Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.1 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹28.3 L+₹3.0 L (12.0%)Rejected-AOC C 223 MIANWALI COLONY GURGAON 122001 HARYANA | GURUGRAM | HARYANA | 122001 | L2 | Rejected-AOC Rejected other than L1 | |
| 3 | L3₹35.1 L+₹9.8 L (38.9%)Rejected-AOC | L3 | Rejected-AOC Rejected other than L1 |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
2 Nov 2024, 6:00 pmClosed
GE (AF) Gurgaon No 1
GE (AF) Gurgaon No 1 Near Atul Kataria Chowk Gurgaon-122001
CA NO. GE AF NO.1/GUR-53/2024-25 SPECIAL REPAIR TO ROOF OF TECHNICAL STORAGE HOUSES AND CERTAIN OTHER MINOR WORK AT AF STATION GURGAON UNDER GE (AF) GURGAON NO. 1.
2024_MES_677842_1
GE (AF) Gurgaon No 1/GUR-53/2024-25
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (AF) Gurgaon No 1
All as per NIT
10 documents required · 10 mandatory
₹500
GE (AF) Gurgaon No 1
₹94,000
Yes
16 Dec 2024
3 Oct 2024
4 Nov 2024
3 Oct 2024
2 Nov 2024
19 Oct 2024
Amount
Taking down carefully existing water proofing treatment including screed bed and disposal of rubbish outside of MD land and hacking for key, scrubbing down with water complete all as specified and directed
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Material and labour for PCC 1:2:4 type B1 (using 20mm graded stone aggregate as in seismic and other similar bands, plinth courses, lacing courses parapets , copings, kneelers, bed plates etc complete all as specified and as directed
M&L for rendering 15mm thick in cement mortar 1:3 on concrete surfaces complete all as specified and directed.
Supply only liquid water proofing admixture of make-Berger , asian Dr. Fixit or equivalent complete all as specified and directed.
M&L for roof treatment applying PU & Acrylic based Elostomeric Coat in UV shafe having OVOC coating apply two coats as per manufacturer's instructions to protect roof over clean plastered surface complete all as specified & directed by Engr-in-charge. Note :- (i) Water proofing gurantee & Security Amount shall be as specified in para 27.5 on page 111 of CA.
Demolition of RCC of any descrition and in any position not other wise specially provided for complete all as specified and directed by Engineer in Charge (reinforcement cut as required to facilitate demolition)
M&L for RCC 1:2:4 type B-1 using (20mm graded stone agg) for chajjas, crumple etc complete all as specified and directed
M&L for gunniting to RCC works in column beams, slabs, chajja, facia, landing, balconies etc by removing/ dismantling of RCC (loose concrete) and cutting of steel bar including plaster cleaning of surfaces with wire brushes and applying epoxy, paint anti corrosive coating of minimum 40-50 microns thick with sikatop Armatec 108 or Colusal VL of MC Bauchemie to rusted steel reinforcement after removing cleaning all rust and supply and fixing welded steel wire mesh 75mm x75mm with 4mm dia steel wire as facies/drops and similar works etc and expoxy based or other equivalent suitable bonding against treatment to be carried out on old concrete surface with Sikadur 32 of Sikka. Nito bond EP of fosroc or equivalent (as per manufacturers instruction) to bond old and new concrete mixing @ 2% by weight of cement polycrete and providing gunniting with a minimum pressure of 2 to 2.5 Kg sqcm and applying 35mm thick gunniting in cement mortar (1:2) (one part of cement and two part of ghaghar sand) using ordinary port land cement of 43 grade over wherever required, complete all as specified and directed by Engineer-in-Charge. Note:-(i) After placing the additional reinforcement all concrete surface shall be thoroughly scrubbing with. (ii) Additional reinforced TMT bars where incorporated in work and including 20mm thick cement plaster in 1:4 (iii) Work to be carried out as in patches as directed by Engr-in-charge. (iv) Rate for steel scaffolding upto 10m height as directed to be included in quoted rate. (v) All demolished material removed from MoD land completely. (vi) All loose concrete fallen on floor while gunniting to be cleaned & removed from site to outside MoD land.
M&L for mild steel TMT bars 10mm dia and over cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips
M&L TMT steel bars 6mm to 8mm dia and over cut to length bent shape required, including cranking bending binding with mild steel wire (annealed) not less than 0.9mm dia quality conforming to relevant IS complete all as specified.
Demolition of brick work, built in cement mortar or cement lime mortar including all quoins, pillars etc. and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 50m as directed by the Engineer-in-Charge
M&L for brick with fly ash brick old size straight of curved on plan exc 6 m mean radius built in CM 1:6 complete all as specified and as directed.
Taking down cement Plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc., including removal of debris, complete all as specified and as directed
Rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M & L for rendering 10 mm thick on surfaces of ceiling in cement mortar (1:3) and finished even and smooth without using extra cement complete all as specified and as directed.
Material & labour for preparation of new undecorated plastered surfaces of ceiling and applying three coats of white wash etc complete all as specified and as directed
M & L preparation of newly plastered or previously untreated wall surfaces and applying two coats of oil bound distemer over 2 to 3mm thick cement based wall putty complete all as specified and as directed.
E/M Portion
M&L for submain wiring with in replacement 2 single core PVC insulated FRLS cable 4 Sqmm copper conductor PVC sheathed in and including rigid PVC concealed conduit heavy duty of suitable size incl cutting chiseling of wall and making good to disturbed surface of walls / floor etc with plastering painting etc so as to match with the existing finishes, drawn with 4 Sqmm PVC insulated FRLS copper conductor cable for earth wire fixed with shaddle and connecting to common earth teriminals complete all as specified.
Supply and fixing single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp 240 volts.
Electric storage water heater (vertical type) 25 litres, with porcelain enamel glass lined inner tank 230 V, AC, Single phase, IS 2082 certified, 4/5 Star rating, with 15mm brass non return valve and including connecting fastners not less than 100 mm with suitable nut, bolt & washers grouted in walls with complete masonry work for proper mounting of Geyser fastning bolts etc as directed as site reqmt and making necessary inlet and outlet water & electric connection tested on load including provision of 15 Amp plug top and PVC insulated & PVC sheathed copper conductor cable 4 sqmm 3 core upto 15 Amp plug point and inlet and outlet copper connection complete all as specified and directed. Make: Havells Monza DX product code GHWAMFSWH025 or equivalent in Bajaj / Crompton Greaves Note :- Water connection and point wiring for electric connection shall be measured and paid for separately.
Supply & Fixing GI pipe 15 mm bore medium grade incl all aceesories fixing with wall/ floor/ceilings
M & L for cutting and screwing existing steel tubing 15 mm dia bore size for alterations / additions required for connection with geyser complete all as directed.
M & L for cutting hole not exceeding 150 sqcm into through brick wall built in cement mortar or stone wall / RCC wall built in lime mortar / concrete for inlet pipe of geyser in parabit wall / site reqmt making good the disturbed surfaces complete all as directed.
S & F PVC connection 15 mm size with PTMT nuts 450 mm long hot/cold complete all as directed.
S & F stop valve 15 mm bore heavy duty fancy type chromium plate with long sunk and cup connected in wall clamps as per site reqmt complete all as directed.
Bid tap, heavy duty, chromium plated, fancy type, with crutch or butterfly handle scrwed down, screwed for iron pipe or for brass ferrule of 15 mm bore and fixed complete all as specified & directed.
M&L point wiring using approved colour coding as per IS with stranded copper conductor single core 1.5 Sqmm (Nominal area), PVC insulated cable in and incl PVC conduit (ISI marked) including cutting chiseling and grouting concealed PVC conduit pipe, tee, elbow and bend etc.and with all connecting accessories incl mild steel sunken boxes suitable for mounting switch/sockets with earth dolly duly painted with two coats of anti corrosive paint over a coat of red oxide primer incl mounting frame over cover plate, covered with 3mm thick plastic laminated sheet, incl PVC insulated copper conductor 1.5 Sqmm (Nominal area) single core PVC cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified. Note : Switch/sockets shall be measured and paid for separately (a) One light/fan point controlled by one switch
S&F switch piano type 6 Amp, SP flush type complete all as specified and as directed by Engineer-in-Charge.
S&F ceiling rose, 3 phase/PVC/polycorbonate isolate body complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing exhaust fan 300mm sweep sp 240 volts incl Cuting of wall for fixing exhaust fan and making good disturbed surface complete all as specified and as directed by Engineer-in-Charge.
S&F sheet metal enclosure with double door for DBs conforms to IS:8623.III , IP:43 protection, shrouded neutral bar and cement spill protector, 8 way, 240 Volt SPN
S & F MCBs 'B' characteristics, Double pole , 240 V, 40 Amp breaking capacity 10 kA 230 volts, single pole complete all as specified and as directed by Engineer-in-Charge.
S & F MCBs 'B' characterstic single pole 5 to 30 Amp, 240 volt breaking capacity 10 kA
Supply, laying, jointing and testing of XLPE insulated, armoured, heavy duty LT cable 1100 Volts grade with aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area 10 Sqmm 4 core, complete, all as specified and directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 metre deep and not exceeding 1.5 metre wide and getting out including dressing / trimming sides and leveling/grading and ramming of bottom of excavation complete as sepecified and directed by Engr-in-Charge.
Returning, filling in including spreading, leveling, watering and well raming excavated soid in layers not exceeding 25 cm thick, filling back in trenches after cables have been laid and tested, poles, stays, struts have been erected and tested complete as sepecified and directed by Engr-in-Charge.
Removing of surplus soil to a distance n.exc 50 mtr and depositing at a level n.nexc 1.5 mtr above starting point where directed complete as sepecified and directed by Engr-in-Charge.
M&L for sand cushioning in trenches for protection of LT under ground cable including punning and consolidation complete as sepecified and directed by Engr-in-Charge.
Supply and Laying Bricks old size sub class 'B', of class designation 10, for the protection of cable laid flat dry across the cable complete as sepecified and directed by Engr-in-Charge..
GI Tubes, light grade, 40 mm dia with all fittings laid in trenches or fixed on walls etc complete all as specified and as directed by Engineer-in-Charge.
M&L complete for drilling hole under hard standing /road in different location as per site requirement (between 03 mtr to 12mtr maximum) for laying of pipe for protection of cable etc by means of mannual bookle and without disturbing the top surface and making good the disturbed surface if any complete all as specified.
Supply & fix MCB SPN 8 Way Single door sheet metal enclosures for DB's when MCBs to be used all as specified and directed
M&L sub main wiring with multistranded FR copper conductor cable PVC sheathed in and including concealed suitable size PVC conduit medium grade with fittings and two runs of 10 Sqmm and one run of 10 Sqmm FR copper conductor as earth wire and connected to earth dolly suitable for mounting modular switches including modular metal flush boxes and modular face plate complete all as specified and as directed by Engr-in-charge, (The works includes cutting of chasis and making good disturbed surfaces alongwith finishing the suface with matching the existing paint coat all this work should included in the rate deemed to included in quated rate).
Supply and fixing 415V 10KA 'B' curve miniature circuit breaker (MCB) of TPN 32 Amp current carrying capacity in the DB complete with connection testing and commissioning.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SPN 16 Amp current carrying capacity in the MCB DB complete with connection testing and commissioning.
Earthing complete with and including galvanised steel earth plate electrode 60 cmx 60cm x 6 mm thick surrounded by mixture of charcoal and salt in alternate layers , buried directly in ground vertically in a pit of depth not less than 2.25 meter deep below ground level with top as of the plate at a depth of not less than 1.5 mtrs below normal ground level connected to galvanized iron or steel earth lead wire 4.0 mm dia,( NO 8 SWG) by means of bolts ,nuts, check nuts and washers of galvanised iron or steel earth wire protected by galvanised steel pipe 15 mm bore (light grade) and connected to main switch or main control board all as shown in electrical plate No. 3 of SSR - 2009(Pt I) & including necessary excavation and earth work. Note:- The rate also include charcoal and salt in alternate layers, 20 mm bore GI pipe (Light grade ) for watering , protection pipe funnel, wire mesh , PCC 1:2:4 type B1 chamber in cement concrete ,50 mm thick precast RCC M-25 ( Normal mix) cover duly reinforced with XPM (weight not less than 3 kg /sqm ) and CI frame etc , and including provision of test point , connecting to test point and testing on completion etc, complete all as specified. NOTE : The unit rate include earthing lead and protection pipe upto 7.5 metre from top of earth plate.
Supply, installation, commissioning and testing for 6 KVA, 5 Star Online UPS with Single phase input volatge 110V to 300V and output voltage 230 +/- 1% system with battery backup time 30-40 min which Battery interlinks UPS to battery cable, 2 years warranty of UPS with following specifications: 1.Unity Power Factor Output With 20-Battery Option,. 2.High Efficiency up to 94% & True Double-Conversion. 3.DSP technology guarantees High Performance. 4.Wide Input Voltage Range (110-300 VAC) & Light Weight UPS 5.Active Input Power Factor Correction 0.99 6.50Hz/60Hz Frequency Converter Mode & Emergency Power off Function (EPO). 7.ECO mode for Energy Saving & Adjustable Battery Numbers 8.SNMP/USB/RS-232 Communications & Maintenance Bypass. 9.Static Bypass Available & Optional N+X Parallel Redundancy. 10.Generator Compatible & Inbuilt Surge Protection with OVCD Available. 11. Battery Requirement 12V 26 AH Sealed batteries of standard make with 26 in numbers of quantity 12. Battery Rack and Connector complete all as specified and directed by Engineer in charge.
S&F sheet metal enclosure with double door for DBs conforms to IS:8623.III, IP:43 protection, shrouded neutral bar and cement spill protector, 12 way, 240 Volt SPN Make : Legrand /Siemens /Havells
S & F MCBs 'B' characteristics, Double pole , 240 V, 40 Amp breaking capacity 10 kA 230 volts, single pole complete all as specified and as directed by Engineer-in-Charge. (Make:Legrand / Schneider/Havells)
S & F MCBs 'B' characterstic single pole 5 to 30 Amp, 240 volt breaking capacity 10 kA (Make : Legrand / Havells/Schneider)
Supply and fixing single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp 240 volts.
M&L for submain wiring with in replacement 2 single core PVC insulated FRLS cable 10 Sqmm copper conductor PVC sheathed in and including rigid PVC concealed conduit heavy duty of suitable size incl cutting chiseling of wall and making good to disturbed surface of walls / floor etc with plastering painting etc so as to match with the existing finishes, drawn with 10 Sqmm PVC insulated FRLS copper conductor cable for earth wire fixed with shaddle and connecting to common earth teriminals complete all as specified. (Make of cable :- Finolex/ Polycab/ Havells )
Taking out and shifting of existing earthing system with all accessories including copper/GI strip of any size /any position and material and labour for making new hole of 150 mm dia upto 3.0 mtr depth. Supply and filling in NABL certified bag compound(0.001ohms mtr conductive grounding granuals 2x 25 Kg Each pits ) as per relevent IS and achieving the desired earth result complete all as specified and directed by Engineer-in Charge . (Each earth pit shall include minimum 50 Kg (two bags of 25 Kg each) NABL Lab Certified Agreegate and Cement 12.5 Kgs for filling bore holes with water mixed in 2:1 ratio (two part of compound and one parts of cement), so as to achieve earth resistance below 1 Ohm all as specified and as directed by Engineer-in-Charge ) Note: 1.Work will be done with satisfaction of users with result of 01 Ohm and below. 2. If value is not found below 01 Ohm the earthing will be done again . No extra claim will be admissible to the contractor on this account.
M&L galvanised in replacement iron strip 32 x 6 mm burried in ground or fixed on wall upto test point.complete all as specified and directed by Engineer-in-charge.
M&L for making PCC block of size 25 X 25 X 25 cm in CM 1:2:4 Type B1set in cm 1:4 with 20 mm graded stone for arresting GI pipe post on the roof top of the building complete, etc. all as specified and directed by Engineer-in-charge.
M&L in replacement for making stand post (1m) each made out of GI pipe 50 mm dia medium grade for fixing on the roof top at the building etc. complete all as specified and directed by Engineer-in-charge
Dismantling and taking up existing serviceable air termination single pointed made of any material complete all as specified and as directed by Engr in charge.
S&F a single pointed air termination aluminium rod 1500 mm long 20 mm dia of superior quality of the rod for fixing on stand post on the rooftop of the building etc. complete all as specified and directed.
Dismantling and taking up old existing unserviceable Test Point Terminal Block made of any material complete all as specified and as directed by Engr in charge.
M&L test point terminal block made of gun metal or phosphorus bronze size ( 75 x 75 x 25 ) mm drilled and screwed including three nos 8mm dia 25 mm long hex. Head screw complete all as specified and directed by Engr-in-Charge.
Supply only porcelin viterous white/ brown/ green insulators of sizes 25mm x 25mm having provision of two holes for fixing on roof / wall under strip/ channel on top for running of down conductors to maintain gap between wall and down conductors etc complete all as specified and directed by Engr-in-Charge.
M&L in replacement for earth continuity conductor or main earthing lead fixed to Floor/wall / roof/Air termination and connecting Machinery to test point with 25x4 mm aluminium strip including taking down existing aluminium/GI strip complete all as specified and directed by Engr-in-Charge . Note :- (i) Laying / fixing of strip from air termination to test point shall be in one run i.e. there shall be no joint in between air termination. In case joint is required, it shall be jointed with nut & bolt joint with breezing full contact of strip. ii) Strip shall be fixed on insulator at the interval not more than 900mm in such a manner at any place it shall not touch to wall/ roof / any metalic body and also include brazing. (Cost of insulator shall be measured and paid seprately under respective items of Sch of works as supply only)
M&L in replacement for fixing of GI pipe 40mm dia medium grade laid in trenchless acd cover the strips all as specified and directed by Engineer-in-charge
Note:- The amount of Rs 13650/- against Schedule of Credit on Page No 141 shall be deducted from the total amount quoted against Sch 'A' while deriving the Contract Sum for Acceptance
M/S ujjwal associates (BID ID -3156166)
NAVYUG VYAPARI (BID ID -3150600)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .