Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.0 LAccepted-AOC VILLAGE BADITTER P O JOURE AMB TEHSIL BADSAR DISTT HAMIRPUR H P | HAMIRPUR | HIMACHAL PRADESH | 174304 | L1 | Accepted-AOC L1 | |
| 2 | L2₹44.3 L+₹6.3 L (16.6%)Accepted-AOC | L2 | Accepted-AOC L2 |
Tender Value
₹45.3 L
EMD Value
₹75,480
Closing Date
25 Sept 2021, 11:00 amClosed
EE JSV Division Barsar
EE JSV Division Barsar
SH C O Percolation well, clear water Sump well 90000 liters at head works and MBR 90000 liters pump house at head works
2021_HPIPH_52488_1
EE-JSV-BSR-TA-22-11656-11700
Open Tender
Civil Works
Item Rate
180 days
JSV Sub Division Barsar
Please refer Tender documents.
8 documents required · 8 mandatory
₹800
Yes
EE JSV Division Barsar
₹75,480
Yes
9 Dec 2021
18 Sept 2021
25 Sept 2021
18 Sept 2021
25 Sept 2021
18 Sept 2021
18 Sept 2021 - 25 Sept 2021
Amount
Excavation in foundation , trenches etc., in all kinds of soil such as pickwork, jumper work blasting work, in soft / hard rock, including chiseling wedging out of rocks clearance of bushes etc.including shoring, dewatering etc. in all leads and lifts stacking the excavated soil upto any lead and lift clear from the edge of excavation and then returning the stacked soil in 15cm layers when required into plinth , sides of foundation etc. consolidating each deposited layers by ramming and watering and then disposing of all surplus earth within all leads and lifts complete to the entire satisfaction as directed by the Engineer-in-charge of the site of work.
Earth work in foundation for digging well in dry excavation from gravel level upto the level where well curb is placed, including disposing of soil within all radius and filling space outside the well after completion from N.S. level to 1.5 meters depth in all kind of soil such as pick work,jumper work, blasting work Soft/hard Rock chiseling workSoft/hard Rock(where blasting is prohibited) complete in all respect as per direction and to the entire satisfaction of the Engineer-in-charge.
Wet well sinking in gravel including all pumping, shoring etc.complete in all respect.
From spring level to 3.00 meters below spring level in all leads and lifts.
Exceeding 3 meters, but upto 6.00 meters belowspring level in all leads and lifts.
Steel work welded in built up sections, trusses and framed work, including cutting, hoisting fixing in position and applying a priming coat of red lead paint. In beams joists channels, angles, tee, flats with connection plates or angle cleets as in main and cross beams, hip and jack rafters, purlins connected to common rafters and the like complete in all respect as per direction and to the entire satisfaction of the Engineer-in-charge.
Lowering steel well curb in the pit and assembling in position in all depth complete in all respect as per direction and to the entire satisfaction of the Engineer-in-charge.
Providing and laying cement concrete work 1:1.5:3 (1 Cement:1.5 Sand :3 graded stone aggregate 20 mm nominal size) and curing complete excluding cost of form work and reinforcement for reinforced concrete work in :
Foundations,footings bases of columns and the like and mass concrete in all leads and lifts.
Suspended floors,roofs,landing shelves and their supports balconies beams,girders bressumers and cantilever upto floor two level including carriage of material in all leads & lifts.
Columns, pillars posts and struts upto floor two level in all leads and lifts.
Providing and laying no fine concrete 1:4 (1 Cement:4 stone) aggregate 20mm nominal size) and curing complete in foundation and plinth excluding the cost of form work complete involving all leads and lifts to the entire satisfaction of Engineer-in-charge.
Providing and Laying cement concrete1:3:6 (1Cement :3Sand:6 graded stone aggregate 20 mm nominal size) including curing complete excluding the cost of form work in foundation and plinth in all leads and lifts.
Providing form work with steel plates 3.15mm thick welded with angle iron in frame 30x30x5mm, so as to give a fair finish including centring, shuttering , strutting and propping etc. with wooden battens and ballies height of propping and centering below supporting floor to ceiling not exceeding 4meters and removal of the same for insitu reinforced concrete and plain.
Foundation footing and base of column and the like and mass concrete complete in all leads and lifts..
Vertical surfaces such as walls(any thickness) partitions and the like including attached pilasters, buttresses, plinth and string courses and the like complete in all respect as per direction and to the entire satisfaction of the Engineer-in-charge.
Flat surfaces such as soffits of suspended floors, roofs, landings and the like floors etc. above 200mm. In thickness with in all leads and lifts & to the entire satisfaction of the Engineer-in-charge
Beams,cantilevers,girders & lintels, sides & soffits of beams, haunching,cantilevers,bressumers 1.00 mts. In depth in all heights from floor in all leads and lifts.
Providing from work of ordinary timber plankings so as to give a rough finish including centring,shuttering, strutting and propping etc. height of propping and centring below supporting floor to ceililng not exceeding 4 metres and removal of the same for insitu reinforced concrete.
Arches beyond 6 metres span.
Square rubble masonary coursed with hard stone of approved quality in in cement mortar 1:4( 1cement:4 sand ) in all leads and lifts.:-
Foundation footing and base of column and the like and mass concrete.
Above NSL ground level
Random rubble stone masonry/polygonal rubble masonery ( uncoursed / brought to couses) with hard stone of approved quality in foundation & plinth including leveling up with cement concrete 1:6:12 ( 1cement :6sand : 12 graded stoene aggregate 20mm nominal size ) at plinth level in cement mortar 1:6 ( 1 cement :6 sand ) in all leads & lifts
Brick work using common burnt clay building bricks (IInd class) in foundation and plinth in cement mortar 1:4 (1cement:4 sand) in all leads and lifts.
Providing and Laying cement concrete1:5:10 (1Cement :5Sand:10 graded stone aggregate 40 mm nominal size) including curing complete excluding the cost of form work in foundation and plinth in all leads and lifts.
Providing and Laying cement concrete Design mix. M-30 not leaner than 1:1.5:3 nominal size (1Cement :1.5 Sand:3graded stone aggregate 20 mm nominal size) & curing complete excluding the cost of form work and reinforcement for reinforced concrete work in :-
Foundations,footings bases of columns and the like and mass concrete in all leads and lifts.
Walls (any thickness but not less than 0.10 metre thickness) including attached pilasters buttersses ,plinth and string courses etc. from top of foundation upto floor two level in all leads and lifts.
Suspended floors,roofs,landing shelves and their supports balconies beams,girders bressumers and cantilever upto floor two level including carriage of material in all leads & lifts.
Arches upto floor two level
Brick work using common burnt clay building bricks (IInd class) in super structure above groubnd level upto floor two level in cement mortar 1:6 (1cement:6 sand) in all leads and lifts.
Half brick masonery in common burnt clay building bricks in cement mortar 1:4( 1cement :4sand) 2nd class birck complete in all leads and lifts.
Providing woodwork in frames of doors, windows, clerestory, windows and other frames wrought,framed and fixed in position with second class deodar wood in all leads and lifts.
Providing and fixing panelled glazed or panelled and glazed shutters for doors windows and clerestory windows including black enamelled iron butt hinges with necessary screws in all leads and lifts.
Providing and fixing wire gauge shutters using galvanised M.S. wire gauge of I.S. gauge designation 85 G. with wire of dia 0.56 mm for doors windows and clerestorey windows including bright finished black enamelled iron hinges with necessary screws with necessary screws 40mm thick withs 2nd class Deodar wood in all leads and lifts.
20mm cement plaster in single coat of rough sides of bricks/concrete stone walls for interior plastering upto floor two level including arrises internal rounded angles chamber and rounded angles not exceeding 80mm in girth and finished even and smooth in cement mortar 1:4(1cement:4sand) within all leads and lifts.
20mm cement plaster in single coat of rough sides of bricks/concrete stone walls for interior plastering upto floor two level including arrises internal rounded angles chamber and rounded angles not exceeding 80mm in girth and finished even and smooth in cement mortar 1:6(1cement:6sand) within all leads and lifts.
6 mm cement plaster to ceiling in CM 1:3 (1Cement :3 Sand) in all leads and lifts.
15 mm cement plaster in single coat of fair sides of bricks/concrete stone walls for interior plastering upto floor two level including arrises internal rounded angles chamber and rounded angles not exceeding 80mm in girth and finished even and smooth in cement mortar 1:6(1cement:6sand) within all leads and lifts.
Providing plinth protection 50mm thick in cement concrete 1:3:6 (1cement:3sand:6 graded stone aggregate 20mm nominal size) including finishing of the top surface of concrete smooth in all leads and lifts.
Providing in RCC work smooth finishing of the exposed surface with cement mortar 1:3 (1 cement : 3 sand) with in all leads and lifts & to the entire satisfaction of the Engineer-in-charge.
Providing tor steel reinforcement for R.C.C. work including bending, binding and placing in position complete upto floor two level including carriage of material in all leads & lifts.
Steel work welded in built up sections,trusses & framed work, including cutting ,hoisting & fixing in position & applying a priming coat of red lead paint :- In grating, framed ,guards,bars, ladders, railing, brackets & similar works in all leads and lifts..
Laying jointing and testting of GMS pipe following dia (medium/ light class) for scour pipe, inlet pipe , over flow pipe & distribution system including carriage of material in all leads & lifts.( Labour rates.)
65 mm dia .
Providing and fixing double flanged C.I sluice valve of following dia (with hand wheel) as per IS: 780 (including brass spindleand as per IS: 2906 Class-II complete with bolts., nuts, rubber insertion etc. ( along with tail pieces if required) following dia including all leads and lifts complete. ( Bir make) with M.S. flanges of table 5.
65 mm dia Class P.N. 1.0
Providing and fixing SFRC Man hole cover with frame having frame size of 560mm internal dia (Medium duty) The Weight of cover & frame should not less than 100kg including carriage ofmaterial in all leads & lifts.
Manufacturing & fixing manhole cover of size 60x60cm made of angle iron size 40x40x5mm thick covered with M.S .flate including hingeses, handles, holdfast,locking arrangemetns, lock key Standard make including priming coat with red oxide paint and fixing with cement concrete 1:1.5:3 ( 1cement :1.5sand :3graded steone aggregate 20mm nominal size ) complete in all respects.
Constructing chamber for sluice valves with C.I surface box 100mm top diameter, 160mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab1:2:4(1cement:2sand: 4 graded stone aggregate 20mm nominal size ) 100mm thick foundation concrete 1:5:10(1cement:5sand:10 graded stone aggregate 40mm nominal size ) and insideplastering with cement mortar 1:3(1cement:3sand) finished with a floating coat of neat cement including curing complete with 600x600x750mm inside size with 150mm thick wall of RCC 1:2:4 ( 1cement :2sand :4 graded stone aggregate 20mm nominal size ) complete with form work and reinforcment with 6mm bars at not exceeding 150mm centres both ways in all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Providing and fixing 200mm wide cast iron rungs with chequered or ribbed non slip surface including fixing in manholes with 200mm x200mmx100mm cement concrete 1:3:6 ( 1cement :3sand :6 graded stone aggregate 20mm nominal size and curing complete with in all leads and lifts & to the entire satisfaction of the Engineer-in-charge
Distempering two coat with dry distemper of approved brand and manufacturers of required shade of undecorated wall surfaces to give even shade over and including a priming coat with alkali-resistance primer of approved brand and manufacturer after throughly brushing the surface from motor dropping and other foreign matter and also including preparing the surface even and sand papering smooth priming coat with distemper primer in all leads and lifts.
Painting two coats(excluding priming coat) on new wood and wood based surface with ready mixed paint brushing the give and even shade including cleaning of all dirt dust and other foreign matter and sand papering and stopping with ready mixed paint other than white in all leads and lifts.
White washing with lime on undecorated walls surface (two coats) to give an even shade including thoroughly brooming the surface dirt dust mortar dirt and other foreign matter in all leads and lifts.
Finishing wall with water proofing cement paint of approved brand & manufacture & of required shade on undecorated wall surfaces (two coats) to give an even shade after thotoughly brushing the surface to remove all dirt & remains of loose powdered materials.
Providing and fixing M.S.fan clamp(Type-I of 16mm dial M.S. Bar bent to shape with hooked ends in RCC. Slab during laying including painting the exposed portion of loop all as per standard design complete in all leads and lifts.
Providing 40x3mm flat iron hold fast 40cm long including fixing to frame with 10mm dial meters bolts and nuts and wooden plug and embeding in cement mortar block 30x10x15cm 1:3:6(1cement:3sand:6 graded stone aggregate 20mm nominal size in all leads and lifts..
Providing and fixing following anodized aluminium fittings of anodized transparent and shade with necessary screw etc.complete in all leads and lifts.
Sliding door bolts 250x16mm.
tower bolts (Barrel type) leads and lifts. 200x10mm.
handles 125 mm dia
Providing and fixing M.S. grill of required pattern in wooden frames of windows etc. with M.S. flat square or rounded with round head nuts and bolts or by screwed complete in all leads and lifts.
Stone/Boulder filling dry hand packed tightly under lean concrete in all leads and lifts.
Precast terrazzo tiles hydraulic compressed 20 mm thick (with marble chips of specified sizes) in skirting and risers of steps not exceeding 30 cm in height on 10 mm thick cement plaster 1:3 (1 cement: 3 sand)jointed with neat cement slurry mixed with pigment to match the shade of tiles (wherever required)including rubbing and polishing complete with tiles of following shades in all leads and lifts.
Rakesh Kumar Sharma
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .