Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹17.2 LAccepted-AOC | L-1 | Accepted-AOC lowest bidder | |
| 2 | L-2₹17.9 L+₹46,937.50 (2.69%)Rejected-AOC 275 2 AJIT NAGAR UPPER GADIGARH AIRPORT ROAD JAMMU 181101 | JAMMU | JAMMU | JAMMU AND KASHMIR | 181101 | L-2 | Rejected-AOC other than lowest bidder | |
| 3 | L-3₹18.8 L+₹1.4 L (8.19%)Rejected-AOC | L-3 | Rejected-AOC other than lowest bidder | |
| 4 | L-4₹18.9 L+₹1.5 L (8.42%)Rejected-AOC | L-4 | Rejected-AOC other than lowest bidder | |
| 5 | L-5₹19.9 L+₹2.5 L (14.3%)Rejected-AOC | L-5 | Rejected-AOC other than lowest bidder |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
11 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Lt Col Ram G
GE Kaluchak Pin-900673 C/O 56 APO
REPAIR TO ROOF TREATMENT, SUNKEN PORTION, FACIA, BALCONIES AND RAIN WATER PIPE AT BD BARI MIL STN UNDER GE KALUCHAK
2022_MES_551593_1
GE/KC/NIT-37/2022-23
Open Tender
Civil Works
Item Rate
270 days
Kaluchak
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE Kaluchak
₹50,000
Yes
16 Nov 2022
13 Sept 2022
18 Oct 2022
13 Sept 2022
11 Oct 2022
27 Sept 2022
13 Sept 2022 - 20 Sept 2022
Amount
Demolition of reinforced cement concrete of any description in any position not otherwise specifically provided for (Reinforcement cut as required to facilitate demolition), complete all as specified & directed.
Demolition of cement concrete (un-reinforced) of any description in any position not otherwise specifically provided for, complete all as specified & directed.
Taking down cement plaster and decayed concrete of any description, upto triple storey of building from roof projection, chajjas etc and making good the decayed portion with cement mortar 1:3 mixed with integral water proofing compound or PCC 1:2:4 type B-0 using 12.5mm graded crushed stone aggregate including necessary form work/scaffolding where ever required, rendering with 15 mm thick cement mortar 1:3, surface finished even and smooth without using extra cement using liquid water proofing admixture as per manufacturer’s instructions , complete all as specified & directed. Note : Liquid water proofing admixture as per manufacturer’s instructions shall be measured & paid seprately.
Cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3, complete all as specified & directed.
PCC 1:2:4, nominal mix, type B-0, using 12.5mm graded crushed stone aggregate as in roof padding and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified & directed.
Complete removal of the existing roof treatment of any description viz tarfelt or membrance surface of roof tiles/concrete padding etc including grubbing up of tree roots, removing existing water tank of any capacity, refixing at same place after making necessary arrangements, removing all the debris to a distance n exc 100m for roof treatment work, preparation of the concrete roof surfaces by scrubbing down with steel brushes and cleaning with water all loose dirt/dust and applying the following Roof Treatment complete all as specified & directed :- (a) Applying 1st course of 15mm thick screed bed in cement mortar 1:4 over concrete surfaces. (b) Applying 2nd course of bitumenous primer conforming to IS-3384 @ 0.4 Kg/Sqm over the screed bed. (c) Applying 3rd coarse of a coat of blown type bitumen of grade 85/25 heating to a working temperature of 180° C and applied @ 1.2 Kg/Sqm.
(d) Applying 4th course of APP (Atactic Polypropylene) modified polymeric membrane 3 mm thick weight not less than 3.6 Kg/Sqm with 160 Grams/Sqm non woven polyster made at centre core reinforced laid with 75 mm side overlap and 100 mm overlap. The membrane has to be laid with LPG torch and overlap sealed and finished neat. (e) Applying 5th course of a coat of bonding material with blown type bitumen of grade 85/25 heating to a working temperature of 180° C and applied @ 1.2 Kg/Sqm.
Supply only liquid water proofing admixture, complete all as specifed & directed.
75mm thick PCC 1:3:6, nominal mix, type C1, using 20mm graded crushed stone aggregate as in plinth protection, surface finished even and smooth without using extra cement including filling of 6mm thick joints with bitumen mastic filling comprising of one part of heated bitumen 85/25 or 80/100 grade and three part of sand by weight, laid in a stretch not exc 3m and joint at every turning/corners complete all as specified & directed.
Complete removal of the existing sunken treatment including roughening and preparation old surfaces of concrete floor by picking, scurubbing down with steel brushes, sweeping clean and washing down with water to remove dust etc and applying the following treatment :- (a) 15 thick rendering on fair faces of brick work or cement surfaces in cement mortar 1:4 with using integral water proofing compound as per manufacturer instructions by weight of cement to sunken portion including wall of sunken portion with proper slope towards outside and finishing cement concrete or brick work surface even and smooth using extra cement, finishing concrete including walls of sunken portion with proper slope. (b) Applying 2nd course of bitumenous primer conforming to IS-3384 @ 0.4 Kg/Sqm over the screed bed. (c) Applying 3rd coarse of a coat of blown type bitumen of grade 85/25 heating to a working temperature of 180° C and applied @ 1.2 Kg/Sqm.
(d) Applying 4th course of APP (Atactic Polypropylene) modified polymeric membrane 3mm thick weight not less than 3.6 Kilogram/Square Metre with 160 Grams/Square Metre non woven polyster made at centre core reinforced laid with 75 mm side overlap and 100 mm overlap. The membrane has to be laid with LPG torch and overlap sealed and finished neat. (e) Applying 5th course of a coat of bonding material with blown type bitumen of grade 85/25 heating to a working temperature of 180° C and applied @ 1.2 Kilogram/Square Metre. Note : Ponding shall be done in sunken portion area by filling water which shall be kept there for 48 Hours. In case a slightest indication of seepage/leakage is noticed, the same shall be rectifird by grounting the effected area at no extra cost. Thereafter, ponding shall be repeated till there is no indication of seepage/leakage. The arrangements of ponding to be included in quoted rates and nothing shall be admissible on this account.
Vitreous chinaware squatting pan, 'Orissa Pattern' size 580mm x 440mm with integral foot rests, white, with ‘P’ or ‘S’ trap, front or back inlet, including provision of lime concrete, making connections to trap and to flush pipe etc. and making good to floors, fixed in repairs, complete all as specified & directed.
PVC valveless, syphonic action type flushing cistern, 10 litres capacity, plunger type, low level, white with inlet, ball valve, float and handle, 32 mm dia PVC long bend flush pipe 90cm long, fixed in repairs, complete all as specified & directed.
Bib tap, 15mm bore, fancy type, chromium plated, cast copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule, fixed in repairs, complete all as specified & directed.
Stop valves, cast copper alloy, 15mm bore, screwed down, high pressure with crutch or butterfly handle, both ends screwed for iron pipe or for union etc., fixed in repairs, complete all as specifed & directed.
PVC connections 15mm size with PTMT nuts of length 600mm, complete all as specified & directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified & directed.
Non skid ceramic coloured tiles, 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.06 sqm but nexc 0.11 sqm in floor etc set & jointed in neat cement slury & pointed in white or coloured cement mixed with pigment to match over and including 15mm thick screed layer in cement mortar 1:4, taking down door shutter and refixing the shutter at same place after laying of tile, complete all as specified and directed.
Glazed ceramic coloured tiles of size 450mmx300mm, thickness 7mm as in vertical surfaces such as skirting, dado, wall etc., set and jointed in neat cement slurry and pointed with coloured cement to match over and including 10mm thick rendering in cement mortar 1:4, complete all as specified & directed.
Taking up or down steel tubing and connections 15mm bore, complete all as specifed & directed.
Taking up or down steel tubing and connections 20mm bore, complete all as specifed & directed.
Refixing old steel tubing and connections of 15mm bore in new or old position (Walls, ceiling, floors etc.) including cleaning for refixing, complete all as specified and as directed .
Refixing old steel tubing and connections of 20mm bore in new or old position (Walls, ceiling, floors etc.) including cleaning for refixing, complete all as specified and as directed .
Galvanized iron water tubing, medium grade, 15mm bore with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc., fixed complete to walls and ceilings or laid in floors, complete all as specified and directed.
Galvanized iron water tubing, medium grade, 20mm bore with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc., fixed complete to walls and ceilings or laid in floors, complete all as specified and directed.
Demolition of brickwork or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc., but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified & directed.
Brickwork with sub-class ‘B’ bricks (old size), straight or curved on plan exc. 6m in mean radius, built in cement mortar 1:6, complete all as specified & directed.
Brickwork with sub-class ‘B’ bricks (old size), straight or curved on plan exc. 6m in mean radius, built in cement mortar 1:6 but except brick i.e. using serviceable bricks obtained from Srl item No. 24 here-in-before, complete all as specified & directed.
Taking down cement plaster on brick or stone surfaces of wall/ceiling, chajjas, roof projections etc upto triple storey etc. including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified & directed.
15mm thick rendering in cement mortar 1:4 on fair faces of brick surfaces or concrete surfaces, surface finished even and smooth without using extra cement, complete all as specified & directed.
15mm thick rendering in cement mortar 1:6 on fair faces of brick surfaces or concrete surfaces, surface finished even and smooth without using extra cement, complete all as specified & directed.
10mm thick rendering in cement mortar 1:3 on concrete surfaces of chajjas, upward fascias, ceiling and similar items, surface finished even and smooth without using extra cement, complete all as specified & directed.
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc., and hoisting if required reconnecting and re-fixing in position, exc. 250 & n. exc. 500 ltr, complete all as specified & directed.
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc., and hoisting if required reconnecting and re-fixing in position, exc. 500 & n. exc. 1000 ltr, complete all as specified & directed.
Dismantling of PVC water storage tanks of capacity exc 250 litres but n exc 500 litres, complete all as specified & directed.
Rotationally moulded polyethylene water storage tank (cylindrical vertical with closed top), triple layered, hoisted & fixed in position of capacity 500 ltrs including making necessary arrangements for fixing of inlet, outlet, over flow pipe, wash out pipe etc, complete all as specified & directed.
Dismantling of PVC water storage tanks of capacity exc 500 litres but n exc 1000 litres, complete all as specified & directed.
Rotationally moulded polyethylene water storage tank (cylindrical vertical with closed top), triple layered, hoisted & fixed in position of capacity 1000 ltrs including making necessary arrangements for fixing of inlet, outlet, over flow pipe, wash out pipe etc, complete all as specified & directed.
Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule for bore of pipe 20mm, fixed in repairs, complete all as specified & directed.
Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule for bore of pipe 25mm, fixed in repairs, complete all as specified & directed.
Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for bore of pipe 20mm, fixed in repairs, complete all as specified & directed.
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar of any bore, complete all as specifed & directed.
PVC (SWR) pipes, 110mm bore, single socketed, in any length with rubber ring joints, fixed to walls with clamps, complete all as specified & directed.
110mm bore PVC (SWR) bends any radius with oval access door, complete all as specified & directed.
PVC (SWR) junction single (Single T) equal or unequal, 110mm bore, complete all as specified & directed.
PVC (SWR) vent cowl of size 110mm bore, complete all as specified & directed.
Preparation of new plastered surfaces of wall and applying two coats of oil emulsion distemper over a coat of chalk whitening, complete all as specified.
Preparation of new plastered or concrete surfaces of walls and applying two coats of cement base paint over a coat of cement primer, complete all as specified & directed.
Preparation of new plastered surfaces of ceiling and applying three coats of white wash, complete all as specified & directed.
Preparation of old decorated plastered or unplastered surfaces of walls by brooming down or by steel wire brushes, scraping down smoke spots, moulds, moss and efflorescent salts, trading oil, greasy spots etc. and applying one coat of cement base paint, complete all as specified & directed.
Preparation of old decorated plastered or unplastered surfaces of walls by brooming down or by steel wire brushes, scraping down smoke spots, moulds, moss and efflorescent salts, trading oil, greasy spots etc. and applying one coat of oil emulsion distemper, complete all as specified & directed.
Preparation of old decorated plastered or unplastered surfaces of walls by brooming down or by steel wire brushes, scraping down smoke spots, moulds, moss and efflorescent salts, trading oil, greasy spots etc. and applying one coat of white wash, complete all as specified & directed.
GENESIS INDIA
M/S Vishwakarma Builders
KAMAL CONSTRUCTION
M/s K.S. Constructions
M/s Anand Prakash
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .