Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹7.2 LAccepted-AOC | 1 | Accepted-AOC LOWEST AND REASONABLE | |
| 2 | 2₹9.8 L+₹1.5 L (17.4%)Rejected-Finance 01 DUDWAN KUPWARA DUDWAN KUPWARA JAMMU KASHMIR 193222 | KUPWARA | JAMMU AND KASHMIR | 193222 | 2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | 3₹12.5 L+₹4.1 L (49.8%)Rejected-Finance DHARAM SALA SINGHAN CHADOORA DISTT BUDGAM J K | CHADOORA | BUDGAM | JAMMU AND KASHMIR | 3 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
21 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF SGR
CWE AF SGR
REPAIR MAINT OF HT NETWORK AT AIR FORCE STATION SRINAGAR
2020_MES_379390_1
CWE(AF)SGR/SGR-15/2020-21
Open Tender
Civil Works
Item Rate
180 days
AF STATION SGR
AS PER NIT
8 documents required · 8 mandatory
₹500
GE AF SRINAGAR
₹30,000
Yes
3 Dec 2020
21 Sept 2020
23 Oct 2020
21 Sept 2020
21 Oct 2020
6 Oct 2020
60 days
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of underground cable and getting out in any type of soil complete all as specified and directed.
Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cm thick in soft / loose soil complete all as specified and directed.
Removal of surplus soil to a distance not exceeding 50 Mtr and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed.
Material and Labour for sand cushioning in trenches including spreading and consolidation in layers of 8cm thick before laying the cable & 15 cm thick after laying the cable and punned down to form a bed complete all as specified and directed. Note:- Punned down thickness will be measured for payment.
Supplying and laying Un-reinforced precast concrete cable cover ' factory made' of class HV, Type 1 with peak, of size 300 mm x 180 mm x 40 mm complete all as specified and directed.
Laying only Un-reinforced precast concrete/brick cable cover 'retrived during excavation vide item no. 1 &.8 (cable cover retrieved during excavation and found suitable for reuse shall be stacked saparately and passed by engineer-in-charge) complete all as specified and directed.
Supply and fix in replacement 100 mm dia galvanized iron tube light grade for protection of cable at road crossing complete all as specified and directed.
Taking out carefully HT under ground old unserviceable cable of any size and taking out brick/ concrete cable covers from trenches and keeping aside for re-use complete all as specified and directed.
Supply, Laying, jointing, and testing of under ground cables XLPE insulated screened PVC bedded galvanized steel strips armoured electric power cable (heavy duty) with aluminium conductor HT 11000 volts grade(Earthed) and cross sectional area 120 sqmm 3 core conforming to latest IS and ISI marked complete all as specified and directed.
Laying only of under ground cables XLPE insulated screened PVC bedded galvanized steel strips armoured electric power cable (heavy duty) with aluminium conductor HT 11000 volts grade(Earthed) and cross sectional area 120 sqmm 3 core confirming to latest IS and ISI marked complete all as specified and directed. (Note: Cable shall be issued under sch 'B' free for laying)
Supplying, jointing & testing in replacement/repairs out door type cable jointing kit for 11KV (Earthed)grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and as directed.
Supplying, jointing & testing in replacement/repairs out door type cable jointing kit for 11KV (Earthed)grade cable for outdoor straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and as directed.
Supplying, jointing & testing in replacement/repairs indoor type cable jointing kit for 11KV (Earthed)grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and as directed.
Material and labour for painting to preparation of old steel tubular poles, channels brackets of 2pole/4pole/6pole structure of steel tubular HT poles up to full length complete with two coat of anti corrosive aluminium paint including painting of cross arms,channels,GI pipe etc complete including strip painting with Red and black synthetic enamel paint and aluminium paint up to 1.5 mtr length in alternator layers of 30 cm width including writing of pole Nos complete all as specified and directed.
(a) 2pole structure
(b) 4 pole structure
(c ) 6 pole structure
Supplying and fixing in replacement out door, triple pole, gang operated switch single break, tilting type suitable to vertical/horizontal mounting consisting of hot dipped electro plated galvanised channel iron base with drop out fuse having 15 Nos insulators 11 KV, copper alloy tinned contacts, copper or chromium plated MS arcing chains capable of making and breaking the magnetising current complete with horizontal bar, GI pipe as down level coupling and operating handle with locking arrangements and drop out fuses working voltage 11000 volts 200 Amps including testing complete all as specified and as directed.
Dehydration/filtration of transformer oil of transformer in position till the dyelectric strength of transformer oil is achived not less than 50 KV when measured at 2.5 mm gap for one minute including testing of sample before and after Dehydration/filtration and filling of new transformer oil as required for top up upto required oil level complete all as specified and as directed. Note : - New transformer oil as required shall be measured and paid separately under respective item as supply only.
Supply only new transformer oil with dielectric strength not be less than 60 KV when measured at 2.5 mm gap for duration of one minute complete all as specified and directed.
Material and labour for repairs to Earthing for sub station equipment (Transformer, GOD and feeder pillar box) with and incl galvanized MS earth plate of size 600 x 600 x 6.00 mm thick buried vertically in ground to a depth not less than 2.25 mtr below ground level the earth plates surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 150mm on all side, excavation, earthwork returning filling in removal of surplus soil up to 50m earth strip 32 x 6mm bolted and reverted to earth plate at one end and connected to metallic bodies of HT/LT equipments etc GI earth strip encased in and incl 50mm NB GI light grade pipe with all fittings from upper edges of earth plate to body of equipment fixed with and incl 25 x 6mm F.I clamps, bolts, nuts and washer including providing 40mm dia GI pipe light grade from earth plate to 300mm above ground level for watering with 40mm dia MS dead plug with funnel and wire mesh complete all as specified and directed. Note: Earth resistance should not be less than 2 ohm
Supply, installation and testing in replacement of Lighting Arrestor expulsion type for out door use complete with all fittings transmission class discharge capacity 65 kilo Amps suitable for 11000 V including bracket, clamps, nuts and washers and connecting to earth wire complete all as specified and as directed.
Repair / maintenance and servicing of step down distribution transformer 11 KV/0.433 KV of following capacity and of any make comprising of following work services complete all as specified and directed. (a) Disconnecting carefully of cable end termination of 11 KV side and 433 volt side and transporting to trade work shop. (b) Opening of top cover by removing nuts, bolts and all mounting accessories and conservator tank. (c) Draining out transformer oil and keeping aside in barrel for re-use and then again pouring back after necessary filteration and dehydration including top-up with new transformer oil to make up the reduced quantity. After dehydration dielectric strength of transofrmer oil should not be less than 40 KV. (d) Replacement of top gaskets. (e) Servicing of tap changing gears by cleaning and polishing tapping contact points. (f) Labour only for cleaning of bush and stud both HV/ LV side and refixing the same with new cock sheet as required. (g) Replacing unserviceable stud and bush as required as directed by Engr-in-Charge. (h) Reconnection of all cable terminals HV & LV sides and refixing the top cover after replacement of gaskets, conservator tank in position. (j) Dehydrating of Silica Gel in breather and replacing with new Silica Gel to make up the reduced quantity. Colour of Silica Gel should be deep Sky Blue. (k) Connecting HT & LV side with existing incoming and outgoing cables including reconnection of earth strip/lead. (l) Transporting back to site and reinstalling at location as directed by Engr-in-Charge. Notes : (i) Spare parts (if required) will be measured and paid separately at "Supply only"rates. (ii) Colour of Silica Gel shall be Deep Sky Blue.
Transformer of 63 KVA Capacity
Transformer of 100 KVA Capacity
Transformer of 200 KVA Capacity
Transformer of 500 KVA Capacity
S&F High voltage coil double paper insulated conductor of same gauge as per existing and all insulating material, varnishing with vacuum impregnation and making of coil (four coil per limb) suitable for following capacity of step down transformer of copper wound as indicated :-
(a) Copper wound 315/160/200 KVA Transformer
(b) Copper wound 100/63 KVA Transformer
Reconditioning of copper wound Low voltage coil including double paper insulated & all necessary insulating material varnishing with vacuum impregnation and making of limb for the following capacity of step down transformer.
(a) Copper wound 200/500 KVA Transformer
(b) Copper wound 100/63 KVA Transformer
Opening up top cover of step down transformer of following capacity in position after disconnection of all electrical connections for inspection for any leakage from bushings, gaskates, tighting the same including replacing the bushing/gaskets as required including tightning of all loose connections and refixing the top cover after neccesary repair works complete all as specified and directed by engr-in-charge. Note : - Replacement of worn out/defective parts shall be measured under relevant items of schedule ‘A’ and including draining off oil & refilling the same as per requirement of site for opening of top cover of step down transformer. Rate quoted in respect of serial Item No 23 shall be inclusive of labour charges for fixing in respect of serial item Nos 24 to 31. Contractor shall quote rates accordingly.
Transformer of 75 KVA Capacity
Transformer of 160 KVA Capacity
Transformer of 200 KVA Capacity
Transformer of 300 KVA Capacity
Transformer of 500 KVA Capacity
Supply only HV porcelain bushing of 11 KV grade with gasket complete all as specified and as directed.
Supply only LV porcelain bushing of 1100 volts grade with gasket suitable for the following capacity of transformer :-
(i) 63 KVA to 160 KVA
(ii) 200 KVA to 400 KVA
(iii) 500 KVA
Supply only LT brass stud with 5 Nos brass nut, brass washers, check nuts, conical rubber bush for the following capacity of Transformer.
(i) 63 KVA to 160 KVA
(ii) 200 KVA to 400 KVA
(ii) 500 KVA
Supply only HT brass stud with 3 Nos brass nut, brass washers, check nuts conical rubber bush for the following capacity of transformer complete as specified and directed.
(i) 63 KVA to 160 KVA
(ii) 200 KVA to 400 KVA
(ii) 500 KVA
Supply only tap changer rotary type suitable up to 500 KVA capacity Transformer complete all as specified and as directed.
(i) 63 KVA to 160 KVA
(ii) 200 KVA to 400 KVA
(ii) 500 KVA
Supply only breather with fresh filling of silica-gel (colour of silica gel should be deep sky blue) 0.5 KG capacity in non metallic breather of transformer up to 500 KVA capacity complete as specified and directed.
Supply only oil level indicator suitable for Transformer up to 500 KVA capacity complete as specified and directed.
Supply only Oil temperature gauge as per IS specification suitable for Transformer up to 500 KVA capacity complete as specified and directed.
Preparation of old painted surfaces of transformer and painting with two coats of synthetic enamel paint including writing SM No and MES No with approved colour paint with letters 30 mm high for the following capacity of transformer complete as specified and directed. :-
(i) 63 KVA to 200 KVA
(ii) 250 KVA to 400 KVA
(ii) 500 KVA
M/S Wani and Sons
M/s Jaipal Associates
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .