Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.6 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹34.3 L+₹1.7 L (5.33%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹35.0 L+₹2.4 L (7.33%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹35.6 L+₹3.0 L (9.20%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹35.7 L+₹3.1 L (9.61%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
9 Oct 2023, 6:00 pmClosed
GE (AF) Jorhat
GE (AF) Jorhat
REPAIR/REPLACEMENT GI/CI/PPR PIPE LINE ALONGWITH CONNECTED ITEMS FOR PUMP HOUSES AND ALLIED WORKS DOMESTIC AREA AND TECHNICAL AREA AT AFS UNDER GE(AF) JORHAT
2023_MES_619484_1
8570/E8
Open Tender
Civil Works - Water Works
Item Rate
180 days
GE (AF) Jorhat
Please refer Tender documents
9 documents required · 9 mandatory
₹500
GE (AF) Jorhat
₹60,000
Yes
7 Nov 2023
19 Sept 2023
11 Oct 2023
19 Sept 2023
9 Oct 2023
3 Oct 2023
Amount
Excavation in trenches n. exc. 1.5m wide and n. exc. 1.5m deep for taking out/laying CI/GI/DI/UPVC pipe line as in soft/loose soil complete all as specified and as directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers n. exc. 25cm thick layers complete all as specified and as directed.
Removal of excavated material n .exc. 50m distance and depositing where directed at a level n. exc. 1.5m above from starting point complete all as specified and as directed.
M&L for horizontal boring below pavement/road in soft/loose soil for crossing 40mm to 150mm size of CI/GI/DI/UPVC pipe lines complete all as specified and as directed.
Taking out CI pipe lines (including all fittings) from trenches of the following sizes with spigot & socket ends with burnning of lead joints, etc. including taking out lead from joints complete all as specified and as directed. NOTE : Earth work shall be measured and paid separately under relevant item here-in-above.
150mm bore CI pipe
100mm bore CI pipe
80mm bore CI pipe
M&L for CI pipe, Class K7 with spigot & socket end, suitable for run lead joints, laid in trenches including testing after laid complete all as specified and as directed.
150mm bore CI pipe
100mm bore CI pipe
80mm bore CI pipe
M&L for CI fitting of spigot & socket pipe such as bends (any type, radius and angle) tapers any type (straight, bend, increasing, decreasing or double socket, etc.) Tee pieces single branch, ’Y’ junction, double branch, cross collors tail pieces with one end flanged and other end socketed (integrally cast), caps and plugs of dia upto 150mm complete all as specified and as directed.
M&L for run lead joint suitable for CI pipes of the following sizes and fittings including jointing material such as lead, spun yarn, etc. complete all as specified and directed.
150mm bore CI pipe
100mm bore CI pipe
80mm bore CI pipe
M&L for rubber gasket joint suitable for DI pipes of the following sizes and fittings including jointing material such as lead, spun yarn, etc. complete all as specified and as directed.
150mm bore DI pipe
100mm bore DI pipe
80mm bore DI pipe
M&L for brick masonry valve pit of internal size 120x120x120cm suitable for 150mm bore sluice valves with plain cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) for foundation, 23cm thick brick work in cement mortar (1:6), 15mm thick plastering in cement mortar (1:4), 100mm thick coping in PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) including MS sheet cover of thickness 3.15mm fixed over 50x50x6mm angle iron framework including two coats of synthetic enamel paint over one coat of red oxide primer on steel surfaces and making provision of locking arrangement including demolition of old existing valve pit and including necessary excavation and earth work complete all as specified and as directed.
M&L for repairing to existing CI pipe line leakage of the following sizes by caulking of exposed lead as required including pumping out water from pit/trenches complete all as specified and as directed:-
150mm bore
100mm bore
80mm bore
Taking out old existing GI pipe from trenches/floor including connected fittings/accessories (defective gate valve/stop valves) etc. complete of the following sizes for re-fixing/replacing with necessary fittings and valves, etc. complete all as specified and as directed.
GI pipe of 100mm bore
GI pipe of 80mm bore
GI pipe of 50mm bore
GI pipe of 40mm bore
GI pipe of 25mm bore
GI pipe of 20mm bore
GI pipe of 15mm bore
Supply and laying galvanised iron pipes of medium grade ISI marked with all fittings (such as bend, elbows, tees, short pieces of medium grade, connectors, back nuts, caps , plugs and unions etc.) laid in trenches/floor/ducts and also cutting pipes, screwing and for making forged bends on piping as required complete all as specified and as directed of the following sizes:-
GI pipe of 100mm bore
GI pipe of 80mm bore
GI pipe of 50mm bore
GI pipe of 40mm bore
GI pipe of 25mm bore
GI pipe of 20mm bore
GI pipe of 15mm bore
Supply and laying for 20mm dia UPVC pipes of pressure rating 10 KGA/Sq.cm with all fittings (such as bend, elbows, tees, short pieces, connectors, back nuts, caps, plugs and unions, etc.) laying on floor/ducts and also cutting pipes, screwing and for making bends on piping as required after and including taking down old existing pipe complete all as specified and as directed.
All as per Serial item No. 14 here-in-before but 25mm dia UPVC pipes of pressure rating 10 KGA/Sqcm
S&F as in repairs gun metal gate valve (ISI marked) with iron wheel head, screwed both ends for iron pipe with union including taking down/out old existing unserviceable gate valves of the following sizes complete all as specified and as directed:-
Gate valve 50mm bore.
Gate valve 40mm bore.
Gate valve 25mm bore.
Gate valve 20mm bore.
Gate valve 15mm bore.
S&F as in repairs of 150mm bore cast iron sluice valve Class PN-1.6 with flanged ends (ISI marked) complete with stainless steel spindle and cast iron cap including rubber/fiber board gasket, nuts, washers, including taking down old/unserviceable one all as specified and as directed.
All as per Serial item No. 17 here-in-before but 100mm bore CI sluice valve, Class PN-1.6.
All as per Serial item No. 17 here-in-before but 80mm bore CI sluice valve, Class PN-1.6.
S&F as in repairs 100mm nominal dia (ISI marked) butterfly valve complete including rubber/ fiber board gasket, nuts, washers, including taking down old/unserviceable one all as specified and as directed.
All as per Serial item No. 20 here-in-before but 80mm nominal dia (ISI marked) butterfly valve
S&F as in repairs 80mm nominal bore, ISI marked cast iron Non return valve with flanged ends complete including rubber/fiber board gasket, nuts, washers, including taking down old/unserviceable one all as specified and as directed.
All as per Serial item No. 22 here-in-before but 100mm nominal bore cast iron Non return valve.
S&F pressure gauge 0 to 10 kg 4 inch dia including gun metal on/off knob including taking out old existing unserviceable one complete all as specified and as directed.
M&L for brick work with sub class 'B' bricks, straight or curved on plan n. exc. 6m mean radius built in cement mortar (1:4) complete all as specified and as directed.
M&L for 10mm thick rendering in cement mortar (1:4) on fair faces of brick or concrete surfaces on supporting pillar complete all as specified and as directed.
M&L for plain cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete, etc. including use and waste of necessary formwork complete all as specified and as directed.
Demolition of brick or stone/boulder masonry or pipe supporting pillars, kerbs, apron laid in cement mortar complete all as specified and as directed.
Supply only alum ferric (AL2 O3 of 15% to 16% concentration) with water in proportionate way for achieving proper sedimentation of water at all time at pump houses as directed for better sedimentation process at pump houses complete all as specifed and as directed.
Supply only alum crystal of approved quality with water in proportionate way for achieving proper sedimentation of water at all time at pump houses as directed by competent authority for better sedimentation process at pump house complete all as specified and as directed.
Supply only unslaked lime Ca (OH)₂ in poly bag/container of 9 Kg of approved quality with water in proportionate way for achieving proper sedimentation of water at all time at pump houses as directed by competent authority for better purification/sedimentation process at pump house complete all as specified and as directed.
Supply only bleaching powder of approved quality for cleaning/washing the balancing tank, areation tower during decaning/refilling with fresh water at an interval as directed for better cleanleness of balancing tank/areation tower or at other indicated places complete all as specified and as directed.
Supply only Calcium based High strength Chlorination chemical (chlorine contents not less than 65%) with water in proportionate way for maintaining adequate chlorine at all time at Pump Houses as directed by competent authority for water disinfection at pump house complete all as specified and as directed.
Supply and laying 3 layered PPR (Polypropylene Random Copolymer) pipes, ISI marked, PN-16, SDR 7.4 UV stabilised and anti-microbial fusion welded having thermal stability for hot and cold water supply including all PPR plain and brass threaded polypropylene random fittings (such as bends, elbows, tees, short pieces, connectors, back-nuts capps, plugs, unions, etc.) laying in trenches/floors/ducts or fixing to walls, etc. of following sizes including taking down old pipe and fitting also cutting of pipes as required complete all as specified and as directed:-
PPR pipe 160mm outer dia
PPR pipe 90mm outer dia
PPR pipe 63mm outer dia
PPR pipe 32mm outer dia
S&F PPR gate valve (brass insert) of the following dia complete all as specified and directed:-
PPR gate valve of outer dia 63mm
PPR gate valve of outer dia 32mm
PPR gate valve of outer dia 25mm
Taking sample of raw water and tap water from pump houses and getting tested from Directorate of PHED office/Govt authorised Lab for physical/chemical /bacterelogical analysis. Report shall be submitted to Engineer-in-Charge. Note : (i) Water sample will be collected from pump house No. 1, 2, 3, 4, 5, 6, 7, 8, 9, 10 & 11 by the contractor . (ii) No extra cost for testing and transportation shall be paid but quoted rate shall be all inclusive.
M&L for preparation of old painted steel surfaces of exposed pipes laid horizontally at pump houses not exc. 100mm dia by scrapping with mild steel wire brush and sand papering to remove all the loose paint, sludges, rust, etc. and applying one coat of synthetic enamel paint complete all as specified and as directed.. Note : The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender from total amount of Schedule 'A'/BOQ
NIHAR ENTERPRISE
THE SUPPLY AGENCY
M/S D J ENTERPRISE
M/S PAUL CONSTRUCTION
KAY CEE CO. INDIA
M/S BARUAH ELECTRICALS
Bidder Name
KAY CEE CO. INDIA
NIHAR ENTERPRISE
M/S D J ENTERPRISE
THE SUPPLY AGENCY
M/S PAUL CONSTRUCTION
M/S DILIP GOSWAMI
M/S BARUAH ELECTRICALS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .