Executive Engineer
Executive Engineer, CD-I, APWD, Rangat
Supplying, installation, testing and commissioning of 01 No. 2.0 Ton - Room NO. 33 - and 10 Nos. 1.5 Ton - Room NO. 4,5,6,35,39,37,41 - 01 Each 1.5 Ton and Room No. 42 - 02 Nos. 1.5 Ton - capacity split type Inverter Air Conditioner at CHC, Rangat
2025_APWD_17211_1
07/DB/CD-I/RGT/2024-25
Open Tender
Miscellaneous Works
Item Rate
60 days
Rangat
Please refer Tender documents.
10 documents required · 10 mandatory
₹0
₹24,413
20 Jan 2025
9 Jan 2025
17 Jan 2025
9 Jan 2025
17 Jan 2025
9 Jan 2025
Amount
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
4 Way, Double Door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
4 way (4 + 12), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying, Installation, testing and Commissioning of 02 Ton capacity 5 star rating, inverter High wall mounted split type Air Conditioner (1 phase 220 Volt) with maximun cooling capacity of atleast 7000 Watts Make: HITACHI YOSHI 5400FXL FROST WASH INVERTER-R32-RASG522PCAISF or of equivalent cooling capacity in BLUE STAR/ VESTAR /IFB /MITSUBISHI/ O GENERAL/ DAIKIN with copper codenser coil and rotary compressor i/c providing standard length of refrigerant copper pipe kit, cutting, drilling holes on the wall for passing gas pipes, fixing suitable size PVC pipe on the wall through the holes and cementing, painting to give an even look and smooth finish, wrapping PVC non adhesive white tape over insulation of gas pipe etc. as required and as per the direction of EIC.
Supplying, Installation, testing and Commissioning of High wall mounted split type Inverter Air Conditioner of 1.5 Ton capacity with atleast 5 star rating and copper condenser of Make: HITACHI YOSHI 5400FXL FROST WASH INVERTER-R32-RAS.G518PCA1SF or its equivalent to IS specification with all accessories i/c cutting, drilling holes on the wall for passing gas pipes, fixing suitable size PVC pipe on the wall through the holes and cementing, painting to give an even look and smooth finish, wrapping PVC non adhesive white tape over insulation of gas pipe etc. or ISI brand ,Stand/bracket for outer unit,connections etc. as required as per direction of Engineer - in - Charge.
Supplying and fixing of 5 KVA Voltage Stabilizer suitable for 2 ton Air Conditioner as required of Make V Guard Model VND 500 (Voltage Range 150V - 285V, 15 Amps) or equivalent.
Supplying and fixing of 4 KVA Voltage Stabilizer suitable for 1.5 Ton Air Conditioner as required of Make V- Guard VEW 400 STANDARD (voltage Range 110V - 280V, 15 Amps) or equivalent.
Supplying and fixing of Pre-fabricated stand for Keeping outdoor units of 1 Ton/1.5 Ton/2 Ton capacity split type AC as required.
ROYAL ENGINEERING WORKS (BID ID -50614)
NAVJEEVAN ENTERPRISES (BID ID -50449)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .