Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.3 LAccepted-AOC PLOT NO 113 DOOR NO 1 746 2ND FLOOR VGP PUSHPA NAGAR MEDAVAKKAM CHENNAI 600 100 | CHENGALPATTU | TAMIL NADU | 600100 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹5.9 L+₹8,938 (1.54%)Rejected-AOC 4 13A PERIYAR NAGAR THANGAMAPURIPATTANAM METTUR DAM 636 402 SALEM DT TAMIL NADU | METTUR DAM | SALEM | TAMIL NADU | 636402 | L2 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹5,200
Closing Date
5 Feb 2024, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE MI NCTPS1 CH 120
O/o SE MI NCTPS1 CH 120
NCTPS I SE MI circle R M 23 24 MPM Dn Ventilation system Rectification of blower impeller fan assembly by renewal of the damaged impeller fan blades and commissioning of the blower A at air washer Unit I
2024_EB_412109_1
CE SE MI NCTPS I 222 23 24
Open Tender
Power/Energy Projects/Products
Works
30 days
Work
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹5,200
Yes
24 Sept 2024
23 Jan 2024
6 Feb 2024
23 Jan 2024
5 Feb 2024
23 Jan 2024
Amount
Charges for dismantling the ‘V’ Belts, Fly Wheel [Approximate weight 500Kg] of Blower Shaft and motor pulley with bush by using the chain blocks and lifting arrangement at centrifugal fan 'B’ Model No. 12 LLD at Air washer system Unit I. Including consumables and T&P's.
Charges for providing necessary supports at both sides of the blower shaft, dismantling the plummer block assembly, bearing assembly and air intake vane assembly etc. after cutting and removing of the supporting frames at both sides of the blower shaft, lifting the materials by using chain blocks if necessary scaffolding arrangements should be made and the materials should be kept at out side of the blower room as per the direction of the Engineer-in-charge. Including consumables and T&P's.
Charges for dismantling the front, top, side casing covers by cutting & removing of the bolt & nut, for lifting of the blower impeller assembly at Air Washer Blower 'A' at Unit II as per the direction of Engineer-in-charge. Including consumables and T&P's.
Charges for lifting of the blower shaft with the impeller assembly of approximate weight 1Ton (impeller dia 2030mm) by providing the necessary lifting arrangements using chain blocks and hooks fixed to the box channel at the top of the roof beams by welding at about 9mtr height from floor, lifting & moving the blower shaft, with impeller from middle of the blower, keep the whole blower assembly on the fabricated 2Nos. stand at both as per the direction of Engineer-in-charge. Including consumables and T&P's.
Charges for cutting & removing the corroded and damaged impeller fan blades and tie rods outer and inner periphery plates from the impeller fixing hub and shifted to outside of the blower room. Including consumables and T&P's.
Charges for loading the materials like fan assembly and shaft with hub by using chain blocks with supporting arrangements, taper lock bushes of fly wheel qty. 1No. make: Fenner No.5050, taper lock bushes of motor qty. 1No. make: Fenner No.3535 lifting & unloading from 9.5mtr. floor to ground floor, loading & unloading at vehicle for reconditioning work in workshop at town Including consumables and T&P's.
Charges for dismantling the impeller hub from the shaft by using the Special fixer and hydraulic jack, removing key from the keyway, cleaning the shaft hub key and keyway etc. and reassembling the hub in the shaft by using hydraulic jack in proper position aligning fixing the key in the keyway for locking the hub with shaft as per the direction of the Engineer in charge. [ Special fixer, hydraulic jack and other consumables contractor’s scope]
Fabrication charges for 3 blades per day.
Charges for renewing of 7 Nos. Fan blades (or) the rods.
Charges for conducting the dynamic balancing test on impeller assembly after fitting the impeller fixing hub at work shop end. Including consumables and T&P's.
Charges for air intake vane assembly, impeller assembly, fly wheel and shaft with cub unloading from vehicle and shifting blower room by using chain blocks with supporting arrangements. Including consumables and T&P's & Transport under TANGEDCO scope
Charges for re-assembling of air intake vane assemblies supporting frames, plummer block assemblies at both sides by using lifting arrangements, chain block etc. (if necessary cutting & welding of frames) fixing properly, tightening of the bolt & nuts after the proper aligning of supporting frames, plummer block assembly as per the direction of Engineer-in-charge. Including consumables and T&P's.
Charges for lifting the blower shaft with the impeller assembly of approximate weight 1Ton by using the lifting arrangements, chain block etc. from floor, lifting, moving the assembly, keeping the whole blower assembly at supporting stand at both sides of centrifugal fan ‘A’ at air washer Unit I as per the direction of engineer-in-charge. Including consumables and T&P's.
Charges for fixing the new self aligned double row taper lock bearings No.22326K with sleeve and lock washer to both side of the blower shaft and checking the tightness as per the direction of Engineer-in-charge. Including consumables and T&P's.
Charges for lifting the shaft with impeller assembly and keeping at plummer block assembly, checking the bearing at both sides after aligning and tightening of the plummer block assembly, greasing packing of the bearing, checking the free rotation of the impeller assembly, testing of the all bolts & nuts as per the direction of Engineer-in-charge. Including consumables and T&P's.
Charges for re-assembly of the front, top, side casing cover by fixing properly tightening of the bolts & nuts of necessary cutting & welding as per the direction of engineer-in-charge. (The consumables, bolt & nuts under contractor’s scope)
ANNAI ENTERPRISES
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .