| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹65.6 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST BIDDER | |
| 2 | L2₹73.9 L+₹7.2 L (10.7%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹75.7 L+₹9.0 L (13.5%)Rejected-Finance DIWANBADA MANEGAON POST OFFICE KHAMARIA JABALPUR 482005 M P | JABALPUR | MADHYA PRADESH | 482005 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹78.5 L+₹11.8 L (17.7%)Rejected-Finance B 87 SHAM NAGAR KHAYALA ROAD NEW DELHI 110018 | NEW DELHI | NEW DELHI | DELHI | 110018 | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹87.5 L+₹20.8 L (31.1%)Rejected-Finance HOUSE NO C 214 SECTOR C INDRA VIHAR COLONY TILAK NAGAR HOUSING SOCIETY AIRPORT ROAD LANDMARK NEAR BHOPAL GIRLS SCHOOL PANCHVATI BHOPAL MP 462030 | BHOPAL | BHOPAL | MADHYA PRADESH | 462030 | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹1.1 Cr
EMD Value
₹1.9 L
Closing Date
28 Sept 2024, 6:00 pmClosed
CWE Jabalpur
HQ Commander Works Engineer, Supply Marg, P B No. 54, Jabalpur
REPAIR AND REPLACEMENT OF SUBMAIN/INTERNAL WIRING MCB DB FITTING AND FIXTURE WITH ALLIED WORKS OF GRC UNDER GE (W) JABALPUR
2024_MES_672401_1
81069/E8
Open Tender
Electrical and Maintenance Works
Works
180 days
Jabalpur
AS PER NIT
7 documents required · 7 mandatory
₹1,000
GE West Jabalpur
₹1.9 L
Yes
25 Nov 2024
6 Sept 2024
30 Sept 2024
6 Sept 2024
28 Sept 2024
14 Sept 2024
7 Sept 2024 - 13 Sept 2024
Amount
Taking down carefully any type of old unserviceable point wiring copper or aluminium conductor (light, fan, socket, bell or power) point complete with fittings such as switches, ceiling roses, lamp holders, sockets, fan regulators, call bell, light fittings with PVC conduit surface / concealed or wooden battens including sunken cast iron / pressed steel terminal boxes etc complete all as specified & directed .
Taking down carefully any type of old unserviceable submain wiring with PVC conduit surface / concealed or wooden battens etc complete all as specified & directed .
M&L for preparing old plastered or unplastered surfaces of walls and applying two coats of cement based paint complete all as specified and directed.
M&L for provision of sub main wiring with two runs of single core FRLSH PVC insulated, unsheathed, mutistranded copper conductor cable of size 4.0 sqmm drawn in and including rigid PVC conduit medium grade ISI marked not less than 20mm dia with its accessories, concealed type, including one run of single core FRLSH PVC insulated, unsheathed, multistranded copper conductor cable of size 4 sqmm as earth continuity and cutting chases as per standard engineering practice & making good the disturbed surfaces as per existing finish complete all as specified & directed. Notes:- (i) Finished sub main wiring with two runs of 4.0 sqmm cable & one run of 4 sqmm cable alongwith PVC conduit and its accessories shall be measured and paid as one unit length. (ii) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. (iii) Colour coding for wiring/ bus bar/ main connection shall be followed .
M&L for provision of sub main wiring with two runs of single core FRLSH PVC insulated, unsheathed, mutistranded copper conductor cable of size 6.0 sqmm drawn in and including rigid PVC conduit medium grade ISI marked not less than 25mm dia with its accessories, concealed type, including one run of single core FRLSH PVC insulated, unsheathed, multistranded copper conductor cable of size 6 sqmm as earth continuity and cutting chases as per standard engineering practice & making good the disturbed surfaces as per existing finish complete all as specified & directed. Notes:- (i) Finished sub main wiring with two runs of 6.0 sqmm cable & one run of 6 sqmm cable alongwith PVC conduit and its accessories shall be measured and paid as one unit length. (ii) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. (iii) Colour coding for wiring/ bus bar/ main connection shall be followed .
M&L for provision of sub main wiring with two runs of single core FRLSH PVC insulated, unsheathed, mutistranded copper conductor cable of size 10.0 sqmm drawn in and including rigid PVC conduit medium grade ISI marked not less than 25mm dia with its accessories, concealed type, including one run of single core FRLSH PVC insulated, unsheathed, multistranded copper conductor cable of size 10 sqmm as earth continuity and cutting chases as per standard engineering practice & making good the disturbed surfaces as per existing finish complete all as specified & directed. Notes:- (i) Finished sub main wiring with two runs of 10.0 sqmm cable & one run of 10 sqmm cable alongwith PVC conduit and its accessories shall be measured and paid as one unit length. (ii) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. (iii) Colour coding for wiring/ bus bar/ main connection shall be followed .
Material & Labour for point wiring with three layer PVC Insulated 1.5 Sqmm multi-strand copper conductor FRLSH cable 1100 Volts grade drawn into and including concealed PVC conduits medium grade not less than 20mm( ISI marked) including all fitting and fixing accessories including 1.25 mm thick sunken pressed steel terminal boxes/Modular metal flush box duly painted with two coats of anti-corrosive paint outside and two coats of aluminium paint inside with and including 3mm thick hylam brand laminated white bakelite sheet cover for mounting switches, sockets, fan regulators fixed with CP screws with cup wahsers and PVC insulated 1.5 Sqmm multi-stranded copper conductor cable as earth wire and making good the disturbed surfaces with cement sand mortar 1:3 to match with the existing surfaces complete all as specified & directed by Engineer-in-charge for One light Point controlled by one switch 5/6 Amp.
Ditto as per Item Ser No 7 above but for one Fan Point controlled by one switch 5/6 Amp.
Ditto as per Item Ser No 7 above but for one Bell Point controlled by one switch 5/6 Amp.
Ditto as per Item Ser No 7 above but for one socket point 5 Amp controlled by one switch on same board.
Ditto as per Item Ser No 7 above but for one socket point 5 Amp controlled by one switch on Independent board.
Ditto as per Item Ser No 7 above but for one light point controlled by two way switch.
M&L for Point wiring with three layer PVC insulated 2.5 sqmm multi stranded copper conductor FRLSH cable 1100 volts grade for 3/6 pin switch socket outlet 15 Amp on independent board, drawn into and including the concealed conduits including all fitting and fixing accessories including sunken pressed steel terminal boxes suitable of modular switches /sockets and including inner/ outer plates cover for mounting /modular switches sockets ,modular fan regulators fixed with CP screws with cup washers and PVC insulated 2.5 sqmm multi stranded copper conductor cable as earth wire and making good the disturbed surfaces with cement sand mortar all as specified and directed by Engineer in charge .
Material & Labour for point wiring with three layer PVC Insulated 1.5 Sqmm multi-stranded copper conductor FRLSH cable 1100 Volts grade drawn into the existing conduits including all fitting and fixing accessories including 1.25 mm thick sunken pressed steel terminal boxes duly painted with two coats of anti-corrosive paint outside and two coats of aluminium paint inside with and including 3mm thick hylam brand laminated white bakelite sheet cover for mounting switches, sockets, fan regulators fixed with CP screws with cup wahsers and PVC insulated 1.5 Sqmm multi-stranded copper conductor cable as earth wire and making good the disturbed surfaces with cement sand mortar (1:3) to match with the existing surfaces complete all as specified & directed by Engineer-in-charge for one light Point controlled by one switch.
Ditto as per Item Ser No 14 above but for one Fan Point controlled by one switch 5/6 Amp.
Ditto as per Item Ser No 14 above but for one Bell Point controlled by one switch 5/6 Amp.
Ditto as per Item Ser No 14 above but for one socket point 5 Amp controlled by one switch on same board.
Ditto as per Item Ser No 14 above but for one socket point 5 Amp controlled by one switch on Independent board.
Ditto as per Item Ser No 14 above but for one light point controlled by two way switch.
M&L for Point wiring with three layer PVC insulated 2.5 sqmm multi stranded copper conductor FRLSH cable 1100 volts grade for 3/6 pin switch socket outlet 15 Amp on independent board, drawn into the existing conduits including all fitting and fixing accessories including sunken pressed steel terminal boxes suitable of modular switches /sockets and including inner/ outer plates cover for mounting /modular switches sockets ,modular fan regulators fixed with CP screws with cup washers and PVC insulated 2.5 sqmm multi stranded copper conductor cable as earth wire and making good the disturbed surfaces with cement sand mortar (1:3) to match with the existing surfaces complete all as specified and directed by Engineer in charge .
M&L for point wiring in PVC casing and caping complete with FRLSH PVC insulated, unsheathed stranded copper conductor of nominal area 1.5 Sqmm, 1100 volts grade, along with one single run of same size and type of copper wire as continuous earth wire to common earth dolly in and sunken terminal boxes pressed MS/GI steel terminal boxes not less than 1.20 mm thick for mounting switch, socket etc including 3 mm thick Hylam brand sunmica laminated sheet cover or inner outer plates for modular switches with brass screw and cup washers with all accessories and making good the disturbed surface with cement mortar in (1:3) to match with existing surface complete all as specified and directed
Ditto as per Item Ser No 21 above but for one socket point 5 Amp controlled by one switch on same board.
Ditto as per Item Ser No 21 above but for one socket point 5 Amp controlled by one switch on Independent board.
Ditto as per Item Ser No 21 above but for one light point controlled by two way switch.
M&L for Point wiring with three layer PVC insulated 2.5 sqmm multi stranded copper conductor FRLSH cable 1100 volts grade for 3/6 pin switch socket outlet 15 Amp on independent board, drawn in with and including casing and caping point wiring using 2.5 Sqmm (Nominal area)triple layer FRLSH PVC insulated unsheathed copper conductor 1100 volts for one 3/6 pin socket outlet ,suitable for 6/16 amps on “independent board” with 2.5 sqmm one single run copper wire as continuous earth wire to common earth dolly and making good the disturbed surfaces to match with the existing finish complete all as specified and directed .
S&F call bell ding dong sound type suitable for AC 230 volt single pole complete all as specified & directed.
S&F switch bell push flush type suitable for 5 Amp 230 Volt of polycarbonate body complete all as specified & directed.
S&F switch piano flush type suitable for 5 Amp 230 Volt of polycarbonate body complete all as specified & directed.
S&F socket outlet 2 in 1, 5 Pin 5 Amp flush type of polycarbonate body complete all as specified & directed.
S&F Switch socket combination 5 in 1, 5 pin 5/6 Amps flush type universal of polycabonate body complete all as specified & directed.
S&F Switch socket combination 5 in 1, 5 pin 6/16 Amps flush type universal of polycabonate body complete all as specified & directed.
S&F lamp holder / batten or angle holder Insulated body incl 9 watt LED bulb with back plate suitable for batten fittings complete all as specified & directed
S&F Ceiling rose surface type 60x30 mm three terminals of polycarbonate body complete all as specified & directed.
S&F Ceiling Fan regulator electronic type 120 Watt capacity of polycarbonate body ISI marked complete all as specified & directed.
S&F, in replacement, frame plate for modular switch 1 module including screws and washers etc model/make as per existing at site complete all as specified and as directed.
S&F, in replacement, frame plate for modular switch 2 module including screws and washers etc model/make as per existing at site complete all as specified and as directed.
S&F, in replacement, frame plate for modular switch 3 module including screws and washers etc model/make as per existing at site complete all as specified and as directed.
S&F, in replacement, frame plate for modular switch 4 module including screws and washers etc model/make as per existing at site complete all as specified and as directed.
S&F, in replacement, frame plate for modular switch 6 module including screws and washers etc model/make as per existing at site complete all as specified and as directed.
S&F, in replacement, frame plate for modular switch 8 module including screws and washers etc model/make as per existing at site complete all as specified and as directed.
S&F, in replacement, MS Housing box 1/2 module suitable for modular switch as per existing switch box and making good the disturbed surface complete all as specified and as directed.
S&F, in replacement, MS Housing box 3 module suitable for modular switch as per existing switch box and making good the disturbed surface complete all as specified and as directed.
S&F, in replacement, MS Housing box 4/5 module suitable for modular switch as per existing switch box and making good the disturbed surface complete all as specified and as directed.
S&F, in replacement, MS Housing box 6/8 module suitable for modular switch as per existing switch box and making good the disturbed surface complete all as specified and as directed.
S&F, in replacement, modular switch 6-10 Amps one module 230 volts AC as per existing model/make complete all as specified and as directed
S&F, in replacement, modular switch 16 Amps one module 230 volts AC as per existing model/make complete all as specified and as directed
S&F, in replacement, modular socket, 6A -2/3 pin combined 2 module, 230 volts AC as per existing model/make complete all as specified and as directed.
S&F, in replacement, modular socket, 6/16A -2/3 pin combined 2 module, 230 volts AC as per existing model/make complete all as specified and as directed .
S&F, in replacement, modular fan regulator, 2 Module 4 step 180w heavy duty 230 volts as per existing model/make complete all as specified and as directed.
S&F, in replacement, 3mm thick hylam sheet of any size including brass screws and washers etc as per requirement at site complete all as specified and as directed.
S&F, in replacement, modular bell push switch piano, flush type, 6 Amps complete all as specified and as directed.
Supply & Fixing, in repair, single pole and netural sheet metal enclosure with a two pin and earth plug and socket complete with 01 number single pole MCB 20 Amps complete all as specified & directed.
Supply & Fixing, in repair, sheet metal enclosure MCB DB double door [Acrylic], single pole and neutral, 240 volts, 8 way with 200 Amp, 10 KA breaking capacity rated bus bar with blanking plate wherever required and IP-43 degree protection complete all as specified & directed.
Supply & Fixing, in repair, sheet metal enclosure MCB DB double door [Acrylic], single pole and neutral, 240 volts, 4 way with 200 Amp, 10 KA breaking capacity rated bus bar with blanking plate wherever required and IP-43 degree protection complete all as specified & directed.
Supply & Fixing, in repair, sheet metal enclosure MCB DB double door [Acrylic], single pole and neutral, 240 volts, 12 way with 200 Amp, 10 KA breaking capacity rated bus bar with blanking plate wherever required and IP-43 degree protection complete all as specified & directed.
S&F in replacement sheet metal enclosure MCB DB double door [Acrylic], Triple pole and neutral, 440 volts, 4 way with 200 Amp, 10 KA breaking capacity rated copper bus bar with blanking plate wherever required and IP-43 degree protection complete all as specified & directed.
S&F in replacement MCB Triple Pole and Neutral 63 Amps,415 V ,10KA breaking capacity complete all as specified & directed.
S&F in replacement MCB Single Pole and Neutral 240Volt, 40 Amps,10KA breaking capacity complete all as specified & directed.
S&F in replacement MCB Single Pole and Neutral 240Volt, 63 Amps,10KA breaking capacity complete all as specified & directed.
S&F in replacement MCB Single Pole 240Volt, upto 40Amps,10KA breaking capacity complete all as specified & directed.
Supply & Fixing in repair single pole and netural sheet metal enclosure with a two pin and earth plug and socket complete with 01 number single pole MCB 20 Amps complete all as specified & directed.
S&F in replacement switch piano type switch two way AC 230 volts 6 Amps as per on existing switch board complete all as specified & directed..
Supply & Fixing in repairs RCBO four Pole 240Volt, 63 Amp,100 MA protection for earth over load and short circuit complete all as specified & directed.
Supply & Fixing in repairs RCBO double Pole 240Volt, 32 Amp,100 MA protection for earth over load and short circuit complete all as specified & directed.
Supply & Fixing Smart bright Batten Series, LED luminaire using LED 18 watt with diffuser which ensures uniform distribution and comfort batten series features, latest LED which delivers consistent light output with wide voltage protection range, stable color start, Extruded Aluminium housing, Energy efficient, Flicker free start, In-built driver unit Suitable for wall and ceiling mounting using brackets (supplied along with the Luminaire to be tested as per Standard Specification IEC 60598-2-1 / IS: 10322(Parts/Sec-1), to establish conformity of the product(s) to the requirements with the following specifications:- (a) Size :- 4 ft (b) IP rating = IP 20 (c) Power factor= min 0.9 (d) CRI= max 80% (e) Surge Protection = 3KV (f) LED Driver should be complete with all standard protections as per design of Manufacturer. (g) Voltage operating range: 140-270V (h) THD = max10% (j) Lumen Efficacy= min 110 Lumen/Watt
Supply & Fixing Smart bright Batten Series, LED luminaire using LED 20 watt with diffuser which ensures uniform distribution and comfort batten series features, latest LED which delivers consistent light output with wide voltage protection range, stable color start, Extruded Aluminium housing, Energy efficient, Flicker free start, In-built driver unit suitable for wall and ceiling mounting using brackets (supplied along with the Luminaire to be tested as per Standard Specification IEC 60598-2-1 / IS: 10322(Parts/Sec-l), to establish conformity of the product(s) to the requirements with the following specification:- (a) Size :- 4 ft (b) IP rating = IP 20 (c) Power factor= min 0.9 (d) CRI= max 80% (e) Surge Protection = 2.5KV (f) LED Driver should be complete with all standard portections as per design of Manufacturer. (g) Voltage operating range: 140-270V (h) THD = max 20% (j) Lumen Efficacy= min120 Lumen/Watt (k) CCT=4000K
Supply & Fixing Smart bright Batten Series, LED luminaire using LED 10 watt mirror with diffuser which ensures uniform distribution and comfort batten series features, latest LED which delivers consistent light output with wide voltage protection range, stable color start, Extruded Aluminium housing, Energy efficient, Flicker free start, In-built driver unit suitable for wall and ceiling mounting using brackets (supplied along with the Luminaire to be tested as per Standard Specification IEC 60598-2-1 / IS: 10322(Parts/Sec-l), to establish conformity of the product(s) to the requirements with the following specifications:- (a) Size :- 2 ft (b) IP rating = IP 20 (c) Power factor= min 0.9 (d) CRI= max 80% (e) Surge Protection = 2.5KV (f) LED Driver should be complete with att standard portections as design of manufacturer (g) Voltage operating range: 140-270V (h) THD = max 20% (j) Lumen Efficacy= min 900 Lumen/Watt (k) CCT=6500K
S&F Bulk head endura LED light fitting complete with and including 10 Watt LED and making necessary electric connection with copper conductor of suitable size and accessories & length complete all as specified and as directed with the following specifications:- (a) Size:-205mm x 70mm x 100mm (b) Main Current - 0.045 A (c) Power factor:- ≥0.95 (d) CRI: ≥80 (e) Surge Protection :- 4 KV (f) Voltage operating range: 120-270V (g) THD - ≤ 15% (h) Driver efficiency :- 90% (j) Lumen Efficacy:- 100 lm/w (k) Life (Hrs) :- 35,000 (l) CCT:- 4000/6500K (IP Rating) : IP65
Supply & Fixing Smart bright Batten Series, LED luminaire using LED 22 watt with diffuser which ensures uniform distribution and comfort batten series features, latest LED which delivers consistent light output with wide voltage protection range, stable color start, Extruded Aluminum housing, Energy efficient, Flicker free start, In-built driver unit suitable for wall and ceiling mounting using brackets (supplied along with the Luminaire to be tested as per Standard Specification IEC 60598-2-1 / IS: 10322(Parts/Sec-l), to establish conformity of the product(s) to the requirements with the following specifications:- (a) Size :- 4 ft (b) IP rating = IP 20 (c) Power factor= min 0.9 (d) CRI= max 80% (e) Surge Protection = 2.5KV (f) LED Driver should be complete with att standard protections as design of manufacturer. (g) Voltage operating range: 120-240V, 50 Hz (h) THD = max 20% (j) Lumen Efficacy= min100 Lumen/Watt (k) CCT=4000K
Supply & Fixing Smart bright Batten Series, LED luminaire using LED 22 watt with diffuser which ensures uniform distribution and comfort batten series features, latest LED which delivers consistent light output with wide voltage protection range, stable color start, Extruded Aluminium housing, Energy efficient, Flicker free start, In-built driver unit suitable for wall and ceiling mounting using brackets (supplied along with the Luminaire ti be tested as per Standard Specification IEC 60598-2-1 / IS: 10322(Parts/Sec-l), to establish conformity of the product(s) to the requirements with the following specifications:- (a) Size :- 4 ft (b) IP rating = IP 20 (c) Power factor= min 0.9 (d) CRI= max 80% (e) Surge Protection = 2.5KV (f) LED Driver should be complete with all standard protections as per design of Manufacturer. (g) Voltage operating range: 120-240V (h) THD = max 20% (j) Lumen Efficacy= min100 Lumen/Watt (k) CCT=6500K
S&F LED light fitting square 2'x2' , 30 watt, 3000 lumen, Cool white, 6500K, THD max 10 % ,Voltage operating range: 140-270V, Surge Protection :- 2.5 to 3.5KV, CRI min 80% warm white along with fixture Surface / Recessed /Pendent mounting LED luminaires with diffuser, channel Luminaires , connector block, etc . Complete with all accessories internally pre-wired and including round wooden block, connecting up with three core flexible copper conductor cable of suitable size and length complete all as specified and directed .
S&F LED light fitting square 2'x2', 30 Watt, 3000 lumen, Warm, white 5700K, THD max 10 % ,Voltage operating range: 140-270V, Surge Protection :- 2.5 to 3.5KV, CRI min 80 % warm, white along with fixture Surface / Recessed /Pendent mounting LED luminaires with diffuser, channel Luminaires , connector block, etc . complete with all accessories, internally pre-wired and including round wooden block, connecting up with three core flexible copper conductor cable of suitable size and length complete all as specified and directed .
Supply & fixing, in repair, LED light down lighter by recess or surface mounted 12 Watt, warm white/cool white, circular/Square, 1200 lumen with fixing arrangemnts on ceiling complete all as specified & directed with the following specifications:- (a) Size :- dia 180mm x26 mm thick for circular and 180mmx180mm x6mm for Square (Shape as per Site requirements either square or circular) (b) IP rating = IP 20 (c) Power factor= min 0.9 (d) CRI= max 80% (e) Surge Protection = 2.5KV (f) LED Driver should be complete with all standard protections as per design of Manufacturer. (g) Voltage operating range: 140-270V (h) THD = max 20% (j) Lumen Efficacy= min1200 Lumen/Watt (k) CCT=4000/6500 (CCT will be as per site requirement either 4000 or 6500)
Supply & fixing, in repair, LED light down lighter by recess or surface mounted 18 Watt, warm white/cool white, circular/Square, 1200 lumen with fixing arrangemnts on ceiling complete all as specified & directed with the following specification:- (a) Size :- dia 220mm x26 mm thick for circular and 220mmx220mm x6mm for Square (Shape as per Site requirements either square or circular) (b) IP rating = IP 20 (c) Power factor= min 0.9 (d) CRI= max 80% (e) Surge Protection = 2.5KV (f) LED Driver should be complete with att standard protections as design of manufacturer. (g) Voltage operating range: 140-270V (h) THD = max 20% (j) Lumen Efficacy= min1800 Lumen (k) CCT=4000/6500 (CCT will be as per site requirement either 4000 or 6500)
Supply & fix, in replacement, LED Light Luminaire 25 Watt with 2500 or more lumen warm white, surge protection device upto 4KV, IP65 or more, IK07 or more, potted driver suitable for 120 to 270 V, 50 Hz & 100 lm /w light engine driver base pole adapter, powder coated pressure die cast aluminium with heat resistant toughened glass with lens type,GI pipe 40 mm dia medium Grade not less than with 1.2 m.long in any shape with 2 nos of pole fitting clamps made out of MS flat , nuts and bolts and painting with aluminum paint with the following specification:- (a) Weight - 2.8 kg (b) Current :- 0.120 A (c) Power factor:- ≥ 0.95 (d) CRI:- ≥70 (e) Surge Protection :- 4KV (f) LED Driver should be complete with all standard protections as per design of Manufacturer. (g) THD - ≤ 10 % (h) System Lumens -2600lm/Watt (j) Life (Hrs) :50,000 (k) CCT:- 6500k
Supply & fix, in replacement, LED Light Luminaire 45 Watt with 4500 or more lumen, warm white, surge protection device upto 4KV, IP65 or more, IK07 or more, potted driver suitable for 180 to 270 V, 50 Hz, light engine driver base pole adapter, powder coated pressure die cast aluminium with heat resistant toughened glass with lens type, GI pipe 40 mm dia medium grade not less than with 1.2 m. long in any shape with 2 nos of pole fitting clamps made out of MS flat , nuts and bolts and painting with two coats of aluminium paint over a coat of primer with the following specification:- (a) Weight- 2.8 kg (b) Current :- ≤ 0.215 (c) Power factor:- ≥ 0.95 (d) CRI:- ≥70 (e) Surge Protection :- 4KV (f) LED Driver should be complete with all standard protections as per design of Manufacturer. (g) THD - ≤ 10 % (h) System Lumens min 4850 lm/Watt (j) Life (Hrs) :- 50,000 (k) CCT:- 6500K
S&F in repairs LED Bulb 230V AC 7/9 watt cool day light 4000K heavy duty Base B-22 complere all as specified and directed.
S&F in repairs LED Bulb 230V AC 10/12 watt cool day light 6500K heavy duty Base B-22 thred type or as required at site complere all as specified and directed.
S&F in repairs LED Bulb 230V AC 9 watt cool white light 6500K heavy duty thred type, LED BULB MOTION SENSINGB22 or as required at site complere all as specified and directed.
S&F decorative wall light fitting made up of Polycarbonate ,Cylindrical shape ,with LED lamp 9 Watt complete with fixing arrangements on wall complete all as specified and directed
Notes for items related to LED light fittings : (a) LED CHIP, DRIVER & HOUSING shall be in the same MAKE . (b) DRIVER COMPLIANCES WITH IS LUMINAIRE CERTIFIED BIOLOGICAL TEST REPORT BY OEM LAB APPROVED BY NATIONAL TEST HOUSE. (c) NABL testing Certificate shall be produced at the time of Make approval by the GE. (d) Bidders shall submit LM-80 Report for LEDs and LM-79 report from NABL accredited Lab. (e) Contractor shall furnish a replacement warranty of two years for LED light fittings complete including lamps from the certified date of completion of CA. (f) The product will be replaced free of cost by the contractor in the following cases:- (i) Manufacturing defects. (ii) Failure due to mechanical and electrical impact. (iii) Drop in lumen (or Lux) below 90% of claimed values of lumens (or lux ) at 1m of the LED/Luminaires. (iv) All LED light/luminaire must meet the provisions laid down in IS-16101,16102 Part-I/II, 16103 Part-I, 16104, 16105, 16106, 16108/2012 and 15885 Part-II section 13. (g) Minor items required for completion of job are deemed to be included in the unit rate quoted by contractor. Nothing extra shall be payable on this account.
M&L GI Tubes, 40 mm dia, medium grade, galvanised, with all fitting , laid in trenches for protection of cable in road /drain crossing complete all as specified and as directed.
S&F in replacement metal sheet enclosure distribution boards, double door factory made VTPN 4 way 3 phase 415 volts 4 way with 200 amps rating copper bus bar and PVC insulated copper jumpers of suitable size from the MCCB to the out going circuits one incoming MCCB 100 amps and MCB TP 63 A -02 Nos,MCB SP -04 Nos circuits comprising of 3 phase 4 wire of suitable rating complete all as specified and directed.
M&L , in replacement, for earthing complete with galvanised steel earth plate electrode 600x600x6.0mm thick directly burried in the ground (earth pit not less than 2.25M deep below ground level) with top edge of earth plate not less than 1.50M deep below normal ground level, connected to galvanised iron wire 4mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, 15mm bore GI pipe medium grade including necessary fittings for protection of earthing wire, watering pipe 20mm bore GI medium grade, concrete chamber in PCC (1:4:8) type D-2 using 40 mm grade aggregate, coping shall be in PCC (1:3:6) type C-1 using 20 mm grade aggregate and internal surfaces of concrete chamber shall be given 12mm thick plaster in CM (1:4), funnel with wire gauge of 22 gauge (0.63 mm) 8 mesh per linear including 50mm thick cover of RCC (1:2:4) type B-1 using 20mm grade stone aggregate reinforced with 8mm MS deformed bar @ 75 mm C/C both ways, char coal dust and common salt all as shown in electrical plate No. 3 of SSR Part-I (2009) including all necessary excavation & earth work and removal of surplus soil to a distance n. exc 50M and providing connection points with MS/ GI bolts & washers as required and connection from earth test point to earth electrode with same GI earth wire alongwith protection pipe and testing on completion complete all as specified and directed. Note:- GI wire and protection pipe from earth electrode to test point max upto 7.50M shall be deemed to be included in the unit rates as quoted by the contractor.
Schedule of credit amount of Rs 1,14,898.00 to be deducted during AOC
VEENUS ENGINEERS (BID ID -3104583)
C L BHATIA (BID ID -3104750)
New Era Engineers (BID ID -3102794)
S R BUILDERS AND SUPPLIERS (BID ID -3118281)
kailash chawla (BID ID -3115697)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .