Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.3 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹9.6 L+₹28,609 (3.07%)Rejected-Finance | L2 | Rejected-Finance Quoted value is higher than lowest bidder | |
| 3 | Rejected-Technical | - | Rejected-Technical Non Responsive | |
| 4 | Rejected-Technical SURANGANI CHAMBA HIMACHAL PRADESH | CHAMBA | HIMACHAL PRADESH | 176317 | - | Rejected-Technical Non Responsive | |
| 5 | Rejected-Technical 1 VILLAGE SIRDI BHARMOUR BHARMOUR CHAMBA HIMACHAL PRADESH 176315 | CHAMBA | HIMACHAL PRADESH | 176315 | - | Rejected-Technical Non Responsive |
Tender Value
₹10.3 L
EMD Value
₹21,000
Closing Date
11 Mar 2024, 3:00 pmClosed
Sr. Manager (Contracts)
BSPS, NHPC Ltd, Surangani, Chamba, H.P.
Internal Wiring of Balika AshramUnder Construction at Chilli, Tehsil-Churah, Distt- Chamba
2024_NHPC_794943_1
NH/BSPS/CC/EW/59/2023-24/536
Open Tender
Electrical Works
Works
30 days
Tissa
Please refer Tender documents.
8 documents required · 8 mandatory
₹590
NHPC Ltd., Baira Siul Power Station, Surangani
₹21,000
19 Mar 2024
12 Feb 2024
15 Mar 2024
12 Feb 2024
11 Mar 2024
12 Feb 2024
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch phenolic laminated sheet suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Group-B)
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required---- 2x2.5 sq.mm + 1x2.5 sq. mm earth wire
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required---- 2x10 sq.mm + 1x6 sq. mm earth wire
Supply and fixing metal box of 150mm x 75mm x60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6A piano type switch, connections, painting etc as required.
Supply and fixing metal box of 180mm x 100mm x60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover infront including providing and fixing 6 pin 5/6 & 15/16A socket outlet and 15/16A piano type switch, connections, painting etc as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (6 way, double door)
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (12 way, double door)
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Single pole)
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (63 amps)
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc, including supplying and fixing ball and socket arrangement, 2 nos. down rods of 20mm dia x 1.6mm thick steel conduit upto 30cm length, painting and wiring the down rods & connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
Providing & Instatlation of exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above Fan, making good the damages, connections,testing and commissioning etc as required. (Exhaust fan, Light duty, (Domestic) 300 mm sweep)
Providing & Instatlation of Stationary storage type electric Water Heater (Geyser) of various sizes by means of expasion bolts with nut and washers, includingembedding of expansion bolts in the wall, providing and fixing of Non-return valve, dead weight safety valve, 02 Nos CP connection rods 18 " long making good the damages, electrical connections,safety valve connections, testing and commissioning etc as required. 25 Ltrs capacity water Heater, Cat-B
Supply, installing, testing and commissioning of following capacity end feed unit made of 1.6mm thick sheet steel enclosure duly painted with powder coating to existing rising mains complete with TPN disconnector FSU and HRC fuses mounting stand, cable and box, brass compression gland , connections, earthing etc as required.(200AMP)
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 4mm dia copper wire on surface or in recess for loop earthing as required.
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
Fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required.
Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.
sanjeev sharma
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .