Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.0 LAccepted-AOC 6 51 OLD POST OFFICE LANE UDHAMPUR 182101 | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L1 | Accepted-AOC Being L1 bidder | |
| 2 | L2₹22.3 L+₹33,425.38 (1.52%)Rejected-AOC HOUSE NO 97 MOHALLA AFGHANA GALI KRISHAN DWARA JAMMU | JAMMU | JAMMU | JAMMU AND KASHMIR | L2 | Rejected-AOC Other than L1 bidder | |
| 3 | L3₹26.0 L+₹4.0 L (18.2%)Rejected-AOC | L3 | Rejected-AOC Other than L1 bidder | |
| 4 | L4₹27.3 L+₹5.3 L (24.3%)Rejected-AOC | L4 | Rejected-AOC Other than L1 bidder | |
| 5 | L5₹28.4 L+₹6.5 L (29.5%)Rejected-AOC 361 BEHIND DAV SCHOOL JAWAHAR NAGAR SRINAGAR 190008 | SRINAGAR | JAMMU AND KASHMIR | 190008 | L5 | Rejected-AOC Other than L1 bidder |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
30 Apr 2025, 6:00 pmClosed
Lt Col Devdutt Deshpande
GE (AF) Thoise
REPAIR/ REPLACEMENT OF LT UG CABLE, JUNCTION BOX AND CONNECTED WORKS AT AF STN THOISE UNDER GE (AF) THOISE
2025_MES_703286_1
GEAF/T-16/E8
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
THOISE STATION
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (AF) Thoise
₹70,000
24 Jul 2025
2 Apr 2025
7 May 2025
2 Apr 2025
30 Apr 2025
16 Apr 2025
Amount
Excavation in trenches n.exc. 1.5 mtr wide and n.exc 1.5 mtr deep for foundations of poles/stays/cable etc not exc 10 Sqm area on plan and getting out in Hard/Dense soil complete all as specifed and as directed by Engineer-in-Charge.
Returning filling in including spreading levelling, watering and well ramming in layer each not exc. 25 cm thick in a soft/loose soil complete all as specified and directed by Enginer-in-Charge.
Removing surplus soil to a distance not exc. 50 mtr and depositing where directed at a level n.exc. 1.5 mtr above the starting point complete all as specified and directed by Engr-in-Charge.
M&L for PCC cable cover Class LV, Type I, flat, size 250 mm x 150mm x 40mm laid Flat in trenches over the cable with length 250mm perpendicular to the direction of cable, adjacent/ abutting each other complete all as specified and directed. Note:-Excavation and earth work to be measured and paid for separately
Sand cushioning to protection of underground cables, laid 8 Cm before laying and 15 Cm after laying of cable, and punned to form an overall layer of 18 Cm thick, complete all as specified and directed by Engineer-In-Charge. Note: Punned thickness shall be measured.
M&L for in repair / replacment XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 16.0 Sqmm, 2-core, laid in trenches or passing through pipes, including suitable lugs and accessories for making connections at both ends, complete all as specified and as directed.
All as per Srl Item No 6 above but of size cross-sectional area 16.0 Sqmm, 4-core.
All as per Srl Item No 6 above but of size cross-sectional area 25.0 Sqmm, 4-core.
All as per Srl Item No 6 above but of size cross-sectional area 35.0 Sqmm, 4-core.
All as per Srl Item No 6 above but of size cross-sectional area 50.0 Sqmm, 3.5-core.
All as per Srl Item No 6 above but of size cross-sectional area 70.0 Sqmm, 3.5-core.
All as per Srl Item No 6 above but of size cross-sectional area 95.0 Sqmm, 3.5-core.
All as per Srl Item No 6 above but of size cross-sectional area 120.0 Sqmm, 3.5-core.
S & F in replacement Cable jointing kit for 1.1 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 to 120 sqmm, complete all as specified and directed. Make : Denson/ M Seal/ Raychem
Replacement of old unserviceable/ damaged MCCB with new MCCB, four pole, 415 Volts, adjustable thermal and fixed magnetic setting,63 Amps with breaking capacity 16 KA, having indicating lamp, Ics=100% Icu and as per IEC 60947-2, complete all as specified and as directed by Engineer-In-Charge. Make: Schneider cat part No- LV426167 or equivalent in in L&T/ Legrand/ ABB/ Merlin Gerin/ Siemen/ havells
Replacement of old unserviceable/ damaged MCCB with new MCCB, four pole, 415 Volts, adjustable thermal and fixed magnetic setting 125 Amps with breaking capacity 16 KA, having indicating lamp, Ics=100% Icu and as per IEC 60947-2, complete all as specified and as directed by Engineer-In-Charge. Make: Schneider cat part No- LV426167 or equivalent in in L&T/ Legrand/ ABB/ Merlin Gerin/ Siemen/ havells
Supply, installation, testing and commissioning of electric LT Feeder Pillar Box, outdoor, cubical type, Pedestal mounted, factory made, CPRI approved,, Al Bus Bar 400 Amps fabricated out of 3.4mm thick mild steel sheet mounted on frame of mild steel angle iron 40x40x6mm also comprising of following Inccoming:- (a) Change Over Switch 200 Amps -01 Nos (b) MCCB, four pole, 200 Amps, 415 Volts, adjustable type, with breaking capacity 35 KA- 02 No ( incl 02Nos Amp meter). (c) MFn Meter V, A, F, kW, KVA, kVAr, kWh, , PF etc Make L&T , Equivelent in Seimns and Schinider -01 Nos (e) Suitable Contacter, relay,& circuit protection device Outgoing (i) MCB 4 pole 415 Volts TPN of capacity 63 amps thermal magnetic release adjustable type of breaking capacity 10 KA-06 No (incoming) With addition to Amp meter-06 (ii) MCCB 4 pole 415 Volts of capacity 40 amps thermal magnetic release adjustable type of breaking capacity 16 KA-02 Nos (outgoing) With addition to Amp meter-02
Attanding day to day complaints for maintenance and repair of LT Network of any type and any specifications or any accessories related to Electric Supply of any descriptions, fitted/ fixed on poles, buildings or watching towers of any heights and any location, and re-fixing the same after necessary repairs/ replacement of defective parts including rectifying the same as per directions by concerned JE E/M and Engineer-In-Charge, at various locations, complete all as specified and directed by Engineer-In-Charge.Note: (i) Cost of T&P, ladder or mechanical lift shall be deemed included in quoted rate. (ii) Supply of spare parts of light fittings shall be measured and paid separately.
Note: The work under subject BoQ (item No. 1 to 19 ) is meant for maint of External Electric Supply in AF Stn Thoise under GE(AF ) Thoise. The work shall be executed on ground on required basis. Contractor shall deploy sufficient resources to keep smooth working of External Electric Supply in the AF station. Contractor or his representative will daily attend the complaints at E/M complaint cell and in addition any breakdown shall be communicated to contractor or his representative by concerned Engineer-in-charge/JE E/M through phone call, text message, complaint slip and or in writing through site order book or through other means. Non complying of attending breakdown by contractor within 24 hours after notify the complaint, recovery @ Rs 1500/- per day shall be recovered from contractor's payment for each complaint so notified.
M/S RAVI KUMAR (BID ID -3286455)
FORTUNE STAR (BID ID -3286282)
Ms Salaria Builders (BID ID -3286346)
M/S TRADE LINK (BID ID -3290010)
EESSI (BID ID -3285030)
FANGALIA TRADERS (BID ID -3285035)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .