Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.2 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹27.3 L+₹29,827.70 (1.11%)Rejected-Finance | L2 | Rejected-Finance HIGH RATE | |
| 3 | L3₹29.9 L+₹2.9 L (10.7%)Rejected-Finance | L3 | Rejected-Finance HIGH RATE | |
| 4 | L4₹30.7 L+₹3.7 L (13.7%)Rejected-Finance 16 B DR AMBEDKAR ROAD SAROSH APARTMENTS PUNE 411001 | PUNE | MAHARASHTRA | 411001 | L4 | Rejected-Finance HIGH RATE | |
| 5 | L5₹32.2 L+₹5.2 L (19.4%)Rejected-Finance | L5 | Rejected-Finance HIGH RATE |
| Sl No | Description | Qty | Unit | SANDHYA ENTERPRISES L2 | SONU ENTERPRISES L3 | Monarch Sales Corporation L1 | M/S CHANDAN BUILDERS L4 | ADITYA LAXMAN PASALKAR L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Repair / maintenance of internal light fitting of any type like tube lights / wall bracket light fittings / ceiling lights / bulk head light / mirror lights etc in its position, testing all the compenents / parts, wiring etc, identifying and replacing the defective components like tube rod, side holders, holders, lamps etc all as specified and directed .
Note: (i) The rate against the above mentioned item is deemed for cost of labour only.
(ii) Cost of spares like capacitor, lamp holder, connector, connection wire etc. replaced against above mentioned item will be measured & paid separately under respective items of Sch 'A' here-in-below. (iii) The contractor's representative (supervisor) will report to concerned JE E/M at 0900hrs daily to collect the list of complaints and will submit the completion report on the same day before 1700hrs to the JE E/M.
(iv) The contractor shall address all the given complaints within 24 hours from the time the list of complaints is handed over to him / his rep by the concerned JE E/M. In case the complaint is not addressed for whatsoever reason within the specified time limit (48 hrs), an amount of Rs 100/- per such complaint per day will be recovered from the amount due to him through RAR / Final Bill.The contractor shall engage separate team of technicians / repairer for each at SQN AREA B Zone (04 x teams).
(v) The contractor shall maintain proper record of repair / maint in a binded compliant register and complaint slip books duly signed by the user and bringing out the details of spares replaced and get it authenticated from concerned JE E/M on daily basis. The contractor shall put up the maint record register to Engineer-in-charge for inspection every Monday or as and when asked for.
(vi) The contractor shall maintain sufficient stock of spares / material required for repair / maint of light fittings with the concerned JE E/M against the supply only items here-in-below. (vii) During the contract period, if the same complaint is repeated, it will be regarded as a single complaint, and no additional payment will be made for addressing the repeated issue. | 1,400 | Each | 292 ₹4,08,800 | 40 ₹56,000 | 25 ₹35,000 Lowest | 50 ₹70,000 | 50 ₹70,000 |
| 2.00 | Supply only PVC / polycarbonate lamp holders batten/Angle type all as specified and directed | 200 | Each | 15 ₹3,000 Lowest | 30 ₹6,000 | 20 ₹4,000 | 20 ₹4,000 | 30 ₹6,000 |
| 3.00 | S & F in repair of switch piano flush type 6 Amps SP one way all as specified and directed | 200 | Each | 15 ₹3,000 Lowest | 21 ₹4,200 | 15 ₹3,000 Lowest | 20 ₹4,000 | 40 ₹8,000 |
| 4.00 | S & F in repair of switch piano flush type 6 Amps SP two way all as specified and directed | 10 | Each | 35 ₹350 | 28 ₹280 | 20 ₹200 Lowest | 35 ₹350 | 60 ₹600 |
| 5.00 | M&L in repair bell push, flush type 6 Amps all as specified and directed. | 10 | Each | 30 ₹300 | 27 ₹270 | 18 ₹180 Lowest | 20 ₹200 | 60 ₹600 |
| 6.00 | M&L in repair of pendent (Bed) switch 6 amps single phase all as specified and directed. | 10 | Each | 30 ₹300 | 25 ₹250 | 20 ₹200 Lowest | 35 ₹350 | 60 ₹600 |
| 7.00 | S&F in repair of socket 5/6 Amps flush mounted 5 pin all as specified and directed | 100 | Each | 30 ₹3,000 Lowest | 30 ₹3,000 Lowest | 100 ₹10,000 | 60 ₹6,000 | 80 ₹8,000 |
| 8.00 | S & F in repair of switch socket combination 5/6 Amps flush mounted 5 pin multi purpose all as specified and directed | 50 | Each | 40 ₹2,000 Lowest | 90 ₹4,500 | 140 ₹7,000 | 80 ₹4,000 | 90 ₹4,500 |
| 9.00 | S & F in repair of switch socket combination with box of 5/6 Amps flush mounted 5 pin multi purpose all as specified and directed | 100 | Each | 60 ₹6,000 Lowest | 120 ₹12,000 | 125 ₹12,500 | 120 ₹12,000 | 150 ₹15,000 |
| 10.00 | M&L in replacment of fan regulator switch/socket type electronic step type suitable for 1200/1400 mm sweep fan as per the sample provided all as specified and directed | 80 | Each | 110 ₹8,800 Lowest | 190 ₹15,200 | 160 ₹12,800 | 300 ₹24,000 | 200 ₹16,000 |
Tender Value
₹35.0 L
EMD Value
₹70,000
Closing Date
25 Aug 2025, 6:00 pmClosed
GE Khadakwasla
GE Khadakwasla
REPAIR/ MAINT OF INTERNAL ELECTRIFICATION INCLUDING FANS AND GEYSERS AT CADET LIVING ACCN AT NDA KHADAKWASLA
2025_MES_723139_1
8973/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE Khadakwasla
As per tender docuemnts
9 documents required · 9 mandatory
₹500
GE Khadakwasla
₹70,000
Yes
10 Oct 2025
29 Jul 2025
27 Aug 2025
29 Jul 2025
25 Aug 2025
12 Aug 2025
29 Jul 2025 - 12 Aug 2025
Amount
Repair / maintenance of internal light fitting of any type like tube lights / wall bracket light fittings / ceiling lights / bulk head light / mirror lights etc in its position, testing all the compenents / parts, wiring etc, identifying and replacing the defective components like tube rod, side holders, holders, lamps etc all as specified and directed . Note: (i) The rate against the above mentioned item is deemed for cost of labour only. (ii) Cost of spares like capacitor, lamp holder, connector, connection wire etc. replaced against above mentioned item will be measured & paid separately under respective items of Sch 'A' here-in-below. (iii) The contractor's representative (supervisor) will report to concerned JE E/M at 0900hrs daily to collect the list of complaints and will submit the completion report on the same day before 1700hrs to the JE E/M. (iv) The contractor shall address all the given complaints within 24 hours from the time the list of complaints is handed over to him / his rep by the concerned JE E/M. In case the complaint is not addressed for whatsoever reason within the specified time limit (48 hrs), an amount of Rs 100/- per such complaint per day will be recovered from the amount due to him through RAR / Final Bill.The contractor shall engage separate team of technicians / repairer for each at SQN AREA B Zone (04 x teams). (v) The contractor shall maintain proper record of repair / maint in a binded compliant register and complaint slip books duly signed by the user and bringing out the details of spares replaced and get it authenticated from concerned JE E/M on daily basis. The contractor shall put up the maint record register to Engineer-in-charge for inspection every Monday or as and when asked for. (vi) The contractor shall maintain sufficient stock of spares / material required for repair / maint of light fittings with the concerned JE E/M against the supply only items here-in-below. (vii) During the contract period, if the same complaint is repeated, it will be regarded as a single complaint, and no additional payment will be made for addressing the repeated issue.
Supply only PVC / polycarbonate lamp holders batten/Angle type all as specified and directed
S & F in repair of switch piano flush type 6 Amps SP one way all as specified and directed
S & F in repair of switch piano flush type 6 Amps SP two way all as specified and directed
M&L in repair bell push, flush type 6 Amps all as specified and directed.
M&L in repair of pendent (Bed) switch 6 amps single phase all as specified and directed.
S&F in repair of socket 5/6 Amps flush mounted 5 pin all as specified and directed
S & F in repair of switch socket combination 5/6 Amps flush mounted 5 pin multi purpose all as specified and directed
S & F in repair of switch socket combination with box of 5/6 Amps flush mounted 5 pin multi purpose all as specified and directed
M&L in replacment of fan regulator switch/socket type electronic step type suitable for 1200/1400 mm sweep fan as per the sample provided all as specified and directed
S & F in repair of switch piano type 20 Amps SP one way all as specified and directed
S&F in repair of socket 5/15 Amps flush mounted 3/5 pin multi purpose all as specified and directed
S & F in repair of switch socket combination with box of5/15 Amps flush mounted 3/5 pin multi purpose all as specified and directed
S&F in repair for ceiling rose, 2 to 3 terminals /PVC/Polycarbonate, isolated body all as specified and directed.
S&F inrepair plug top 3 pin, 6 amps, 230 volts, ISI marked heavy duty connection cord all as specified and directed.
S&F in repair plug top 3 pin, 15/16 amps, 230 volts, ISI marked heavy duty for geyser connection cord all as specified and directed.
S&F in repair plug top 2 pin, 6 amps, 230 volts, ISI marked heavy duty connection cord all as specified and directed.
S&F in repair metal clade sockets 20 amps, 230 volts, ISI marked heavy duty connection cord all as specified and directed.
S&F in repair metal clade plugs 20 amps, 230 volts, ISI marked heavy duty connection cord all as specified and directed.
M&L in repair of door bell AC 230 volts single phase ding dong type all as specified and directed.
M&L in repair of wire less door bell AC 230 volts single phase ding dong type all as specified and directed.
S&F in repair modular switch piano type 10 amps one way one module all as specified and directed
S&F in repair modular switch piano type 10 amps two way one module all as specified and directed
S&F in repair modular Bell push, 10 Amp with neon indicator one module all as specified and directed
S&F in repair modular switch piano type 20 amps one way one module with neon indicator all as specified and directed
S&F in repair modular Socket, 6A - 2/3 pin 2 module all as specified and directed
S&F in repair modular Socket, 6/16A - 2/3 pin 2 module all as specified and directed
S&F in repair of 1 module Blanking plates complete all as specifed and directed
S&F in repair modular step type fan regulator 100W, 1/2 module all as specified and directed
S&F in repair for white cover plate with frame 1 or 2 module all as specified and directed.
S&F in repair for white cover plate with frame 3 module all as specified and directed.
S&F in repair for white cover plate with frame 4 module all as specified and directed.
S&F in repair for white cover plate with frame 6 module all as specified and directed.
S&F in repair for white cover plate with frame 8 module all as specified and directed.
S&F in repair for white cover plate with frame 12 module all as specified and directed.
S&F in repair for white cover plate with frame 16 module all as specified and directed.
S&F in repair for white cover plate with frame 18 module all as specified and directed.
S& F in repair PVC unbreakable surface boxes suitable for modular switches 1 or 2 module all as specified and directed.
S& F in repair PVC unbreakable surface boxes suitable for modular switches 3 module all as specified and directed.
S& F in repair PVC unbreakable surface boxes suitable for modular switches 4 module all as specified and directed.
S& F in repair PVC unbreakable surface boxes suitable for modular switches 6 module all as specified and directed.
S& F in repair PVC unbreakable surface boxes suitable for modular switches 8 module all as specified and directed.
S& F in repair PVC unbreakable surface boxes suitable for modular switches 12 module all as specified and directed.
S& F in repair PVC unbreakable surface boxes suitable for modular switches 16 module all as specified and directed.
S& F in repair PVC unbreakable surface boxes suitable for modular switches 18 module all as specified and directed.
S&F in repair for squre box, 2 to 3 terminals /PVC/Polycarbonate, isolated body all as specified and directed.
S&F in repair for round plate, 2 to 3 terminals /PVC/Polycarbonate, isolated body all as specified and directed.
S&F in repair of PVC insulated copper cable 1 Sqmm 3 core, served with inner sheathing of PVC tape and overall PVC sheathed including PVC Conduit ISI Marked 20mm including all necessary bends, couplings, tees, and other accessories.Surface Saddling of PVC Conduit on Wall using approved saddles and fixing screws. Spacing as per specifications ( 1-meter intervals).all as specified and directed
Ditto all as per item no.48 above but 2,5 Sqmm 3 core
Ditto all as per item no.48 above but 4 Sqmm 3 core
Supply only 9 W WW LED Lamp for E14/E27/B22 Holders all as specified and directed.
Supply only 5 W WW LED Lamp for E14/E27/B22 Holders all as specified and directed.
Supply only 3 W WW LED Lamp for E14/E27/B22 Holders all as specified and directed.
Supply only 0.5 W WW LED Lamp for E14/E27/B22 Holders all as specified and directed.
S&F in repair of 10 watt,230V surface and wall mounted LED batten, extruded aluminium housing with polycarbonate diffuser and integrated electronic driver including connecting up with twin core twisted flexible copper condctor cable from ceiling rose all as specified and directed
S&F in repair of 20 watt,230V surface and wall mounted LED batten, extruded aluminium housing with polycarbonate diffuser and integrated electronic driver including connecting up with twin core twisted flexible copper condctor cable from ceiling rose all as specified and directed
S&F in repair of 20 watt,230V 3 IN 1 surface and wall mounted LED batten, extruded aluminium housing with polycarbonate diffuser and integrated electronic driver including connecting up with twin core twisted flexible copper condctor cable from ceiling rose all as specified and directed
S&F in repair of 20 watt,230V surface and wall mounted Inverter LED batten, automaticaily switched ON during a power cut and runs effiectively up to 3 Hrs, extruded aluminium housing with polycarbonate diffuser and integrated electronic driver including connecting up with twin core twisted flexible copper condctor cable from ceiling rose all as specified and directed
S&F in repair of 36 watt,230V surface and wall mounted LED batten, extruded aluminium housing with polycarbonate diffuser and integrated electronic driver including connecting up with twin core twisted flexible copper condctor cable from ceiling rose all as specified and directed
S&F in repalcement Surface type LED Downlight lights 10 W Environmental friendly, energy saving, recess mounted downlighter with electronic driver including connecting with twin core wire, including cutting the existing false ceiling dia to the required size and also matching to the adjacent false ceiling surfaces carefully all as specified and directed.
S&F in repalcement Surface type LED Downlight lights 12 W Environmental friendly, energy saving, recess mounted downlighter with electronic driver including connecting with twin core wire, including cutting the existing false ceiling dia to the required size and also matching to the adjacent false ceiling surfaces carefully all as specified and directed.
S&F in repalcement Surface type LED Downlight lights 30 W Environmental friendly, energy saving, recess mounted downlighter with electronic driver including connecting with twin core wire, including cutting the existing false ceiling dia to the required size and also matching to the adjacent false ceiling surfaces carefully all as specified and directed.
S&F in repalcement COB light 12W LED Tiltable surface mounting and Environmental friendly, new generation, energy saving, decorative IP 66 all as specified and directed. Make: Luker cat part no. LCOBSP12 or techno-commercially equivalent make as mentioned at list of makes in PS of CA
S&F inrepair LED building security light fiitting 30 W, IP-65 protection made up of die cast alluminium housing with high power LED as lighting source and lens embeded PC cover having TOP opening seperate driver compartment complete all as specified and directed . Make- Luker LST-24SEN or techno-commercially equivalent make as mentioned at list of makes in PS of CA
S&F inrepair of 12 watt,230V surface and wall mounted white LED Mirror Light including connecting up with twin core twisted flexible copper condctor cable from ceiling rose all as specified and directed . Make- Luker LIMR13 3-IN-1 or techno-commercially equivalent make as mentioned at list of makes in PS of CA
S&F inrepair of 9 watt,230V surface and wall mounted white LED Mirror Light including connecting up with twin core twisted flexible copper condctor cable from ceiling rose all as specified and directed
S&F inrepair Decorative wall mounting Wall Lamp with B22 LED 9W and connecting up with twin core twisted flexible copper conductor cable from ceiling rose all as specified and directed
S&F inrepair Decorative hanging table lamp with B22 LED 9W and connecting up with twin core twisted flexible copper conductor cable from ceiling rose all as specified and directed
S&F inrepair Decorative hanging with B22 LED 9W and connecting up with twin core twisted flexible copper conductor cable from ceiling rose all as specified and directed
S&F in repalcement surface/recess mounted 2' x 2' LED Panel lights 40 W LED 5700K, 240Volts and glare free symmetrical illumination suitable for Armstrong/Grid ceiling, Environmental friendly, new generation, energy saving, high power LED as a light source with clear diffuser and separate replaceable electronic driver including connecting with twin core wire and also matching to the adjacent ceiling surfaces carefully all as specified and directed. Note: The quoted price shall include the cost of Light and its driver.
S&F in repalcement surface/recess mounted 4' x 1' LED Panel lights 45 W LED 5700K, 240Volts and glare free symmetrical illumination suitable for Armstrong/Grid ceiling, Environmental friendly, new generation, energy saving, high power LED as a light source with clear diffuser and separate replaceable electronic driver including connecting with twin core wire and also matching to the adjacent ceiling surfaces carefully all as specified and directed. Note: The quoted price shall include the cost of Light and its driver.
S&F inrepair of GI pipe bracket of 25 mm dia 1 mtr long bend to shape for street light fitting made out of 25 mm dia GI light grade pipe fixed on building/pole using suitable FI clamp including necessary new nut, bolt and washer complete all as specified and directed.
Supply and Fix ofrepair Electronic Drivers, suitable for 9W, 10W, 20W, 30W, and 40W LED light/security light fittings, of compatible specifications and make as existing, including all necessary connections, testing, and commissioning, complete as specified and directed
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.complete as specified and directed
M&L point wiring with 1.5 sq mm copper conductor FRLSH (multistrand) PVC insulated ISI marked unsheathed cable and including surface, Non metalic rigid PVC casing capping double lock type/PVC conduit ISI marked not less than 25 mm with all fitting & other accessories and also including PVC insulated ISI marked unseathed FRLSH cable size 1.5 sq mm copper conductor as earth wire to common earth dolly including PVC box, modular cover plate with frame suitable for modular type switches, sockets, fan regulator etc complete as specified and directed for following :- (a) One light/Fan point controlled by one way switch 6 Amps 240 volts
(b)Ditto all as per item no.75 above but One 3 pin 6 Amps socket out let point on independent board.
(c)Ditto all as per item no. 75 above but One 3 pin 6 Amps socket out let point on same board.
(d)Ditto all as per item no. 75 above but One bell/buzzer point controlled by one push button on the same board with other switches or independent with cables 1.5 sq mm size.
(e)Ditto all as per item no. 75 above but One light point controlled by Two 2-way switches
M&Lrepair of point wiring with 2.5 sq mm copper conductor FRLSH (multistrand) PVC insulated ISI marked unseathed cable and including surface, Non metalic rigid PVC casing capping double lock type ISI marked not less than 25 mm with all fitting & other accessories and also including PVC insulated ISI marked unseathed FRLSH cable size 2.5 sq mm copper conductor as earth wire to common earth dolly including PVC box , modular cover plate with frame suitable for 15 Amps socket and switch outlet power point independent circuit
Supply and fixing in repair of rigid non-metallic PVC casing capping, double lock type/PVC conduit (ISI marked) of size not less than 25mm, including all necessary accessories (e.g., bends, elbows, connectors, saddles, screws,round plate etc.) for securing loose wiring and repairing/re-routing point wiring and submain wiring, complete as specified and directed . Note The unit rate shall includes the following: a) Supply of 25mm or larger rigid non-metallic PVC casing capping/conduit (ISI marked). b) Supply of all necessary accessories (bends, elbows, connectors, saddles, screws, etc.). c )Securing loose wiring within the casing/conduit. d) Repairing/re-routing existing point wiring/submain wiring as needed. e) Making necessary connections and terminations. f) Testing of the wiring after completion. Notes:Rates shall include the cost of all materials, labor, tools, equipment, transportation, and any other incidental expenses required for the complete execution of the work.
supply and installation of flexible conduit pipes, ivory grey,white in colour, with a minimum internal diameter of 25mm. The conduit shall be of a type suitable for [Specify application, e.g., electrical wiring, data cabling, etc.]. Installation includes cutting, bending (where necessary), and securing the conduit as per the approved design and engineer-in-charge instructions complete as specified and directed.
Supply and fixing in repair of rigid non-metallic PVC cable tray , double lock type (ISI marked) of size not less than 80x40mm, including all necessary accessories (e.g.,Bends (flat, internal, external),Risers,Couplers,Dividers,Support brackets, elbows, connectors, saddles, screws,round plate etc.) for securing loose wiring and repairing/re-routing point wiring and submain wiring, complete as specified and directed . Note: The unit rate shall includes the following: a) Supply of 80x40mm or larger rigid non-metallic PVC cable tray. b) Supply of all necessary accessories (Bends (flat, internal, external), Risers, Couplers, Dividers, Support brackets, elbows, connectors, saddles, screws,round plate etc.. c )Securing loose wiring within the cable tray. d) Repairing/re-routing existing point wiring/submain wiring as needed. e) Making necessary connections and terminations. f) Testing of the wiring after completion. Notes:Rates shall include the cost of all materials, labor, tools, equipment, transportation, and any other incidental expenses required for the complete execution of the work.
Taking down Careful dismantling and removal of existing sub-main wiring, including cables, conduits, trunking, and all associated fixtures, regardless of type and size.This includes all necessary materials and labor to restore the surfaces to their original condition, or to an agreed upon condition.All work shall be carried out in accordance with the Engineer-in-charge's instructions and any relevant project specifications.If the wiring is to be salvaged, great care must be taken during removal complete as specified and directed.
M&L sub main wiring with two single core PVC insulated FRLSH cables with stranded copper conductors 1.5 Sqmm , 1100 Volts grade in and including PVC Conduit/casing caping medium grade not less than 25 mm complete with conduit accessories and copper cable 1.5 sqmm continuous earth wire complete all as specified and directed Note:Two runs of 1.5 Sqmm cable with 01 run of 1.5 Sqmm earth wire along with casing caping/conduit shall be measured as one RM
Dittto all as per item no 85 above 2 x 2.5Sqmm
Dittto all as per item no 85 above 2 x 4 Sqmm
Dittto all as per item no 85 above 2 x 6 Sqmm
Dittto all as per item no 85 above 2 x 10 Sqmm
S&F inrepair factory made epoxy powder coated Distribution Board TP & N 4 way double door (VTPN MCCB DB ) MCCB as In comer, with metal door (IP-43 protection) fabricated from CRCA sheet and fixed semi flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates with Knockout semi flush to wall and making good disturbed surface and touch up with the same finishes complete all as specified and directed Note:MCBs/ MCCBs will be measured and paid seperately under respective Sch A item in the schedule
S&F inrepair MCB DB 12 way SPN double door sheet metal enclosure factory made suitable for MCB DB's 240 volts with 200 amp rated busbar, neutral & earthing link bar,surface mounting complete including taking down the existing DB of any type & size alongwith its accessories by removing from existing circuits and refixing the new DBs and circuits complete as reqd at site as directed . Note - MCBs will be measured & paid separately under respective item of sch A, if required to be replaced.
Dittto all as per item no 91 above but 08 way SPN DB (Double door)
Dittto all as per item no 91 above but 04 way SPN DB (Single door)
Dittto all as per item no 91 above but 04 way SPN DB (Double door)
Dittto all as per item no 91 above but 02 way SPN DB (Single door)
S&F in repair of MCCB with rating of 100 Amps,415Volts 3pole with 16kA breaking capacity,thermal magnetic asdjustable of overload & short circuit release as per IS-13947 & IEC 60947-2 & the service short circuit breaking capacity (Ics) should be equal to ultimate breaking capcity(Icu).MCCB should be with suitable spreaders and phase barriers for each terminals complete as specified and directed.
Dittto all as per item no 96 above but MCCB with rating of 125 Amps,415Volts 3pole with 16kA breaking capacity
S&F inrepair of C Curve MCB SP 6-32 Amps working on 240 volts,50 Hz 10 KA all as specified and directed.
S&F inrepair of C Curve MCB DP 6-32 Amps working on 240 volts,50 Hz 10 KA all as specified and directed.
S&F inrepair of C Curve MCB SPN 40-63 Amps working on 240 volts, 50 HZ,10 KA all as specified and directed.
S&F inrepair of C Curve MCB TP 40-63 Amps working on 240 volts, 50 HZ,10 KA all as specified and directed.
Supply and fix inrepair of C Curve MCB TPN 40-63 Amps working on 240 volts, 50 HZ,10 KA all as specified and directed.
S&F inrepair sheet metal enclosures Single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB 20 Amps, 240 volts complete with all accessaries etc complete as specified and directed
S&F inrepair sheet metal enclosures Triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB 32 Amps, 240 volts complete with all accessaries etc complete as specified and directed
M&L in repair of earthing complete with galvanised steel earth plate electrode 600x600x6.3mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia of minimum 15m length by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 in SSR PART-I connected to earthing test point all as specified or indicated including provision of earthing lead protection pipe, PCC earth pit with cover, excavation & earth work, testing on completion etc all as specified and directed
Dismantling and removing rusted louvers suitable for 150/230/300/450/600 mm sweep exhaust fan S&F inrepair of MS louvers duly painted gray coloured suitable for 150/230/300/450/600 mm heavy duty exhaust fan alongwith four number mounting bracket with bolts, nuts washers etc complete as specified and directed
S&F in repair of GI pipe ceiling fan down rod of 15 mm dia up to 3 feet long for ceiling fan made out of 15 mm dia GI heavy grade pipe fixed on ceiling using suitable clamp including necessary new nut, bolt and washer complete all as specified and directed.
Taking down ceiling fan/exhaust fan of any sweep for servicing / repairing / maintenance, opening up, identifying and replacing the defective parts, cleaning, greasing,etc, reassembling and hanging up/fixing back at its original position, connecting up and testing complete all as directed.
Supply only capacitor of 2.5/4 mfd for ceiling fan/exhaust fan. Make:Tibcon/Epcos/Havells
Supply only bearing No.6201/6202/6203 or any other No matching to the existing size and suitable for exhaust fan/wall mounted fan. Make:SKF or equivalent
Disconnecting and taking down existing userviceable geyser of 25/50/100 ltrs capacity of any make/brand, taking it to civil workshop for repairing. Opening the geyser and dismanting all parts and taking out inner tank/container, removing dents making to shape including welding / brazing the leakage portion, filling the portion between inner tank and out casing of geyser with new glass wool heat insulating material . Reassembling and painting the outer casing of geyser with two coats of superior quality synthetic enameled paint and re- fixing to original place all as directed . Note : 1.Cost of spares such as Thermostate,heating element etc shall be measured and paid for separately under respective Item of sch A as supply only.
Supply only thermostat and cutout set electronic type, temperature adjustable from 0-80⁰C suitable for geyser of 25 to 100 ltrs capacity complete as specified and directed.
Supply only heating element of capacity 2/3 KW of any type and shape suitable for Existing 25 to 100 ltrs capacity geysers as per sample provided complete as specified and directed
S&F in repair metallic flexible hot water connection 600/900 mm long including necessary washers suitable for geysers of 25 to 100 ltr capacity complete all as specified and directed.
S&F in repair of neon lamp indicator square/round type after taking out old incl taking down old one complete as specified and directed.
S&F in repair NRV valve of size 15mm dia of Brass complete all as specified and directed.
Removal of the damaged or faulty inner tank from the geyser unit,Supply of a new inner tank of the correct size, material, and specifications, and its installation into the geyser unit. Include all necessary gaskets and seals.Implementation of protective measures to prevent damage to surrounding walls, floors, and fixtures during the inner tankrepair complete as specified and directed.
Supply and application of Self Adhesive PVC Electrical Insulation Tape, capable of withstanding temperatures up to [100] °C, Dimensions 7.5 m x 18mmx 0.125mm, for insulating high-temperature electrical connections complete as specified and directed.
SANDHYA ENTERPRISES (BID ID -3393841)
SONU ENTERPRISES (BID ID -3395583)
M/S CHANDAN BUILDERS (BID ID -3405483)
ADITYA LAXMAN PASALKAR (BID ID -3398043)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .