Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.4 LAccepted-AOC NO 98 MARAPPA ROAD 1ST CROSS NAGAYANA PALYA M S NAGAR POST BANGALORE 560 033 | BENGALURU URBAN | KARNATAKA | 560033 | L1 | Accepted-AOC AOC | |
| 2 | L2₹48.7 L+₹1.1 L (2.32%)Rejected-Finance | L2 | Rejected-Finance Not L1 |
Tender Value
Refer Docs
EMD Value
₹98,500
Closing Date
5 Oct 2024, 6:00 pmClosed
GE(South) Bangalore
GE(South) Bangalore
SPECIAL REPAIRS TO SEWAGE LINE AND APPROACH PATH AT KKSA,STN HQ AND INTELLIGENCE OFFICE LIVING ACCN AND CERTAIN MAJOR REVENUE WORKS AND MINOR WORKS UNDER GE(SOUTH) BANGALORE
2024_MES_670289_1
8813/E8
Open Tender
Civil Works
Item Rate
180 days
GE(South) Bangalore
As per tender document
6 documents required · 6 mandatory
₹500
GE(South) Bangalore
₹98,500
Yes
20 Dec 2024
2 Sept 2024
12 Oct 2024
2 Sept 2024
5 Oct 2024
16 Sept 2024
Amount
Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc. 15 cm thickness (below or above ground level) complete all as specified and directed.
Removing building materials (Debris) to a distance of not exc. 5.0 Km (1 Metric tonne = 1 Load and One Cum = 1735 Kgs) out side MD Land Complete all as directed.
Demolition of brickwork or stone boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.
M&L for cement concrete 1:4:8 type D-2 (40 mm graded stone aggregate) as in foundations, filling & mass concrete complete all as specified and directed.(Note: PCC required for E/M works also shall be measured under this item)
M&L for precast cement concrete 1:6 block masonry type C1, 1:3:6 (20 mm graded agg) with solid blocks, exc 10 cm in width and setting in cement mortar 1:6 complete all as specified and directed.
M&L for providing cement concrete type C1, 1:3:6 ( 20 mm graded agg) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed complete all as specified and directed.
M & L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 incl finished even and smooth (without using extra cement)complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed.
Removing excavated material (soil) exc 1.5 Km but n.exc 5 Km and depositing where directed.
Demolition /breaking of drain pipes of any description set in CM 110 mm complete all as specified and directed.
Demolition /breaking of drain pipes of any description set in CM 150 mm complete all as specified and directed.
Demolition /breaking of drain pipes of any description set in CM 200 mm complete all as specified and directed.
M&L for salt glazed stoneware drain pipes laid in trenches 200mm dia and jointed complete all as specified and directed.
M&L for salt glazed stoneware drain pipes laid in trenches 150mm dia and jointed complete all as specified and directed.
M&L for PVC (SWR) Pipes single socketed, in any length with rubber ring joints laid in trenches 110mm bore and jointed complete all as specified.
M&L for concrete 1:3:6 type C-2 to drain pipes including packing under haunching against sides for 200 mm dia pipe complete all as specified and directed.
M&L for concrete 1:3:6 type C-2 to drain pipes including packing under haunching against sides for 150 mm dia pipe complete all as specified and directed.
M&L for concrete 1:3:6 type C-2 to drain pipes including packing under haunching against sides for 110 mm dia pipe complete all as specified and directed.
M&L for Pre cast RCC 1:2:4 type B1 for cover slab for man holes and set in cement mortar 1:4 complete all as specified and directed.
S&F mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (anealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching 150mm dia of pipe for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required complete all as specified.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching 200mm dia of pipe for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required complete all as specified.
M&L for preparation of newly plastered surfaces of wall and applying three coats of white wash on plastered surface complete all as specified and directed.
M&L for providing cement concrete 1:3:6 type C2 using 40 mm graded aggregate as in surface channels and drains complete all as specified and directed.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
M&L for preparing new steel surfaces of any description and apply one coat of red oxide zinc chrome and applying two coats of synthetic enamel paint complete all as specified and directed.
Surface excavation n. exe 30 CM deep and Averaging 15 CM deep and getting out fdn in soft/loose soil complete all as specified and directed.
M&L for 75 mm thick cement concrete type D-2, 1:4:8 using 40 mm graded crushed stone aggregate as in sub base of floors complete all as specified and directed.
M&L for sand filling under floors or in foundations including watering and consolidation as sand cushioning complete all as specified and directed.
M&L for Machine Pre cast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 grade with grey cement and pigment as in ramps/Hardstandings complete all as specified and directed.
M&L for Machine Pre cast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 100 mm thickness M-50 grade with grey cement and pigment complete all as specified and directed.
Blank
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 incl finished even and smooth without using extra cement complete all as specified and directed .
Taking down chowkat or frames with shutter (without taking off shutters from the frame) n. exc 1.5 sqm complete all as specified and directed.
M&L for applying two coats of Oil bound distemper on newly plastered surfaces incl preparing the surfaces and applying one coat of alkali resistant priming paint complete all as specified and directed .
M&L for preparation of new plastered surface and applying two coats of cement base paint over one coat of alkali resistant priming paint on walls complete all as specified and directed.
S&F 605 x 605mm Gl frame work for seamless ceiling comprising of Gl perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre.
S&F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm longcomplete all as specified
M&L for 4 mm thick non asbestos fibre cement building boards fixed or laid/inserted to timber/GI/Aluminium frame work with screws
M&L for Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and directed.
M&L for 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and directed .
M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 incl finished even and smooth (without using extra cement)complete all as specified and directed.
M&L for PCC 1:2:4 type B1 as in cills,steps,seismic and other similar bands,plinth courses ,string courses,lacing courses,parapets and railings upto 60cm in height,copings,kneelers,apex stones,bed plates,back filling of pressed steel door frames all as specified.
Removing excavated soil to a distance not exceeding 50 M and depositing where directed at a level not exceeding 1.5 M above the starting point all as directed.
M&L for 20mm thick screed bed or bedding layer of mortar 1:6 for laying floor finishes complete all as specified and directed.
M&L for colour chequered cement concrete tiles with grey cement and pigment 30cmx30cmx25 mm thick set jointed and pointed in neat cement slurry in floors complete all as specified and directed.
M&L PCC (1:2:4) type B2(using 40mm graded stone aggregate)as in foundations,filling & mass concrete complete all as specified and directed.
S&F FRP gratings 25mm thick of required length or breadth,open or close ended as approved and specified in relevant IS codes complete.
Blank
M&L for reinforced cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate as in slab supported on wall complete all as specified and as directed.
Formwork to soffits of suspended slab such as roof slabs ,floor slabs etc complete including fair finished all as specified and directed.
S&F mild steel TMT bars 6 mm to 8mm dia and over, cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (anealed) not less than 0.9 mm dia or securing with clips complete all as specified
S&F 450mm Reinforced concrete pipes,class NP3,laid and jointed complete with collars complete all as specified and as directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safe custody for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.
M&L point wiring, concealed by using 1.5 Sqmm PVC insulated sheathed, FRLS, copper conductor multistrand drawn in suitable sunken box and frame cover plate for mounting of modular switches/sockets as required at site and provn of PVC rigid non metallic conduit medium density ISI marked fixed with all fittings and all accessories complete including cutting chasing to the existing surface to conceal the conduit and making good to the disturbed surface to match with the existing surface provision of 1.5 Sqmm PVC insulated, FRLS copper conductor continuos earth wire connected to common earth dolly including complete all as directed.. (Note :- MS Sunken boxes, cover plates with frame switches, sockets shall be measured and paid seperately in an appropriate Item of Sch 'A' and laying/fixing of sunken box and cover with frame is included in quoted rate.
(a) One light/fan point controlled by one switch/push button
(b) One 3 pin 5 Amps socket outlet point on independent board
All as per item No.57 above but with 4.00 Sqmm cable for one 3 pin 15A socket outlet point on independent board
S&F ceiling rose surface bakelite 65 x 50mm 3 terminals all as specified and directed.
S&F switch modular type one way 5 Amps one module all as specified and directed.
S&F switch modular type one way 16 Amps one module all as specified and directed.
S&F switch socket combination, 2 in 1, 3 pin, 5 Amps modular type all as specified and directed.
S&F socket outlet 6/16 Amps modular type all as specified and directed.
S&F in repairs fan regulator,120 watts,electronic socket step modular type all as specified and directed.
S&F GI Flush in boxes and PVC cover plate with frame suitable for accommodating 03 Nos modular switch/socket etc complete all as specified and directed.
S&F GI Flush in boxes and PVC cover plate with frame suitable for accommodating 04 Nos modular switch/socket etc complete all as specified and directed.
Material and labour in replacement of sub main wiring concealed type with two runs of single core, PVC insulated unsheathe multi-stranded copper conductor cable of size 6.00 Sqmm, 1100 volts grade (FRLS) and one run of 6.00 Sqmm PVC insulated multi-stranded copper conductor cable (FRLS) for earth continuity conductor drawn through and including suitable size ISI marked rigid fire retardant PVC conduit with all necessary accessories such as bends, tees, junction boxes, elbows etc including cutting chasing existing surface to conceal the conduit and making good to the disturbed surface to match with existing surface complete all as specified and directed. Note : two runs of 6.00 Sqmm cable, one run of 6.0 Sqmm continuity earth wire and one run of PVC non metalic conduit with all necessary accessories will be measured as one length.
S&F in repair sheet metal enclosure single pole and neutral ,240 volts,8 way double door with 200 Amps rated bus bar complete all as specified and as directed.
S&F in repair sheet metal enclosure single pole and neutral ,240 volts,4 way double door with 200 Amps rated bus bar complete all as specified and as directed.
S&F in repair MCB SPN 32 Amps, 240 Volts,'C' curve complete all as specified and as directed.
S&F in repair MCB SP 5 to 32 Amps, 240 Volts,'C' curve complete all as specified and as directed.
S&F in repairs single pole and neutral enclosure with a two pin earth plug and socket complete with one single pole MCB of capacity 20 Amps all as specified and as directed.
Supply and fixing in repair LED luminaire 600 mm x 600 mm ( 2 feet x 2 feet), 36 watt,220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver,holders and LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases od suitable size complete with all accessories all as specified and directed by Engr-in-Charge.
Supply , erection, testing and commissioning 15 Mtr Height of High Mast system shaft rising and lowering type along with head frame , luminaries carriage. Suitable for 9 Nos luminaries with symmetrical arrangement and accessories including raising , lowering system drum winch 6mm dia SS wire rope , daily cable , connector integrated power tool motor , manual hand junction box lightning finial ( including separate wiring from control panel to each light fittings with 2.5Sqmm 3 core PVC cable Hot dip galvanized High mast pole and mounting bracket , with all mounting provisions including RCC foundation as per recommendation of OEM as per OEM drawing including necessary excavations and removal reqd for foundation including necessary support at bottom for luminaries carriage for repair including aviation obstruction lighting on top complete with dual pad lock arrangement near bottom for door vermin proof and weather proof complete all as specified with all fittings and accessories required for smooth function of Highmast system complete all as specified and directed by Engr- in - Charge.
Supply and fixing Supply and fixing LED flood light 200 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp
Blank
M&L for Breaking road, hard standing including excavation of sub base, soil upto the depth of 0.60 mtr and width 0.45 mtr by complete all as specified and directed by Engr-In-Charge.
Material & Labour for PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in foundation, mass concrete for road crossing etc., complete all as specified and directed.
Blank
M&L for sand cushioning in trenches for bricks of u/g cable with coarse sand laid dry in trenches with uniform thickness.
Supply and lay burnt bricks of sub class 'B' laid dry across in trenches for cable protection all as specified and directed.
Supply and laying and testing cable XLPE insulated , screened , PVC bedded galvanised steel or wire armoured electric power cables (heavy duty) 1100 volts grade wth stranded aluminium conductor of size 25 Sqmm 3.5 Core
Supply and lay pipe galvanized light grade including fittings 40mm dia for cable protection using road crossing complete all as specified and as directed by Engr-In-Charge.
Supply, testing, commissioning for Feeder pillar box made out door type of capacity for one incoming cable and 4 out going cable housing in sheet metal enclosure of MS sheet 3.15mm thick, CRCA sheet, angle iron frame of size 40x40x6mm including locking arrangement & painting with two coats of powder coated paint over a coats of metal primer, suitable foundation & platform etc complete all as specified and directed. following item comprises. (i) MCB TPN 40 Amp ( incomer ) (ii) Power contactor-03 Nos (iii) MCB SPN 16 Amp -04 Nos (iv) MCB SP 10 Amps--02 Nos (v) street light timer prewired for automatic on and Off of High mast lights (vi) Toggle switch as reqd (vii) RYB Indicator -01 set
Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the earth plate at a depth of not less than 1.5 mtr below ground level connected to galvanized iron strip 25 x 4 mm as earthing lead by means of bolts, nuts and washers made out of GI/steel earth strip protected by GI light grade pipe of 40 mm dia and connecting to main panel board/switch board/control board all shown in electrical plate No 3 of SSR Pt I incl PCC chambers in 1:2:4 and RCC cover slab with 8mm dia MS bars reinforced at 10 cm center to center both ways incl earth work like excavation, returning filling back disposal etc complete.
Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the earth plate at a depth of not less than 1.5 mtr below ground level connected to GI Wire 4 mm as earthing lead by means of bolts, nuts and washers made out of GI/steel earth strip protected by GI light grade pipe of 40 mm dia and connecting to main panel board/switch board/control board all shown in electrical plate No 3 of SSR Pt I incl PCC chambers in 1:2:4 and RCC cover slab with 8mm dia MS bars reinforced at 10 cm center to center both ways incl earth work like excavation, returning filling back disposal etc complete.
Srisrinivasaenterprises (BID ID -3120646)
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .