| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.1 LAccepted-AOC | L1 | Accepted-AOC Being L1 bid | |
| 2 | L2₹26.6 L+₹1.9 L (7.67%)Rejected-AOC | L2 | Rejected-AOC Being higher than L1 bid | |
| 3 | L3₹26.8 L+₹2.1 L (8.41%)Rejected-AOC | L3 | Rejected-AOC Being higher than L1 bid | |
| 4 | L4₹26.8 L+₹2.1 L (8.57%)Rejected-AOC | L4 | Rejected-AOC Being higher than L1 bid | |
| 5 | L5₹26.9 L+₹2.2 L (8.91%)Rejected-AOC | L5 | Rejected-AOC Being higher than L1 bid |
Tender Value
₹24.2 L
EMD Value
₹48,400
Closing Date
29 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE SILCHAR
GE SILCHAR, PO-ARUNACHAL, DIST-CACHAR, ASSAM-788025
SPECIAL REPAIR TO BLDG NO T 275 AND T 276 AT CIJW SCHOOL VAIRENGTE UNDER GE SILCHAR
2021_MES_476062_2
8659/E8
Open Tender
Civil Works
Item Rate
180 days
VAIRENGW
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE SILCHAR
₹48,400
Yes
31 Dec 2021
12 Nov 2021
30 Nov 2021
12 Nov 2021
29 Nov 2021
23 Nov 2021
60 days
Amount
PART-I (B/R WORKS) Excavating in post holes (or similar holes) each n exc 0.5 cum each, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in soft/loose soil complete all as specified & directed
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles from site and rubbish off the premises complete all as specified & directed.
Demolition of brick/stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work and pre-cast concrete articles complete all as specified & directed.
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness as in roof coverings, chajja, wall clading and the like complete all as specified and directed.
Demolition of plain cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
Taking down cement plaster on brick or stone walls etc. including raking out joints hacking for key scrubbing down with water complete all as specified & directed
Demolition of reed lathing, single or double including battens and plaster or chicken wire lathing complete all as specified & directed.
Taking down chowkhats or frames not exceeding 1.5 sqm each with shutters (without taking off shutters from frame) complete all as specified and directed.
Taking down chowkhats or frames exceeding 1.5 sqm but not exceeding 4 sqm each with shutters (without taking off shutters from the frame) complete all as specified and directed.
Dismantling timber boarding of any description fixed in any position with nails complete all as specified and directed.
Dismantling of timber fillets rails, posts, rafters, purlins etc under 40 Sqcm in section, in any position in unframed work complete all as specified and directed.
Dismantling timber scantlings 40 sqcm and over in section, in any position, unframed work, etc complete all as specified.
Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/ blankets, any thickness, including cover fillets, etc complete all as specified & directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Material and labour for PCC 1:4:8 type D2 using 40 mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed.
M&L for Brickwork with subclass ‘B’ bricks straight or curved on plan exc 6 m mean radius built in CM 1:6 complete all as specified & directed.
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified & directed.
All as per Srl item No 17 above but except bricks complete all as specified & directed.
M&L Plain cement concrete 1:3:6 type C-1, (using 20 mm graded stone aggregate) as in bed blocks, holdfast blocks, coping, lintels upto 1.5m clear span, cills, lin steps, kneelers, bed plates, apex stones kerbs benching and similar work including necessary form work complete all as specified and directed.
Material and labour for formwork to sides of foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar work vertical or to batter for rough finished flat surface of concrete complete all as specified and directed.
Material and labour for formwork to sides of Columns, pillars, piers, posts and struts for rough finished flat surfaces of concrete complete all as specified and directed.
Material and labour for Formwork to edges of concrete flats, treads, breaks in floors,window cills, concrete rail ings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm for rough finished surfaces complete all as specified and directed.
Material and labour for mild steel TMT bars 10mm dia and over cut to length bend to shape required including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or secruing with clips complete all as specified and directed.
All as per item No. 23 above but 6mm to 8 mm dia complete all as specified and directed
All as per item No. 23 above but 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders etc complete all as specified and directed
M&L for Reinforced cement concrete Design mix (M-25) using 20 mm graded aggregate in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc., basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L RCC Design mix (M-25) using 20 mm graded aggregate in Columns, pillars, piers, posts and struts complete all as specified and directed.
M&L RCC Design mix (M-25) using 20 mm graded aggregate in beams, cantilevers, bressummers, lintels over 1.50 mtr span complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregates as in cills,band & the like complete all as specified and directed.
M&L for 40 mm thick Damp proof course in PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregates to horizontal or vertical surfaces including necessary formwork, mixed with WPC as per manufacturers instructions, complete all as specified and directed. Note: WPC shall be measured & paid seperately)
Material and labour for rendering 15 mm thick in cement mortar(1:6) on brick wall or concrete surfaces finished the surfaces even and fair complete all as specified and directed.
M&L for Rendering 15mm thick in two layers [base layer 10mm in CM 1:4 & finishing layer 5mm thick in cement mortar (1:4)] using water proofing compound in 2nd layer only on brick work or concrete surfaces of wall, surfaces finished even and smooth using extra cement complete all as specified & directed. Note : WPC shall be measured and paid separately.
Supply only of Integral waterproofing compound complete all as specified & directed.
Material and labour for providing 75 mm thick plain cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregate as in sub base of floor complete all as specified and directed.
Material and labour for providing 100 mm thick plain cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregate as in sub base of floor complete all as specified and directed.
S&F Non Skid ceramic tiles colour 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 but not exceeding 0.18 sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over & including 15 mm thick screed bed or bedding layers in cement mortar 1:6 including brushing with neat cement slurry with 3 Kg of cement per sqm complete all as specified and directed.
Material and labour for reflective rubber moulded chequered cement concrete tiles 30cm x 30 cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with white cement or colour pigment to match the colour of tiles over & including 15 mm thick screed bed or bedding layers in cement mortar 1:6 complete all as specified and directed. complete all as specified.
M&L for coloured glazed ceramic tiles (300x200) 7mm thick on vertical surface such as skirting, dados, risers etc. set and jointed in neat cement slurry and pointed in coloured cement or pigment to match colour of tiles over & incl 10 mm thck screed layer in CM 1:4 complete all as specified and directed.
Supply and fix Steel work in trusses, purlins, posts and the like using tubular/ square hollow sections including special shaped washer etc. complete using ERW or induction butt welded tubes/SHS conforming to IS.1161 - 2014 / IS.4923 - 1997 grade St.-210 complete all as specified and directed.
S&F Mild steel screw bolt 11 to 15 mm dia (machine made) with hexagonal or square heads at one end and screwed at the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 22.50cm and n. exc 30 cm long, complete all as specified and directed.
S&F plates (plain or chequered) Fe-290 (Gde E165) cut to required size, forming holes to receive holding down bolts and welded to tubular/square hallow section trues at both ends complete all as specified and directed.
S&F for Pre-painted galvaume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed.
Supply and fixing pre-painted 4mm thick HPSC ( high pressure steam cured) non asbestos fibre cement board with design surface as in false ceiling with powder coated GI/aluminium snap grid/section of size 600mm x 600mm fixed to wall hanging from soffits/trusses using adjustable supporting hanger comprising of 2mm dia wire 'J' type hook, nuts,bolts, holding down clips with GI/aluminium section of size 36.5mm x 25mm x1.4mm (Main Tee) and 23.5mm x 26.4mm x 1.4mm (Cross Tee) and wall angle of size 25mm x 25mm x 1.4mm, complete all as specified and directed
Supply and fix Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm Plain colour PVC Sheet on back face complete all as specified.
Supply and fix 30 mm thick factroy made solid panel PVC door shutter (style) consisting of frame made out of MS tube for top and bottom rails MS frame shall be covered with neat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside the solvent cement for style and single side pre laminated PVC sheet for top rails, lock rails and bottom rails on either side and as gap insert for top rails and bottom rail , the panel will be of wire gauzed i.e. panel will be of wire gauze in lieu of wood grain printed PVC sheet panel. The wire gauze shall be wrapped on an additional square 8mm M.S. Solid tube and this tube shall be welded to M.S. tubes. The wire gauge shall be stretched to tighten firmly complete all as specified and directed.
Supply and fix Framed work such as in Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed.
Supply and fix Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work , conforming to Fe.290.Gde-E-165 complete all as specified and directed.
Supply and fix Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing conforming to Fe.410 W.( Gde-E-250) complete all as specified and directed.
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed complete all as specified and directed.
Supply and fix 100 mm size stainless steel butt hinges medium weight fixed with stainless steel screws all as specified.
Supply and fix Aluminium sliding door bolt, 300 mmwith hasp, staple(bolt type) & fixing clips at sheet, cast or extruded sections and fixing bolts and sliding bolt of extruded section or cast aluminium alloy and fixed,complete all as specified and directed.
S&F 200 mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed.
S&F 150mm extruded aluminium alloy handles cast type anodized complete all as specified and directed.
Supply and fix 3 ways sliding anodized aluminium glazed window shutter with frame with the following specification all as specified & directed. (a) Window frame 3 track of size 95mmx25mmx1.5mm thick (b) Stiles and rails of size 35mmx25mmx1.5mm (c) 35mmx35x1.5mm T section mullion (d) PVC gasket with 10mm thick tinted glass, incl. aluminium handles with necessary locking arrangement for 02 Nos glazed shutter (e) Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire stapples incl. aluminium handles with necessary locking arrangement for 01 No gauzed shutter Note : Measurement to be taken as overall width and height of window. No shutter or frame to be measured separately. All necessary accessories including tinted glass and stainless steel wire cloth required for assembling and fixing window at proper place complete are deemed to be inclusive.
Supply and fix 2 way sliding anodized aluminium glazed ventilator shutter with frame consists of following specification complete all as specified and directed. (a) Ventilator frame 2 track of size 60mmx25mmx1.5mm thick (b) Stiles and rails of size 35mmx25mmx1.5mm (c) 35mmx35x1.5mm T section mullion (d) PVC gasket with 4mm thick tinted glass, incl. aluminium handles with necessary locking arrangement Note : Measurement to be taken as overall width and height of ventilator. No shutter or frame to be measured separately. All necessary accessories including tinted glass required for assembling and fixing window at proper place complete are deemed to be inclusive.
Material and Labour for applying 1mm thick wall care putty on wall complete all as specified and directed.
M&L for preparation of new or previously untreated steel surface of any description not otherwise described over 10 cm in width or girth & applying two coats synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
Material and Labour for applying two coats of acrylic distemper over a coat of primer as per manufacturers instructions including preparation of newly plastered surfaces, complete all as specified and directed.
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces, complete all as specified and directed.
PART-II (E/M WORKS) Taking down carefully copper/aluminum existing point wiring (light/fan/socket or power points) complete incl wooden battens/casing capping or conduit etc (without disturbing existing fittings point wiring etc) and all connected fittings such as switch, socket, ceiling rose, lamp holder, brackets ceiling fittings, bulk head fittings and fan regulator etc and making good to disturbed surfaces of wall floor etc complete all as specified and directed.
Dismantling of old unserviceable main switches DBs, MCB enclosures, electric meter, PVC rectangular blocks etc and keeping in safe custody either for reuse or for disposal Including making good to the disturbed surface of wall complete all as specified and directed.
M&L for Point wiring using 1100 volt grade FRLSH PVC insulated unsheathed multi strand copper conductor cable 1.5 sqmm including 1.5 Sqmm FRLSH PVC insulated unsheathed multi strand 1100 volt grade copper conductor earth wire drawn through and including concealed PVC conduit of appropriate size not less than 20 mm dia and 1.8 mm thick including all fittings viz tees, bends, junctions box , connecting earth including cutting groove for concealed wiring, making good to disturbed surface of wall/floor with cement mortar and finishes to match existing including connection of cable with MCBs or bus bar shall be done through proper size copper/brass thimble of pin/u type etc for one light/fan/bell point complete all as specified and directed.
All as per item No.63 above but for 5 Amps socket Point (Same board), complete all as specified and directed
All as per item No.63 above but for 5 Amps socket Point (Independent board), complete all as specified and directed
All as per item No. 63 above but for but for 15 Amps socket outlet on independent board with 1100V grade PVC insulated and unsheathed 2.5 Sqmm multi strand FRLS copper conductor cable and PVC insulated and unsheathed copper conductor 2.5 Sqmm , 1100 volt grade as earth continuity conductor drawn through and including concealed PVC conduit of appropriate size not less than 20 mm dia and 1.8 mm thick including all fittings viz tees, bends, junctions box , connecting earth including cutting groove for concealed wiring, making good to disturbed surface of wall/floor with cement mortar and finishes to match existing including connection of cable with MCBs or bus bar shall be done through proper size copper/brass thimble of pin/u type etc for one light/fan/bell point complete all as specified and directed.
S & F switch piano, 5Amp single pole, flush type one way 230 volts complete all as specified and directed.
S & F Socket outlet 2 in 1, 5 pin, 5 Amps flush type complete all as specified and directed.
S & F Switch Socket combination outlet 2-in-1, 2 pin & 3 pin 5 Amps flush type complete all as specified and directed
S & F Switch Socket combination outlet 2-in-1, 3pin 5 Amps & 3 pin 15 Amp ISI marked flush type complete all as specified and directed .
S & FCeiling rose, 3 phase/PVC/ polycarbonate, isolated body complete all as specified and directed
S & F stepped type electronic fan regulator flush type (ISI Mark) socket type complete all as specified.
Supply and Fix Angular Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings with and incl LED lamp/bulb ball type of 10Watt complete all as specified.
S & F exhaust fan having PVC body of size 250 mm sweep AC single phase, 240 Volt of size with louvers connecting up including provision of fixing clamp, nut bolt and cable from ceiling rose or connector to fan, including taking down old UNSV plastic body fan complete all as specified and directed. Make : BAJAJ, Maxima DxI 250 mm White Dom Ex Fan
S&F LED aesthically disigned linear mirror light provided with a high output PMMA diffuser for glare free light complete all as specified and directed. Make:- Crompton Cat part No LCL-07-CDL or equivalent to Bajaj/Philips/Wipro/Syska LED/ M/S Surya Roshni Limited/M/S Jaquar & Company Pvt Ltd/Havells
S&F LED linear light fittings 20 Watt basic all purpose surface and wall mounted and LED batten with polycarbonate housing and intrigated electronic driver and connecting with 3 core flexible copper cable PVC insulated of size 16/0.20 mm etc complete all as specified and directed. Make:- Havells Cat No. LHEWEBP7IN1W020 or equivalent to Bajaj/Philips/Wipro/Syska LED/ M/S Surya Roshni Limited/M/S Jaquar & Company Pvt Ltd/Crompton Greaves
S&F LED Bldg Security light fitting of 25 watt fixed on & incl MS bracket, made out of 40 mm bore medium grade GI pipe 1.5 mtr long with MS clamps and nut bolts of suitable size complete all as specified and directed. Make:- Havells Cat No. ENDURAPEARLSL25WLED 757SASYTOPC or equivalent to Bajaj/Philips/Wipro/Syska LED/ M/S Surya Roshni Limited/ M/S Jaquar & Company Pvt Ltd/Crompton Greaves
S & F LED light fitting 1x9W/1X10W bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable siz complete all as specfied and directed. Make : Havells Cat Part No. HEXAFIT10WLED857SSYMBOPC or equivalent to Bajaj/Philips/Wipro/Syska LED/ M/S Surya Roshni Limited/M/S Jaquar & Company Pvt Ltd/Crompton Greaves
M&L for fan hook fabricated with MS flat 25x6mm 300 mm long 02 nos bend to shape drilled with holes and MS nuts ,bolts and washers of required side with one coat of primer and two coats of paints complete all as specified and directed
Supply and fix sheet metal enclosure for DB's TPN with 200 Amps rated bus bar 240Volts, 04 way double door etc complete all as specified and directed.
Supply and fix sheet metal enclosure for DB's SPN with 200 Amps rated bus bar 240Volts, 08 way double door etc complete all as specified and directed.
Supply and fix MCB TPN 63 Amps 240 Volts 'C' series complete all as specified and directed.
Supply and fix MCB SPN 40 Amps 240 Volts 'C' series complete all as specified and directed.
Supply and fix MCB SP 5 to 40 Amps 240 Volts 'C' series complete all as specified and directed.
Material and labour for Sub main wiring with approved colour coding as per IS with two single core PVC insulated cable multi strand 1100 volt grade copper conductor of size 6 Sq. mm nominal area including one run of PVC insulated with 6.0 Sqmm (nominal area) multi strand 1100 volt grade copper conductor as earth wire complete all as specified and as directed. with drawn through and including concealed PVC conduit of appropriate size not less than 20 mm dia and 1.8 mm thick including all fittings viz tees, bends, junctions box , connecting earth including cutting groove for concealed wiring, making good to disturbed surface of wall/floor with cement mortar and finishes to match existing complete all as specified and directed. Note:- Two runs of 6 sqmm cable, one run of 6 sqmm cable and one run of PVC casing caping will be measured as one unit.
Taking down exhaust fan / wall mounted fan / Ceiling fan of any size/sweep for replacing bearing, bush disconnecting the wire from existing ceiling rose and refixing the same cleaning dust, oiling greasing, servicing and replacing bearing, gun metal bush, rubber reel with clamp and nut-bolt, washer, lock pin, excellation gear sytem, boby painting etc as existing including connecting flexible 3 core cable from ceiling rose to connector of fan complete all as specified and directed.
Taking downCeiling fan of any size/sweep for replacing bearing, bush including rewinding after disconnecting the wire from existing ceiling rose and refixing the same after rewinding, minimum rewinding size 300 grade cleaning dust, oiling greasing, servicing and replacing bearing, gun metal bush, rubber reel with clamp and nut-bolt, washer, lock pin, excellation gear sytem, boby painting etc as existing including connecting flexible 3 core cable from ceiling rose to connector of fan complete all as specified and directed.
Excavating in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sqm on plan and not exceeding 1.5 mtr in depth and getting out soft/loose soil complete all as specified.
Returning, filling in, trenches including Spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick all as specified.
Removing excavated surplus soil to a distance n.exc. 50m and depositing where directed at level n.exc. 1.50m above the starting point complete all as specified and directed.
Material and labour for laying of bricks locally available sub-class 'B' brick (old size) for cable protection cover laid flat and dry in trenches over the cable perpendicular to the directon of cable complete all as specified and directed.
Supply and spread dry fine sand in trenches as sand cushioning to under ground cable for protection with fine river sand and provide reqd cover after punning down complete all as specified and directed. Note:- Thickness of sand cushion after punning down will be measured and paid separately.
Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 25 Sqmm 3.5 core laid in trenches/fixed to wall/under road/pipe etc with and including copper cable glands & copper thimbles incl taking out old unserviceable cable complete all as specified and directed.
Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 16 Sqmm 4 core laid in trenches/fixed to wall/under road/pipe etc with and including copper cable glands & copper thimbles incl taking out old unserviceable cable complete all as specified and directed.
Material & labour GI tube light grade 40 mm bore for protection of UG cable including dismantling of old unsv pipe complete all as specified and directed.
Supply, Instalation, testing and commissioning of CPRI approved outdoor type LT feeder pillar box (i.e. Bus Bar Box) of 0.45x0.45x0.30 Mtr minimum size manufactured by CPRI approved firm cubical floor mounted type factory made totally enclosed, dust ad vermin proof made out of 3.15 mm thick MS sheet duly painted with powder coated both side in and out, having proper locking arrangement in both front and rear side aluminium bus bar not less than 200 amps rating duly drilled holes for connections and mounted on epoxy based post insulators for 3 phase, 4 wire, 415 volts, 50 HZ AC supply, hibling , cable entry boxes, cable gland incl iron angle frame (bottom portion of the panel), grouted by using foundation 1:2:4 type B2 with 40 mm graded stone aggregates totally tested as per IEC 61439-I all as specified and directed. Note: Excavation / earthwork for grounting and PCC foundation for LT Panel shall deemed to be included in quoted rate.
Earthing complete with galvanized steel earth plate electrode 60cmx 60cm x 6 mm buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized earth lead wire 4 mm dia by means of galvanized iron or steel bolts, nuts, check nuts and washers, and connected to equipments as directed, including funnel with GI med grade watering pipe 20 mm bore, wire mesh, charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with concrete pit in PCC 1:3:6 type C1, 50 mm thick pre cast RCC 1:2:4 type B1 cover slab reinforced with 8 mm dia deformed bar 15 cm C/C and suitable handle of 10 mm dia round bar, 15mm bore medium grade protection pipe upto 7.5 m for earth lead protection including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance not exceeding 50 m and necessary testing complete all as shown on electrical plate No. 3 of MES Schedule 2009, Part-I complete all as specified and directed.
m/s builders and suppliers
MS AFTAB LASKAR
M/S RAJU ENTERPRISES AND BROS
M/S MOLOY KUMAR DEY
M/S LUIT CONSTRUCTION
SURANA CORPORATION
M/S SANJIB DEB
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .