Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹1.8 LAccepted-AOC VILLAGE TANGAORI SAS NAGAR MOHALI | S A S NAGAR | PUNJAB | 140103 | ₹1.8 L | L-1 | Accepted-AOC Allotment |
| 2 | L-2₹2.3 LRejected-Finance CHANDIGARH | ₹2.3 L | L-2 | Rejected-Finance due to higher |
Tender Value
₹4.0 L
EMD Value
₹7,946
Closing Date
4 Feb 2026, 11:00 amClosed
Executive Engineer, C.P. Division No.4, Chandigarh
Executive Engineer, C.P. Division No.4, Chandigarh
Special Repair of N/R/B Govt. Model High School, Dhanas, RC-II, Chandigarh for the Financial Year 2025-2026
2026_CHD_90283_1
CP4/2026/2554412
Open Tender
Civil Works
240 days
Special Repair of N/R/B Govt. Model High School, D
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹7,946
8 Apr 2026
28 Jan 2026
4 Feb 2026
28 Jan 2026
4 Feb 2026
28 Jan 2026
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand (zone-Ill) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources). (As per DSR 4.1.10)
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. (As per DSR 8.31)
Providing and fixing oxidised M.S. hasp and staple (safety type) conforming to IS : 363 with necessary screws etc. complete : (copper oxidized as per IS: 1378) 150 mm (As per DSR 9.67.1)
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. (As per DSR 9.83)
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 300x16 mm (As per DSR 9.96.1)
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 200x10 mm (As per DSR 9.97.3)
150x10 mm (As per DSR 9.97.4)
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125 mm (As per DSR 9.100.1)
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopper (As per DSR 9.101.2)
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (As per DSR 10.2)
Welding by gas or electric plant including transportation of plant at site etc. complete. (As per DSR 10.22)
Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. (As per DSR 10.31)
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick (As per DSR 11.26.1)
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. (As per DSR 11.27)
15 mm cement plaster: 1:4 (1 cement : 4 fine sand) (As per DSR 13.2.1)
6 mm cement plaster of mix : 13.16.1 1:3 (1 cement : 3 fine sand) (As per DSR 13.16.1)
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work (As per DSR 13.99.1)
Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) (As per DSR 14.5.1)
Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. (As per DSR 15.25)
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. (As per DSR 15.56)
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. (As per DSR 15.60)
Providing and fixing 60 mm thick high density rubber moulded precast cement concrete paver block grey/ colored/ polished/ designer (manufactured by vibro hydraulic pressure process) consisting of design mix of cement, sand and fine aggregate having designation M35 ISI marked including the cost of good quality color and hardening agents. The paver should be compiled with tensile strength and breaking load as per BIS 6717-1993 and shall be tested against resistance to bear as per IS 1237-1980 (specification for cement concrete floor tiles). The paver should be laid over layer of 50mm average thick sand to the required slope and requirement complete in all respects and to the entire satisfaction of Engineer in charge. (N.S.)
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board in existing steel frames well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 25 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. (N.S.)
Providing and fixing of cupboard shutter consisting of 19mm thick commercial board with lipping all around and fixed with chowkhat frame with piano hinges and screws etc. and provide with Alum. handle (with base plate) and magnetic catcher. The board surface is to be painted with two coats of special quality synthetic enamel paint after primer coat and preparation of surface, complete frame is to be fixed with iron nails etc. complete in all respects and to the entire satisfaction ofthe Engineer in charge. (N.S.)
Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc.,and then laying old cement concrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over after providing 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer- in-charge. Payment of any unserviceable material disposal to the dumping ground shall be made separately. (Based on DSR 16.83 & DSR 16.84) (N.S.)
Providing and applying cement based putty (Birla, Jk or equivalent) to the required finish complete in all respect and to the entire satisfaction of Engineer-in-charge. (N.S.)
Repair of deteriorated RCC Balconies, Chajjas, Beams, Walls, Ceiling, Column or other concrete surface having exposed rusted bars consisting of following operations (a) chipping of concrete surface 25mm thick average depth afterwards remocal of loose concrete and exposing the steel bars. Cleaning the surface properly to remove dust particles and rust from the steel bars. (b) Moistening the surface properly and applying arcylic polymer (acrocrete/ pidilite/ mastercrete or its equivalent) coating mixed with cement for proper bonding of old and new concrete in two coats 0.2kg per 1kg of cement. (c) Providing and fixing chicken mesh of standard size and 26 guage with steel reinforcement by using binding wire and nails complete. (d) Proving and placing of cement concrete l:11/2:3 having average thickness 1" (3/4" to 11/4" thick) mixed with arcylic polymer admixture @ 1kg per bag of cement and waterproof agent @ 400ml per 2 bags of cement including finishing the surface complete in all respect as per the direction and to the entire satisfaction of Engineer-in-Charge. (N.S.)
Providing and fixing of factory manufactured pre-cast concrete kerb of size 300mm X 300mm having 150 mm thickness with one edge semi rounded duly vibrated mechanically and compacted made of P.C.C. 1:2:4 duly cured and finished. the rate further include filling of joints between kerbs/ channels with cement mortar 1:2 complete in all respect and to the entire satisfaction of Engineer-in-charge. (N.S.)
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
technical_110416.pdf
techsummary_110416.pdf
finance_110416.pdf
BOQ Comparative Chart
xlsx
finsummary_110416.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.21 MB
BOQ_110416.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid