Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.9 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹30.4 L+₹3.5 L (13.2%)Rejected-Finance | L2 | Rejected-Finance Higher | |
| 3 | L3₹31.0 L+₹4.2 L (15.6%)Rejected-Finance | L3 | Rejected-Finance Higher | |
| 4 | L4₹32.3 L+₹5.4 L (20.3%)Rejected-Finance | L4 | Rejected-Finance Higher | |
| 5 | L5₹32.7 L+₹5.9 L (22.0%)Rejected-Finance | L5 | Rejected-Finance Higher |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
4 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NAMS
GE NAMS KHASA CANTT AMRITSAR
DAY TO DAY COMPLAINTS OF EXTERNAL ELECT SUPPLY AND ALLIED WORKS AT NAMS
2021_MES_473209_1
GE NAMS - 42 / 21 - 22
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
NAMS CANTT
Class D
Category b i
5 documents required · 5 mandatory
₹500
Yes
GE NAMS
₹76,000
Yes
30 Oct 2021
6 Sept 2021
5 Oct 2021
6 Sept 2021
4 Oct 2021
21 Sept 2021
60 days
Amount
Day to day attending complaints & maintaining the electric supply GE NAMS Area round the clock (24 Hours) comprising the following HT /LT net work / transformers / LT panels by contractor/his rep with fwg networks:-
Feeder No-1 emanating from 66 KV grid Sub station to TOP II, Appx length – 4.5 Km.
Feeder No-2 emanating from 66 KV grid Sub station to NME, Appx length = 1.8 Km, LT Panels , LT overhead lines appx – 2.50 km and 01 No transformer.
Feeder No 03 emanating from TOP I Sub station to Old Officer colony Feeder, Appx length = 3 Km along with 08 transformers with GOD s of different capacities , LT Panels , LT overhead lines appx – 4.5 km.
Feeder No 04 emanating from TOP I Sub station to Back Feeder Appx length = 3 Km along with 07 transformers of different size, LT Panels GOD's, LT over head line appx 4 Km.
Feeder No 05 emanating from TOP II Sub station to Old Kathania Accn Appx length = 2 Km along with 06 transformers GOD'S, LT Panels, LT over head line appx length 4.5 Km with cable/service connections.
Feeder No 6 emanating from TOP II Sub station to Back Feeder to Army school, central school Appx length = 3.5 Km along with 05 transformers of different cap with GOD's, LT Panels, LT over head line appx 1.5 Km.
Feeder No 7 emanating from TOP II Sub station to New officer Colony: & OTM 54 Bde HQ, 5 Kumaon,19 JAK, 415 Fd Hosp and 21 PUNAJB Appx length = 4 Km along with 08 transformers of different size with GOD's, LT Panels, LT over head line appx 3 Km with cable/service connections.
Feeder No 8 emanating from TOP II Sub station to NOC II, Appx length = 1 Km along with 01 transformer with GOD's, LT Panels over head line appx 2.5 Km.
Feeder No 9 emanating from TOP II Sub station to CP -6 baffle range Appx length = 4 Km along with 02 transformers of different size with GOD's, LT Panels, LT over head line appx 0.5 Km.
HT feeder No 10 emanating from 66 KV Sub station to New Red Colony, New Kathania & NOC-I Appx length = 2.5 Km along with 06 transformers of different size with GOD's, LT Panels, LT over head line/UG Cable appx 3 Km with cable/service connections.
Preodicity - round the clock
Nature of work to be done -
Maintaining the serviceability and attending break down complaints of electric supply of all the feeder of New Asr Cantt area mentioned under Sl 2.01 to 2.12 here in before .
Attending the complaint of external electric supply – from pole to main board / DB of the occupant .
Periodical maintenance/complaints of all the feeders mentioned here-in=-before which includes – (a)Replacement of overheated jumper / blown off jumpers .
Replacement of blown off HT fuses .
Periodical complaints of LT panels .
Suitable Wooden ladder shall be provided by the contractor to do the complaint without any extra cost.
Vehicle shall not be provided by the Department.
Complaint to be done approxmatly 1 to 2 hrs otherwise penalty to be made at @ Rs. 500/- per complaint.
Complaint Register & complaint slip shall be maintained by the contractor and signature of JE / Engr in charge will be taken on each complaint after completion of complaint on daily basis without signature complaint slip will not be accepted and no payment shall be paid to the contractor for such complaint slip. Note :- No extra cost shall be paid to the contractor for complaint register and complaint slip.
Note – Time consuming jobs such as replacement of defective cable by extension of loop and periodical trimming of trees / branches along the over head lines shall be measured and paid separately .
Contractor provide high power torch -02 Nos for each sub stn and safety belt to each electrician to carry out complaints. No extra amount shall be paid to the contractor for the same.
Mandatory tools to be provided to the electrician– Insulting plier , cutter , screw drivers , DE spanner set , clamp meter, earth tester and cable fault loactor . No extra cost will be paid to the contractor for these tools.
Before attending any complaints of external elect supply contractor or his rep shall ensure that proper shut down has been taken & timing of shut down shall be entered in shut down register.
All safety precaution will be taken by the Contractor/his rep incase of any lapse contractor will be responsible for the same.
Contractor will provide shut down permit book for taking shut down permit from the JE/ Engr-in-Charge. No extra cost will be paid for the same.
Excavation trenches not exceeding 1.5m wide & not exceeding 1.5m in depth for and getting out in any of soil complete all as specified and as directed.
Excavation in trenches exceeding 1.5m/in width & not exceeding 3m in depth for and getting out in any of soil complete all as specified and as directed.
Returning, filling including spreading, leveling, watering and well ramming in layers not exc 25 cm thick all as specified and directed.
Removal of surplus excavated soil to a distance not exc 50m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine for road crossing GI tubing of any size for cable protection complete all as specified and directed.
Material and labour for sand cushioning with a layer of fine sand 8 cm thick before laying the cable and 15 cm after laying the cable in trenches to cover under ground cable complete all as specified and directed. Note :-Punned down thickness of sand shall be considered for measurement)
M & L for sub class "B" brick covering laid dry flat (width equal to be length of the bricks) over sand cushioning along the length of cable complete all as specified and directed.
Supply laying in replacement & testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (Heavy duty) LT 1100 volt grade with stranded aluminium conductor of size 185 sqmm 3.5 core complete all as specified and directed.
All as per srl item No 10 here-in-before but of size 120 Sqmm 3.5 core.
All as per srl item No 10 here-in-before but of size 50 Sqmm 3.5 core.
All as per srl item No 10 here-in-before but of size 35 Sqmm 3.5 core.
All as per srl item No 10 here-in-before but of size 25 Sqmm 4 core.
All as per srl item No 10 here-in-before but of size 16 Sqmm 4 core.
All as per srl item No 10 here-in-before but of size 16 Sqmm 2 core.
Supply,laying & fixing in replacement double wall corrugated (DWC) pipes made of high density polythyline (HDPE) with all accessories i.e. all type of joints,Sockets,Elbows,bends and End caps etc.. all as specified and directed by Engr in Charge of size 50mm outer dia and 38mm inner dia
All as per items No 17 here in before but of size 77mm outer dia and 63mm inner dia
All as per items No 17 here in before but of size 90mm outer dia and 76mm inner dia
All as per items No 17 here in before but of size 145mm outer dia and 126mm inner dia
Supply and fixing in replacement danger notice plate of 1.6mm thick mild steel sheet , virtreous enameld white, with letters , figures and conventional skull and bones in signal red colour(in three language) and fixed with MS clamps , bolt and nuts of approved size for LT 20 X 15 CM size complete all as specified and directed.
All as per items No 21 here in before but for 66 KV/11KV HT of size 25 x 20CM
Excavates and relaying cables loops near the poles LT Panels transformers, cutting the damages/burnt parts of cable and reconnecting its into positions complete with thimbles, nut bolts, sleaves all as specified and directed by Engineer-in-Charge.
S & F in replacement straight through/end termination joint heat shinkable of any size suitable for 3 core 11000 volts XLPE HT UG cable of size 70 Sq mm to 120 Sq mm complete all as specified and directed.
Material and Labour in replacement straight through joint/End temination kit of heats shrinkable suitable for above 185 sqmm to 300 sqmm HT 3 core 11000 volts XLPE cable type complete all as specified and directed.
Supply and erect steel tubular swaged poles complete with cast iron base plate, final taper plug, bolts nuts & screws as specified type 410 SP-31 ( 9 mtr long) erecting in position all as specified/shown on drawing and as directed by Engr-in-Charge Note: (i) Excavation Earth work and foundation will be measured and paid seperately under relevent items.
Supply and fixing LED type street light fitting pressure die cast aluminium housing(Heat sink)for effective thermal management,IP 66,Operating Voltage 140-270 Volts, with Lens and Surge Voltage Protection of luminaires 60 watt LED 6000K complete fitting including 1.50mtr(minimum) 2core PVC insulated aluminium cable from conductor to street light fitting all as specified.
Material and labour in replacement for ACSR conductor any size drawn straight horizontal on over head lines on existing poles including binding with insulators weight of conductor shall be measured straight horizontal distance between centre of two adjacent HT/LT poles and calculating weight of conductor of size length by adding 3% extra for sag jointing jumpers etc complete all as specified and directed.
Supply & fixing in replacement of LT stay assembly comprising of 7/3.15mm galvanized MS stay wire of reqd length, fixed to poles with and including of FI clamps made out of FI 40x6mm and nuts bolts washers of suitable size MS stay bow 14mm dia galvanized 40cm long MS galvanised stay rod threaded with nut 16mm dia 21 Cm long with washers MS stay plate galvanized 230x30x6mm incl necessary Excavation and PCC all as specified and directed by Engr-in charge
S&F in replacement loop type porcelain white, brown or green small size with cover dimensions of 65x 90 mm clearance of whole 16 mm as specified and directed by Engr-in charge.
S/F galvanised steel stranded stay wire size 7/4mm for stay assembly
Replacement of pin type porcelain white, brown or green insulator including one galvanized mild steel spindle, two galvanised iron washers & one galvanised nut 50mm height,65mm dia for working pressure 1100 volts grade.all as specified and directed by Engr-in charge
S & F in shackle type,vetrious Insulator incl one galvanised mild steel spindle, two galvanised iron washerrs,and one galvanised iron nut, 100 mm height, 115 mm dia ,suitable for 1100 Volt,and as directed by engineer in charge.
M & L in replacement cross arms bracings supports clamps and back plates fabricated from structural steel sections including nut bolts washers welding bending cold and hot drilling holes for bolts in any shape or size as indicate or directed and inclusive of one primer coat one under coat and one finishing coat of paint.
M & L in replacement Pre stressed concerete pole 9 mtr long of cross section of 102mm x 172mm at top and 102mm x 279 mm at bottom class 10 complying with requirement of IS-1678-1978 including painting of poles with two coats of synthetic paint in black & white step each upto 1.5 mtr high from coping over a coat of primer including numbering of poles as directed. Note:- (i) Exavation and foundation will be paid and measure separetly.
Supply and spraying anti vegetation chemical liquid of 1ltrs bottle mixed with water as per direction of Engr in charge .
Material & labour for providing precast cement concrete 1:2:4, type B-1, using 20 mm graded aggregate in landings, cover slabs (for man holes etc) chajjas, water trouhghs, shelves and similar articles including form work complete all as specified and directed.
Supply and fill up transformer oil topping up having dielectric strength not less than 50 KV at 4 mm gap conforming to IS complete all as specified and directed.
Supply & fixing in replacement Pin/Disc type type porcelain vitreous white, brown or green insulator including one galvanised mild steel straps, washers and nut for 11000 volts grade, including removal of existing insulators complete all as specified and directed.
Supply & Fix in replacement flood Light Luminaire 120 watt with .high power SMD LED cool white, supply voltage 220/240/50 Hz, light engine driver base.pole adapter, pressure die cast LM6 diffusor:injection model polycarbonate, powder coated in IP 66 Including protection over temperature complete all as specified and directed.
Supply & Fix in replacement flood Light Luminaire 150 watt with .high power SMD LED cool white,CRI 75,+/- 5% supply voltage 220/240/50 Hz, light engine driver base.pole adapter, pressure die cast LM6 diffusor:injection model polycarbonate, powdre coated in IP 66 Incliding protection over temperature complete all as specified and directed.
Supply laying in replacement & testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (Heavy duty) LT 1100 volt grade with stranded aluminium conductor of size 300 sqmm 3.5 core complete all as specified and directed.
Material and labour for preparing old painted surface of panel board by cleaning removing of old paint by scratching with wire brush / sand paper etc and including denting of broken / rusted surface and applied two coat of synthetic surface enamel paint by spray painting outside surface of panel as existing colour of panel all as specified and directed.
Servicing and repair/maint of ACB Switch upto 800 Amp 430 Volt alongwith tripping system and carried out the fwg repair/tests made for smooth operation. (a) Cleaning and greasing of mechanism, Operation, testing of trip and close electrical and manual mode, Spring charging testing electrical and manual mode, Cleaning of panel insulater CT &PT unit, (a) Service will be carried out through Service Engineer of Manfacturer /Authorised Service Engineer only. (b) The cost of minor spare parts i.e nut and bolts, springs, grommets, clips, pin etc essentially required to make the breaker serviceable shall be deemed to be included in the quoted rate.
Material & labour for restrainging ACSR conductor HT/LT providing suitable proper sag all as specified and directed.
supply and fixing in replacement of ACB 630 Amp gear box with tripping gear machanisam including all minor parts for repair of the ACB complete all as specified directed
Supply laying in replacement & testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (Heavy duty_) LT 1100 volt grade with stranded aluminium conductor of size 95 sqmm 3.5 core complete all as specified and directed.
Supply and fixing out door type , polymer , triple pole, 11000 volts mechanically operated Air break switch, mounted on 15 Nos insulators and steel frame, with operating mechanism worked from ground level for current rating up to 200 amps and all accessories ie pipe clamp etc complete, all as specified and directed.
M&L for HT lightening arrestor for outdoor use, expulsion type, POLYMER complete with all fittings, transmission class, discharge capacity 65kilo amps, minimum working pressure 11000volts grade conforming to IS complete all as specified and directed .
S & F in replacement of guard wire with galvanised steel wire 4mm dia for HT/LT OH line complete all as specified and directed by Engineer-In-charge.
M&L for earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried in ground vertical to a depth not less than 2.25 mtrs deep below ground level with top edge of plate not less than 1.5 mtr below normal ground level connected to galvanized GI strip of size 32 X 6 mm and 40 mm dia bore 7.5 mtr long light grade GI protection pipe for earth strip and GI watering pipe 40 mm dia medium grade from the top edge of earth plate fixed with deep cut on one end of pipe and fix from earth plate up to one feet above ground level of other end and plugged watering pipe at top with MS cap and grouted in PCC 1:2:4 of size 30 X 30 X 30 CM etc and 15 CM alternate layer of charcoal and salt around all sides of earth plate all as shown in electric plate no 3 of SSR part I of 2009. Note :- All joints either strip to strip of strip to earth plate are fixed with welded joints.
M&L for earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried in ground vertical to a depth not less than 2.25 mtrs deep below ground level with top edge of plate not less than 1.5 mtr below normal ground level connected to galvanized GI wire of size 4 mm dia and 15 mm dia bore 7.5 mtr long light grade GI protection pipe for earth strip and GI watering pipe 40 mm dia medium grade from the top edge of earth plate fixed with deep cut on one end of pipe and fix from earth plate up to one feet above ground level of other end and plugged watering pipe at top with MS cap and grouted in PCC 1:2:4 of size 30 X 30 X 30 CM etc and 15 CM alternate layer of charcoal and salt around all sides of earth plate all as shown in electric plate no 3 of SSR part I of 2009.
Supply and fixing in replacement of male female contacts of gang operative switch made out of brass and rated capacity 200 amps ,make matching with the existing switch complete all as specified and directed .
Supply and fixing in replacement of copper ribbon suitable for 200 amps rated capacity gang operative switch, 45 CM long complete all as specified and directed .
M&L for highly resistant insulating rubber mat suitable for 11 KV , Class B, 2.5mm thick complete all as specified and as directed
M&L for grease suitzable for 11 KV equipment complete all as specified and as directed by Engr-in-Charge
S&F in replacement HRC fuse suitable for VCB 630 Amp , 11 KV compete all as specified and as directed.
S&F in replacement air break switch insulator , 200 Amp , 11 kv complete all as specified and as directed.
S&F in replacement spindle suitable for 11 kv Pin insulator complete all as specified and as directed.
Supply & fix in replacement of LED security Light Luminaire 25 watt 6000K with .high power LED cool white, supply voltage 220/240/50 Hz, light engine driver base.pole adapter,powder coated pressure die cast aluminium with heat resistant toughened glass with lens complete all as specified and directed.
Supply laying in replacement & testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (Heavy duty_) LT 1100 volt grade with stranded aluminium conductor of size 70 sqmm 3.5 core complete all as specified and directed.
Material and labour for PCC 1:4:8 type D-2 using 40mm graded broken stone aggregate as in mass concrete in foundation of poles complete all as soecified.
Material and labour for PCC 1:3:6 type D-2 using 20mm graded broken stone aggregate as in mass concrete in foundation of stays complete all as soecified.
Supply and fixing in replacement of HT underground cable XLPE insulated PVC bedded, galvanised steel strip armoured electric power cables (heavy duty) with stranded aluminium conductor 11000 volts grade cross sectional area 185 sqmm 3 core laid in duct / trench/along pole etc including making connection complete all as specified and directed.
Supply and laying un-reinforced precast concrete cable cover factory made, class HV, type I, flat of size 300mm x 180mm x 40mm complete all as specified and directed.
Supply and fixing in replacement LED type street light fitting pressure die cast aluminium housing(Heat sink)for effective thermal management,sturdinessexcellent corrosion resistant IP 66,Operating Voltage 140-270 Volts, PF (0.95),Assemetric Lens Type-1,No. of LEDs=24 Nos,Luminous Flux >5000Lm,Efficacy of LED > 130 Lm/W,Beam Angle 153x107,LED driver current > 750 mA,Surge Voltage Protection (ref IEC61000-4-13 )of luminaires 90 watt LED 5700K complete fitting.
Taking out carefully manually by excavation of existing cable with loops and relaying with DWC pipe the same after repair of cutting the damages / burnt parts of cable and reconnecting its into original positions complete with cable joints all as specified and directed by Engineer-in-Charge.Note:-(i) HT/LT Cable Joint & DWC Pipe will be measured and paid sepearetly. (ii) Unit rate shall be included in excavation and returning filling.
S&F in replacement 70sqmm HT 11KV single core heavy duty insulated cable from top disc insulator to GOD and disc to disc in any lenth as jumper wire with complete nuts & thimbles all as required at site.
Supply & fixing in replacement of MCCB Capacity 36 KA 4 pole 630 Amps adjustable thermal magnet to release type with preader and aluminium lugs all as required at site.
All as per item 69 here in before but 500 Amp 36 KA
All as per item 69 here in before but 400 Amp 36 KA
All as per item 69 here in before but 250 Amp 36 KA
All as per item 69 here in before but 350 Amp 36 KA
All as per item 69 here in before but 200 Amp 25 KA
All as per item 69 here in before but 160 Amp 16 KA
M & L in replacement of out door type aluminuam bus bar chamber feeder box of cap 300 Amp , 3 phase, 4 wire, 415 Volts with porcelain insulator of size 90 x 60 x 45 cm made out of 3.15 mm CRCA Sheet duly painted with two coats of synthetic enameld paint over a red oxide primer and fixed and supported with anlge iron grouted in PCC 1:2:4 upto 0.45 mtr high from ground level and .30 mtr in the ground complete all as directed by Engr-In-Charge.
Material and Labour in replacement straight through joint heats shinkable suitable for upto 50 sqmm LT 3.5 core 1100 volts XLPE cable type complete all as specified and directed.
Material and Labour in replacement straight through joint heats shinkable suitable for 70 sqmm to 120 sqmm LT 3.5 core 1100 volts XLPE cable type complete all as specified and directed.
Material and Labour in replacement straight through joint heats shinkable suitable for 185 sqmm to 300 sqmm LT 3.5 core 1100 volts XLPE cable type complete all as specified and directed.
Material & labour for cleaning away all grass vegetation, scapling shrubs bushes under grouth roots and trees not exceding 30 cm grith and removing rubbish upto distance of 50 mtr out the periphery of area under cleaness, existing foliage / grass will be uprooted by machinery / maually as per the requirement and safety of cables complete all as specified and directed.
S&F maintenance free battery suitable for power back up system at MES Power house ,12V , 180Ah complete all as specified and as directed by Engr-in-Charge.
S&F DC Power back min 2Hrs battery backup 24V DC including charging equipment suitable for 11KV 800Amp VCB operting system complete all as specified .
Prunning of trees of over head HT/LT lines by taking proper shutdown & removing the same from site upto a distance of 50 mtr all as directed by Engr in Charge.
Supply and replacement HT 11 KV bush rod suitable for indoor / outdoor type 250 to 315 KVA transformer complete with brass stud, brass nuts, brass cup and packing gasket complete all as spd and directed.
All as per Srl item No 84.00 here-in-before but suitable for 160 to 200 KVA transformer.
Supply and fixing in replacement thermoplastic polycarbonate cable junction boxes IP 55/ IP 65 of dimension 200x160x98mm with metric Knockouts for cable entry with five terminals and cable glands with lock nuts light grey RAL suitable for 16/25 Sqmm UG Cable Complete all as specified and directed By Engineer-in-Charge.
M&L for finding the fault in LT/ HT UG Cable with cable fault locator and removing the fault duly filling joint complete make the UG cable in serviceable condition all as speficied and as directed. Note:- Excavation work for the same will be measured and paid seperately.
M&L for taking out the old defective LT / HT Cable and finding the fault and relaying the same after repair/ jointing all as specified and as directed. Note Excavation, jointing kit shall be measured and paid seperately.
Supply and Fix high grade PVC HT overhead phase to phase line spacer suitable for 2-3 lines , suitable for verticale and horizontal line complete all as specified and as directed.
Supply and Fix high grade PVC LT overhead phase to phase line spacer suitable for 3 lines , suitable for verticale and horizontal line complete all as specified and as directed.
Supply and Fix high grade PVC LT overhead phase to phase line spacer suitable for 5 lines , suitable for verticale and horizontal line complete all as specified and as directed.
Supply and fixing in replacement aluminium thimble of size 50 sqmm
Supply and fixing in replacement aluminium thimble of size 95 to 120 sqmm
Supply and fixing in replacement aluminium thimble of size 185 to 240 sqmm
Supply and fixing in replacement aluminium thimble of size 300 to 400 sqmm
Supply and laying or fixing in replacement 1100 Volts grade heavy duty cable with PVC insulated aluminium standard conductor served with an inner sheathing of PVC tape and over all PVC Sheathed in service connections , one twin core 10 Sqmm cable standard conductor cable flat or circular all as specified and directed by Engineer- in- Charge.
Supply and laying or fixing in replacement 1100 Volts grade heavy duty cable with PVC insulated aluminium standard conductor served with an inner sheathing of PVC tape and over all PVC Sheathed in service connections , one twin core 16 Sqmm cable standard conductor cable flat or circular all as specified and directed by Engineer- in- Charge.
Supply and fixing in replacement bracket made out of GI pipe 50/ 40 mm medium grade 1.2 mtr long made to shape with fixing clamps of MS flat 40x6mm nut bolts etc for street light all as specified and directed
Material & labour for 2 Pole structure complete painting to mild steel cross arms, bracing, supports, clamps, back plate etc fixed on HT Poles any height with providing two coats of aluminium paint over a coat one coat of red oxide primer complete all as specified and directed. Note:- One 2 pole mild steel struture complete on HT PCC pole steel members fixed thereon shall be considered as 'One Unit'.
Painting of PCC poles with two coats of synthetic enamel paint in black and white strip 30 cm wide each up to 1.5 mtr height from coping ovdirer a coat of primer including Numbering of poles as directed by Engr-in-Charge
Shifting of transformer from one place to other place within the cantt area including disconnecting / reconnecting all connection any time any capacity including transportation and lifting/ fixing arrangement within cantt area complete all as directed by Engr in charge.
Supply only in replacement Barrel type 11000 KV fuse wire of 2.5 Amp to 40 Amp rating complete all as specified and directed.
Material and labour in replacement of LT fire resistant PVC self adhesive electrical insulaion tape (Red, Yellow, Blue & Black) high quality size minimum 7 mtr long x 1.8 CM width complete.
Material and labour in replacement for HT fire resistant, flame retardant self adhesive electrical insulaion tape suitble for 11KV , high quality size minimum 19mm x 60 Ft complete.
Mahajan Builder
Kaul Enterprises
M/S JAI ENGINEERS & CONTRACTORS
Santokh Singh and Associates
Bharat Builder
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .