Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹51.6 LAccepted-AOC | L1 | Accepted-AOC l1 | |
| 2 | L2₹52.8 L+₹1.1 L (2.22%)Rejected-AOC 86 INDUSTRIAL AREA PHASE 1 PANCHKULA HARYANA 134109 | PANCHKULA | HARYANA | 134109 | L2 | Rejected-AOC l2 | |
| 3 | L3₹60.3 L+₹8.7 L (16.9%)Rejected-AOC 704 GYANKRIPA ESTATE BYPASS ROAD WARD NO 35 IMLIKHEDA CHHINDWARA 480001 | CHHINDWARA | CHHINDWARA | MADHYA PRADESH | 480001 | L3 | Rejected-AOC l3 | |
| 4 | L4₹66.1 L+₹14.5 L (28.1%)Rejected-AOC PLOT NO 82A SECTOR 5 IMT MANESAR GURGAON HARYANA 122051 | GURUGRAM | HARYANA | 122051 | L4 | Rejected-AOC l4 | |
| 5 | Rejected-Technical PLOT NO 272 PHASE IV SECTOR 57 HSIIDC KUNDLI SONIPAT SONIPAT HARYANA 131028 | SONIPAT | HARYANA | 131028 | - | Rejected-Technical not submitted notarized affidavit as per annexure-IX of SBD and NABL doesnot have mercury in stack emission |
Tender Value
₹74.9 L
EMD Value
₹1.5 L
Closing Date
6 Dec 2024, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE PNW
O/O CE GEN SARNI
Work contract for Monitoring of Ambient air quality, Stack emission, Water quality, Noise pollution, Fugitive emission, Work environment etc. at STPS, Sarni as per the guidelines of CPCB, MoEF CC, M.P. Pollution Control Board .
2024_MPPGC_375204_1
WT4710
Open Tender
Miscellaneous Works
Fixed-rate
730 days
Sarni
As per NIT PQR
14 documents required · 14 mandatory
₹2,000
Yes
₹1.5 L
Yes
28 Jul 2025
25 Oct 2024
9 Dec 2024
25 Oct 2024
6 Dec 2024
25 Oct 2024
AMBIENT AIR QUALITY MONITORING AT VARIOUS LOCATIONS FOR BELOW PARAMETERS -
PM10 μg/m3 , PM2.5 μg/m3, Ammonia (NH3) μg/m3, BENZENE μg/m3, Benzo (a) Pyrene (BaP) ng/m3, Lead (Pb) μg/m3, Arsenic (As) ng/m3, Nickel (Ni) ng/m3, Sulphur Dioxide (SO2), Nitrogen Dioxide (NO2) μg/m3, Ozone (O3) μg/m3, Carbon Monoxide (CO) mg/m3, Mercury (Hg) ng/m3.
STACK EMISSION MONITORING (UNITS #10 & #11) FOR BELOW PARAMETERS
Particulate Matter, SO2, NOx.
Mercury (Hg)
STP EFFLUENT TWO LOCATIONS: - 1- PLANT SITE, 2- COLONY SITE FOR BELOW PARAMETERS
pH, TSS, Oil & Grease
BOD (3 days 27oC), COD, Fecal Coliform (MPN/100ml), NH4-N, N-Total, PO4-P.
ASH WATER SAMPLES FROM ASH POND (TWO LOCATIONS 1- 111 HECT. AND 2- 130 HECT. ASH PONDS) FOR BELOW PARAMETERS
pH, TSS, TDS, Oil & Grease
BOD (3 days 27oC), COD, Chloride.
Fluoride, Cadmium, Lead, Arsenic, Mercury, Titanium, Zinc, Dissolved Oxygen, Nitrates, Sulphates, Chromium Hexavalent, Boron, Cyanide, Aluminium, Manganese, Phenolic Compound, Mineral Oils, Pesticides, Total Detergent
Monitoring of water quality in the following five: for below parameters (I) Denwa River (Sample point: 15 KM away from Power house) (II) Nallah in front of CE Office. (III) Tawa-Denwa rivers confluence point (Sample point: 25 KM away from Power house) (IV) Pata Nala (Sample point: 3 KM away from Power house) (V) Dhased Nala (Sample point: 15 KM away from Power house)
pH, TSS
Noise Pollution at various points in & around power house
Noise level (dB)
Water samples from Source of water (Satpura Reservoir) for below parameters
pH, TSS, TDS, Oil & Grease, BOD (3 days @ 27OC), COD, Chlorides, Flouride, Cadmium, Lead, Arsenic, Mercury, Titanium, Zinc, Dissolved Oxygen, Nitrates, Shulphates, Chromium Hexavalent, Boron, Cyanide, Aluminium, Manganese, Phenolic Compound, Mineral Oil, Pesticides, Total Detergent.
Boiler Blowdown for below parameters -
pH, Suspended Solids, Oil & Grease, Copper (Total), Iron Total.
Cooling Tower Blowdown for below parameters -
pH, Free Available Chlorine, Zinc, Chromium (Total), Phosphate.
Quality of Effluent Treatment Plant samples of - (i) RO Permeate water, (ii) RO Reject, (iii) Treated water of ETP - MPPGCL Hospital, (iv) Reject water of ETP - MPPGCL Hospital, for below parameters
pH, Suspended Solids, BOD (3 days 27oC), COD, Oil and Grease, TDS, CHLORIDES
Drinking Water Quality Analysis in Three Locations
All Parameters as per the CPCB guidelines & as per ISO 10500:2012 standard
Analysis of Raw Water for below parameters -
pH, Turbidity, Calcium (as Ca), Silica Reactive (as SiO2), Silica Non Reactive, M-Alkalinity (asCaCO3), Phenolphthalein Alkalinity (as CaCO3), Chloride (as Cl),Magnesium (as Mg), Total Dissolved Solids, Sulphate (as SO4), KMnO4 no. (Organic Matter), Iron (as Fe), Total Organic Carbon, Sodium (as Na), Potassium (as K), Total Anion, Total Cation.
Analysis of Oil Contaminated Waste Water in the Following Locations at - (I) Turbine Generator area of unit 10, (II) Turbine Generator area of unit 11, (III) Fuel Storage Area, for below parameters -
pH, TSS, TDS, BOD (3 days at 270C), COD, Oil & Grease, Chloride, Lead, Arsenic, Mercury, Nickel, Chromium, Cadmium, Zinc, Poly aromatic hydrocarbons (PAH), Poly Chlorinated biphenyls (PCBs).
Analysis of Sludge generated from- (I) DM Plant - IV, (II) ETP Clarifier, (III) Sewage Treatment Plant( plant Site), (IV) Sewage Treatment Plant (Colony Site) for below parameters
pH, TSS, TDS, Oil & Grease, BOD (3days@270C), COD, Chloride, Fluoride, Cadmium, Lead, Arsenic, Mercury, Titanium, Zinc, Dissolved Oxygen, Nitrates, Sulphate, Hexavalent chromium, Boron, Cyanide, Aluminum, Manganese, Phenolic Compound, Mineral Oil, Pesticides, Total Detergent.
Analysis of Water Samples from Toe Drain of Ash Pond (Two Locations 1- 111 HECT. and 2- 130 HECT. Ash Ponds) for below parameters
pH, TSS, TDS, Oil & Grease, BOD (3 days 27oC), COD, Chloride, Fluoride, Cadmium, Lead, Arsenic, Mercury, Titanium, Zinc, Dissolved Oxygen, Nitrates, Sulphates, Chromium Hexavalent, Boron, Cyanide, Aluminium, Manganese, Phenolic Compound, Mineral Oils, Pestisides, Total Detergent.
Monitoring of Ground Level concentration in the impact zone of Satpura Thermal Power Station (Minimum 10 sites monitoring in all directions) (Maximum GLC within 10km from the plant to be reported)
SO2, NOx, PM2.5, PM10, Hg.
Monitoring of Stack Emission of Dust Extraction System at following locations for below parameters - (I) Primary Crusher House - 1, (II) Secondary Crusher House - 2, (III) Bunker - 1, (IV) Bunker – 2
Particulate Matter
DG Set Stack Monitoring for below parameters
NOx, HC, CO, PM
Analysis of fugitive Emission at - (I) Mill Area Unit 10, (II) Mill Area Unit 11, (III) ESP Area Unit 10, (IV) ESP Area Unit 11, (V) Bunker 1, (VI) Bunker 2, (VII) Wagon Tippler, (VIII) Coal Storage Area, (IX) Primary Crusher, (X) Secondary Crusher, (XI) Silo Area
Fugitive Emission determination
Validation of Dust factor for Continuous Emission Monitoring System installed in chimney through iso-kinetic sampling.
Estimation of efficiency of Electrostatic Precipitator (ESP)
Work Environment Monitoring (Chlorination Plant)
Analysis of chlorine for short term exposure (15min.)
Analysis of chlorine for time weighted average concentration (8 hrs.)
Work Environment Monitoring (Chemical storage at DM Plant & Boiler Chemical dosing area unit 10 & unit 11)
Analysis of Ammonia for short term exposure (15min.)
Analysis of Ammonia for time weighted average concentration (8hrs.)
Analysis of Hydrazine time weighted average concentration (8 hrs.)
Work Environment Monitoring (DM Plant & ETP)
Analysis of Hydrogen chloride for time weighted average concentration (8 hrs.)
Analysis of Sodium hydroxide for time weighted average concentration (8 hrs.)
Work Environment Monitoring (Sulphuric Acid storage tank for CW Treatment)
Analysis of Sulphuric acid for time weighted average concentration (8 hrs.)
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .