Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹2.9 LAccepted-AOC | 1 | Accepted-AOC quoted rates are justified. |
Tender Value
Refer Docs
EMD Value
₹5,538
Closing Date
2 Nov 2022, 6:00 pmClosed
Executive Engineer (E) BSNL Allahabad
Nawab Yusuf Road BSNL CTO building 2nd Floor Allahabad
Associated electrical Works.
2022_BSNL_131732_1
02/EE(E)/BED-AD/202-2023
Open Tender
Electrical Works
Item Rate
30 days
Nawab yusaf road BSNL CTO building Allahabad
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Yes
AO ( cash) BSNL GM allahabad BA
₹5,538
Yes
18 Nov 2022
17 Oct 2022
4 Nov 2022
17 Oct 2022
2 Nov 2022
17 Oct 2022
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required
Group -C
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
3 x 1.5 sq. mm
6 x 1.5 sq. mm
3 x 4 sq. mm
6 x 4 sq. mm
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
4 Module (125mmX75mm)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch
15/16 A switch
3 pin 5/6 A socket outlet
6 pin 15/16 A socket outlet
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
Upto 450 mm sweep
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 way , Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 100 Amp TPN swith in sheet steel enclosure complete with HRC fuses connections, testing and commissioning etc. as required. (M/S L&T FN 100 TPN Switch Disconnector SS Enclosure / SS make)
Supplying /Fixing 63 amp 16 KA 4 poles 415 volts, MCCB along with 4 pole metal enclosure to accommodate the MCCB complete with connection, testing & commissioning etc. as reqd.(Make Legrand DPX 160 with enclosure or SS make)
Supply and fixing of 4 ft. long 20 watt LED fitting on the surface of wall complete with all accessories connections etc. complete as required. (Make Bajaj/Havells /Philips or SS make)
Supply and fixing of Bulkhead Light fitting 10 watt LED fitting on the surface of wall complete with all accessories connections etc. complete as required. (Make Bajaj 10W LED Bulkhead 830321/Havells /Philips or SS make)
Supplying and Laying of 3.5 core x50sq mm PVC insulated and PVC sheathed Aluminium conductor XLPE power cable of 1.1 KV grade on the existing cable tray/ surface of wall / masonry open duct as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Supplying and fixing following way 100 Amp. 4 pole wall mounted bus-bar Chamber i/c Connection testing etc as required
4 way (M/s Havells Optima Series )
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .