REPAIR/ MAINTENANCE OF HIGH CAPACITY PUMPS (VT AND SUBMERSIBLE) INCLUDING REWINDING OF FAULTY MOTORS, REPLACEMENT OF UNSERVICEABLE CONTACTORS/ STARTERS AND OTHER ALLIED ITEMS UNDER AGE E/M (WS) NORTH AREA UNDER GE(U) E/M MEEERUT CANTT
2021_MES_478641_1
8362/E8
Open Tender
Electrical and Maintenance Works
Item Rate
150 days
Meerut Cantt
Please refer Tender documents.
11 documents required · 11 mandatory
₹500
GE(U) E/M Meerut Cantt
₹70,000
Yes
4 Jan 2022
29 Sept 2021
27 Oct 2021
29 Sept 2021
25 Oct 2021
13 Oct 2021
29 Sept 2021 - 6 Oct 2021
Amount
Supplying, laying or fixing, jointing and testing ( PVC insulated and sheathed LT electric power cable single core , ISI-1554 /IS-694 marked , with copper conductor , heavy duty 1100 Volts grade of 16 sqmm complete including taking down of existing unserviceable cable all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc.( Excavation, earth work, sand cushioning, protection bricks/ tiles/ block,clamps, nuts , bolts, washers and pipe shall be measured and paid separately under appropriate items ).
Supplying, laying or fixing, jointing and testing ( PVC insulated and sheathed LT electric power cable single core , ISI-1554 /SI-694 marked , with copper conductor , heavy duty 1100 Volts grade of 25 sqmm complete including taking down of existing unserviceable cable all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc.( Excavation, earth work, sand cushioning, protection bricks/ tiles/ block,clamps, nuts , bolts, washers and pipe shall be measured and paid separately under appropriate items ).
Supplying, laying or fixing, jointing and testing ( PVC insulated and sheathed LT electric power cable single core , ISI-1554 marked , with copper conductor , heavy duty 1100 Volts grade of 35 sqmm complete including taking down of existing unserviceable cable all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc.( Excavation, earth work, sand cushioning, protection bricks/ tiles/ block,clamps, nuts , bolts, washers and pipe shall be measured and paid separately under appropriate items ).
Supplying, laying or fixing, jointing and testing LT under ground electric power cable Crossed linked polyethylene ( XLPE Cable) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of 50 sqmm 3 1/2 core ,complete all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in pipes etc.( Excavation, earth work, sand cushioning, protection bricks/ tiles/ block,Clamps, nuts , bolts, washers and pipe shall be measured and paid separately under appropriate items ).
Supplying, laying or fixing, jointing and testing LT under ground electric power cable Crossed linked polyethylene ( XLPE Cable) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of 70 sqmm 3 1/2 core ,complete all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc.( Excavation, earth work, sand cushioning, protection bricks/ tiles/ block,Clamps, nuts , bolts, washers and pipe shall be measured and paid separately under appropriate items ).
Supplying, laying or fixing, jointing and testing LT under ground electric power cable Crossed linked polyethylene ( XLPE Cable) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of 95 sqmm 3 1/2 core ,complete all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc.( Excavation, earth work, sand cushioning, protection bricks/ tiles/ block,Clamps, nuts , bolts, washers and pipe shall be measured and paid separately under appropriate items ).
Taking down of existing unserviceable MCCBs and S&F MCCB, 4 pole,160 Amps, Icu=50KA, 415 volts, 50 hz, AC , with fixed thermal and fixed magnetic release duly connected with copper spreader links and proper size lugs, nuts, bolts and washers for proper connections,for 50hp motor all as specified and directed.
Taking down of existing unserviceable MCCBs and S&F MCCB, 4 pole, 200 Amps, Icu=50KA, 415 volts, 50 hz, AC , with fixed thermal and fixed magnetic release duly connected with copper spreader links and proper size lugs, nuts, bolts and washers for proper connections,for 75 HP motor all as specified and directed.
Taking down of existing unserviceable MCCbs and S&F MCCB, 4 pole, 125 Amps, Icu=50KA, 415 volts, 50 hz, AC , with fixed thermal and magnetic release duly connected with copper spreader links and proper size lugs, nuts, bolts and washers for proper connections,up to 22.5 HP motor all as specified and directed.
Taking down of existing unserviceable thimbles and S&F Aluminium thimble suitable for LT Aluminium cable of size 70 to120 Sqmm, 3.5 core complete all as spercified and directed.
Taking down of existing unserviceable thimbles and S&F Aluminium thimble suitable for LT Aluminium cable of size upto 35 Sqmm, 3.5 core complete all as spercified and directed.
S&Fand testing in repair main switch 4poles, 200 Amps side handle with MS sheet enclouser complete all as specified and directed.
Taking down of existing changeover switch and Supplying, fixing and testing 100 Amps, 415V, 4 pole off load changeover switch with sheet metal enclosure, side handle operated , 50 Hz, fixed to walls/ panels with suitable size clamps, nuts, bolts and washers complete all as specified and directed including making connections and testing complete all as specified and directed.
Taking down of existing changeover switch and Supplying, fixing and testing 200 Amps, 415V, 4 pole off load changeover switch with sheet metal enclosure, side handle operated , 50 Hz, fixed to walls/ panels with suitable size clamps, nuts, bolts and washers complete all as specified and directed including making connections and testing complete all as specified and directed.
Taking down of existing changeover switch and Supplying, fixing and testing 400 Amps, 415V, 4 pole off load changeover switch with sheet metal enclosure, side handle operated , 50 Hz, fixed to walls/ panels with suitable size clamps, nuts, bolts and washers complete all as specified and directed including making connections and testing complete all as specified and directed.
Dismantiling electric motor carefully from borewell after disconnecting the electric connections from panel board manually or mechanically and transporting both way to work shop and back, installation, refixing, reconnecting at site where directed after necessary repairs carried out and testing complete as directed by Engr-in-Charge for Electric motor 12 to 40 HP, 3 phase, 400/ 415 volts, 50 c/s of any make / type. Note:- Repairs and Parts Renewed shall be measured and paid for separately.Quoted rates deemed to include transportation charges including loading and unloading and labour charges for dismantling and refixing complete.
Dismantiling electric motor carefully from bore well after disconnecting the electric connectons from panel board manually or mechanically and transporting both way to work shop and back, installation, refixing, reconnecting at site where directed after necessary repairs carried out and testing complete as directed by Engr-in-Charge for Electric motor 50 HP, 3 phase, 400/ 415 volts, 50 c/s of any make / type. Note:- Repairs and Parts Renewed shall be measured and paid for separately.Quoted rates deemed to include transportation charges including loading and unloading and labour charges for dismantling and refixing complete.
Dismantiling electric motor carefully from bore well after disconnecting the electric connectons from panel board manually or mechanically and transporting both way to work shop and back, installation, refixing, reconnecting at site where directed after necessary repairs carried out and testing complete as directed by Engr-in-Charge for Electric motor 75 HP, 3 phase, 400/ 415 volts, 50 c/s of any make / type. Note:- Repairs and Parts Renewed shall be measured and paid for separately.Quoted rates deemed to include transportation charges including loading and unloading and labour charges for dismantling and refixing complete.
Assessing the repairs to be carried out to the motors after dismantling and carrying out the neccessary repairs to motors by opening the electric motor carefully removing all burnt/wornout coils cleaning the slots and rewinding with super enamelled copper wire of existing size including varnishing two coats, drying and reassembling the electric motor at site and testing the smooth running of the motor on full load for 08 hours continuously for Electric motor of capacity 75 HP 3 phase, 400/ 415 volts, 50 c/s of any size /shape and make. Note: Payment of bearing shall be measured and paid separatly under relevant items .
Assessing the repairs to be carried out to the motors after dismantling and carrying out the neccessary repairs to motors by opening the electric motor carefully removing all burnt/wornout coils cleaning the slots and rewinding with super enamelled copper wire of existing size including varnishing two coats, drying and reassembling the electric motor at site and testing the smooth running of the motor on full load for 08 hours continuously for Electric motor of capacity 50 HP to 60 HP 3 phase, 400/ 415 volts, 50 c/s of any size /shape and make. Note: Payment of bearing shall be measured and paid separatly under relevant items .
Assessing the repairs to be carried out to the motors after dismantling and carrying out the neccessary repairs to motors by opening the electric motor carefully removing all burnt/wornout coils cleaning the slots and rewinding with super enamelled copper wire of existing size including varnishing two coats, drying and reassembling the electric motor at site and testing the smooth running of the motor on full load for 08 hours continuously for Electric motor of capacity12 to 40 HP 3 phase, 400/ 415 volts, 50 c/s of any size /shape and make. Note: Payment of bearing shall be measured and paid separatly under relevant items .
Lifting of electric motor 22.5 HP to 75 HP capacity from existing position after disconnection of all electrical connection for renewal of U/S bearing and applying grease after removal of old grease and re-installing at site where directed after refilling new grease and reconnecting all electrical connection and testing complete. Note : (a) Necessary payment for bearing shall be measured and paid separately under relevant items if required at site. (b) Quoted rate deemed to include cost of grease as required at site. (c) The contractor shall lift the motors as directed by the dept for normal servicing even no repairs are reqd for the motor.
Dismantling mono block motor carefully after diconnecting the electric connections from panel board mannually or mechanically and transporting both way to workshop and back, installation, re-fixing, reconnecting at site where directed after necessary repair and carried out and testing comlete as directed for electric motor 05 to 15 HP , three phase 400/415 volts , 15 Hz of any make/ type. Note: Repairs and parts renewed shall be measured and paidfor separately. Quoted rates deemed to include transportation ncharges including loading and unloading and labour charges for dismantling and re-fixing complete.
Assessing the repairs to be carried out to the motors after dismantling and carrying out the neccessary repairs to motors by opening the electric motor carefully removing all burnt/wornout coils cleaning the slots and rewinding with super enamelled copper wire of existing size including varnishing two coats, drying and reassembling the electric motor at site and testing the smooth running of the motor on full load for 08 hours continuously for Electric motor of capacity 5 to 15 HP 3 phase, 400/ 415 volts, 50 c/s of any size /shape and make. Note: Payment of bearing shall be measured and paid separatly under relevant items .
Renewal of Thrust bearing No. 7220 including dismantling/taking out unserviceable thrust bearing of any make, for 50 HPcomplete all as specified and directed.
Renewal of Thrust bearing No. 7316 including dismantling/taking out unserviceable thrust bearing of any make,up to 75 HP complete all as specified and directed.
Renewal of Thrust bearing No. 29324 including dismantling/taking out unserviceable thrust bearing of any make for 75 HP, complete all as specified and directed.
Renewal of Ball bearing No. 6312 including dismantling/taking out unserviceable thrust bearing of any make for 22.5 HP, complete all as specified and directed.
Renewal of Ball bearing No. 6316 including dismantling/taking out unserviceable thrust bearing of any make upto 50 HP, complete all as specified and directed.
Renewal of Ball bearing No. 6311 including dismantling/taking out unserviceable thrust bearing of any make for 50 HP, complete all as specified and directed.
Renewal of Ball bearing No. 6313 including dismantling/taking out unserviceable thrust bearing of any make for 22.5 HP, complete all as specified and directed.
Renewal of Ball bearing No. 6308 including dismantling/taking out unserviceable thrust bearing of any make for 22.5 HP, complete all as specified and directed.
Renewal of Ball bearing No. 6309 including dismantling/taking out unserviceable thrust bearing of any make, for 22.5 HP complete all as specified and directed.
Renewal of Ball bearing No. 6309 including dismantling/taking out unserviceable thrust bearing of any make upto 22.5 HP complete all as specified and directed.
M & L for bearing sheet of motor of capacity up to 75 HP motor including lathe work, brazing etc complete all as specified and directed.
Replacement of old damaged CI centrifugally cast motor head assembly complete with fastening nut and glane housing(make as per original manufacturer) for motor of capacity up to 75 HP of vertical turbine pump.
Dismantling carefully turbine pump set bowl assembly of any make, capacity upto 50000 GPH and size complete with out damaging any parts of the pump and setting aside in pump house for ascertaining the serviceability of existing parts with the following :- (a) Through dismantling and cleaning of complete bowl assembly items such as CI bowls, impeller, lock collets, bowl bush, suction and discharge case with GM bush including pump shaft. (b) Cleaning of all rotary and stationary parts of pump bowl assembly and making them for their satisfactory run. (c) Re-assembling the complete bowl assembly pump with all existing serviceable parts and renew the worn out unserviceable parts including S & F gasket ,lathe work and balancing of assembly others small nature of indispensable items as required for repairing. Note :- Parts renewed shall be measured and paid for separately under respective item of Schedule 'A'/BoQ. Cost of labour for replacement of parts and fixing of new parts shall be deemed to include in the rate quoted by tenderer.
Replacement of old damaged CI centrifugally cast bowl assembly complete with gun metal bush ( make as per original manufacturer) for pump of capacity up to 50000 GPH of vertical turbine pump .
Replacement of old damaged GM impeller ( make as per original manufacturer) for vertical turbine pump of capacity up to 50000 GPH of any type.
Replacement of old damaged Stainless steel non magnetic pump shaft 25 to 32 mm ( make as per original manufacturer) suitable for 6 to 9 stage pumps (Bowl assembly) as directed .
Replacement of old damaged M.S. line shaft (bright) steel 25 to 32 mm dia 10 Ft long with MS coupling and non magnetic stainless steel sleeve ( make as per original manufacturer) all as specified and directed.
Replacement of old damaged Shaft coupling / sleeve of high carbon steel for 25 mm to 32 mm dia lineshaft ( make as per original manufacturer) all aspecified and directed.
Replacement of old damaged GM Bush for suction case for Vertical turbine pump upto 50000 GPH capacity ( make as per original manufacturer) all aspecified and directed.
Replacement of old damaged CI guide spider heavy duty with rubber bush and check nut suitable for 25 to 32 mm dia lineshaft of 150 mm bore pipe ( make as per original manufacturer) all aspecified and directed.
Replacement of old damaged CI guide spider heavy duty with rubber bush and check nut suitable for 25 to 32 mm dia lineshaft of 200 mm bore pipe ( make as per original manufacturer) all aspecified and directed.
Replacement of old damaged Rubber packing for discharge head upto 200 mm bore complete all as specified ( make as per original manufacturer) all aspecified and directed.
Replacement of old damaged Rubber bush for guide spider for 25 to 32 mm dia lineshaft ( make as per original manufacturer) all aspecified and directed.
Replacement of old damaged M.S. line shaft (bright) steel 25 to 32 mm dia 10 Ft long with MS coupling and non magnetic stainless steel sleeve ( make as per original manufacturer) all as specified and directed.
Replacement of old damaged Stainless Steel non magnetic pump shaft 25 to 32 mm ( make as per original manufacturer) dia suitable for 6 to 9 stage pumps (Bowl assembly)all aspecified and directed.
Replacement of old damaged Shaft couling/sleeve of high carbon steel for 25 to 32 mm dia line shaft ( make as per original manufacturer) all aspecified and directed.
Replacement of old damaged Stainless Steel top shaft not exceeding 32 mm dia and 3 mtr long, duly threaded both ends and made suitable slot for fixing the stainless steel key adjusting nut & lock washer ( make as per original manufacturer) all aspecified and directed.
Replacement of old damaged CI Centrifugally cast suction case with GM Bush (make as per original manufacturer) all aspecified and directed.
Replacement of old damaged CI Centrifugally cast discharge case with GM Bush ( make as per original manufacturer) all aspecified and directed.
Replacement of old damaged Mild steel cold drawn ERW column pipe 3.00 M long, wall thickness not less than 7.2 mm thick, 150 mm bore, both ends flanged with Mild steel column coupling 12 mm thick including welding, flanged joint on both ends complete all as specified and directed by Engr-in-Charge
Replacement of old damaged Mild steel cold drawn ERW column pipe 3.00 M long, wall thickness not less than 7.2 mm thick, 200 mm bore, both ends flanged with Mild steel column coupling 12 mm thick including welding, flanged joint on both ends complete all as specified and directed by Engr-in-Charge
Replacement of old damaged Mild steel cold drawn ERW column pipe 3.00 M long, wall thickness not less than 7.2 mm thick, 100 mm bore, both ends flanged with Mild steel column coupling 12 mm thick including welding, flanged joint on both ends complete all as specified and directed by Engr-in-Charge
Replacement of old damaged Mild steel cold drawn ERW column pipe 3.00 M long, wall thickness not less than 7.2 mm thick, 80 mm bore, both ends flanged with Mild steel column coupling 12 mm thick including welding, flanged joint on both ends complete all as specified and directed by Engr-in-Charge
Replacement of old damaged Ratchet assembly complete with ratchet plate, ratchet balls hexagonal bolts etc suitable for up to 75 HP electric motor and vertical turbine pump ( make as per original manufacturer) all aspecified and directed.
Replacement of old damaged Ratchet plate suitable upto 75 HP VT motor and vertical turbine pump ( make as per original manufacturer) all aspecified and directed..
Replacement of old damaged GM neck ring suitable for 100mm/150mm/200mm dia VT pump and vertical turbine pump ( make as per original manufacturer) all aspecified and directed.
Replacement of old damaged PVC rubber Gasket 3 mm thick suitable upto 200 mm bore flanged joints .
Replacement of old damaged Rubber bowl bush suitable for VT pump set and vertical turbine pump ( make as per original manufacturer) all aspecified and directed.
Replacement of old damaged Intermediate bowl bush GM suitable for VT pump set and vertical turbine pump ( make as per original manufacturer) all aspecified and directed.
Replacement of old damaged GM Impeller lock collect suitable for VT pump set and vertical turbine pump ( make as per original manufacturer) all aspecified and directed.
Replacement of old damaged CI fitting box (Gland box) of suitable type & shape for VT Pump and vertical turbine pump ( make as per original manufacturer) all aspecified and directed.
Replacement of old damaged Mild steel full threaded bolts of suitable size having hexagonal head with one 3 mm thick washer and nut suitable for jointing 100/150/200 mm bore flanged joints complete all as specified.
Replacement of old damaged Gun Metal split gland of any size & shape with G I clamp suitable for gland box of VT pump and vertical turbine pump ( make as per original manufacturer) all aspecified and directed.
Lowering of turbine pump set any type and capacity upto 50000 GPH re-assembling of all accessories and column pipe after cleaning manually including fixing of motor in existing position making all Electrical & water supply connections and adjustment of pump load etc and testing of pump and motor after installation all as directed by Engr-in-Charge.
Cutting, facing of existing mild steel cold drawn ERW column pipe upto 200 mm dia to desired length and re-threading up to 80 mm run to suit existing coupling complete all as directed. Note :- Rate quoted by tenderer shall be deemed to include all transportation charges from site to work shop and back incl loading/unloading.
Cutting, facing of existing mild steel lineshaft up to 32 mm dia to desired length and re-threading up to 80 mm run as directed. Note :- Rate quoted by tenderer shall be deemed to include all transportation charges from site to work shop and back incl loading/unloading.
Cutting existing MS/BS/SS top shaft of size upto 32 mm dia making slot for key and rethreading both ends for required length to suit the coupling and load adjusting shaft nut all as directed by EIC.
Taking out rusted after disorienting old worn pump M S foundation bolt from cement concrete foundation base and fixing by providing new mild steel full threaded bolt of 20 mm dia not exc.300 mm long with proper cement concrete foundation (1:2:4) type B-1 using 20mm graded crushed stone aggregate and makeing the surface smooth to match with existing surface complete all as directed.
Repairing the base of discharge head of VT pump up to 50000GPH by Welding and renewing high carbon steel nut for the base of discharge head, including renewal of mild steel channel complete all as directed.
Renewal of Heavy duty terminal plate made of bakelite suitable for electric motor of capacity 30/40/50/75 HP with brass nuts of suitable size best quality as approved by GE complete all as specified and directed.
Renewal of Terminal plate cover made of CI for fixing over the terminal plate with cover for 30/40/50/ HP electric motor best quality as approved by GE complete all as specified and directed.
Labour for lifting of submersible pump along with flanged column pipe, submersible cable, safety rope etc from the existing bore well by using suitable T&P etc after disconnecting submersible cable from starter making necessary repairs by opening including transporting to workshop and back and renewal of worn out parts as required complete all as specified & directed for 10 HP to 30 HP capacity pumpset. Note: Parts Renewed shall be measured and paid separately
Supply only Gunmetal impellers suitable for 10 to 25 HP Submersible pump
Supply only Gunmetal bush suitable for 10 to 25 HP Submersible pump
Supply only stainless steel sleeve suitable for 10 to 25 HP Submersible pump
Supply only 'C' type bushes for impellers suitable for 10 to 25 HP Submersible pump
Supply only Bowel case suitable for 10 to 25 HP Submersible pump
Supply only stainless steel shaft of standard size complete in all respect suitable for 10 to 25 HP Submersible pump
Labour for lifting of submersible pump along with flanged column pipe, submersible cable, safety rope etc from the existing bore well by using suitable T&P etc after disconnecting submersible cable from starter making necessary repairs by opening including transporting to workshop and back and renewal of worn out parts as required complete all as specified & directed for 2HP to 7.5 HP capacity pumpset. Note: Parts Renewed shall be measured and paid separately
Supply only Gunmetal impellers suitable for 2 to 7.5 HP Submersible pump
Supply only Gunmetal bush suitable for 2 to 7.5 HP Submersible pump
Supply only stainless steel sleeve suitable for 2 to 7.5 HP Submersible pump
Supply only 'C' type bushes for impellers suitable for 2 to 7.5 HP Submersible pump
Supply only Bowel case suitable for 2 to 7.5 HP Submersible pump
Supply only stainless steel shaft of standard size complete in all respect suitable for 2 to 7.5 HP Submersible pump
Lowering down of submersible pump set along with connected items such as column pipes ,submersible cable by using suitable T&P and reconnecting all electrical connections,commissioning & testing complete all as specified & directed for 10 HP to 30 HP capacity pumpset.
Lowering down of submersible pump set along with connected items such as column pipes ,submersible cable by using suitable T&P and reconnecting all electrical connections,commissioning & testing complete all as specified & directed for 2 HP to 7.5 HP capacity pumpset.
M & L for Rewinding of submersible motor electric driven , AC supply with PVC insulated copper wire (ISI marked) as per existing gauge ,including connected works for rewinding .The scope of works includes dismantaping ,removal of old wiring wire ,cleaning of slots & rewinding ,reassembling,testing complete all as specified & as directed for 10 HP to 30 HP capacity of pump motors. (Other parts required for repair will be measued and paid for separately under respective sch item.) .
Supply only Gunmetal bush for submersible motor suitable for 10 to 25 HP
Supply only Thurst bearing for submersible motor suitable for 10 to 25 HP
M&L for Rewinding of submersible motor electric driven , AC supply with PVC insulated copper wire (ISI marked) as per existing gauge ,including connected works for rewinding .The scope of works includes dismantaping ,removal of old wiring wire ,cleaning of slots & rewinding ,reassembling,testing complete all as specified & as directed for 02 HP to 7.5 HP capacity of pump motors. (Other parts required for repair will be measued and paid for separately under respective sch item.) .
Supply only Gunmetal bush for submersible motor suitable for 2 to 7.5 HP
Supply only Thurst bearing for submersible motor suitable for 2 to 7.5 HP
S & F (in repair) Submersible cable flat ,water proof,PVC insulated,PVC sheathed ,3 core,10 sqmm,1100 volts grade ,multistranded copper conductor including making water proof cable joint with submersible motor and normal connections through lugs/thimbles into starter panel complete all as specified and directed.
S & F (in repair) Submersible cable flat ,water proof,PVC insulated,PVC sheathed, 3 core,16 sqmm,1100 volts grade ,multistranded copper conductor including making water proof cable joint with submersible motor and normal connections through lugs/thimbles into starter panel complete all as specified and directed.
Disconnecting & taking out/opening of the non-functional 3 phase servo voltage stabilizer of any description in any position for taking out unserviceable / defective wiring & parts, cleaning and servicing complete including renewal of unserviceable parts complete, draining-out of transformer oil for repair work renewal of unserviceable wiring with new copper wire cable of existing size, reassembling ,connecting and testing complete all as specified and directed by Engineer-in-Charge for three phase 50 KVA capacity . Notes :- (i) Parts renewed shall be measured and paid for separately under appropriate item of Sch ‘A’ at supply only rates but fixing of the parts replaced/repaired/Renewed is deemed to be included in this item. (ii)Transformer oil shall be drained out carefully, collected by the contractor in his own suitable containers and stored properly all as directed by the Engineer-in-Charge. (iii) Tenderer Quoted rate shall be deemed to include for all transporting charges including loading/unloading to workshop and back where required complete all as specified.
Supply only Micro toggle switches all as specified.
Supply only Auto manual switches . all as specified.
Supply only high and low voltage indicator light complete all as specified.
Supply only panel indicator light for main "ON' indication all as specified.
Supply only potential meter all as specified.
Supply only Electronic sensing card (Printed circuit Board all as specified.
Supply only 12 pin connector all as specified.
Supply only rotary mechanism of dimmer through armature motor for capacities of stabilizers 03 phase up to 75 KVA all as specified.
Supply only Servo motor 10 kg torque all as specified.
Supply only RC network for servo motor 10 KG all as specified.
Supply only Trigger Transformer 440 V to 220 V all as specified.
M&L for rewinding of Buck booster transformer with super enamel copper wire including paper insulation packing, varnishing etc including taking out old burnt winding complete all as specified and directed, for three phase 50 KVA capacity of stabilizers.
M&L for rewinding of Dimmer with super enamel copper wire including paper insulation packing, varnishing etc including taking out old burnt winding complete all as specified and directed, for 50 KVA capacity of stabilizers.
M&L for rewinding of Dimmer with super enamel copper wire including paper insulation packing, varnishing etc including taking out old burnt winding complete all as specified and directed, for 75 KVA capacity of stabilizers.
Renewal of Insulators, vitreous, suitable for voltage stabilizers up to 160 Amps current rating, complete all as specified.
M&L new transformer oil in servo voltge stabilizer to fulfil upto required level. Note: break down value of transformer oil should not be less than dielectric strength 50 KV .
M&L for dehydration / filteration of transformer oil in servo voltage stabilizer breakdown value of transformer oil should not less than dielectric strength 50 KV . Note : Contractor will arrange filtration plant machine at site of voltage stabilizer transformer oil dehydration work will be carried out in working condition .
M&L for preparation of old painted surface of steel / iron of servo voltage stablizer of any capacity by scaping with emery/sand paper,brushing, cleaning, staining grease/oily spots with thinner and applying two coats of superior quality synthetic enamel paint with spray machine over a coat of primer complete all as specified and directed.
Supply & fix Single/reverse phase preventor for motor protection with by pass arrangements to run the motor in case of emergency with low/high voltage cut off and time delay/relay of 1 to 3 sec.including dismantling/taking out of unserviceable phase preventor of any make and type complete all as specified and directed.
Repair of existing control panel including making good of panel surface and painting with epoxy powder coating. Repair will also include refabrication of broken panel doors (if required) and reconnection all items after repair in proper order as directed by Engr in charge.
Supply and fixing Contactor 03 pole 60 Amp suitable for star delta stater 12 to 30 HP with motor 415 V .AC Coil including repair/replacement of wiring complete all as specified .Make L&T ,SEIMENS,HAVELLS ETC set comprising of 03 Nos moving contacts & 06 Nos. fixed contacts delta starter complete all as specified and directed.
Supply and fixing Contactor 03 pole 180 Amp suitable for star delta stater 50 TO 75 HP with motor 415 V/220 V .AC Coil including repair/replacement of wiring complete all as specified . comprising of 03 Nos moving contacts & 06 Nos. fixed contacts Star- delta starter upto 75 HP complete all as specified and directed.
Supply and fixing FRLS cable 1.5 sqmm size for control wiring of panel board
Supply and fixing MCB double pole 16 amps current rating B series Make: C&S ,Havells,Shalabh,Indoasian etc.
Supply and fixing Electronic Timer ET 100, 110/240 Volts, 50 Hz, range 9-30 seconds complete all as specified.
Supply and fixing overload relay 110/240 Volts,50 Hz range 9-30 seconds complte all as specified.
Supply and fixing in repairs push button actuators with carrier and contact element of type flush spring return with 1 NO/1NC/2NO block(red/green colour) all specified
Supply and fixing repairs tape wounded CT 200/5 Ration all as specified.
Repair to phase sequence changer of any type /make capacity 22.5 HP to 75 HP including renewal of U/S parts and wiring as required to made the sequencer serviceable condition.
S&F testing and commissioning of Motor protection circuit breaker suitable for 22.5 to 75 HP VT/submersible motor pump with defect sensing and digital display all as specified and directed by Enr-in-Charge.
S&F (in repairs) of VT Motor 3 Phase 415 Volt 50 hz of cpacity 50 HP complete all as specified and directed.
NITHYA INFRATECH
Santosh Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .