Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.0 LAccepted-AOC AT MAIN ROAD PHUSRO DIST BOKARO PIN 829144 JHARKHAND | BOKARO | JHARKHAND | 829144 | L1 | Accepted-AOC Techno commercially qualified | |
| 2 | L2₹5.1 L+₹13,358 (2.68%)Rejected-Finance AT KARGALI BAZAR PO BERMO DIST BOKARO PIN 829104 | BERMO | BOKARO | JHARKHAND | 829104 | L2 | Rejected-Finance Techno commercially not qualified | |
| 3 | Rejected-Technical AT PO PICHHARI DIST BOKARO | - | Rejected-Technical Techno commericaly not qualified |
Tender Value
Refer Docs
EMD Value
₹5,800
Closing Date
27 Feb 2025, 12:00 pmClosed
MADHU RANJAN KUMAR,PE(EnM),SDOCM
OFFICE OF THE PROJECT OFFICER,SDOCM,DHORI AREA,CCL
(A) Repairing and Rewiring of 8 nos. MQ-type Qtrs., Qtr. no. MQ-56, MQ-55, MQ-54, MQ-37, MQ-38, MQ-45, MQ-46 and MQ-58 occupied by the employees of CCL situated at Karipani pani tank colony (B) Repairing of electrical wiring/re-wiring and changing of
2025_CCL_329235_2
SDOCM/PE(EnM)/e.NIT/24-25/22 dt.15.02.2025
Open Tender
Electrical and Maintenance Works
Item Wise
20 days
SDOCM
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,800
17 Apr 2025
15 Feb 2025
28 Feb 2025
17 Feb 2025
27 Feb 2025
17 Feb 2025
17 Feb 2025 - 20 Feb 2025
Amount
(A) Repairing & Rewiring of 8 nos. MQ-type Qtrs., Qtr. no. MQ-56, MQ-55, MQ-54, MQ-37, MQ-38, MQ-45, MQ-46 & MQ-58 occupied by the employees of CCL situated at Karipani pani tank colony (RATE NOT FILLING)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with1.5sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required Group A (a) Bulb point-68 (b) Tube point-16 (c) Fan point-16
Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc as required. (But without MCB/RCCB/Isolator)2 way single door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required Single pole & natural
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required 32 Amp TP&N
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.2 x 2.5 sq. mm
Providing and fixing of GI wire alongwith service wire
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required
Supplying and fixing brass batten/ angle holder including connection etc. as required
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
(B) Repairing of electrical wiring/re-wiring and changing of different components such as service wire switches socket main switch and lighting finial at sadafal Bal Mandir School at Sharda colony.(RATE NOT FILLING0
Wiring for light point/ fan point/ exhaust fan point/ call bell point with1.5sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.Group A (a) Bulb point-40 Nos (b) Fan point-08 Nos (c) Tube light point-12 Nos (d) call bell point-01 No (e) Exhaust point-02 Nos
Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc as required. (But without MCB/RCCB/Isolator)6 way , Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required Single pole and neutral
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required 32 Amp TP&N
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 2 x 4 sq. mm
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Supply of LED tube light 18 watt
Fitting & fixing of LED tube light 18 wat
Supply and fixing of wooden board/PVC board
Total impact of GST for the purpose of CTC
M/S A N TRADERS (BID ID -1129460)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .