Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.6 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹20.9 L+₹5.0 L (31.3%)Rejected-Finance | L2 | Rejected-Finance HIGHER BIDDER |
Tender Value
Refer Docs
EMD Value
₹39,800
Closing Date
4 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SH A K SINGH SE CWE NAVY VASCO
CWE NAVY VASCO VASCO DA GAMA GOA 403802
COMPREHENSIVE MAINTENANCE OF INCINERATORS PASSENGER LIFT MECHANICAL LAUNDARY UPS FORCED VENTILATION AND CERTAIN MISCELLANEOUS WORKS AT HQ GNA INS GOMANTAK INHS JEEVANTI UNDER GE GOMANTAK VASCO
2021_MES_410356_1
85352/E8
Open Tender
Civil Works
Item Rate
334 days
CWE NAVY VASCO
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
Yes
GE GOMANTAK VASCO
₹39,800
Yes
11 Mar 2021
7 Jan 2021
6 Feb 2021
7 Jan 2021
4 Feb 2021
21 Jan 2021
60 days
Amount
Comprehensive maintenance of electrically operated 4/6 passenger lift installed at VKD,Gomantak in reliable safe and efficient operating condition by regularly examining including attending lift in case of emergency , lubricating and adjusting the equipments and carry out planned maintenance in systematic and controlled manner suitable for serving G+3 with electric power operated doors,ARD complete by Skilled Lift Mechanic all as specified and as directed. Notes: (i) The above maintenance shall include complete maintenance of existing lift by regularly and systematically examining adjusting fabricating as required for smooth and functioning of the equipment/lift. The cost of all Minor spares such as nuts bolts,cleaning accessories ,lubricant,oil etc shall be deemed to be included in the rates quoted by the contractor. (ii) Contractor shall prominently display his contact/mobile number inside and outside the lift on each lift for call in emergency. (iii) Major worn out/ defective part shall be measured and paid separately under respective item of schedule.
Supply, fixing, testing and commissioning of Door drive VVF5+(PM) (door formator) including taking out old unserviceable one complete all as specified and as directed.
Supply, fixing, commissioning and testing ARD 5HP (Automatic Rescue Device) with panel complete in all respect including necessary internal wiring work, including maintenance free ARD batteries 05 Nos suitable for 4/6 passengers capacity lift (G+3) installed at VKD,Gomantak including taking down old unserviceable one complete all as specified and as directed.
Supply, fixing & testing of 3 phase power control line choke including taking out old unserviceable one complete all as specified and as directed.
Supply, fixing & testing of speed control DBR including taking out old unserviceable one complete all as specified and as directed.
Supply, fixing & testing of Mother board card (AD009) including taking out old unserviceable one complete all as specified and as directed.
Supply, fixing & testing of 15 Relay card including taking out old unserviceable one complete all as specified and as directed.
Supply, fixing & testing of Safety card 110 V card including taking out old unserviceable one complete all as specified and as directed.
Supply, fixing & testing of SMPS -12V/3A (ADPSMEL81) including taking out old unserviceable one complete all as specified and as directed.
Supply, fixing & testing of SPP (digital Voltage protection) including taking out old unserviceable one complete all as specified and as directed.
Supply, fixing & testing of Diode Bridge Card including taking out old unserviceable one complete all as specified and as directed.
Supply, fixing & testing of Contactor 110 V (ADP18FEL017-18) including taking out old unserviceable one complete all as specified and as directed.
Supply, fixing & testing 2 relay Card including taking out old unserviceable one complete all as specified and as directed.
Supply, fixing & testing Voice announcement card including taking out old unserviceable one complete all as specified and as directed.
Supply, fixing & testing Transformer 300 VA (ADPTRFEL32) including taking out old unserviceable one complete all as specified and as directed.
Supply, fixing, testing and commissioning of Door sensor along with all connected accessories including taking down old unserviceable one complete all as specified and as directed.
Supply, fixing, testing of Landing Operating Panel (LOP) assembly along with all connected accessories including taking down old unserviceable one complete all as specified and as directed.
Supply, fixing, testing of Car inside button including taking down old unserviceable one complete all as specified and as directed.
Supply, fixing, testing of Break coil including taking down old unserviceable one complete all as specified and as directed. Note for Item Nos 2 to 19 (i) All these items to be provided for the lift mentioned at SI Item No 01 here Iin before (ii) All make shall be of OEM or OEM's recommadation
S & F Electronic Voltage stabilizer Single phase ,working range 90 VAC-290 VAC,Cap 1.3 Amp complete all as specified and as directed.
S & F UPS of Capacity 650 VA, Input voltage 140V-300V AC, Frequency 50Hz(±10%) Output voltage 230V AC Freq 50 (±1Hz),12V/7AH battery -01 No complete all as specified and as directed.
S & F recess mounted LED cabin lights 6W (round) cutout size as per site requirement complete all as specified and as directed.
Supply, fixing, testing and commissioning of VVVF drive (5/7.5HP) suitable for 4/6 passengers capacity lift (G+3) main control panel installed at VKD Gomantak including taking out old unserviceable one complete all as specified and as directed.
Comprehensive maintenance of electrically operated passenger cum bed lift with a carrying capacity of 15 passenger to serve (G+1) lift installed at Jeevanti Hospital ,Gomantak in reliable safe and efficient operating condition by regularly examining including attending lift in case of emergency , lubricating and adjusting the equipments and carry out planned maintenance in systematic and controlled manner with electric power operated doors,ARD complete by Skilled Lift Mechanic all as specified and as directed. Notes: (i) The above maintenance shall include complete maintenance of existing lift by regularly and systematically examining adjusting fabricating as required for smooth and functioning of the equipment/lift. The cost of all Minor spares such as nuts bolts,cleaning accessories ,lubricant,oil etc shall be deemed to be included in the rates quoted by the contractor. (ii) Contractor shall prominently display his contact/mobile number inside and outside the lift on each lift for call in emergency. (iii) Major worn out/ defective part shall be measured and paid seperately under respective item of schedule.
Supply, fixing, commissioning and testing ARD 15 HP (Automatic Rescue Device) with panel complete in all respect including necessary internal wiring work, including maintenance free ARD batteries 08 Nos including taking down old unserviceable one complete all as specified and as directed.
Supply, fixing Control main transformer including taking down old unserviceable one complete all as specified and as directed.
Supply, fixing DC rectifier bridge card including taking down old unserviceable one complete all as specified and as directed.
Supply, fixing 8 relay card including taking down old unserviceable one complete all as specified and as directed.
Supply, fixing 4 relay card including taking down old unserviceable one complete all as specified and as directed.
Supply, fixing mother board G+7 auto door including taking down old unserviceable one complete all as specified and as directed.
Supply, fixing single phase preventer including taking down old unserviceable one complete all as specified and as directed.
Supply, fixing 12 SMPS card including taking down old unserviceable one complete all as specified and as directed.
Supply, fixing door sensor including taking down old unserviceable one complete all as specified and as directed.
Supply, fixing 12 V relay + base including taking down old unserviceable one complete all as specified and as directed.
Supply, fixing LOP walk mounting including taking down old unserviceable one complete all as specified and as directed.
Supply, fixing, testing and commissioning of VVVF drive (10HP) including taking down old unserviceable one complete all as specified and as directed. Note for Item Nos 25 to 36 (i) All these items to be provided for the passenger cum bed lift mentioned at SI Item No 24 here Iin before (ii) All make shall be of OEM or OEM's recommadation
S & F recess mounted LED cabin lights 8W (round) cutout size as per site requirement complete all as specified and as directed.
M&L for complete servicing of Solar Water Heater thermosyphonic type of capacity 1250 ltrs including cleaning of main tank, Solar power module/ Solar Panel Reflectors including checking & repairing leakage of inlet/ outlet pipes of Solar Water Heater complete installed at INHS Jeevanti all as specified and as directed.
Supply and fixing heating element 3 KW for the purpose of backup heater suitable for existing solar water heating system complete all as specified and as directed .
Supply and fixing only thermostat for heating element 3 KW for the purpose of backup heater suitable for existing solar water heating system complete all as all as specified and as directed .
M&L for complete servicing of Solar Water Heater thermosyphonic type of capacity 100 LPD including cleaning of main tank, Solar power module/ Solar Panel Reflectors including checking & repairing leakage of inlet/ outlet pipes of Solar Water Heater complete installed at MNS Block,Gomantak all as specified and as directed.
M & L for cleaning of SS hood of forced ventilation (chimney inside) system 22 Guage of size 14 x 4 feet by hot water, detergent and SS polish at ships galley , DSC galley & 2 W det Ship Galley complete all as specified and as directed.
M & L for servicing and cleaning of fresh air ducting including fresh air outlet grills of forced ventilation system of size 1.5 x 1.5 ft after dismantling nuts and bolts by using hot water, detergent and SS polish and refixing the same in original position with new nuts/bolts and washers at ships galley , DSC galle & 2 W DET Ship Galley complete all as specified and as directed.
M & L for servicing and cleaning of exhaust ducting of forced ventilation system after dismantling nuts and bolts by using hot water, detergent and SS polish and refixing the same in original position with new nuts/bolts and washers at ships galley ,DSC galley & 2 W DET Ship Galley complete all as specified and as directed.
Taking down & disconnecting electrical connections for cleaning of exhaust 3 HP centrifugal blower 1440 RPM with cleaning solution /warm water and detergent/Pressure air including blower balancing and painting with synthetic enamel paint of existing colour by spraying, including filling cavities with filler, one coat after cleaning dust at ships galley (02 Nos) ,DSC galley (01 Nos) & 2 W DET Ship Galley (01 No) all as specified and as directed.
M &L for cleaning of fresh air blower fan and painting with synthetic enamel paint of existing colour by spraying, including filling cavities with filler including replacement of micro filter of 20/90 microns (as per existing filter) of existing make and model at ships galley ,DSC galley & 2 W DET Ship Galley complete all as specified and as directed.
M & L for cleaning of Stainless steel exhaust hood plastic coated made by 1mm thickness (inland type ) size 13x 5.5x2ft- 01 No by hot water, detergent and SS polish at GNA Officers Mess complete all as specified and as directed.
M & L for cleaning of Stainless steel exhaust hood plastic coated made by 1mm thickness (inland type ) size 10x5.5x2 ft-01 No by hot water, detergent and SS polish at GNA Officers Mess complete all as specified and as directed.
M & L for servicing and cleaning of fresh air ducting including fresh air outlet grills of forced ventilation system of size 380 sqft after dismantling nuts and bolts by using hot water, detergent and SS polish and refixing the same in original position with new nuts/bolts and washers at GNA Officers Mess complete all as specified and as directed.
M & L for servicing and cleaning of stainless steel ducting made of 22 swg SS angle frame with SS bolts and nut 25 X 3 mm thickness (To exhaust system ) - 630 sq ft after dismantling nuts and bolts by using hot water, detergent and SS polish and refixing the same in original position with new nuts/bolts and washers at GNA Officers Mess complete all as specified and as directed.
Cleaning of (a) 2 HP centrifugal blower made by stainless steel with Kriloskar or LHP make motor 1440 RPM 3 phase (To exhaust system) - 01 No (b) 2 HP centrifugal blower made by stainless steel with Kriloskar or LHP make motor 1440 RPM 3 phase (To fresh air system) - 01 No (c) 7.5 HP centrifugal blower made by stainless steel with Kriloskar or LHP make motor 1440 RPM 3 phase (To exhaust system) - 01 No with warm water and detergent including blower balancing and painting with painting with synthetic enamel paint of existing colour by spraying, including filling cavities with filler, one coat after cleaning dust at GNA Officers Mess all as specified and as directed.
M &L for cleaning of fresh air blower fan and painting with synthetic enamel paint of existing colour by spraying, including filling cavities with filler including replacement of Filter frame with fresh air filter 20 (Micron) size 600 X 600 - 02 Nos of existing make and model at GNA Officers Mess complete all as specified and as directed.
Supply and fix DOL starter with single phase protection feature suitable for 10 HP 415 V, 50 Hz, 3 phase all as specified and as directed.
S & F Direct on line Starters 415V ,7.5 HP ,relay range 13-22 Amps 50 Hz ,3 phase complete all as specified and as directed.
S & F Direct on line Starters 415V , HP ,relay range 9-15 Amps 50 Hz,3 phase complete all as specified and as directed.
S & F MCCBs for motor protection for current rating 32-100 Amp,50 KA,415V,AC all as specified and as directed.
S & F Electronic motor protection relay with earth fault protection for overload current range 16-44Amps /32-88 Amps,240 V AC all as specified and as directed.
S & F Electronic motor protection relay with earth fault protection for overload current range 4-11 A/8-22A ,240 V AC all as specified and as directed.
S & F Surge Protection devices (SPDs) for protection against indirect lighting and switching surges type 2 I max 15 KA , 1P+N complete all as specified and as directed.
S & F Surge Protection devices (SPDs) for protection against indirect lighting and switching surges type 1+2 I max 50 KA , 3P+N complete all as specified and as directed.
S & F Surge Protection devices (SPDs) for protection against indirect lighting and switching surges type 2 I max 15 KA , 3P+N complete all as specified and as directed.
S & F SS enclosure for MCCBs suitable to accommodate upto 70 sqmm 3.5 core XLPE cable complete all as specified and as directed.
S & F SS enclosure for MCCBs suitable to accommodate upto 185 sqmm 3.5 core XLPE cable complete all as specified and as directed.
Supply & fixing 3 pole power contactors suitable for different equipments with auxiliary contact of 1 NO all as specified and as directed.
Supply & fix contactor relays suitable for different equipments. MAKE: L&T CAT No.CS94020 MXO 22E (2 NO + 2 NC ),AC-15 4 A or equivalent in Havells/scheider
Maintenance ,Servicing and attending complaints in case of emergency or breakdown, rectification of fault of Mechanical laundry consisting of Front loading washing machine 35KG Capacity electrically operated Basket size 950x 500mm 1HP wash motor with 36RPM drain water inlet 25mm and drain outlet 75mm heating coil 12KW door opening size 500mm and overall dimension 1120x 1440x 1730mm, Hydro Extractor Capacity 15KG 3HP drive motor Basket size 550x 300mm Extract speed 1000RPM Drain 65mm and overall dimension 800x1050x1110mm, Drying Thumbler 30KG capacity Basket size 950x 950mm 1HP drive motor 1 HP blower motor electrical heating coil 18/24KW overall dimension 1060x 1570x 1980mm, Flat bed press head and buck size 1500x 750mm 1HP suction blower and 18KW electrical heating coil overall dimension 1600x 1570x 1280mm, Air Compressor of 2HPand all other connected work services, installed at INHS Jeevanti all as specified and as directed. Notes: (i) Dryer Model No SDT/30/E and washer Model No SFL/35/E Major worn out/ defective part shall be measured and paid separately as supply only under respective item of sch.
Supply only Microprocessor card (part No SDT-30-001 ) for dryer all as specified and as directed.
Supply only Emergency switch (part No SDT-30-002 ) for dryer all as specified and as directed.
Supply only Contactor Rev forwarder (part No SDT-30-003 ) for dryer all as specified and as directed.
Supply only Contactor for heater (part No SDT-30-004 ) for dryer all as specified and as directed.
Supply only transformer (part No SDT-30-005 ) for dryer all as specified and as directed.
Supply only power supply (part No SDT-30-006 ) for dryer all as specified and as directed.
Supply only single phase preventor (part No SDT-30-007 ) for dryer all as specified and as directed.
Supply only MCB switch (part No SDT-30-008 ) for dryer all as specified and as directed.
Supply only heater (part No SDT-30-009 ) for dryer all as specified and as directed.
Supply only glass wire (part No SDT-30-010 ) for dryer all as specified and as directed.
Supply only drive belts (part No SDT-30-011 ) for dryer all as specified and as directed.
Supply only idler belts (part No SDT-30-012 ) for dryer all as specified and as directed.
Supply only main bearing (part No SDT-30-013 ) for dryer all as specified and as directed.
Supply only bearing block (part No SDT-30-014 ) for dryer all as specified and as directed.
Supply only bearing sleeve (part No SDT-30-015 ) for dryer all as specified and as directed.
Supply only idler bearing (part No SDT-30-016 ) for dryer all as specified and as directed.
Supply only idler block (part No SDT-30-017 ) for dryer all as specified and as directed.
Supply only idler sleeve (part No SDT-30-018 ) for dryer all as specified and as directed.
Supply only door glass (part No SDT-30-019 ) for dryer all as specified and as directed.
Supply only door gasket (part No SDT-30-020 ) for dryer all as specified and as directed.
Supply only Microprocessor (part No SFL-30-001) for Washer all as specified and as directed.
Supply only limit switch (part No SFL-30-002) for Washer all as specified and as directed.
Supply only Emergency switch (part No SFL-30-003) for Washer all as specified and as directed.
Supply only contactor (part No SFL-30-004) for Washer all as specified and as directed.
Supply only contactor healthy (part No SFL-30-005) for Washer all as specified and as directed.
Supply only drive valve (part No SFL-30-006) for Washer all as specified and as directed.
Supply only drive belts (part No SFL-30-007) for Washer all as specified and as directed.
Supply only idler belts (part No SFL-30-008) for Washer all as specified and as directed.
Supply only main bearing (part No SFL-30-009) for Washer all as specified and as directed.
Supply only sleeve (part No SFL-30-010) for Washer all as specified and as directed.
Supply only heater (part No SFL-30-011) for Washer all as specified and as directed.
Comprehensive Maintenance including monthly, quarterly maintenance and attending complaint in case of emergency or breakdown, Rectification of minor fault of Oil fired Incinerator of burning capacity 10kg/Hr with all its accessories ( Primary and Secondary Burner of 0.5 HP SP fully automatic mono block type, pressure jet with sequential controller, flame monitor, solenoid valves built in blower and motor fuel pump, voltage ignition transformer, ID FAn centrifugal type 3Phase 5 HP, Forced draft fan centrifugal type SP, 1HP, Recirculation pump 2 in Nos of 0.5 &0.4 HP, complete electrical control panel installed at INHS Jeevanti complete all as specified and as directed. Note: Major worn out/ defective part shall be provided and paid separately.
M&L for painting of complete oil fired incinerator installation comprising of Primary and secondary chamber , emergency vent, Ventury scrubber, Recirculation tank, chimney (stack) complete unit shall be painted externally with two coats of heat resistant silver coloured aluminium paint over a coat of primer. However, electrical panel and the fuel oil tank shall be painted with two coats of synthetic enamel paint over a coat of primer. Note:- Contractor should visit the site before quoting the rate.
Material and labour for re-winding of electrical motor of Ventilation system/Mechanical laundary with super enameled copper winding wire of required gauge by providing necessary insulating material, baking, varnishing etc complete all as manufacturing instruction and as directed. Note:- Rate quoted by contractor shall be included dismantling removing transporting re-fixing testing and commissioning all as specified and as directed.
Supply and fix ball bearing suitable for up to 7.5HP capacity motors/pumps after removal of old unserviceable bearing and making proper alignment and testing all as specified and as directed.
Comprehensive maintenance, including monthly for Inspecting, thoroughly check, detection of fault, repairing the minor fault and replacement of defective spare part if any including cleaning of dust from smoke detector and checking of continuity by the skilled technician/ Service Engineer to Fire Alarm system with 10 Fire zone and testing on completion of said job upto the full satisfaction of Engineer-in-Charge and as directed. Note : Spare/ part for replacement shall be paid and measured separately.
Supply & Fixing smoke detector suitable for 230V all as specified and as directed.
Supply & Fixing Pro detection panel for any zone out of fire zone of fire alarm system all as specified and as directed.
Supply & Fixing fire/flame detector (Repeater) suitable for 230V all as specified and as directed.
M & L for carrying comprehensive maintenance and technical services for 10 KVA UPS installed at Jeevanti Hospital ,Gomantak all as specified and as directed. (a) The service technician shall visit the UPS installation site for periodic preventive maintenance , checkup of the UPS system and the batteries every month.During this the system shall be cleaned and general performance shall be checked. (b) DC backup source shall be maintained properly by applying white petrolium jelly, checking/servicing of batteries etc as applicable. (c) Apart from the periodic preventive maintenance visits all break down calls on system arised during the contract period shall be attended quickly to keep the UPS system in operational condition. (d) Cost of all the minor spares required to put the UPS in working condition shall be borne by the contractor during the contract period and the rates for the same is deemed to be included in the rates quoted by the Contractor. (e) Response time during normal working hours shall be 4 hrs from the time of receipt of complaint and the resolution time shall be maximum 48 hrs based on the nature of complaint and replacement of components and parts etc. (f) Major Parts required for repair / replacement shall be measured and paid for seprately under relevant items of Schedule.
Inspecting, thoroughly check, detection of fault, repairing the minor fault and replacement of defective spare part if any including cleaning of battery bank terminal and applying petroleum jelly on terminal by the skilled technician/ Service Engineer to UPS of capacity upto 5 KVA capacity testing on completion of said job upto the full satisfaction of Engineer-in-Charge. Note : Spare/ part for replacement shall be paid and measured seperately.
Supply & Fixing in repair control card for AC to DC all as specified and as directed.
Supply & Fixing in repair Drive card for internal circuit all as specified and as directed.
Supply & Fixing in repair IGBT card 600Volts all as specified and as directed.
Supply & Fixing in repair VIGBT 150A, 600 Volts all as specified and as directed.
Supply & Fixing in repair control card for 5 KVA UPS all as specified and as directed.
Supply & Fixing in repair sealed maintenance free Battery 12V, 42 AH for UPS all as specified and as directed.
Supply & fixing in repair Cooling fan of UPS for capcity upto 10 KVA all as specified and as directed.
Supply & fixing i-sense Smart LED Linear Batten - 10W with in-built motion sensor with preprogrammed options of dimming,switching and change over, to suit customers requirement complete all as specified and as directed.
Supply & fixing i-sense Smart LED Linear Batten - 20W with in-built motion sensor with preprogrammed options of dimming,switching and change over, to suit customers requirement complete all as specified and as directed.
Supply & fixing Street Light-60W with cast aluminium housing, toughened glass diffuser,secondary optics,IP65/66, 10 KV SPD,>100 lm/watt.With built in DPSD dimmable system of options 50%/75% dimming at pre-determined timeslots including suitable size of GI pipe 1.2 m long bet to required shape making electrical connection to the fitting with Suitable size of service wire including GI elbow with proper clamp nut & bolt complete all as specified and as directed.
Supply & fixing DPSD Dimmable LED Street Light-72W with cast aluminium housing, toughened glass diffuser,secondary optics,IP65/66, 10 KV SPD,>100 lm/watt.With built in DPSD dimmable system of options 50%/75% dimming at pre-determined timeslot including suitable size of GI pipe 1.2 m long bet to required shape making electrical connection to the fitting with suitable size of service wire including GI elbow with proper clamp nut & bolt complete all as specified and as directed.
Supply and fix Solar LED Street light 30W All in one integrated new technology including suitable size of GI pipe 1.2 m long bet to required shape making electrical connection to the fitting with Suitable size of service wire including GI elbow with proper clamp nut & bolt , taking out Old defective fittings all as specified and as directed.
S & F LED flood light luminaire 3rd Generation 240W Pressure die cast housing , IP 66 rating making electrical connection to the fitting of high mast light with suitable size of wire including taking down of old defective fittings complete all as specified and as directed.
S & F LED flood light luminaire 20 W including taking down of old defective fittings complete all as specified and as directed.
S & F outdoor gate lights 10 W Square/round complete all as specified and as directed.
S & F Solar Gate light 5 Watts complete all as specified and as directed.
Supply & Fixing in repair sealed maintenance free Battery 12V, 7 AH complete all as specified and as directed.
Testing of lifts by lift Inspector authorized by Goa State Govt.
M/S G.N.POWAR
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .