Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹76.0 LAccepted-AOC NEIKUPPI VILLAGE VENGAPAKKAM POST KALPAKKAM 603 102 KANCHEEPURAM DIST | KALPAKKAM | KANCHEEPURAM | TAMIL NADU | 603102 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹80.0 L+₹2.6 L (3.42%)Rejected-AOC NO 03 45 NEIKUPPI VILLAGE VENGAPAKKAM POST KALPAKKAM CHENGALPATTU DISTRICT 603 102 | KALPAKKAM | CHENGALPATTU | TAMIL NADU | 603102 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹80.2 L+₹2.9 L (3.71%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹84.6 L+₹7.3 L (9.43%)Rejected-AOC NO 21 BRAMIN STREET KORATTUR CHENNAI 600080 | CHENNAI | CHENNAI | TAMIL NADU | 600080 | L4 | Rejected-AOC Rejected | |
| 5 | L5₹88.9 L+₹11.5 L (14.9%)Rejected-AOC D 3 7TH BLOCK JAIN GREEN ACRES DHARGA ROAD ZAMIN PALLAVARAM CHENNAI 600043 | CHENNAI | CHENNAI | TAMIL NADU | 600043 | L5 | Rejected-AOC Rejected |
Tender Value
₹84 L
EMD Value
₹1.5 L
Closing Date
26 Jul 2022, 6:00 pmClosed
Commander Works Engineers Navy
Commander Works Engineers Navy Military Engineer Services Fort St George Rajaji Salai Chennai 600 009
82507 SPECIAL REPAIRS TO CERTAIN UNITS OF MACKERAL BUILDINGS AT PTC KALPAKKAM UNDER AGE (I) NAVY CHENNAI
2022_MES_530158_1
CA No.CWE/NAVY/CHN/82507/E8 of 2022-23
Open Tender
Civil Works
Item Rate
240 days
CHENNAI
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹1,000
AGE(I) NAVY CHENNAI
₹1.5 L
Yes
27 Aug 2022
10 Jun 2022
27 Jul 2022
10 Jun 2022
26 Jul 2022
1 Jul 2022
11 Jun 2022 - 27 Jun 2022
Amount
Demolition cement concrete (unreinforced) in ground floors and paving not exceeding 15cm thick (below & above ground level)
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided including padding concrete on roof all as specified and directed.
Material and labour for applying epoxy water proofing treatment for sunken floor over and including rendering 15mm thick on fair faces of brick work or concrete surfaces with cement plaster 1:3 with WPC @ 2% by weight of cement (Note : Water proofing compound will be measured and paid separately) including finished even and smooth without using extra cement.
Material and labour for PCC 1:5:10 type, E-2 (using 40mm graded aggregate) as in mass concrete as in sunken floor.
Material and labour for 25mm thick PCC 1:2:4 type B0 (12.5mm graded stone aggregate) as in screed bed over sub base.
Dismantling of wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises including removing of all the debris to a distance not exceeding 2 km out side the base at the disposal of the contractor.
Material and labour for glazed ceramic coloured tiles 350 x 250mm x7mm/450 X 350 X 7mm thick as in skirting/dados set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick backing coat on fair faces of brick work/concrete in CM 1:4 to receive tiles as in dado complete all as specified and directed.
Supply and Fix Coloured non skid ceramic tiles of Size 600 x 600mm , 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0. 18 sqm but not exceeding 0.38 sqm, in floors, skirting's etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed in CM 1:6 complete all as specified and directed.
All as per item No 9 here in before but in skirting's
Material and labour Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) joint free tiles, area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed in CM 1:6 complete all as specified and directed.
Material and labour 10-15 mm thick brick tiles of size 230mm x 75mm laid in cement mortar (1:6) 15mm thick complete all as specified and directed.
Cutting grooves in brick/concrete wall, 75mm wide and 65mm deep and shaping horizontal face of grooves with cement mortar 1:3 complete all as specified and as directed.
Removing of debris any description obtained from demolition beyond the lead included in the rates including loading unloading to a distance exceeding 1.5Km and not exceeding 2.00 KM out side defence land.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc and applying cement slurry @3Kg/Sqm over cleaned roof surface and providing 5 mm thick screed in cement mortar 1:4 with water proofing compound at the rate of 2% by weight of cement to have a smooth surface for laying of water proofing membrane complete all as specified and as directed by the Engr-in -charge. Note : WPC will be measured and paid separately
Material and labour for PCC 1:2:4 type B-0 using 12.5mm graded stone aggregate as in roof kerbs or mud stops, rounded or chamfered on edges work complete all as specified and directed.
Material and labour PCC 1:3:6 type C1 (using 20 mm graded aggregate) as in padding concrete to maintain required slope including coving to junctions of parapet and roofs complete all as specified and directed.
Material and labour for rendering 15mm thick on fair faces of brick work or concrete surfaces with cement plaster 1:3 with WPC @ 2% by weight of cement finished even and smooth without using extra cement complete all as specified and directed. (Note : Water proofing compound will be measured and paid separately)
Material and Labour for APP polymeric water proofing membrane 3kg per sqm min 3 mm thick reinforced with polyester non woven fabric wt not less than 150 gms/sqm laid over roof surface with 100 mm over lap and including vertical surfaces upto required height and tucking into grooves and sealing complete with thermo fusion, torch application over a tack coat of hot bitumen 85/25 @ 1.2 kg/sqm over compatible primer at 0.40ltr/sqm as manufacturer's instructions complete all as specified and as directed.
Material and labour for Cement concrete tiles 25 x 25 x 22mm thick machine pressed, set jointed and pointed in neat cement slurry in floors with grey cement and pigments over a coat of 20mm thick screed bed in CM 1:6 complete all as specified and as directed.
Supply only integral water proofing compound complete all as specified and as directed.
Taking down chowkhats or frame with shutters (without taking off shutters from the frames) not exc 1.5 sqm each complete all as specified and as directed.
Taking down Chowkhats or frames exceeding 1.5 Sqm but not exceeding 4 Sqm each(without taking off shutters from the frames) complete all as specified and as directed.
Taking down shutters of any description exceeding 1 sqm and not exceeding 2 Sqm complete all as specified and as directed. .
Taking down shutters of any description not exc 1 sqm complete all as specified and as directed.
Supply and Fix Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube as per specification & drawing complete all as specified and as directed.
Supply and Fix Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and jointed together with solvent cement, supplying & fixing in the frame at site as per specification & drawing.
Supply and Fix Second class hard wood plain, solid, straight chowkhats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed.
Supply and Fix 35mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides including 6mm thick teak wood lipping complete all as specified and as directed.
Material and labour 35mm thick 2nd class hard wood plain framed panelled shutters (two panels) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS:1003 (Part1),kiln seasoned and chemically pressure treated, all as specified and directed.
Supply and Fix 30 mm thick second class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc., (without sash bars) chamfered or rounded, fitted with cut and mitred beads for securing glass etc., sizes of members of shutters as specified in SSR Pt I Section 8, clause 8.24 (a)
Material and labour Cup boards shutters made with 18/19 mm thick prelaminated particle board with decorative lamination on one side and other side balancing white lamination medium density, exterior grade, including 6 mm teak wood lipping all as directed.
Supply and Fix in repairs 18/19 mm thick prelaminated particle board , interior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination, fixed with screws to timber frame work as in cup board shelves
Supply and Fix sheet glass ordinary quality 4mm thick, in squares exc. 0.5 sqm each pane complete all as specified.
Supply and Fix sheet glass ordinary quality 4mm thick, in squares not exceeding. 0.5 sqm each pane complete all as specified and directed by Engineer in Charge
Supply and Fix in repairs Aluminium alloy wire cloth, 0.45 mm dia of wire and average width of aperture 1.40 mm and fixed with stainless wire staples complete all as specified and directed by Engineer in Charge
Supply and Fix Aluminium alloy wire cloth, 0.45 mm dia of wire and average width of aperture 1.40 mm and fixed with stainless wire staples complete all as specified and directed by Engineer in Charge
Supply and Fix 75 mm butt hinges, medium weight, stainless steel fixed complete all as specified and directed by Engineer in Charge
Supply and Fix 100 mm butt hinges, medium weight, stainless steel fixed complete all as specified and directed by Engineer in Charge
Supply and Fix 150 mm size, Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed by Engineer in Charge
Supply and Fix 200 mm size aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed by Engineer in Charge.
Supply and Fix 300mm long Aluminium, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts of extruded section complete all as specified and directed by Engineer in Charge.
Supply and Fix 150mm long Aluminium, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts of extruded section complete all as specified and directed by Engineer in Charge.
Supply and Fix magic eye15mm dia steel body suitable for 35 to 40 mm thick doors with all necessary fittings complete all as specified and directed by Engineer in Charge.
Supply and Fix Mild steel Angles, bars, flats etc., as in supports for stiffening of fencing, wall ties, hold fasts, clamps, plain angle cleats for securing purlins and similar small articles confirming to Fe 410-O 0r Fe 310-O complete all as specified and directed by Engineer in Charge.
Supply and Fix in repair aluminium anodised tubular curtain rail 20mm dia complete all as specified and directed by Engineer in Charge.
Supply and Fix aluminium anodised, brackets (designer pattern) for curtain rods in repairs complete all as specified and directed by Engineer in Charge.
Supply and Fix in repair aluminium anodised tubular rail 20mm dia D type 60cm long between flanges including per pair brackets for each towel rail complete all as specified and directed by Engineer in Charge.
Supply and Fix 150 mm door stopper of aluminium alloy body, with rubber bush complete all as specified and directed by Engineer in Charge.
Supply and Fix 300mm mild steel ordinary rat tail rod pattern springs incl roller and roller plates complete all as specified and directed by Engineer in Charge.
Supply and Fix in repair aluminium hat pegs solid body 125mm to 175mm long complete all as specified and directed by Engineer in Charge.
Supply and Fix in repair vitreous china squatting pan "Orissa" pattern size 580 x 440mm white with 'P' or 'S' trap front or back inlet with integral foot rest (excluding flushing cistern and flush pipe), squatting pan including connection to trap and flushing pipe, ant syphonic pipe etc complete incl making good to floor complete all as specified and directed by Engineer in Charge.
Supply and Fix in repairs Vitreous China wash down water closet pan (pedestal pattern), white (excluding , low level flushing cistern and Flush pipe of 32mm dia but including seat cover) complete all as specified and directed.
Supply and Fix in repairs PVC valve less flushing cistern low level 10 litres capacity with syphonic action type with inlet ball valves, float and handle and connections to pipes and fixing of chain and pull (or) lever including brackets and 32mm dia PVC flush pipe of 60cm long complete all as specified.
Supply and Fix in repairs Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified.
Supply and Fix in repair vitreous china, wash hand basin white flat back size 550 x 400 mm white complete waste, chain and pug and porcelain stopper including bracket complete all as specified and directed by Engineer in Charge.
Supply and Fix 32 mm bore brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipes or connections including necessary packing union and cap complete all as specified and directed by Engineer in Charge.
Supply & fixing fancy type pillar tap 15mm dia, cast copper alloy with capstan heads, chromium plated screwed down high pressure with or without lettered 'Hot or Cold' with long screwed shank and fly nut screwed for iron pipe & fixed in repairs complete all as specified and directed by Engineer in Charge..
Supply and Fix for 32 mm bore High density polyethylene pipes (HDPE) of pressure rating 6Kgf/cm2 fixed compete to in walls, floors, ceilings etc complete all as specified and directed by Engineer in Charge.
Supply and Fix in repair bib taps concealed type with long shank and cup of fancy type, chromium plated screwed down high pressure with crutch or butterfly handle screwed for iron pipes of 15mm bore complete all as specified and directed by Engineer in Charge.
Supply and Fix in repair PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed by Engineer in Charge.
Supply and Fix PVC (SWR) multiple Floor trap of 75 mm outlet plain with grating including jointing with solvent cement complete all as specified and directed by Engineer in Charge.
Supply and Fix in repair Angle valves fancy type, chromium plated cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe of 15mm bore complete all as specified and directed by Engineer in Charge.
Supply and Fix in repairs 15mm bore concealed stop valves cast copper alloy fancy type screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed by Engineer in Charge.
Supply and Fix in repair Brass chromium plated shower rose 125mm size, with or without swivel joints, including fixing to steel pipe or union complete all as specified and directed by Engineer in Charge.
Supply and Fix in repairs sheet glass shelf assembly consisting of 5.5mm thick sheet glass 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed by Engineer in Charge.
Supply and Fix soap dish, vitreous China white, approximate size 160x 160x90mm complete all as specified and directed by Engineer in Charge.
Supply and Fix kitchen plate rack made of stainless steel including bedding in cement mortar on to wall or including fixing cantilever brackets size 910 x 790 x 255 mm complete all as specified and directed by Engineer in Charge.
Taking down cement plaster on brick walls including racking out joints, hacking for key, scrubbing down with water etc.
Material and labour Rendering for 10mm thick in cement mortar (1:6) on other than fair faces of internal bricks or concrete surfaces finished even and smooth with using extra cement all as specified and s directed..
Material and labour for rendering 15 mm thick in two layers 10 mm thick backing coat in cm 1:6 and 5mm thick finishing coat in cm 1:4 . mixed with water proofing @ 2% by weight of cement with rough cast plasters finishes complete all as specified and directed by Engineer in Charge. (Note :- WPC will be measured separately).
Material and labour Rendering 5mm thick on ceiling in CM 1:3 finished even and smooth without using extra cement complete all as specified and directed by Engineer in Charge.
Material and labour for rendering 15 mm thick in two layers 10 mm thick backing coat in cm 1:6 and 5mm thick finishing coat in cm 1:4 . mixed with water proofing @ 2% by weight of cement finished even and fair complete all as specified and directed by Engineer in Charge.. (Note :- WPC will be measured separately).
Material and labour for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:3 with WPC including finished even and smooth without using extra cement complete all as specified and directed by Engineer in Charge. (Note : Water proofing compound will be measured and paid separately)
Material and labour for preparing newly plastered surfaces and applying two coats of distemper oil emulsion over coat of primer on surfaces of walls including 3mm the wall care putty complete all as specified and directed by Engineer in Charge. on walls complete all as specified and directed by Engineer in Charge.
Material and labour preparation of newly plastered surfaces of wall and applying three coats of white wash complete all as specified and directed by Engineer in Charge.
Material & Labour preparation of new plastered surface and finishing walls with Acrylic Smooth exterior paint of required shade (two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and as directed.
Material and labour preparing newly plastered surfaces of ceilings and applying three coats of white wash complete all as specified and as directed.
Material and labour for complete removal and preparation of existing treatment and finishing walls with Acrylic Smooth exterior paint of required shade (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and as directed.
Material and labour complete removal of existing treatment & preparation on walls and applying two coat of distemper oil emulsion over a coat of primer on surfaces of walls including 3mm the wall care putty on walls complete all as specified and as directed.
Material and labour for preparing old plastered surfaces of ceilings and applying one coat of white wash complete all as specified and as directed..
Material and labour for preparing old plastered surfaces of walls and applying one coat of white wash complete all as specified and as directed..
Material and labour for preparation of new or previously untreated wooden surfaces of any description, exceeding 10 cm width or girth, not otherwise described and applying two coats of Synthetic Enamel paint over a coat of pink primer complete all as specified and as directed..
Material and labour for preparation of old treated surfaces of any description, exc 10 cm in width or girth when unconnected with other work or painted in different tint finishing coat with synthetic varnish for handrail complete all as specified and as directed..
Taking up or down steel tubing 20mm dia bore and connection complete all as specified
Taking up or down steel tubing 25mm dia bore and connection complete all as specified
Taking up or down steel tubing 40mm dia bore and connection complete all as specified
Cutting chases, pinning in , for concealed water tubing on brick or stone walls, making good to facing where required and pointing in cement mortar 1:3, not exc 10 cm girth complete all as specified and directed.
Supplying and laying of CPVC pipes of outer dia 20mm dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.
Supplying and laying of CPVC pipes of outer dia 25mm dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.
Supplying and laying of CPVC pipes of outer dia 40mm dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.
Supplying and fixing CPVC Brass Elbow (3/4 x 1/2) as in special fittings complete all as specified and directed.
Supplying and fixing CPVC Brass Tee of 20mm dia as in special fittings complete all as specified and directed.
Supplying and fixing CPVC 40mm dia Male Brass Threaded Adaptor (MTA/ MBTA) ) as in special fittings complete all as specified and directed.
Supplying and fixing CPVC 40mm dia UNION as in special fittings complete all as specified and directed.
Supplying and fixing CPVC 25mm dia UNION as in special fittings complete all as specified and directed.
Supply and Fix in repairs Gun metal globe or gate valve of 40 mm dia of pipe with Iron wheel head, screwed both end for Iron pipe one fixed complete all as specified and directed..
Taking down rain water pipe and sewage pipe of any size of pattern including all fittings, heads, shoes, bends etc complete all as specified and directed..
Supply and Fix for 110mm dia bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed..
Supply and Fix for 75mm dia bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed..
Supply and Fix for 75mm dia bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or floors complete all as specified and directed.
Supply and Fix for 110mm dia bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or floors complete all as specified and directed.
Supply and Fix for 75mm dia bore PVC (SWR) branch piece, single (Single 'Y') equal or unequal with access door complete all as specified and directed.
Supply and Fix for 110mm dia bore PVC (SWR) junction single, (Single 'T') equal or unequal with access door complete all as specified and directed.
Supply and Fix for 75mm dia bore PVC (SWR) bends any radius complete all as specified and directed.
Supply and Fix for 110mm dia bore PVC (SWR) bends any radius complete all as specified and directed.
Supply and Fix for 110mm dia bore PVC (SWR) vent cowl complete all as specified and directed..
Supply and Fix for 75mm dia bore PVC (SWR) vent cowl complete all as specified and directed..
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in Soft/ Loose soil complete all as specified and as directed.
Material and labour hard-core of gauge exc 63mm deposited ,spread &levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and as directed..
Material and labour 75 mm thick Cement concrete type C2, 1:3:6 (using 40 mm graded stone aggregate) in sub base of flooring/ hard standing/pavings/plinth protections complete all as specified and as directed.
Material and labour treating the soil under plinth protection at the rate of 5.0 ltr of emulsion per sqm of surface area complete all as specified and as directed.
Material and labour treating the soil along with external perimeter of building at the rate of 2.25. ltr of emulsion per mtr of the perimeter walls complete all as specified and as directed.
Material and labour Providing ATT by injecting at point of contact of wood work by chemical emulsion (oil or kerosene based solution)@ 0.5 lit/ hole by drilling 6mm dia holes at downward angle of 45 degrees at 150 mm centre to centre and sealing the same all as specified complete all as specified and as directed.
Material and labour Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm part including drilling and plugging 12mm dia holes with cement mortar 1:2 to match the existing floors complete all as specified and as directed.
Demolition of stone slabs and tiles of any description or any thickness in floors, skirting's, risers etc laid ,bedded and pointed in any mortar complete all as specified and as directed.
Material and labour 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over rendering 15 mm thick in CM 1:6 complete all as specified and as directed.
Material and labour 20mm thick Granite (of any type) work (table rubbed and polished) in Skirting for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed.
Providing edge moulding/ Full nosing to 18-20mm thick Granite stone of counters vanities etc. including machine polishing to edge to give high gloss finish etc. complete all as specified and as directed.
Supply and Fix Cement Concrete tiles 200 x 150 x 20 mm thick machine pressed, jointed and pointed in neat cement slurry in risers and cut and polished with grey cement and pigments including rendering 15mm thick in CM 1:4 complete all as specified and as directed.
Supply and Fix Cement Concrete tiles 30 x 30 x 20 mm thick machine pressed, jointed and pointed in neat cement slurry in floors and cut and polished with grey cement and pigments including 20mm cement screed in CM 1:6 complete all as specified and as directed.
Supply and Fix Chequered cement concrete tiles bull nosed 30 cm x 30 cm x 20 mm thick, as in treads with grey cement and pigments, set, jointed and pointed in neat cement slurry in treads including 20mm cement screed in CM 1:6 complete all as specified and as directed.
Material and labour 2nd class hard wood plain fillets. square, rectangular or triangular in section, clean sawn, se-cured with screws exceeding 13 sqcm but not exceeding 25 sqcm complete all as specified and as directed.
Supply and Fix 100mm size, Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed.
Supply and Fix for ball catches of 8mm dia steel brass body and striking plates approved pattern fixing to the cupboard shutters, including lettering complete all as specified and as directed.
Supply and Fix in repairs Ball brass valves of 40mm dia, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule complete all as specified and as directed.
Supply and Fix in repair aluminium wardrobe hooks (single) solid body 50mm to 60mm long complete all as specified and as directed..
Supply and Fix sinks made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and as directed.
Supply and Fix Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed..
Supply and Fix 30 mm thick, 2nd class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass, gauge etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc size of member of shutter as specified in SSR Part-I Section 8 Clause 8.24(b), etc complete all as directed by Engineer-in-charge.
Supply and Fix 100 mm size aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and as directed.
Supply and fix 200mm long mild steel gate and shutter hooks and eye complete all as specified and as directed.
Supply and fix in repairs 200mm long mild steel gate and shutter hooks and eye complete all as specified and as directed.
Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
Material and labour brick work with sub class 'B' bricks straight or curved on plan exc 6 m mean radius built in CM 1 : 6 complete all as specified and as directed.
Material and labour Preparation of old painted wooden surfaces of any description, exceeding 10 cm width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and as directed.
Material and labour Preparation of old painted Steel surfaces of any description, exceeding 10 cm width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and as directed.
Material and labour Preparation of new painted steel surfaces of any description, exceeding 10 cm width or girth, not otherwise described and applying two coats of Synthetic Enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concert for brick surrounds, glazed with putty or fixed with beads complete all as specified and as directed.
Supply and Fix 75 mm butt hinges, medium weight, cold rolled mild steel and fixed complete all as specified and as directed.
Resecuring or easing and adjusting without taking down shutters of any description not exc 1 sqm each complete all as specified and as directed.
Demolition of Reinforced cement concrete (Reinforcement cut as required ) of any description and in any position not otherwise specifically provided including padding concrete on roof all as specified and directed.
Material and labour for Repair to broken/rusted RCC work such as fascia of roof slab, ceiling, chajjas, columns, beams etc upto required thickness with 'Ready Mix Reinforced acrylic fibre' cementitious mortar material (micro concrete) after cleaning & removing loose particles, grease, oil or other materials, applying 'epoxy zinc primer' over cleaned reinforced steel and providing a steel reinforcement cage covered with fibre mesh all as per manufacturer's instructions and finished the surfaces fair and smooth for building upto (G+2) stories including necessary scaffolding complete all as specified. Make : M/s Dr Fixit (Pidilite), Fosrock, Berger Paints or equivalent
Material and labour Cement concrete designer(chequred) tiles of size as directed by Engr-in-charge,20-25mm thick in floors with grey cement and pigments set and jointed in neat cement slurry and pointed in white or coloured cement to match including bedding layer of cement mortar 1:6, 20 mm thick for laying floor finishes complete all as specified and as directed.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and as directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) including fixture and fittings complete etc removing the materials for taking credit and making good the disturbed surface of wall/floor etc.
Taking down old/existing MCB DB SPN/ TPN with MCB's complete by disconnecting all as specified and directed.
Taking down old sub main wiring with 2runs/4runs of 4/6/10 sqmm aluminium/copper cables including making good disturbed surface complete all as specified and directed.
Point wiring with 1.5 sqmm (Nominal area) unsheathed multi-stranded copper conductor PVC insulated cable 1100 volts grade single core FRLS drawn into and including non-metallic rigid PVC conduit of 20 mm dia, concealed FRLS wiring, along with 1.5 sqmm unsheathed multi stranded copper conductor cable PVC insulated 1100 volts grade as earth continuity conductor connected to common earth dolly fixed to wall/ ceiling roof excluding Modular Metal flush box and white cover plate with frame the switches, sockets, fan regulator etc as required suitable for Modular type fitting /fixture etc witch shall be measured and paid separately all as specified and directed for :-
One light point controlled by one switch
One Ceiling fan/Exhaust fan point controlled by one regulator / switch.
One 3 pin socket outlet 5 amps socket on independent board
One 3 pin socket outlet 5 amps socket on same board
All as per item No 149 here in before but 3 pin socket outlet 15 amps sockets on independent board with 4sqmm multistranded copper PVC insulated cable.
One bell/buzzer point controlled by one push button
One light point controlled by two Nos of two way switches.
Supply and Fix switch modular 10 amps one way flush type 1 module complete all as specified and directed..
Supply and Fix switch modular 10 amps Two way flush type 1 module complete all as specified and directed.
Supply and Fix switch modular 10 amps one way flush type 1 module complete all as specified and directed.
Supply and Fix switch modular 10 amps Two way flush type 1 module complete all as specified and directed.
Supply and Fix switch modular 6 amps bell push flush type 1 module complete all as specified and directed.
Supply and Fix switch modular 25 amps one way flush type with neon indicator 1 module complete all as specified and directed.
Supply and Fix switch modular 16 amps one way flush type 1 module complete all as specified and directed.
Supply and Fix socket modular 2/3 pin 6 amps flush type 2 module complete all as specified and directed.
Supply and Fix socket modular 2/3 pin 6/16 amps flush type 2 module complete all as specified and directed.
Supply and Fix socket modular 2/3 pin 25 amps flush type 2 module complete all as specified and directed.
Supply and Fix only electronic modular fan regulator 120W step type 2 modular complete all as specified and directed.
Supply and Fix modular white cover plate with frame 1 module and Modular Metal flush box 1 Module complete all as specified and directed.
Supply and Fix modular white cover plate with frame 2 module and Modular Metal flush box 2 Module complete all as specified and directed.
Supply and Fix modular white cover plate with frame 3 module and Modular Metal flush box 3 Module complete all as specified and directed.
Supply and Fix modular white cover plate with frame 4 module and Modular Metal flush box 4 Module complete all as specified and directed.
Supply and Fix modular white cover plate with frame 6 module and Modular Metal flush box 6 Module complete all as specified and directed.
Supply and Fix modular white cover plate with frame 8 module and Modular Metal flush box 8 Module complete all as specified and directed.
Material and labour for sub main wiring (concealed) complete with two single core 4 Sqmm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through in and including 25 mm dia rigid non-metallic PVC conduit heavy grade and conduit accessories including 4 Sqmm FRLS PVC insulated unsheathed stranded copper earth cable connected to common earth dolly complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface all as specified and directed. Note: 3 run of 4 sqmm & one run of PVC conduit shall be measured as single unit
Material and labour for sub main wiring (concealed) complete with two single core 10 Sqmm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through in and including 25 mm dia rigid non-metallic PVC conduit heavy grade and conduit accessories including 10 Sqmm FRLS PVC insulated unsheathed stranded copper earth cable connected to common earth dolly complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface all as specified and directed. Note: 3 run of 10 sqmm & one run of PVC conduit shall be measured as single unit
Material and labour for sub main wiring (concealed) complete with two single core 16 Sqmm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through in and including 25 mm dia rigid non-metallic PVC conduit heavy grade and conduit accessories including 16 Sqmm FRLS PVC insulated unsheathed stranded copper earth cable connected to common earth dolly complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface all as specified and directed. Note: 3 run of 16 sqmm & one run of PVC conduit shall be measured as single unit
Supply and Fix ceiling rose 3 terminals PVC / Polycarbonate, isolated body complete all as specified and as directed.
Supply and Fix Bell, AC,230 Volts, single pole, Multi music type complete all as specified and as directed.
Supply and Fix Double Door Vertical TPN Distribution Box 4 way complete in SS enclosure with 200 amps rated busbar complete all as specified and as directed..
Supply and Fix MCCBs 415 Volt 100 Amps, 4 pole with 16KA breaking capacity complete all as specified and as directed.
Supply and Fix MCB DB SPN 12 way complete in SS enclosure double door type with 200 amps rated busbar complete all as specified and as directed.
Supply and Fix RCBO DP,100mA, 240 volts 63 Amps with Front face indication for earth leakage fault IP 20 protected terminals 35 sq mm terminals Sliding shutters complete all as specified and as directed by Engr-in-charge. Make:- Legrand Cat Part No 4113 35. or equivalent as mentioned in PS
Supply and Fix MCB SP 230 volts 5- 40 Amps with 10KA breaking capacity complete all as specified and as directed.
Supply and Fix MCB SP 230 volts 63 Amps with 10KA breaking capacity complete all as specified and as directed.
Supply and Fix LED light fitting 4feet,1x20w,a trendy wall mounted batten, with extruded aluminium housing, with integrated LED driver, etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed. Make: C&S ELECTRIC Cat Part No LTTB4F20WLED/W or equivalent as mentioned in PS
Supply and Fix LED light fitting 2 feet,1x10w,230v,a trendy wall mounted batten, with extruded aluminium housing, with integrated LED driver, etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed. Make: C&S Electric Cat Part N0:TTB2F10WLED/W or equivalent as mentioned in PS
Supply and Fix Energy saving new generation 10W LED IP65 bulkhead luminaries with opal diffuser complete all as specified and as directed. Make: C & S Cat Part No. SIRIUS/10 or equivalent as mentioned in PS
S & Material For Angle holder ,PVC /Polycarbonate type With LED bulb 9 Watt all as specified and Directed by Engineer in Charge
M/L for providing earthing complete with galvanised steel earth plate electrode 600 mm x 600 mm x6mm thick buried directly in ground earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level ,Alternate layers of charcoal) & common salt Crystal and connected to G I earth strip 25x4mm by means of bolts, nuts, check nuts & washers of copper and connecting to earth dolly all as shown in electrical plate No.3 of SSR Part I of 2009 & testing complete including 40mm dia light grade GI pipe upto 7.5mtr long, excavation in any type of strata, PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm with frame, test box , including 20 mm bore water pipe medium grade GI Tubing including GI Funnel , wire mesh etc. (NOTE :- Earth continuity conductor and GI protection pipe beyond 7.5m shall be measured and paid under the respective items )complete all as directed by Engineer- in charge.
M/L for providing earthing complete with copper plate electrode 600 mm x 600 mm x3.15mm thick buried directly in ground earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level ,Alternate layers of charcoal) & common salt Crystal and connected to Copper earth strip 20x3mm by means of bolts, nuts, check nuts & washers of copper and connecting to earth dolly all as shown in electrical plate No. 3of SSR Part I of 2009 & testing complete including 40mm dia light grade GI pipe upto 7.5mtr long, excavation in any type of strata, PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 (reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm with frame, test box , including 20 mm bore water pipe medium grade GI Tubing including GI Funnel , wire mesh etc. (NOTE :- Earth continuity conductor and GI protection pipe beyond 7.5m shall be measured and paid under the respective items ). complete all as directed by Engineer- in charge.
Supply and install, panel Sheet metal box size 0.7 x 0.45 x 0.18m for existing Energy meter indoor type dust and vermin proof fabricated out of CRCA sheet not less than 3.15 mm thick fixed on angle iron frame of size 50x50x6mm duly powder coated complete with all as specified and directed by Engr-in-Charge.
M/L for earth continuity conductor or copper strip 20x3 mm buried in ground / fixed on wall / drawn in 40mm dia light grade GI pipe complete with all as specified and directed by Engr-in-Charge.
Supply and fixing of single pole and neutral enclose with a two pin and earth plug and socket complete with one single pole MCB 240V, 20Amps complete all as specified and as directed.
Supply and Fix Water heater storage type 25 Ltrs capacity vertical type, 5star rating complete all as specified and as directed.
Remove of Ceiling Fan /Exhaust Fan and Electric Meter from Existing Place and Refixing after Servicing on Same Place all as specified and directed by Engr in Charge.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as specified and as directed by Engr-in-Charge
Cutting the existing wall for fitting colour for exhaust fan and making good disturbed surfaces inner and outer of wall Complete all as specified and as directed by Engr-in-Charge.
Supply laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (Heavy duty) with stranded aluminium conductor, 1100 volts grade, of size 3core 10Sqmm complete all as specified and as directed.
Supply and fixing Metal Box size 200 X140 X95 mm internal size with hinged door(L) with 1 No PVC connector 4 way 16 Amps and 1 Nos MCB SP 6 Amps including fixing bracket, Nut, Bolts etc complete Make : Sintex Cat part No GSJB2014 or Equivalent
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 m depth for foundations or laying under ground cable, pipes etc. and getting out in soft/loose soil etc. complete all as specified and directed by Engr-in-charge.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in any type of soil. Complete all as specified and directed by Engr-in-Charge.
Removing excavated soil to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.50 meter above the starting point complete all as specified and directed.
Supply and fixing High density poythelyne (HDPE) pipes of pressure rating 6kgf/ sq/ m of size 40 mm for cable protection laid in trenches complete all as specified and directed
Supply and Laid in trenches GI pipe Light grade 40mm dia as for Road Crossing of Cable complete all as specified and as directed.
Supply and fixing post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed.
Cutting the existing road for passing pipe and making good the disturbed surfaces by using 15 mm thick 1:4:8 in foundation type D-2 (using 40mm graded crushed stone aggregate) as in mass concrete complete all as specified exists complete all as specified.
Material and labour for Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width and setting in mortar, complete Type B1 1:2:4 of Using 20mm aggregate complete all as specified and as directed
Material and labour for telephone sockets special type complete all as specified and as directed.
Material and labour for TV sockets special Modular flush type complete all as specified and as directed.
Material and labour for PVC conduit 20 mm dia (For TV and data cable) complete all as specified and as directed.
Material and labour for Junction box (1 to 4 way) for TV/Tele wiring complete all as specified and as directed.
S Dilli
GV Foundations
kvs constructions
lakshmibuilders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .