| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.8 LAccepted-AOC | L1 | Accepted-AOC Techno commercially qualified | |
| 2 | L2₹3.9 L+₹14,472 (3.81%)Rejected-AOC | L2 | Rejected-AOC Techno commercially not qualified | |
| 3 | L3₹38,002−₹3.4 L (90.0%)Rejected-AOC AT MAIN ROAD PHUSRO DIST BOKARO PIN 829144 JHARKHAND | BOKARO | JHARKHAND | 829144 | L3 | Rejected-AOC Techno commercially not qualified |
Tender Value
Refer Docs
EMD Value
₹4,600
Closing Date
14 Feb 2025, 12:00 pmClosed
MADHU RANJAN KUMAR,PE(EnM),SDOCM
OFFICE OF THE PROJECT OFFICER,SDOCM,DHORI AREA,CCL
Errection of 02 nos tubular pole and overhead line and also shifting of 100KVA DG set from excavation workshop to SDOCM Substation
2025_CCL_327793_1
SDOCM/PE(EnM)/e.NIT/24-25/21DT 03.02.2025
Open Tender
Electrical and Maintenance Works
Item Wise
12 days
SDOCM
Please refer Tender documents.
2 documents required · 2 mandatory
₹4,600
7 Mar 2025
3 Feb 2025
15 Feb 2025
4 Feb 2025
14 Feb 2025
4 Feb 2025
4 Feb 2025 - 7 Feb 2025
Amount
Erection of steel/tubular or rail pole strut in cement concrete 1:3:6 (1 cement : 3 course sand : 6 graded stone aggregate. 40 mm nominal size) foundation incl. excavation and refilling and secured with holding clamps, bolts, nuts, etc. as required
S/E of stay set complete (Galvanized) with 19/20 mm dia x 1.8 m long stay rod, anchor plate of size 45cm x 45 cm x 7.5 mm thimble stay clamp, turn buckle (20mm x 60 cm) 7/4.00 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc as required.
Dismantling and shifting of 100 KVA DG set .
Supply and providing of 3Core x 95 Sqmm + 1C 70 Sqmm aerial bunch cable of 1.1 KV grade.
Laying of one number PVC insulated and PVC sheated/ XLPE power cable of 1.1 KV grade of following size direct in ground including excavation sand cushioning, protective covering and refilling the trench etc as required.
Supply and fixing of 400 Amp capacity TP&N disconnector fuse switch unit inside the exisiting panel board with ISI marked HRC fuses including drilling of holes in cubical panel, making connection, etc, as required.
Providing and laying in position cement concrete 1:2:4 (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as reqired (excluding reinforcement). 4.5 mtr x 2.5 mtr x 0.5 mtr = 5.625 cum.
Structrual steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Structural steel MS angle size 50 x 50 x 6 mm 6 Nos x 10' = 60', 5 nos x 16' = 80', 4 nos x 18' = 72, 6 nos x 8' = 48', 8 nos x 2' =16' Total- 276' = 84.12 mtr x 4.72 kg/mtr = 397.04 Kg, MS plate 25 x 5 (leg & breezing) 12 nos x 1' = 12' x 0.30 kg/ft = 3.60 Kg, Total 400.61 Kg
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washer or with G.I. washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 1.00 mm thick with zinc coating not mless than 275gm/ m2 Top roofing 6 mtr x 5 mtr = 30 Sqm
Total impact of GST for the purpose of CTC
M/S R.N. ELECTRICAL WORKS (BID ID -1126308)
M/s Sanjay Supplier (BID ID -1126536)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .