Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.3 LAccepted-AOC 24A RABINDRA SARANI KOLKATA 700 073 | KOLKATA | KOLKATA | WEST BENGAL | 700073 | L1 | Accepted-AOC lowest bidder | |
| 2 | L2₹6.6 L+₹29,535 (4.72%)Rejected-Finance | L2 | Rejected-Finance Biddder is not L1 | |
| 3 | L3₹6.6 L+₹35,562.50 (5.68%)Rejected-Finance 210 A RASHBEHARI AVENUE KOLKATA 700029 | KOLKATA | KOLKATA | WEST BENGAL | 700029 | L3 | Rejected-Finance biddder is not L1 |
Tender Value
Refer Docs
EMD Value
₹12,876
Closing Date
18 Dec 2024, 2:00 pmClosed
Executive Engineer-I,CKHED,PWDte.
Central Kolkata Health Electrical Division, P.W.Dte. P-5, CIT Road, 2nd Floor, Moulali, Kolkata
Repair and Renovation of Electrical Installation work of patient party night shelter Ground Floor located at the northern block (Opposite Gynae building)at CNMCH for the establishment of department of Emergency Medicine.
2024_WBPWD_772587_1
WBPWD/EE-I/CKHED/eNIT-82/24-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
15 days
CNMCH for the establishment of department of Emerg
Please refer Tender documents.
3 documents required · 3 mandatory
₹12,876
Central Kolkata Health Electrical Division
11 Apr 2025
22 Nov 2024
20 Dec 2024
22 Nov 2024
18 Dec 2024
26 Nov 2024
26 Nov 2024
Amount
Supplying only the following 1.1 KV grade PVC insulated A/Al. Cable as below: [KEI/RR/Havells/Polycab] 4 core 240 sq mm.
Laying of one cable above 150 sqmm and upto 300 sqmm through existing covered masonry trench incl. taking out RC covers, after carefully taking out the RC covers, clear the path by removing sand, clay, or any debris to facilitate the smooth laying of the cable. Once the cable installation is completed, systematically set the RC covers in order and mending good damages to the original finished as per direction of EIC.
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required
40 mm dia
S & F compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below: 4 core 240 sq mm. [F4:7d]
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials. 4 core 240 sq mm.
Supplying and fixing 415V,315A, TPN SFU open execution in existing SS enclosure/cubical with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. (Make:l&T)
Supplying and fixing 415V,250A, TPN SFU open execution in existing SS enclosure/cubical with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. (Make:l&T)
Fixing only 250/315Amp open execution type main switch set in existing substation LT Panel Chamber (welding ,if required) and necessary connection as required from existing Bus-Bar Chamber to main switch to Cable alley with suitable size & length of heavy copper bar with necy. FRP Insulation with Necy. sockettings required as per site condition & diretion of EIC.
supply, installation, testing, and commissioning of an indoor-type LT Panel box, designed for IP-43 protection, rated at 415V, 415A BBC, 50Hz. The panel construction will utilize 2mm thick CRCA steel/MS plate sheets reinforced on a 75X50X6mm angle iron frame, featuring front and rear openable hinged doors with door handle arrangements, including a locking arrangement.
The foundation for the panel will be constructed using cement concrete, ensuring a robust and approved structure. This foundation will be site-specific and will incorporate proper sizing of iron channels and angles to enhance stability and compliance with the EIC requirements. Additionally, the foundation, having a suitable size for the installation of the above-mentioned panel, is included in the scope of work. The panel will be securely mounted either in the floor or on the wall, as per the site requirements and in accordance with the EIC specifications. This mounting arrangement ensures optimal stability and accessibility for the efficient operation and maintenance of the LT Panel.
The LT Panel box will include interconnections between 415V Four Pole SFUs. Heavy copper solid bars with necessary socketing will support the bus-bars, and FRP/DMC insulators will be used for insulation.Inside the panel, the interconnection between the main bus bar and all SFUs and Changeovers will be established using appropriate size copper bars and suitable spreader links. Wire connections are not permissible for this purpose. To further enhance the reliability and efficiency of the panel, suitable size copper bars and spreader links will be provided for the outgoing terminals of all SFUs and Changeovers. This design feature aims to facilitate the connection of outgoing cable terminals, ensuring a robust and seamless electrical distribution system.Panel drawing detailling with busbar and interconnection cu strip arrangemant with cable entry and foundation details must be approved by EIC.
The panel dimensions will comply with the respective Bureau of Indian Standards (BIS) and site working space requirements. It will be painted powder coating with two coats of red oxide as a primer, followed by a final coat with synthetic light grey /Siemens grey shade as per IS 631.
A) Incoming: (i) 415V, 315 Amp TPN Cubical type Switch Disconnector Fuse Unit suitable for DIN Fuse-link. – 2No. (ii) 415V,415 Amp BUS-BAR of (4x50x5mm) [Elecrtrolyte copper Bar on heavy duty porcelain insulator with heat shrinkable coloured sleeves and i/c DMC/SMC bus bars supports at required intervals complete as required. multi-color tapping & necy drilled holes.-1 Set. (iii) 415V, 320A FP on load operated Changeover switch [L&T]-1No. B) Outgoing: (i) 415V, 63 Amp TPN Cubical type Switch Disconnector Fuse Unit suitable for DIN Fuse-link. (L&T) – 2No (One for Lift & one for New Substn TPNDB) (i) 415V, 160 Amp TPN Cubical type Switch Disconnector Fuse Unit suitable for DIN Fuse-link. (L&T) – 2No (One for Bldg VTPNDB another for X-Ray Centre) (ii) 415V, 250 Amp TPN Cubical type Switch Disconnector Fuse Unit suitable for DIN Fuse-link. (L&T) –2No. (One for MRI Centre and other as Spare)
D) Miscellaneous: (1) S&F Danger board of size 1'x1' on the front face of LT Panel - - - 1 No. (2) All switches(SFU etc.) required, shall be fixed by S.S. nuts & bolts on angle/flat iron frame base as per requirement & direction of E.I.C (3) All separate compartments for SFUs etc. must be marked with Name Plates (replaceble type,because we can change the nameplate as required), according to their Outgoing or Incoming connections, as per direction of E.I.This labeling practice ensures clear identification of where each component is intended to be placed within the electrical system. (4) There must be cable entry box of appropriate size and of same material & guage as that of the main panel, at up-side & down-side of the panel. (5) Control circuit to be protected by MCB and control wiring to by 1.5 sq. mm.(min.) copper wire. (6) Panel Board must have indication lamps forR-Y-B indication. (7) Panel must have provision for cable entry (for Incomer and Outgoing cable).
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. Long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. Long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. Long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. Below the ground level as below: a) By ISI-Medium GI pipe.
Excavation of soil for installation of Earth Electrode and filling & ramming.For Morrum Soil. [G1:1b]
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 50 mm x 6 mm on wall having clearance of 6 mm from wall incl. providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required [G2:4c]
Connecting the equipments body to earth busbar incl. S&F galvanised (Hot Dip) following sizes MS flat(TATA/ JINDAL/ JSW) on wall/ floorwith GI saddles as required and connection to equipments incl.drilling holes, with bolts, nuts, washers etc. 40 mm x 6 mm galvanised (Hot Dip) MS flat . [G3:4b]
Supply & delivery of 450mm,(18''),rpm-1420,230volt,85Watt wall bracket Fan[EPC Make] comprising with 4nos blade, metal body, heavy duty fan complete with all accessories..
Fixing the wall bracket fan into the wall by fastnuts,screws etc as per direction of EIC.
ConnectingtheequipmentstoearthbusbarincludingS&FGI (HotDip)wireofsizeasbelowonwall/floorwithstaplesburie inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages
No. 10 SWG
Rate should be quoted incl. of all taxes and cess.
Defect Liability period : 1 year
ELECTRO MECHANICAL CORPORATION (BID ID -5847989)
OVERSEAS TRADING AND SUPPLIES CORPORATION (BID ID -5847895)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .