| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.1 LAccepted-AOC 5 5 313A S D LAYOUT TIRUPATHI ANDHRA PRADESH | TIRUPATHI | ANDHRA PRADESH | L1 | Accepted-AOC Accept | |
| 2 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification | |
| 3 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹54 L
EMD Value
₹54,000
Closing Date
20 Sept 2024, 3:00 pmClosed
The Commissioner
Municipal office, Chinnamanur, Theni Dist
Operation and Maintenance Deficit Grant Fund 2024-25-Supply, Delivery and Erection of 250 HP Motor, Vaccum Pumpset, VFD DRIVE Panel , HOT Crane- 5 Tonne Capacity, Electrimagnetic Flow Meter and NRV at Pump Room in Chinnamanur Municipality, Theni Dis
2024_MAWS_481084_1
1948/2024/E1
Open Tender
Civil Works
Works
90 days
Municipal Town Limit, Chinnamanur
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹54,000
Municipal office, Chinnamanur, Theni Dist
4 Oct 2024
5 Sept 2024
20 Sept 2024
5 Sept 2024
20 Sept 2024
10 Sept 2024
9 Sept 2024
Amount
Supply of 5 HP Model/ Rotary type Vaccumpumpsets (Pumpset + GI Pipes + Fittings+ Starters + Valves + 100L Tank)including Transportation, handlingcharges. (SOR Page No.127 / Item No. 13.0 / 24 - 25)
5T capacity hand operated over head Travelling (HOT) crane suitable for a span upto 6 Mtrs, and travel length upto 10 M with clear lift upto 6 M including gear type chain pulley block and geared Travelling trolley complete with all accessories including girder (SOR P.134 / Item No 21.0 / 7 / 24-25)
Electromagnetic Flow Meter shall be a velocity sensing Electromagnetic type, microprocessor based signal converter, sealed housing, flanged tube meter for 1.0 Mpa working pressure, manufactured to highest standard available for mag-meters, equipped with minimum six digit digital totalizers, reading in different units (Kiloliters / Cubic meter) and shall be accurate within 0.5% of Measured value, shall operate within a range of 0.3 m/sec to 4 m/sec and be constructed as follows: Meter tube (Sensor) shall be fabricated from stainless steel tube and use class PN10 flat face carbon steel flanges in accordance with IS 1538. These flanges shall be welded to the flow tube. The internal and external of the meter tube shall be blasted to near white and lined with hard rubber/ Polyurethrene/ PTFE preferably by SBR or EPDM. Meter tube shall have a constant nominal inside diameter offering no obstruction to the flow. The accuracy should be inclusive of linearity, hysteresis, repeatability, temperature and pressure effects. Coil Housing shall be fabricated from stainless steel (SS304)/ Die cast Aluminium/ Carbon steel with anticorriosive paint for corrosion resistance and welded to the tube providing a completely sealed environment for all coils, electrode connections and wiring harness capable of submerged or buried operation with IP68 Protection. Signal Converter shall be pulsed DC coil excitation type with auto zeroing. The signal converter shall be remotely mounted away from the meter.
The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions. The converter shall provide an isolated 4-20 mA output into minimum 500-ohm load and a frequency output of a maximum of 0-10 KHZ and a scaled pulse output. The microprocessor based signal converter shall have a self-diagnostic test mode and a backlit display that continuously displays “Rate of Flow” and “Total Volume”. Converter shall be supplied with a programmable low flow drop out, higher flow and empty pipe zero return. The signal converter housing should be die-cast aluminum with glass window. The converter cum transmitter should be fully programmable from the front facia. The programming should be user friendly, self-prompting menu driven. Flow meter test calibration certificate from FCRI, flow test lab / NABL accredited lab to be furnished.(TWAD PG NO.85 / 16.6 / 10 (24-25))
Supply, delivery, erection, testing and commissioning of 200KW / 377 Amps Capacity VFD DRIVE Panel with input ac Choke etc, complete with incidental of folloeing and as per Specifications & Drawings. The panel shall be poeder coated as per specfication. (Quotation)
Manufacture, Supply and Delivery of DI D/F Slanted seat Swing Check Valve. Body of ductile cast iron of Grade GGG 40 or equivalent grade and disc of ductile cast iron GGG 40 or equivalent grade with fully encapsulated EPDM rubber, where both faces can be used. Electrostatic epoxy powder/liquid coating (EP-P) inside and outside color blue RAL 5005 with minimum coating thickness of 250 microns. The EPDM rubber & Epoxy Powder should be approved by W 270. (EP-P) it is a resi-coat powder approved for drinking water application, applied through fusion bonding process by dipping the shot-blasted casted components heated up to 200 deg C). Face to face dimensions as per EN558-1, series 48 and flange connections as per EN 1092-2/IS 1538 (SOR P.68 / Item No 12.11.10 / 24-25)
HORIZONTAL SQUIRREL CAGE MOTOR 1500 RPM - AC three Phase /415 V/ Horizontal SPDP 4 Pole Squirrel cageInduction motor for HSC Centrifugal pumps Supply and delivery of AC three Phase 4 pole Horizontal squirrel cage Induction motor confiriming to IS 325/1996 and as amended thereafter with Class F insulation to suit the speed of pump and suitable for operation withcontino us S1 rated, 415 V +/- 10 %, 50 HZ +/- 5%, TEFC (upto 20 HP), SPDP(above 20 HP). The motor offered should be of energy efficient motors. 7000 LPM x 80M Head (SOR Page No.112, Item No.5/8 - 2024-25).
Labour Charges for erection of Horizontal shaft, centrifugal pumpset (Coupled/Monoblock) in bore well/Open well including fixing of suction pipe and foot valve upto a maximum depth of 7 metres and delivery pipes to the required length with valves, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPIC switches starter, Voltmeter, Ammeter, Capacitor single phasing preventor and laying and jointing the cables and twin earthing as per IE rules including providing bed blocks etc., complete and operating the pumps and trial run for 10 days including signing of completion of reports as required by EB authorities. (Quotation)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .