Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance AT BATA GALI PHUSRO PO PHUSRO BAZAR DIST BOKARO | PHUSRO | BOKARO | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance AT DHORI G M COLONY DIST BOKARO JHARKHAND | BOKARO | BOKARO | JHARKHAND | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance AT PATEL NAGAR PO PHUSRO BAZA DIST BOKARO | PHUSRO BAZA | BOKARO | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹5.6 L
EMD Value
₹7,000
Closing Date
2 Oct 2024, 10:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Staff Officer (EnM)
Office of the General Manager, Dhori Area
Repair and maintenance of HT OH line 3.3 kV from Ambedkar Colony to Balubankar Sub-station and its adjacent colonies at River side under GM unit, Dhori Area
2024_CCL_318007_3
GM(D)/SO(EnM)/DA/2024-25/37
Open Tender
Electrical and Maintenance Works
Item Wise
10 days
GM Unit, Dhori Area
Please refer Tender documents.
2 documents required · 2 mandatory
₹7,000
3 Oct 2024
21 Sept 2024
3 Oct 2024
22 Sept 2024
2 Oct 2024
22 Sept 2024
22 Sept 2024 - 25 Sept 2024
Amount
Erection of steel tubular or rail pole strut in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling and secured with holding clamps, bolts, nuts, etc. as required
Erection of all aluminium conductor of 7/1.96 mm to 7/3.10 mm diameter including binding etc. as required.
Dismantling of over head lines comprising of copper/ aluminium over head conductor, G.I. wire, cross arms, insulators etc. as required
6 SWG GI wire
Erection of cradle guard as required
Supplying and erection of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required
Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle ( 20 mm X 600 mm ), 7/ 4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required
Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required
Erection of double pole 3 wire cross arm for 11KV/ 22KV/ 33 KV over head lines as required.
Erection of angle iron/ channel iron cross arm on wood/ RCC/ PCC/ steel tubular/ rail pole etc. as required
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared.
Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Supply of GOS 400A, 11KV grade vertical type
Fitting and fixing of GOS 400A, 11KV grade vertical type
Providing and making steel pole collar with cement concrete (1 cement : 3 coarse sand : 6 stone aggregate 20mm) of specified size and shape including form work, plastering if required, curing etc as required. (volume of pole/ pipe not to be deducted)
Applying priming coating with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work (second coat)
Painting with aluminium paint of approved brand and manufacture to give an even shade. Two or more coats on new work
Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required
Total impact of GST for the purpose of CTC
M/S UNNATI ELECTRICAL WORKS
M/S P S ENTERPRISES
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .