Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.1 LAccepted-Finance | ₹32.1 L | L1 | Accepted-Finance Lowest and Reasonable bid. |
| 2 | L2₹37.7 L+₹5.6 L (17.3%)Accepted-Finance | ₹37.7 L+₹5.6 L (17.3%) | L2 | Accepted-Finance Other than the lowest bid. |
| 3 | L3₹40.3 L+₹8.2 L (25.4%)Accepted-Finance | ₹40.3 L+₹8.2 L (25.4%) | L3 | Accepted-Finance Other than the lowest bid. |
| Sl No | Description | Qty | Unit | AXIS SALES L2 | Rakesh Dhingra Contractor L1 | LOVELY AIRCON SYSTEMS L3 |
|---|---|---|---|---|---|---|
| 1.00 | Maintenance, servicing and testing of split type/window type AC, capacity 1.5/2.0 ton, any make, by cleaning cooling coil, condenser fins, blowing of dust from machines/air filters, checking and decarbonising all electric system oiling/greasing of blower motor, checking and removing any vibration and leakage in the equipment including checking/repair to inter locking device for winter/summer to ensure cutting off of compressor/heating in case of failure of blower motor including taking down and refixing in position complete all as directed by Engineer-in-Charge.
Note - Cost of minor repair, replacement of petty items such as nuts, bolts, washers, screws, rubber mounting pads of compressor etc, transportation of equipment to workshop and back is deemed to be inclusive in the unit rates quoted by the contractor. | 205 | Each Job | 329 ₹67,445 Lowest | 400 ₹82,000 | 400 ₹82,000 |
| 2.00 | WINDOW/SPLIT TYPE AIR CONDITIONER
Supply & fixing in replacement, new compressor for window/ split type AC 1.5 Ton capacity including disconnecting, opening up, taking out burnt compressor by cutting/opening the pipe connections, fixing in position, reassembling, testing and commissioning including gas & oil charging after flushing the line with CO2 gas to avoid trapping the water vapour ensuring leak proof system (Compressor should be company sealed and brand new suitable for gas R-410) complete all as specified and directed.
Make: Shriram / Kirloskar / Voltas / Carrier / Whirlpool
Note: Compressor shall be tested to entire satisfaction of Engr-in-Charge and test results recorded and kept on charge. | 20 | Each Job | 12,999 ₹2,59,980 | 13,000 ₹2,60,000 | 8,500 ₹1,70,000 Lowest |
| 3.00 | All as per Srl Item No 2.00 here-in-before but 2.0 Ton capacity complete all as specified and directed. | 10 | Each Job | 13,999 ₹1,39,990 | 8,000 ₹80,000 Lowest | 9,000 ₹90,000 |
| 4.00 | Material and labour for trickle charging of gas R-22/32/410 as required in Window/Splt AC of capacity 1.5 ton, after detection of leakage with soap solution/halide torch ,making the system leak proof by brazing/ soldering the leakage point, flushing out the moisture contents trapped in the pipe line by charging CO2 gas and maintaining the pressure for prescribed period complete all as specified and directed. | 70 | Each Job | 1,999 ₹1,39,930 | 1,700 ₹1,19,000 Lowest | 1,700 ₹1,19,000 Lowest |
| 5.00 | All as per Srl Item No 4.00 here-in-before but 2.0 Ton capacity complete all as specified and directed. | 25 | Each Job | 2,199 ₹54,975 | 1,700 ₹42,500 Lowest | 1,800 ₹45,000 |
| 6.00 | Supply & fixing nylon type filter pad 20 micron for window type AC of capacity up to 2 ton including taking out unserviceable filter pad complete all as specified and directed. | 10 | Each Job | 99 ₹990 | 50 ₹500 Lowest | 120 ₹1,200 |
| 7.00 | Supply & fixing, in replacement, running capacitor 4/5/6 MFD 230 volts for blower motor complete all as specified and directed.
Make : Keil / Asian /Tesla or equivalent. | 25 | Each Job | 99 ₹2,475 | 35 ₹875 Lowest | 80 ₹2,000 |
| 8.00 | All as per Srl Item No 7.00 here-in-before but 36 - 40 MFD complete all as specified and directed. | 25 | Each Job | 249 ₹6,225 | 160 ₹4,000 Lowest | 250 ₹6,250 |
| 9.00 | All as per Srl Item No 7.00 here-in-before but 45 - 50 MFD complete all as specified and directed. | 25 | Each Job | 289 ₹7,225 | 160 ₹4,000 Lowest | 300 ₹7,500 |
| 10.00 | All as per Srl Item No 7.00 here-in-before but 45+5 MFD complete all as specified and directed. | 25 | Each Job | 289 ₹7,225 | 160 ₹4,000 Lowest | 350 ₹8,750 |
Tender Value
₹39.3 L
EMD Value
₹78,500
Closing Date
20 Jul 2026, 6:00 pmClosed
GE (WEST) JRC
KABIR ROAD JALANDHAR CANTT
REPAIR MAINT OF SUMMER APPLIANCES AND COMPREHENSIVE MAINT OF AC PLANTS UNDER GE (W) JRC
2026_MES_774484_1
GE/JAL(W)-13/2026-27
Open Tender
Civil Works
Item Rate
335 days
JALANDHAR CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (WEST)
₹78,500
Yes
29 Jul 2026
24 Jun 2026
27 Jul 2026
24 Jun 2026
20 Jul 2026
8 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Maintenance, servicing and testing of split type/window type AC, capacity 1.5/2.0 ton, any make, by cleaning cooling coil, condenser fins, blowing of dust from machines/air filters, checking and decarbonising all electric system oiling/greasing of blower motor, checking and removing any vibration and leakage in the equipment including checking/repair to inter locking device for winter/summer to ensure cutting off of compressor/heating in case of failure of blower motor including taking down and refixing in position complete all as directed by Engineer-in-Charge.
Note - Cost of minor repair, replacement of petty items such as nuts, bolts, washers, screws, rubber mounting pads of compressor etc, transportation of equipment to workshop and back is deemed to be inclusive in the unit rates quoted by the contractor. | 205 | Each Job | - | - |
| 2 | WINDOW/SPLIT TYPE AIR CONDITIONER
Supply & fixing in replacement, new compressor for window/ split type AC 1.5 Ton capacity including disconnecting, opening up, taking out burnt compressor by cutting/opening the pipe connections, fixing in position, reassembling, testing and commissioning including gas & oil charging after flushing the line with CO2 gas to avoid trapping the water vapour ensuring leak proof system (Compressor should be company sealed and brand new suitable for gas R-410) complete all as specified and directed.
Make: Shriram / Kirloskar / Voltas / Carrier / Whirlpool
Note: Compressor shall be tested to entire satisfaction of Engr-in-Charge and test results recorded and kept on charge. | 20 | Each Job | - | - |
| 3 | All as per Srl Item No 2.00 here-in-before but 2.0 Ton capacity complete all as specified and directed. | 10 | Each Job | - | - |
| 4 | Material and labour for trickle charging of gas R-22/32/410 as required in Window/Splt AC of capacity 1.5 ton, after detection of leakage with soap solution/halide torch ,making the system leak proof by brazing/ soldering the leakage point, flushing out the moisture contents trapped in the pipe line by charging CO2 gas and maintaining the pressure for prescribed period complete all as specified and directed. | 70 | Each Job | - | - |
| 5 | All as per Srl Item No 4.00 here-in-before but 2.0 Ton capacity complete all as specified and directed. | 25 | Each Job | - | - |
| 6 | Supply & fixing nylon type filter pad 20 micron for window type AC of capacity up to 2 ton including taking out unserviceable filter pad complete all as specified and directed. | 10 | Each Job | - | - |
| 7 | Supply & fixing, in replacement, running capacitor 4/5/6 MFD 230 volts for blower motor complete all as specified and directed.
Make : Keil / Asian /Tesla or equivalent. | 25 | Each Job | - | - |
| 8 | All as per Srl Item No 7.00 here-in-before but 36 - 40 MFD complete all as specified and directed. | 25 | Each Job | - | - |
| 9 | All as per Srl Item No 7.00 here-in-before but 45 - 50 MFD complete all as specified and directed. | 25 | Each Job | - | - |
| 10 | All as per Srl Item No 7.00 here-in-before but 45+5 MFD complete all as specified and directed. | 25 | Each Job | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.24 MB
BOQ_867246.xls
BOQ • 0.35 MB
TenderDocuments13.pdf
Tender Documents • 0.76 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .