Loading…
Loading…
Tender ID
Tender Value
₹40.4 L
EMD Value
₹80,704
Closing Date
13 Feb 2026, 4:00 pmClosed
Executive Engineer
Office of Executive Engineer, Div IV, PWD Tonca
Electrical re-wiring for the existing Government Primary School at Punarvasan Sal in Bicholim Taluka.
2026_PWD_27593_1
31/1/2025-26/ASW-IV/EMN/PWD/50 LINE01
Open Tender
Electrical Works
Percentage
30 days
Tonca Caranzalem
Please refer to tender notice
3 documents required · 3 mandatory
₹6,000
Yes
₹80,704
Yes
6 Feb 2026
5 Feb 2026
16 Feb 2026
5 Feb 2026
13 Feb 2026
5 Feb 2026
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in recessed PVC conduit(heavy) with modular switch modular plates suitable size modular GI box of specified Category and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.;(a) Group A -- with Cat A Modular Accessories
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent recessed PVC conduit(heavy) of appropriate size as required.;(a) 2 x 1.5 sq.mm + 1 x 1.5 sq.mm earthwire (20mm Conduit)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent recessed PVC conduit(heavy) of appropriate size as required.;(b) 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earthwire (20mm Conduit)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent recessed PVC conduit(heavy) of appropriate size as required.;(c) 2 x 4 sq.mm + 1 x 4 sq.mm earthwire (20mm Conduit)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent recessed PVC conduit(heavy) of appropriate size as required.;(k) 4 x 10 sq.mm + 2 x 10 sq.mm earthwire (32mm Conduit)
Wiring for group controlled light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in recessed PVC conduit(heavy) and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Supplying and fixing 3 pin 5/6 A modular socket outlet and 5/ 6 A modular switch on board the modular surface/recessed PVC/GI modular box by suitably increasing its modular capacity modular plate and cover including connection painting etc. as required.;(a) Cat A
Supplying and fixing suitable size modular PVC box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 A modular socket outlet and 5/ 6 A modular switch connection painting etc. as required.
Supplying and fixing suitable size modular PVC box with modular plate and cover in front on surface or in recess including providing and fixing 4 nos 3 pin 5/6 A modular socket outlet and 4 nos 5/ 6 A modular switch connection painting etc. as required. The scope of work includes alternate arrangement if required as per site conditions to provide switches and sockets seperately above and below the table respectively. (For workstations);(a) Cat A
Supplying and fixing suitable size modular PVC box with modular plate and cover in front on surface or in recess including providing and fixing 1 no 6 pin 15/16 A modular socket outlet and 1 nos 15/ 16 A modular switch connection painting etc. as required. ( For workstations);(a) Cat A
Supply and erecting of 48 inch (1200mm sweep) ceiling fan double ball bearing type complete with all accessories.;(a) Cat A
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required;(a) Cat A
Installationearthing testing and commissioning of ceiling fan including wiring the down rod of standard length ( upto 30 cm) with 1.5 sq .mm FRFRLS PVC insulated copper conductor single core cable etc. as required.
Supplying and fixing extra down rod of 20 cm length GI pipe 15 cm dia heavy gauge including painting etc as required
Supply and erecting S type Stainless Steel fan hook fabricated out of 10 mm round bar complete as required.
Supplying and fixing following size modular GI box alongwith modular base and cover plate for modulator switches in recess etc. as required;(a) 1 or 2 Module ( 75 mm x 75 mm) Cat A
Supplying and fixing suitable size modular GI box with modular plate and cover in front on surface or in recess including providing and fixing required number of modular switches connection painting etc. as required. ( For group controlled points);(a) Cat A
Supply and erecting of 18 inch (450 mm sweep) exhaust fan with double ball bearings 1400 rpm heavy duty complete with all accessories.;(a) Cat A
Installation earthing testing and commissioning of exhaust fan upto 450 mm sweep in the existing opening including making the hole to suit the size of the above fan making good the damage connections testing commissioning etc as required
Supplying and fixing call bell/ buzzer suitable for single phase 230 V complete as required.;(a) Ding Dong Bell
Supplying and fixing following way TPN sheet steel double door Verticle type MCB distribution board 415 V on surface/ recess complete with tinned copper busbar neutral busbar earth bar dinnbar detachable gland plate interconnections phosphotized and powder painted including earthing etc. as required ( but without MCB/RCCB/Isolator)interconnection between incomer MCB and busbars of following ways (but without MCBs as required);(b) 8 way (8+24) double door Vertical type Cat A
Supplying and fixing following way TPN sheet steel double door Horizontal type MCB distribution board 415 V on surface/ recess complete with tinned copper busbar neutral busbar earth bar dinnbar detachable gland plate interconnections phosphotized and powder painted including earthing etc. as required ( but without MCB/RCCB/Isolator);(a) 4 way (4+12) double door Horizontal type Cat A
Supplying and fixing 6 A to 32 A C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required.;(a) SP Cat A
Supplying and fixing 63 A C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required.;(d) TP Cat A
Supplying and fixing 63 A C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required.;(e) TPN Cat A
Supply of 4 core armoured PVC/XLPE insulated PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) IS:7098(Part I) with latest amendments of following size.;4 Core 25 sq.mm
Supply of 4 core armoured PVC/XLPE insulated PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) IS:7098(Part I) with latest amendments of following size.;4 Core 35 sq.mm
Supply of 3 core unarmoured PVC/XLPE insulated PVC sheathed copper conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) IS:7098(Part I) with latest amendments of following size.;3 Core 2.5 sq.mm
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 120 sq.mm in the existing masonry open duct etc. complete as required
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 120 sq.mm direct in ground including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Inchargesand cushioning with screened sand bed of 20mm thick protective covering with bricks placed breadth-wise on top of cable all over the run( the brick protection shall cover the cable and project atleast 5 cms over the sides of the cable) and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required.;(a) In soily strata
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm on surface etc. complete as required
Supplying and making cable end terminations with brass compression gland and copper lugs for folowing sizes of 3 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade complete as required.;(1) 3 x 1.5/2.5 Sq. mm.
Supplying and making cable end terminations with brass compression gland and aluminium lugs for folowing sizes of 4 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade complete as required.;(7) 4 x 35 Sq. mm.
Supplying and fixing of following sizes of rigid PVC conduit alongwith accessories in surface(medium)/recess(heavy) including cutting the wall and making good the same in case of recessed conduit as required.;(a) 20 mm
Supplying and fixing of following sizes of rigid PVC conduit alongwith accessories in surface(medium)/recess(heavy) including cutting the wall and making good the same in case of recessed conduit as required.;(c) 32 mm
Earthing with GI earth pipe 2 mts long 40 mm dia medium class with ISI mark of approved brands including accessories and providing masonry enclosure with CI/RCC cover having locking /Lifting arrangement and watering pipe etc. (but without charcoal or coke and salt) as required as per the Earthing Drawing provided by the Engineer-Incharge.The scope of work includes the following: a) Excavation of pit of size not less than 1.0x1.0x 2.0 mtrs(min) and disposal of excavated soil. b) Class B GI pipe 40mm diameter as per specifications. c) Charcoal/salt as per specs ( paid seperately). d) Refilling the pit of size not less than 1.0x1.0x 2.0 mtrs(min) with soft black soil of minimum resistivity i/c transportation. e)Masonary chamber with proper foundation cover plate and locking arrangement. f) Testing of earth value with earth megger and certifications of its value. Aluminium tag with embossed earthing value to be attached to the pipe. g)watering arrangement(plumbing will be paid seperately).;(a) In soily strata
Extra for using salt and charcoal for pipe earth electrode as required( 65 Kgs of Charcoal and 5 Kgs of Salt).
Providing and laying earth connection from earth lectrode with4 mm dia copper wire in 15 mm dia GI pipe from earth electrode as required
Providing and fixing 4 mm dia copper wire on surface or in recess for loop arthing . as required
Supply of 4 feet 20 W single box/batten industrial type LED luminaire with CRCA body pre coated in white and pre wired for LED type complet with all accessories of make Crompton , model no IGP 131LT8-16 or Havells bearing Cat No. LHFYBYPNIA1W022/ Bajaj Bearing Cat No.BLRB-DB 118/Wipro bearing Cat No WIO 921208 or any approved brand including 1 No of of 4 feet 20 W LED tube of make crompton bearing Cat No. LTT8-20/Bajaj bearing Cat No.BLRB 18W CWc /Havells bearing Cat No.LHLDCLXUL8X020 or Wipro bearing Cat No. LL13-181-650 as required.( Equivalent to be approved by Engineer in charge). The LED tube should have a warranty of two years from the date of commissioning.
Supply installation testing & commissioning of LED 30/36 watts recessed full open 2x2 tile, care free uniform illumination having efficient high output LED of Make Crompton bearing cat no. LCTLRN-30-FO-CDL or Bajaj bearing Cat. No. BCTBLR36WLEDFPPCW or Jaguar Bearing Cat No. LSVR01S036XW or any approved equivalent make in hovels / Phillips etc. ( to be approved by Engineer-IN charge) complete with mounting arrangement, making cavity of required dimension and having 2 years replacement warranty complete as reqd.
Supply, installation, testing and commissioning of 36 watts or more LED Street light in Pressure die cast aluminium housing with polycarbonate cover having IP 65 class of protection or above having efficient hight output LED of make Greatwhite bearing cat No.LED-STL-38005, or Jaguar fittings bearing cat NoLSRT01S036XC or Bajaj bearing cat No. BRTFG 36W LED or any approved equivalent make ( to be approved by Engineer in Charge) complete with 40 mm dia GI pipe bend at an appropriate angle of length 80cms and having three years free replacement warranty complete as required.
Supplying and fixing DK thermoplastic Cable Junction Boxes130 x 130 x 77mm IP 66/69 weather proof for outdoor installation (with knockouts for cable entry) including connections etc & inbuilt 4 way stud type connectors of make Hensel cat no. DK 0604 G / spelberg and fixing of 32 mm dia Gi pipe including, clamps nut bolts, cement, sand, excavation for mounting etc. as required.
Transportation, Supply, installation, testing and commissioning of indoor type feeder panel fabricated in 14/16 SWG CRCA sheet, flush front. compartmentalised, dust and vermin proof, dully powder coated or painted floor mounted at a suitable height of 0.25 mtrs from ground and based on an angle frame of size cade 35mmx35mmx35mm size, cable entry from top /bottom for out going cables suitable for operation on 440V, 3 phase, 4 wire, 50 Hz supply complete 8 with interconnections with proper sizes of wires, copper wiring, lugs, earthing bus etc. The panel board shall comprise of the following INCOMING a) Sealable Metering compartment with 63 Amps, TP MCB & direct type energy meter -1 set b) RYB indicators - 1 set. c) Digital Voltmeter, Ammeter-1 set d) 3 phase 100 Amps aluminium busbar OUTGOING 1. 63 amps10KA TP MCCB - 4 Nos, 2. 32 amps tp mcb -2 nos, 3. 16 amps tp mcb -4 nos (Make: L&T/ schneider etc)
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.42 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.66 MB
Tendernotice_2.pdf
PDF • 7.69 MB
BOQ_28039.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .