| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.8 LAccepted-AOC 1227 MODEL TOWN MODEL TOWN BATHINDA BATHINDA PUNJAB 151001 | BATHINDA | PUNJAB | 151001 | L1 | Accepted-AOC M/s Vishal Electric Store being L1 Hence accepted | |
| 2 | L2₹52.5 L+₹5.0 L (10.4%)Rejected-Finance | L2 | Rejected-Finance Quoted other than lowest rate | |
| 3 | Rejected-Technical H NO 18 SHEET NO 5 A KATIA COLONY NAMDEV MARG BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | - | Rejected-Technical Not recommended as the firm is not enlisted in requisite category i.e. b(i) |
| Sl No | Description | Qty | Unit | M/s VISHAL ELECTRIC STORE L1 | AABIA CONSTRUCTION L2 |
|---|---|---|---|---|---|
| 1.00 | M&L for maintenance of Static type NASU make CCR 20 KW including repairing of defective CCRs by identifying the fault, replacement of defective components like PCBs, relay, fuses, LEDs (R,Y,B), replacement of deteriorated complete wiring of CCR, rewinding of transformer etc. with other components and services the same including calibration of CCRs and complete checking, servicing etc as per requirement and painting of CCR Panel inside and out side ones in a contract period done by the contractor and properly scrap out old paint and apply 02 coat of enamel paint after one coat of red oxide paint and write Circuit No./Location, MES No., Capacity, Dt of Install complete all as specified and directed by Engineer-in-Charge.
Note :(a) The above item includes to attend all major or Minor breakdowns and minor spare parts, proper cleaning in & out side for complete period of contract.
(b) Spare parts required will be measured and paid separately under respective item of Sch and Spare parts must be purchased from authories dealership.
(c) All the work under contract must be carried out by AMA/NASU trained service engineers.
(d) Any unexaptable delay in service after site order, penalty will Rs. 5000/- per day recovered from contractor.
(e) Testing of CCR is done in presence of Engineer-in Charge. | 5 | Each Job | 85,000 ₹4,25,000 | 45,000 ₹2,25,000 Lowest |
| 2.00 | M&L for Double Walled Corrugated DWC Pipe orange colour of outer dia 77mm and inner dia 63mm including all fittings like bends, coupler, rubber rings etc complete all as specified and directed by Engineer-in-Charge. | 2,200 | RM | 120 ₹2,64,000 Lowest | 210 ₹4,62,000 |
| 3.00 | Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m. | 8 | Each | 1,500 ₹12,000 Lowest | 4,000 ₹32,000 |
| 4.00 | Supply and fixing of 1x6 Sqmm, 5 kV grade copper conductor PVC insulated polyethylene sheathed, single core, copper tape,double screened Airfield lightening cable laid in treches/inside conduct (GI/PVC) using wire pulling rod or by other means, complete all as specified and directed by Engineer-in-charge.
Make : Rallision/Havells/Equivalent make as approved by Engineer-in-charge | 3,000 | RM | 240 ₹7,20,000 | 235 ₹7,05,000 Lowest |
| 5.00 | Supply and fixing of 1x10 Sqmm, 5 kV grade copper conductor PVC insulated polyethylene sheathed, single core, copper tape, double screened Airfield lightening cable laid in treches/inside conduct (GI/PVC) using wire pulling rod or by other means, complete all as specified and directed by Engineer-in-charge.
Make : Rallision/Havells/Equivalent make as approved by Engineer-in-charge | 3,000 | RM | 300 ₹9,00,000 Lowest | 310 ₹9,30,000 |
| 6.00 | M & L for daily Maintenance of runway lights with the following checks complete all as specified and as directed by Engineer-in-Charge.
(a) Check for unserviceable lamps.
(b) Check for dim Light
(c) Check for broken lens.
(d) Check for CCR Operation
(e) Runway End Lights complete
(f) Runway Edge lights complete
(g) Taxiway Light
(h) H-Landing Light
Note :-
(a) The required items shall be measured and paid separately under appropriate item of Sch.
(b) Cost of transpotation for Electrician and helper from gate to site deemed to be included in rate quoted.
(c) Contractor should employ qualified Technician for liaison with user and daily Report to be signed from user and submit to Engineer-in-Charge. | 330 | Each Job | 500 ₹1,65,000 Lowest | 1,000 ₹3,30,000 |
| 7.00 | Supply only Primary connector with Screen (6 Sqmm) | 40 | Each Set | 500 ₹20,000 | 100 ₹4,000 Lowest |
| 8.00 | Supply only Secondary connector (Male & Female) | 40 | Each Set | 500 ₹20,000 | 200 ₹8,000 Lowest |
| 9.00 | Supply only Isolation transformer 45W,20/6.6Amps or 6.6/6.6 Amps | 20 | Each | 3,000 ₹60,000 Lowest | 3,000 ₹60,000 Lowest |
| 10.00 | Supply only Isolation transformer 200W,20/6.6Amps or 6.6/6.6 Amps | 60 | Each | 4,000 ₹2,40,000 Lowest | 4,000 ₹2,40,000 Lowest |
Tender Value
₹50.0 L
EMD Value
₹99,980
Closing Date
18 Apr 2026, 6:00 pmClosed
Jitender Singh, IDSE
GE (North) Bathinda
COMPREHENSIVE AIRFIELD MAINTENANCE IN AOR OF AGE E/M-V OF GE (NORTH) BATHINDA AT BATHINDA MIL STN
2026_MES_757120_1
8940/NIT-19/25-26/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Bathinda
Class D category b(i)
8 documents required · 8 mandatory
₹500
GE (North) Bathinda
₹99,980
Yes
6 Jul 2026
26 Mar 2026
20 Apr 2026
26 Mar 2026
18 Apr 2026
10 Apr 2026
26 Mar 2026 - 10 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| - | M&L for maintenance of Static type NASU make CCR 20 KW including repairing of defective CCRs by identifying the fault, replacement of defective components like PCBs, relay, fuses, LEDs (R,Y,B), replacement of deteriorated complete wiring of CCR, rewinding of transformer etc. with other components and services the same including calibration of CCRs and complete checking, servicing etc as per requirement and painting of CCR Panel inside and out side ones in a contract period done by the contractor and properly scrap out old paint and apply 02 coat of enamel paint after one coat of red oxide paint and write Circuit No./Location, MES No., Capacity, Dt of Install complete all as specified and directed by Engineer-in-Charge.
Note :(a) The above item includes to attend all major or Minor breakdowns and minor spare parts, proper cleaning in & out side for complete period of contract.
(b) Spare parts required will be measured and paid separately under respective item of Sch and Spare parts must be purchased from authories dealership.
(c) All the work under contract must be carried out by AMA/NASU trained service engineers.
(d) Any unexaptable delay in service after site order, penalty will Rs. 5000/- per day recovered from contractor.
(e) Testing of CCR is done in presence of Engineer-in Charge. | - | Each Job | - | - |
| - | M&L for Double Walled Corrugated DWC Pipe orange colour of outer dia 77mm and inner dia 63mm including all fittings like bends, coupler, rubber rings etc complete all as specified and directed by Engineer-in-Charge. | - | RM | - | - |
| - | Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m. | - | Each | - | - |
| - | Supply and fixing of 1x6 Sqmm, 5 kV grade copper conductor PVC insulated polyethylene sheathed, single core, copper tape,double screened Airfield lightening cable laid in treches/inside conduct (GI/PVC) using wire pulling rod or by other means, complete all as specified and directed by Engineer-in-charge.
Make : Rallision/Havells/Equivalent make as approved by Engineer-in-charge | - | RM | - | - |
| - | Supply and fixing of 1x10 Sqmm, 5 kV grade copper conductor PVC insulated polyethylene sheathed, single core, copper tape, double screened Airfield lightening cable laid in treches/inside conduct (GI/PVC) using wire pulling rod or by other means, complete all as specified and directed by Engineer-in-charge.
Make : Rallision/Havells/Equivalent make as approved by Engineer-in-charge | - | RM | - | - |
| - | M & L for daily Maintenance of runway lights with the following checks complete all as specified and as directed by Engineer-in-Charge.
(a) Check for unserviceable lamps.
(b) Check for dim Light
(c) Check for broken lens.
(d) Check for CCR Operation
(e) Runway End Lights complete
(f) Runway Edge lights complete
(g) Taxiway Light
(h) H-Landing Light
Note :-
(a) The required items shall be measured and paid separately under appropriate item of Sch.
(b) Cost of transpotation for Electrician and helper from gate to site deemed to be included in rate quoted.
(c) Contractor should employ qualified Technician for liaison with user and daily Report to be signed from user and submit to Engineer-in-Charge. | - | Each Job | - | - |
| - | Supply only Primary connector with Screen (6 Sqmm) | - | Each Set | - | - |
| - | Supply only Secondary connector (Male & Female) | - | Each Set | - | - |
| - | Supply only Isolation transformer 45W,20/6.6Amps or 6.6/6.6 Amps | - | Each | - | - |
| - | Supply only Isolation transformer 200W,20/6.6Amps or 6.6/6.6 Amps | - | Each | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.82 MB
tender19.pdf
Tender Documents • 0.92 MB
BOQ_848081.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .