Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.2 LAccepted-AOC 19 HAREN MUKHERJEE ROAD HAKIMPARA SILIGURI 734401 DIST DARJEELING | SILIGURI | DARJEELING | WB | 734401 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹47.7 L+₹2.2 L (4.85%)Rejected-Finance NEW BANSBARI NH 34 PO JHALJHALIA DIST MALDA PIN 732 102 | MALDAH | WEST BENGAL | 732102 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹48.0 L+₹2.5 L (5.60%)Rejected-Finance SWAMIJI SARANI HAKIMPARA P O SILIGURI 734001 DIST DARJEELING WB | JALPAIGURI | WEST BENGAL | 734001 | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹48.1 L+₹2.7 L (5.84%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹48.2 L+₹2.7 L (6.03%)Rejected-Finance ATUL PRASAD SARANI DUDH MORE SILIGURI 734006 DARJEELING WB | JALPAIGURI | WEST BENGAL | 734006 | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
12 Feb 2025, 6:00 pmClosed
Garrison Engineer Sukna
Garrison Engineer Sukna, Post-Simulbari, Dist.-Darjeeling, WB-734009
REPAIR MAINTENANCE OF JOINERY FLOORING ROOFING TILING INTERNAL WIRING AT MES SUB STATIONS AND OTM MD ACCN AND PERIODICAL SERVICES AND OTHER ALLIED WORKS FOR RANGPUR VIHAR BOGRA VIHAR AND UMRAO SINGH ENCLAVE AREA UNDER OF GE SUKNA
2025_MES_694474_1
GE Sukna/8753
Open Tender
Civil Works
Works
270 days
Sukna
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE Sukna
₹90,000
Yes
6 Mar 2025
23 Jan 2025
14 Feb 2025
23 Jan 2025
12 Feb 2025
5 Feb 2025
23 Jan 2025 - 12 Feb 2025
Amount
Removing / cleaning of shrubs / grass / plants over RCC roof, chajja, wall of building of any plinth area and for any storeyed including scrapping of all algaes etc complete all as specified and directed by Engineer in charge.
M&L for repair to broken/damaged RCC chajjas by making good with PCC 1:2:4 type B1 or rendering 15 mm thick in cement mortar 1:4 mixed with water proofing compound to top and sides and rendering 5 mm thick to soffits in cement mortar 1:3 including necessary formwork reinforcement duly welded if required including demolition of broken/loose PCC or taking down old plaster at any storey of building complete all as specified and directed. Note:- Rate shall be included for necessary scaffolding and safety arrangement.
M&L providing Precast Reinforced cement concrete 1:2:4 Type B1 (using 20 mm graded stone aggregate) as in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, benching, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating and including necessary formwork complete all as specified and directed.
Supply only liquid water proofing compound complete all as specified.
M & L for brick work with sub class ‘B’ old size bricks straight or curved on plan n.exc. 6.00 m mean radius built in cement mortar 1:6 including demolition of old bricks complete all as specified and directed.
S&F 30 mm thick factory made flush door shutter solid core construction, with particle board core and plywood face panels,commercial type on both side complete all as specied and directed.
Taking down shutters of any description not exceeding 1.0 Sqm each complete all as specified and directed.
Taking down shutters of any description exceeding 1 Sqm but not exceeding 2 Sqm each complete all as specified and directed.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of mild steel tubes for top & bottom rails, mild steel frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, Panelling of wire gauze in lieu of plain colour PVC sheet. The wire gauze shall be wrapped on an additional square 8mm MS Solid tube and this tube shall be welded to MS tubes. The wire gauge shall be stretched to tighten firmly, suppling & fixing in the frame at site as per specification & drawing as per specification and drawing given on MES schedule Part – II (2010) complete all as specified and directed.
S&F 150 mm long aluminium anodized barrel tower bolts of extruded section complete all as specified and directed.
Supply and fix 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy complete all as specified and directed.
S & F 100 mm long medium weight, cold rolled mild steel Butt hinges with screws complete all as specified and directed.
S & F Continuous (Piano) hinges, mild steel, bright finished or electro galvanized, width of flaps (When open) 40 mm complete all as specified and directed.
S&F 150 mm Aluminium handles cast type, anodised and fixed complete all as specified and directed.
S&F Hasp and staple 100 mm safety type brass with mild steel pin, wire, including bolt to hinge plate and fixed with screw complete all as specified and as directed.
S & F Floor door stopper of Aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, Overall length of cover plate 140 mm complete all as specified and directed.
S & F Galvanized mild steel wire cloth, 0.63 mm dia of wire and average width of aperture 1.40 mm and fixed with tinned stacks, or galvanized wire staples complete all as specified and directed.
S&F Roof truss (framed) trussed, purlins, crane gantires of steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes confirming to IS 1161-1998 grade St-240 including one shop coat of zink chrome primer complete all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm TCT (total coated thickness) of any colour having tensile strength of 550 Mpa as in roof covering cladding to wall etc, fixed with self tapping screws complete all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm TCT (total coated thickness) of any colour having tensile strength of 550 Mpa as in roof covering cladding to wall etc, fixed with self tapping screws complete all as specified and directed.
M&L 4.5 mm thick cover fillets of standard hard board, 40mm wide, and fixing with screws complete all as specified and directed.
M&L in repairs for 18/19mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and directed.
M&L in repairs 12 mm thick prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work as in selves complete all as specified and directed.
M&L 75 mm thick, PCC 1:4:8, type D-2 (using 40 mm graded crushed stone aggregate) as in sub floor, sub base of floor, etc complete all as specified and directed.
M&L Non Skid ceramic coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exc.0.06 sqm but n. Exc. 0.11 sqm, in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including screed bed 15 mm thick in CM 1:6 finish even and rough complete all as specified and directed.
M&L Non Skid ceramic coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exc. 0.11 sqm but n. exc. 0.18 sqm, as in skirting/dado on vertical surfaces over etc.. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including screed bed 15 mm thick in CM 1:6 finish even and rough complete all as specified and directed.
M&L Non Skid ceramic coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exc. 0.11 sqm but n. exc. 0.18 sqm,as in skirting/dado on vertical surfaces over etc.. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including screed bed 10 mm thick in CM 1:4 complete all as specified and directed.
M&L cement concrete chequered tiles 300 x 300 x 25 mm thick with grey cement with pigment, set and jointed in neat cement slurry and pointed in coloured cement to match the surfaces as in floors laid over and including 15 mm thick screed bed in CM 1:4 complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removing the rubbish off the premises complete all as specified and directed.
M&L Rendering 15 mm thick on fair faces of brick work or concrete sur-faces in cement mortar 1:4 using water proofing compound @ 3% by wt of cement for finished even and smooth (without using extra cement) including taking down complete all as specified and directed.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished the surface even and fair complete all as specified and directed.
M&L for rendering 5 mm thick in CM 1:3 on ceiling finished even and smooth without using extra cement including taking down complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed.
M&L preparation of old decorated wall surfaces by brooming down or steel wire brushing scraping down smoke spot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and applying one coat of white wash complete all as specified and directed.
M&L for preparing old decorated wall or ceilings surfaces and including applying one coats of plastic emulsion paint complete all as specified and directed.
M&L for preparing newly plastered surfaces of ceilings and applying three coats of white wash complete all as specified and directed.
M & L complete removal of existing treatment of old plastered ceilings surfaces and applying two coats of white wash complete all as specified and directed.
M & L for preparation of newly plastered or previously untreated surfaces of walls and applying two coats of oil bound distemper over a coat of primer and over a thin layer of wall care putty to obtain smooth finish complete all as specified and directed.
M&L for prepration of new plastered surfaces of wall and applying two coat of oil emulsion distemper over a coat of alkali resistant primer over a thin layer of wall care putty to obtain smooth finish complete all as specified and directed.
M&L complete removal of existing treatment of old decorated wall surfaces and including applying two coats of oil bound distemper over a coat of alkali resistant primer and over a thin layer of wall care putty to obtain smooth finish complete all as specified and directed.
M&L preparation of old decorated wall surface and including applying one coat of oil bound distemper complete all as specified and directed.
M&L preparation of old decorated ceiling surface and including applying one coat of oil bound distemper complete all as specified and directed.
M&L preparation of old plastered surfaces of CGI / PGI sheets in roof and including applying one coat of anti corrosive paint complete all as specified and directed.
M & L for complete removal of existing treatment of old decorated surface and applying two coats of weather coat exterior emulsion paint inclding all necessary scaffolding of over head tank of 15 to 25 M staging complete all as specified and directed.
M&L preparation of new plastered wall surfaces and including applying two coats of cement base paint complete all as specified and directed.
M&L preparation of old plastered wall surfaces and including applying one coat of cement base paint complete all as specified and directed.
M&L complete removal of existing treatment of old decorated wall surfaces and including applying two coats of weather coat acrylic exterior emulsion paint over a coat of primer including all necessary scaffolding complete all as specified and directed. Note :- Rate shall be included for necessary scaffolding and safety arrangement.
M&L for complete removal of existing treatment of old decorated wall surfaces by Vacuum based sanding machine, removal of nails etc & filling cracks / hole with putty, applying one coat of primer using auto roller and applying a thin layer of wall care putty and sanding the same by Vacuum based sanding machine till obtaining even and smooth finish and applying two coats of oil bound distemper by auto roller complete all as specified and directed as per manufacturers instructions. Note:-Multipurpose mixer shall be used for uniform and proper mixing of putty.
M&L for preparation of newly plastered surfaces of wall by Vacuum based sanding machine, applying one coat of primer using auto roller and applying a thin layer of wall care putty and sanding the same by Vacuum based sanding machine till obtaining even and smooth finish and applying two coats of oil bound distemper by auto roller complete all as specified and directed as per manufacturers instructions. Note:-Multipurpose mixer shall be used for uniform and proper mixing of putty.
M&L for preparation of newly plastered surfaces of wall by Vacuum based sanding machine, applying one coat of primer using auto roller and applying a thin layer of wall care putty and sanding the same by Vacuum based sanding machine till obtaining even and smooth finish and applying two coats of exterior weather coat paint using auto roller complete all as specified and directed as per manufacturers instructions. Note :- Multipurpose mixer shall be used for uniform and proper mixing of putty.
M&L for complete removal of existing treatment of old decorated wall surfaces by washing with jet washer machine, removal of nails etc & filling cracks / hole with putty, applying one coat of primer using auto roller and applying a thin layer of wall care putty and sanding the same by Vacuum based sanding machine till obtaining even and smooth finish and applying two coats of exterior weather coat paint using auto roller complete all as specified and directed as per manufacturers instructions. Note:-Multipurpose mixer shall be used for uniform and proper mixing of putty.
M&L preparation of new wooden surfaces of any description, not otherwise described over 10 cm width or girth and including applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for preparation of old painted wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of Synthetic enamel paint (Ordinary tint) complete all as specified and directed.
M&L preparation of old decorated steel surfaces of any description, not otherwise described over 10 cm width or girth and including applying two coat of synthetic enamel paint complete all as specified and directed.
M&L preparation of old decorated steel surfaces of any description, not otherwise described over 10 cm width or girth and including applying one coat of synthetic enamel paint complete all as specified and directed.
M&L preparation of new steel surfaces of any description, not otherwise described over 10 cm width or girth and including applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L writing letters or figures (Block. Roman, Italic or Indian) n exc. 30 cm high with synthetic enamel paint complete all as specified and directed.
S&F 20 mm bore galvanised steel water tubing medium grade and including necessary GI fitting (such as bends, elbows, tees etc. and fixed to wall / ceiling or laid in / on floor and including taking down of existing pipe complete all as specified and directed.
S&F 25 mm bore galvanised steel water tubing medium grade and including necessary GI fitting (such as bends, elbows, tees etc.) and fixed to wall / ceiling or laid in / on floor taking down of existing pipe complete all as specified and directed.
Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc of 250 ltr to 500 ltr capacity PVC water storage tank without dismantling the tank incl writting the item "Tank Cleaning on ____" indication the date, month & year of cleaning on external wall of tanks walls with synthetic enamel paint all as specified and directed by Engr -in-charge.
Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc of 500 ltr to 1000 ltr capacity PVC water storage tank without dismantling the tank incl writting the item "Tank Cleaning on ____" indication the date, month & year of cleaning on external wall of tanks walls with synthetic enamel paint all as specified and directed by Engr -in-charge.
S&F in replacement 20 mm bore gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F in repairs 25 mm bore gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and directed.
S & F in repairs 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls complete all as specified and directed.
S & F in repairs 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls complete all as specified and directed.
S & F in repair 75 mm bore PVC (SWR) bends of any radius complete all as specified and directed.
S & F 110 mm bore PVC (SWR) bends of any radius complete all as specified and directed.
S & F in repairs 75 mm bore PVC (SWR) bends of any radius, fixed with cement solvent, with oval access door complete all as specified and directed.
S & F in repairs 110 mm bore PVC (SWR) bends of any radius, fixed with cement solvent, with oval access door complete all as specified and directed.
S&F in repairs 110 mm bore PVC (SWR) vent cowl fixed in position complete all as specified and directed.
Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floor and paving not exc. 15 cm thick (Below or above ground level) complete all as specified and directed.
Dismantling of corrugated or semi corrugated Asbestos Cement (AC) sheets in roof covering complete all as specified and directed.
Taking down carefully old unsv copper/aluminium point wiring (light, fan, socket or power) complete,including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets,sunken type box etc.and removing materials to store for keeping in safe custody for reuse at site or for taking credit and making good to disturbed surfaces of walls, floors etc with its original specification complete all as specified and directed by Engr-in-Charge.
M&L point wiring with 1.5 sqmm single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including non-metallic, rigid non mettalic PVC conduit (medium grade) concealed in wall / ceiling with and including 1.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel terminal boxes 60 mm deep, modular plate and frame on walls with 3 mm thick plastic laminated / hylam sheet cover, fixed on wall / other surfaces with brass screws for mounting or housing switches, socket outlets, fan regulators, etc. including all other fixing accessories for one light / fan / exhaust fan / call bell point controlled by one 5 / 6 Amps switch, all necessary cutting chasing (as required) and making good the disturbed surfaces including finishes to match with adjacent surfaces complete all as specified and directed. Note :- (i) Making good to match with the adjoining surface shall be included in the unit rate. (ii) Cutting chases shall be included in the unit rate.
All as per Sl. item No. 75.00 above but for point wiring modular plate one 5 / 6 Amps socket outlet point on independent board.
All as per Sl. item No. 75.00 above but for point wiring modular plate one 5 / 6 Amps socket outlet point on same board.
All as per Sl. item No. 75.00 above but for one 16 Amps socket outlet point on independent board with 2.5 sqmm cable and 2.5 sqmm earth wire
M&L point wiring with 1.5 sqmm single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including PVC casing caping (double lock pattern) and accessories on wall / ceiling surfaces etc. with and including 1.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel terminal boxes 60 mm deep, on walls with 3 mm thick plastic laminated / hylam sheet cover, fixed on wall / other surfaces with brass screws for mounting or housing switches, socket outlets, fan regulators, etc including all other fixing accessories for one light / fan / exhaust fan point controlled by one 5 / 6 Amps switch complete all as specified and directed.
All as per Sl. item No. 79 above but for one 3 / 5 Amps socket outlet point on independent board.
All as per Sl. item No. 79.00 above but for one 3 / 5 Amps socket outlet point on the same board.
All as per item No. 79.00 here-in-before but one 3 pin socket outlet / 15 amps on the independent board with other switches, with cables 2.5 sqmm size complete all as specified and directed
M & L concealed sub main wiring with 2 runs of 4.00 sqmm main wire along with 1 run of 4.00 sqmm earth wire (green in colour) single core FRLSH PVC insulated, unsheathed, multi-stranded, 1100 volts grade ISI marked copper conductor cable, drawn through and including adequate size rigid non-metallic PVC conduit (medium grade) with all fittings & accessories including cutting chases for conduits as required, sinking for terminal boxes, making good the disturbed surfaces including finishes to match with adjacent surfaces and including taking down complete all as specified and directed. NOTE:- Two runs of main copper conductor, one run of earth wire and one run of PVC conduit shall be measured as one unit length.
S&F switch piano flush type one way, 5 / 6 Amps, 240 volt complete all as specified and directed.
S&F switch piano modular type one way, 5 / 6 Amps, 240 volt complete all as specified and directed.
S&F switch piano modular type one way, 15 /16 Amps independent, 240 volt complete all as specified and directed.
S&F switch socket combination 3 pin 15 Amp, flush type universal complete all as specified and directed.
S&F switch socket combination 5 pin 6 Amp, flush type universal complete all as specified and directed.
S & F Socket outlet 5 Amps 3 pin flush type complete all as specified and as directed.
S&F socket outlet modular type 3 pin 5 / 6 Amps, 240 volts combined 2 modular complete all as specified and directed.
S&F socket outlet modular type 3 pin 15/16 Amps, 240 volts combined 2 modular complete all as specified and directed.
S&F MCB SP 6 to 32 Amp, 10 kA, 240V 'C' curve complete all as specified and as directed.
S&F MCB SPN 40 Amp , 10 kA, 240V 'C' curve complete all as specified and as directed.
S&F MCB TPN 63 Amp, 10 kA, 240V 'C' curve complete all as specified and as directed.
S&F ceiling rose, surface bakelite 65 x 50 mm three terminal complete all as specified and directed.
S&F in repair Deluxe, rotary, stepped type electronic fan regulator with 5 step, AC 50 Hz 240 Volts grade complete all as specified and directed.
S&F in repair electronic modular fan regulator, stepped type, white 120 W - 2 module complete all as specified and directed.
S&F in repair of modular fan regulator for BLDC Fans, stepped type, white 120 W - 2 module complete all as specified and directed.
Supply & Fixing of LED Bollard light fitting IP-65 designed as aluminium landscape for diffused lighting of capacity 8 watt, 230 volt AC complete all as specified and directed. Make : Havells CONE LED BOLLARD / PHILIPS / BAJAJ.
M &L of Earthing with galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick, buried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below ground level connected using galvanised iron earth lead wire 4 Sqmm as earthing electrode by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe (medium grade) and other end connected to earthing test point as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C both ways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth up to a distance not exceeding 50 Mtr etc all as shown on electrical plate No. 5 of MES Schedule Part-I complete including testing on completion. On testing after completion if the desired earth resistance is not obtained the earthing will be made again by the contractor at no additional cost and including dimantling complete all as specified and directed.
S&F Exhaust fan 250 mm sweep, non metallic plastic body, AC single phase, 230 V, 50Hz with & including self closing louvres, nuts, screws, bolts of specified sizes, electrical connection with twisted three core PVC insulated unsheathed flexible cord of size 0.75 sqmm copper conductor from ceiling rose to exhaust fan and writing MES number in 2 cm height with synthetic enamel paint and cutting wall for making hole writing MES number in 2 cm height with synthetic enamel paint and cutting wall for making hole and making good the disturbed surface to match the existing surface complete all as specified and directed. Note: The quoted rate is including for taking down and depositing old fan to MES Store.
S&F Exhaust fan 300 mm sweep, heavy duty, metal body, 1400 RPM (minimum), AC single phase, 230 V, 50Hz with bird guard, nuts, screws, bolts including electrical connection, writing MES number in 2 cm height with synthetic enamel paint and cutting wall for making hole and making good the disturbed surface to match the existing surface complete all as specified and directed. Note: The quoted rate is including for taking down and depositing old fan to MES Store.
S&F Exhaust fan 450 mm sweep, heavy duty, metal body, 1400 RPM (minimum), AC single phase, 230 V, 50Hz with bird guard, nuts, screws, bolts including electrical connection, writing MES number in 2 cm height with synthetic enamel paint and cutting wall for making hole and making good the disturbed surface to match the existing surface complete all as specified and directed. Note: The quoted rate is including for taking down and depositing old fan to MES Store.
S & F Bell push, flush type, 5 Amps single pole complete all as specified and as directed.
S&F modular type Bell push 6 Amps, 1 module 240 volts complete all as specified and directed.
S&F Bell electric, 240 volts, single pole complete all as specified and directed.
S&F LED batten light fitting 1 x 10 watt inverter (backup) type, 230 Volts, suitable for surface mounting, lithium ion battery with minimum 4 hrs backup time, extruded polycarbonate housing & extruded polycarbonate diffuser, lumen efficacy 100 Lm/watt (minimum), colour temperature 6500K (minimum), CRI 80 (minimum), IP-20 (minimum), PF 0.90 (minimum), in-built surge protection 3.5 KV (minimum) inlcuding all fixing arragnement and electrically connecting from ceiling rose to light fitting & taking down complete all as specified and directed.
S & F in repairs LED Bulk Head fitting 10 watt with Injection molded polycarbonate housing IP66, IK10, 3.5kV inbuilt surge protection, PF =0.95, total System Lumens not less than 1100 lm, 6500k CRI = 80, Operating Voltage range 140 V - 270 V. complete all as specified and as directed.
S & F in repairs Surface and wall mounted LED batten 20 watt 4ft long with Aluminum extruded housing , high quality polycarbonate diffuser & integrated Electronic Driver with IP20, PF 0.90, Efficiency not less than 110 lm/W color temp 6500k CRI = 80, Operating Voltage range 140 V - 270 V complete all as specified and as directed.
Supply and fixing in replacement of circular LED post top lantern 25W, 230 volts white in color, AC outdoor type,pressure die cast aluminium body and opal PC cover with IP 66 protection and IK07 rating with minimum efficacy of 120lm/W including taking down old unsv complete all as specified and as directed.
Supply and fixing in repair of MCB TPN DB 4 Way double door, IP-43 protection, isolated neutral bar, insulated busbar assembly, mechanical impact strength of IK08 complete all as specified and directed by Engr-in-charge.
Supply and fixing in repair of MCB SPN DB 12 ways double door, IP-43 protection, isolated neutral bar, insulated busbar assembly, mechanical impact strength of IK08 complete all as specified and directed by Engr-in-charge.
Supply and fixing in repairs round / square shape 6 watt 220 volts AC (White/Warm white on required basis) recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
All as per Sl. item No. 113.00 above but 15 watt 220 volts AC complete all as specified and directed.
Supply and fixing of Wall mounted air circulator high flow wave oscillating fan 400 mm (16 inches) 60Watt, AC single phase 230V of size complete all as specified and directed. Note : - Air circulator shall be deposited to the store yard of AGE E/M sukna without any extra cost.
M/S EASTERN ENGINEERING (BID ID -3237231)
S D CONSTRUCTION CO (BID ID -3237923)
M/s B. K. Ghosh and Co. (BID ID -3237899)
MS UNITY CONSTRUCTION CO (BID ID -3237559)
A K ENTERPRISES (BID ID -3237151)
GEETA CONSTRUCTION (BID ID -3237057)
METTLE WORKS (BID ID -3237625)
M/s Ranjit Kumar Saha (BID ID -3237485)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .