source complete all as specified and directed. | 75 | Each | - | - |
| 7 | S&F in repair of LED flood light capacity 150W of epoxy powder coated pressure die cast aluminium housing with toughened glass, Lens delivering (efficiency) : 120 lumens/ watt and high performance driver with built in surge , over voltage, open/short circuit protection for longer life, IP-66 protection, 50000 burning hours including making connection with two core PVC insulated and sheathed copper conductor cable of size 1.50 sqmm from fitting to light source complete all as specified and directed. | 75 | Each | - | - |
| 8 | S&F in repair of LED flood light capacity 180/200W of epoxy powder coated pressure die cast aluminium housing with toughened glass, Lens delivering (efficiency) : 120 lumens/ watt and high performance driver with built in surge , over voltage, open/short circuit protection for longer life, IP-66 protection, 50000 burning hours including making connection with two core PVC insulated and sheathed copper conductor cable of size 1.50 sqmm from fitting to light source complete all as specified and directed. | 50 | Each | - | - |
| 9 | S&F in repair Junction box made of SMC/FRP sheet ready made of size 300 mm x 200 x 105 mm having 100 A Capacity RYB and neutral aluminium bus bar of 3 mm thick duly fitted on suitable insulator, and MCB SP 6 A 10 KA 240V -01 No. with fixing arrangement fixed properly to pole/fixed on wall with MS Clamps 25x5 mm and nut and bolts complete all as specified and directed. | 10 | Each | - | - |
| 10 | Supply and fixing in replacement of automatic street light switch using Nature Switch for automatic switching of street light based on LUX level of nature light having ON ≤ 30 lux and OFF ≥ 10 Lux . The sensor (Nature Switch) along with suitable power contactor , MCB and support termianl should be enclosure made of rust proof, electric shock proof , termite proof and FRLS grade SMC junction box(sintex make) conforming to confirmining IS 13947.4-1 & IS 8828, IP 66 including contactors ( 3 Nos each) and incoming- ourgoing MCBs ( 3 Nos each) rating of 25-40 amp and Circuit copper wiring of min 10 Sqmm cable incl taking down old unsv complete all as specified and directed. | 5 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
Tender70.pdf
Tender Documents • 1.03 MB
BOQ_868850.xls
BOQ • 2.11 MB
Download all tender documents and submit your bid