Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹16.0 L+₹3.1 L (24.3%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹16.9 L+₹4.0 L (31.3%)Rejected-Finance G 86 DATA RAM SECTOR 18 ROHINI NEW DELHI DELHI 110085 | NORTH WEST DELHI | DELHI | 110085 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹17.9 L+₹5.1 L (39.3%)Rejected-Finance H 13 GEETANJALI PARK WEST SAGARPUR NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹18.3 L+₹5.4 L (42.3%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
₹33 L
EMD Value
₹66,000
Closing Date
3 Sept 2024, 6:00 pmClosed
GE NORTH DELHI CANTT 10
GE NORTH DELHI CANTT 10
REPAIR/MAINT OF EXTERNAL WATER SUPPLY SERVICE INCLUDING REPAIR REPLACEMENT OF UNSV PIPELINE VALVE VARIOUS WATER PUMP SET CLEANING OF SUMP AND OTHER CONNECTED EM WORKS AND REPAIR/MAINT OF EXTERNAL ELECTRIC SUPPLY SYSTEM INCL STREET LIGHT SECURITY LIGH
2024_MES_662730_1
GE/NORTH-42/2024-25
Open Tender
Civil Works
Item Rate
270 days
GE NORTH DELHI CANTT 10
As per NIT
8 documents required · 8 mandatory
₹500
Yes
GE NORTH DELHI CANTT 10
₹66,000
Yes
3 Dec 2024
28 Jun 2024
5 Sept 2024
28 Jun 2024
3 Sept 2024
13 Jul 2024
Amount
M&L for servicing of DG set capacity 10 KVA, 3 phase, 415 Volt, 50 Hz including carrying out maintenance and check alongwith following repairs including replacement of worn out parts :- (a) Replacement of lubricating oil (b) Replacement of Engine Oil filter cartridge with New one. (c) Cleaning /Descaling /Callibration of Deisel fuel tank and writing date of cleaning complete (d) Renew fuel filter cartridge with New one. (e) Check tightness of all nuts and bolts. (f) Check adjustment of V belt for driving engine water pump and alternator. (g) Assembling complete old serviceable parts and replacement of old unserviceable parts by new one as per direction. (h) Servicing of radiator (j) Cleaning of air cleaner filter and renew after period of hrs run as specified by manufacture. (k) Checking complete exhaust system including examining puncture in the mufler and redoing the complete insulation for adequate noise and pollution reduction complete (m) Testing of DG set after repair & servicing for smooth running of DG Set as per Manufacturers Instructions as directed . Note:- Any minor parts as required at site shall be supplied by the contractor. Cost for the same shall be deemed to be included in the unit rate quoted against this item.
S&F copper stranded cable PVC insulated three core PVC insulated for motor to starter of following sizes for various capacities of motors.
M&L for disconnection electrical and water connection of the centrifugal pump and motor 10 HP with base plate and transported to work shop opening carefully and replacement of bushes, gland packing, ball bearing, rubber gasket nut and bolt fixing the require new parts (parts such as shaft, impellor, coupling & bearing shall be supplied under relevant item of schedule) and complete re-fixing its in original position and making out all electrical and water connection and testing complete all as specified and directed. Note :- Rate includes transportation of motor from the place of installation for repairing and reinstalling the same on existing foundation, testing & commisioning complete.
Supply only shaft suitable for centrifugal pumps for 10 HP
Supply only GM impellor suitable for centrifugal pumps for 10 HP
Supply only MS coupling suitable for centrifugal pumps for 10 HP
Supply only bearing suitable for centrifugal pumps for 10 HP
S&F in replacement of connection pieces suitable for 10 HP pump
S&F in replacement of CI upper & lower housing for 10 HP
S&F in replacement of CI motor base for 10 HP
S&F in replacement of revolving disc for capacity10 HP
S&F in replacement of rotor guard for 10 HP
S&F in replacement of SS rotor sleeves for 10 HP
S&F in replacement of sealing ring for 10 HP
M&L for rewinding of electrical motor with super enameled copper winding wire of suitable size not less than original after cutting and taking out old winding complete with all insulation material such as colton top varnish etc of centrifugal pump set motor 10 HP complete
M&L for disconnection electrical and water connection of the induction motor with base plate and transported to work shop opening carefully and replacement of bushes, gland packing, ball bearing, rubber gasket nut and bolt including two coat of synthetic enameled paint over a coat of red oxide primer fixing the require new parts (parts such as shaft impeller and coupling bearing shall be supplied under relevant item of schedule) and complete re-fixing its in original position and making out all electrical and water connection and testing complete for the following size/ capacity of motors Note :- Rate includes transportation of motor from the place of installation for repairing and re-installing the same on existing foundation, testing & commisioning complete.
Supply only shaft suitable for induction motor pumps for the following sizes :-
Supply only bearing suitable for induction motor pumps for the following sizes :-
M&L for rewinding of electrical motor with super enameled copper winding wire of suitable size not less than original after cutting and taking out old winding with all insulation material such as colton top varnish etc of centrifugal pump set motor complete all as specified and directed for the following sizes :-
S&F in replacement of connection pieces suitable for 5 HP pump
S&F in replacement of CI upper & lower housing for 5 HP
S&F in replacement of CI motor base for 5 HP
S&F in replacement of rotor guard for 5 HP
S&F in replacement of SS rotar sleeves for 5 HP
S&F in replacement of sealing ring dor 5 HP
S&F fully automatic star delta starter appx full load with necessary relay and air break contactor complete with incoming and outgoing connection complete including taking down existing complete all as directed of size/rating MN 16F of make L&T at load of 9-15 Amps.
Excavation in trenches not exceeding 1.5m depth width and not exceeding 1.5m depth for laying pipes in loose/soft soil all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all as specified and directed.
Removal of surplus soil obtained from excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point all as specified and directed.
Supply, laying, jointing & testing of GI Pipe, medium grade, including all fittings in old/new position, laid in trenches/ wall including taking down the old/unsv pipe line complete all as specified & directed of following sizes :-
80mm dia
50mm dia
40mm dia
25mm dia
20mm dia
15mm dia (Note : Excavation and earth work shall be measured and paid separately under respective items of schedule)
S&F in repairs gun metal, globe or gate valve, screwed down high pressure with iron wheel head, screwed both ends complete for the following sizes of pipes :-
50mm dia
40mm dia
25mm dia
20mm dia
15mm dia
Supply, laying, jointing and testing of cast iron pipe with spigot & socketed end, centrifugally cast, Class LA push on joint laid in trenches in old/ new route as required at site including taking down the old/unserviceable pipe line complete all as specified & directed of following sizes:-
100mm dia
150mm dia [Note for item No.6 :- Contractor will make his own all necessary arrangement for execution / laying of pipe line work including liasion with civil / local authority at civil area / road, as & where applicable/ required]
M&L for run lead joint in spigot and socketted pipe of size 80mm including spun yarn complete all as specified and directed for following sizes of pipes :-
100mm dia
150mm dia
M&L for cast iron bends (any type, radius and angle) tapers any type (straight, bend, increasing decreasing or double socket etc) tee piees, single branch, 'Y' junction, double branch cross (all sockets or socket & spigot) collars, caps and plugs for spigot socketed pipes upto 150mm bore complete.
M&L for cast iron sluice valve of pressure class PN-1.6 type flanged and drilled at both ends, conforming to ISI mark and having gun metal spindle and rings including wheel for operating all as specified including two numbers flanged socket and jointing materials such as bolts, nuts, washers, rubbers/ fibre board gasket including taking down old unserviceable valve from pipe line of both ends complete of following sizes:-
100mm dia
80mm dia
Supply and fixing of non return valve of size 80mm dia, class PN-1.6, cast iron body, single door, both ends flanged type including all necessary fittings ie rubber gasket, nut & bolts, washers complete all as specified and directed.
M&L for bailing out the water from the semi underground/UG sump capacity upto 10,000 GLNS with out causing any interruption to regular water supply system and cleaning the same walls, roof and floor thoroughly by using wire brush/scrapper for removal of deposited scales/sludge/silt etc and removing the materials out of site cleaning thoroughly with water and bleaching powder and then by chlorine solution for complete anti bacterial disinfections with applying one coat of white wash inner and outer side including writing date of cleaning on the black board with white paint all as specified and directed Note:- The quoted rate against this item is deemed to be included all T&Ps and safety equipments required at site.
M&L for bailing out the water from the semi underground/UG sump capacity 20,000 GLNS with out causing any interruption to regular water supply system and cleaning the same walls, roof and floor thoroughly by using wire brush/scrapper for removal of deposited scales/sludge/silt etc and removing the materials out of site cleaning thoroughly with water and bleaching powder and then by chlorine solution for complete anti bacterial disinfections with applying one coat of white wash inner and outer side including writing date of cleaning on the black board with white paint all as specified and directed Note:- The quoted rate against this item is deemed to be included all T&Ps and safety equipments required at site.
M&L for PVC ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball complete assembly screwed for iron pipe and fixed and taking out unserviceable complete for the following sizes:-
S&F MS chequered plate of 6mm thick including provision of lifting handle for each plate on existing trenches/ manhole covers for semi under ground sumps according to site condition complete all as directed
M&L for construction of brick masonary valve pit chamber of size 1050mm x 1050mm x 1050mm (internal dimension) including necessary excavation and earthwork, PCCin foundation, brick work,12mm thick rendering in cement mortar 1:4 on internal surface of valve pit and mild steel sheet cover 3mm thick and mild steel angle iorn frame size 40 x 40 x 5mm around of valve pit, locking arrangement with pad lock of size 50mm brass, 6 leavers and key (Make : Godrej) complete including two coat of synthetic enamel over a coat red oxide primer on steel surface with preparation of surface and including dismantling of existing valve pit complete all as specified & directed.
All as per the description of srl item No 41 above item but size 900mm x 900mm x 900mm
M&L for spray painting of complete water pumpset of any type up to 10 HP capacity with two coats of synthetic enameled paint of specified colour after preparation of surface complete
M&L for painting of water supply pipes net works consisting of valves of any type and size at various pump houses inlcuding duly scrapping thoroughly the existing corroded paint / dirt/ dust / rust and preparing the surface and applying two coats of synthetic enamel paint over a coat of red oxide primer as per the colour code and marking the water flow directions on pipe lines as directed.
80mm bore
100mm bore
Supply only bleaching powder stable of 33% chlorine all as specified
M&L for earthing with Galvanised Steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using GI strip of size 25 x 4mm as earthing lead (upto the body of the equipment) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 40mm dia GI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel , wire mesh, pit cover and PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded crushed stone aggregate, including excavation and earth work in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 3 of SSR 2009 (Part-I) complete . Note-Testing of eathing after completion. the permissible resistence is obtained without any extra cost.
Supply only gland packing with wire rope 1/4 " 1/2"
Supply only rubber insertion sheet 4mm thick
S&F 3 pole power contactor ML-1.5 for starter including taking down old one complete
S&F 3 pole power contactor MNX 9 having 1 NO of rating 9-25 Amps complete.
S&F single phase preventor for 3 phase motors fixed for star delta starters complete.
S&F electronic timers type ST 100, 415 V for 3-30 secs complete.
S&F volt meter (0-500 volt) square/round digital type including taking down old one complete
S&F Amp meter (0-100) square/round digital type including taking down old one complete
M&L for preparation of old painted steel or iron surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coat of synthetic enameled paint of approved shade complete
S&F MCCB 4 Pole, 415 volt, 16 -36 KA of following capacity on existing panel including removing old one complete
160 amps, 36 KA, adjustible type
100 Amps, 16 KA, fixed type
63 Amps, 16 KA, fixed type
S&F in repairs battery brass terminal complete
Chemical, Boilogical, Potability Testing of water sample at Govt recognised/approved institute/Lab for potability and chemical analysis complete all as specified & directed.
Supply only Calcium Hypo Chlorite 65% to 70% granules as specified
S&F in replacement of water pressure gauge with black steel case, copper alloy wetted parts, snap-in- acrylic window with white plastic dial and plastic pointer having 0-21 kg/cm2 pressure range complete all as specified & directed
Supply only chlorination testing kit including solution, glass vessels tubular type etc complete all as specified and directed
M&L for total hardness test (5-1000 mg/L) kit with coloured sample complete with all testing fitment and OT solution in rexine finish box.
M&L for PCC 1:4:8 type D-2, using 40mm graded crushed stone aggregate 40mm graded, with and including demolishing the existing damaged foundation, complete all as directed.
S&F in repairs fully reflective sign board made of 18mm gauge stainless steel sheet frame of size 1200mm x 900mm sorrounded by 25mm stainless steel square pipe all around, applying two coats of synthetic enemal paint (blue colour) over a coat of red oxide including writing letters of height not exc 30 cm each (approx letters exc 30 and not exc 60 in numbers of any kind like block, roman, italic, indian, stop, commas, short line, dashes, hypens, brackets etc as directed by Engr-in Charge) with using retro reflective tape using HIP grade one, entire frame welded to post of 3.0 m long MS pipe of 50mm bore light grade( 2.60 Mtr above ground level and 0.40m below ground level), embeded on ground with PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate including necessary earth work of 30cm x 30cm x 40cm post holes complete all as specified and as directed
M & L in replacement of ladder for OHT/UG sump with sqaure bar, angle iron, channel, flat iron and etc welding, drilling, cutting with one primer coat, one under coat and one finishing coat of paint complete all as specified and as directed
M&L for painting of steel tubular poles 9 mtr to 11 mtr length with applying two coats of aluminium paint including cross arms and clamps except embedded portion of pole in ground and concrete after removing old painted surfaces by scraping of poles complete and two coat for making colour band/strip 30cm with synthetic enamel paint of approved/yellow & black colour up to 1.2 mtr from coping level including numbering of poles complete all as directed
M&L for painting of RCC poles 8.5 mtr to 11 mtr long with two coat of cement based paint and two coats of synthetic enamelled paint in yellow & black stip 30cm up to 1.5 mtr above the ground level including preparation of surfaces complete and painting of connected cross arms, clamps with aluminium paint all as specified and directed.
M&L for spray painting of old/existing LT panel/feeder piller box any size/type with powder coated paint withsmoke grey paint in outer/inner side of complete panel after cleaning and preparing surface complete all as specified & directed
M&L for repair/overhauling of old LT panel board of any size/type including cleaning with compressed air, tightening of all electric connections to bus bar & switchgears, re-fixing of door (front & backside) with proper fixing & locking arrangement, replacement of wornout lugs, nut, bolts, proper connection to main earth lead, glands to be provided/replaced as required at cable entries, fixing of door front & back side with proper locking arrangement, repair to PCC foundation as required at site and spray painting with powder coated paint with smoke grey paint in outer/inner side of panel after cleaning andpreparing surface including sign writing complete all as specified and directed
Dismantling & taking out HT/LT burnt cable ends of any size from transformer/LT panel/LT feeder pillar box/trenches any type/size, for repair/making suitable for reconnection to cable, providing lugs to burnt end of cables, preparing fresh terminals and reconnection, fixing the removed portion of cable with transformer/ in trenches/ along pole/ panel/ feeder pillar box, including excavation of loop & refilling complete using old bricks and sand returning filling the excavated soil complete all as specified and directed
Dismantling & taking out defective LT PVC/XLPE cable from trenches including excavation and earth work, cutting and removing defective parts and supply and fixing straight through joint heat shrink kit complete including jointing material and making connection of LT cables for the following sizes :-
25 sqmm 3.5 core to 50 sqmm, 3.5 core
70 sqmm 3.5 core to 95 sqmm, 3.5 core
120 sqmm 3.5 core to 240 sqmm 3.5 core
Sub class ‘B bricks, old size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning, with width equal to the length of the brick, complete all as specified and as directed
Sand cushioning to under ground cable with a layer of sand 8 cm before laying the cable and 15cm after laying the cable (10 cm punned thickness above the top of the upper most cable, total 18 cm), complete all as specified and directed.
M&L for boring/ making hole under road by drilling machine or hand drill without damaging of road for laying under ground cable for size 40/50/80mm bore of GI pipe complete all as specified & directed
S&F in replacement GI tubing light grade with all necessary fittings laid in trenches/under road crossing/fixed on pole including suitable mild steel flat iron clamps of required size complete for following sizes :-
40mm bore
50mm bore
80mm bore
Cutting/pruning of tree branches along/around over head line at places within a radius of 2 mtr from fasted conductor and removing from site complete all as directed
Servicing & overhauling of Air Circuit Breaker (ACB) of any capacity by taking out from existing LT panel, cleaning all parts internally and externally, checking of the proper tension of the springs mechanical mechanism, tightening of connection of moving, fixing contact, floating contacts, servicing of motor & charging system including replacement of faulty parts/spares and re-fixing it on its original position and testing complete all as directed
Supply and laying in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of following size. Note :- Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid seperately.
10 Sqmm 2 core
16 Sqmm 4 core
35 Sqmm 4 core
50 sqmm 3.5 core
70 sqmm 3.5 core
95 sqmm 3.5 core
120 sqmm 3.5 core
185 sqmm 3.5 core
240 sqmm 3.5 core
300 sqmm 3.5 core
S&F in repairs of 1100 volt grade, heavy duty cable PVC insulated aluminium stranded conductor, size 10 sqmm twin core flat or circular, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended complete all as directed
Checking all incoming & outgoing connections and Mechanism, cleaning, servicing, overhauling, testing it for proper tripping system complete of 11 KV VCB of of Make Crompton Greaves, installed at sub-station bldg, Inspecting, servicing and testing all the connections of control wiring availability of proper DC supply and AC supply, cleaning of contacts, & terminals, using the blower for dusting, servicing of gears, including replacement of faulty control fuses, faulty wiring & faulty indication lamp, checking & closing of tripping system, taking out relay (over current relay and earth fault relay) from the 11 KV VCB and calibrating the relay and proper setting of relay and refixing back in existing position & testing for proper tripping/functioning system complete all as specified & directed Note : Necessary certificate for calibration of relay with setting detail shall be submitted by the contractor
Disconnection of all electric connection & taking out old/ defective/ unsv Current Transformer (CT) from 11 KV VCB panel and Supply, fixing, installation & testing of Current transformer, indoor, comprising of 3 Nos single phase resin cast CTs of 100-50/5+5 amps ratio, Class 5P-10 with suitable VA burden and accuracy suitable for protection & metering including making suitable arrangement for fixing in existing VCB panel and connection including disconnection & taking out old/faulty current transformers (CTs) from 11 KV VCB panel complete all as specified & directed
Disconnection of all electric connection and taking down defective/unsv 11 KV PT and Supply, fixing, installation & testing of Potential transformer (PT) 3 phase, dry and draw out type 11 KV/110 Volt, with suitable VA burden per phase, accuracy class 1.0 complete with HT & LT HRC fuses for primary & secondary in VCB complete all as specified & directed
S&F in repairs heater, 230 Volt, as per existing wattage suitable for 11 KV HT VCB panel including electric connection complete all as specified & directed (Make - As per sample) Note for item No. 17 to 21 :- (i) All the instruments and T&P required for the above jobs shall be arranged by the contractor at site and cost of the deemed to be included in the above rates. (ii) The all above checking, inspection, installation & testing work shall be performed by HT expert/engineer.
M&L for on line Dehydration of HV/EHV grade transformer oil including filteration using automatic centrifuging machine minimum three cycles to achieve dielectric strength 50 to 60 KV breaking capacity by absorbing and abolishing all sludge particles as per BS-66-1963 including topping up with new transformer oil as required complete all as directed Note- (i) Centrifuging Machine with all T&P & testing machine of oil required for dehydration shall be arranged by the contractor. (ii) Oil required for topping up the transformer will be measured & paid separately
M&L in replacement of silica gel (Blue colour) in breather of transformer after cleaning of breather complete all as directed.
M&L in replacement of breather of transformer of any make/capacity upto 400 KVA with exising size complete all as directed
Supply & filling new transformer oil of having dielectric strenght 60 KV to top up level complete all as specified and directed
S&F in repairs LT Porcelain bushing with brass stud screwed with brass nuts, bolts and cork washer for transformer of capacity upto 400 KVA complete
S&F in repairs HT 11 KV porcelain bushing with brass stud screwed with brass nuts, bolts and cork washer for transformer of capacity upto 400 KVA complete
M&L (in repair) cable jointing kit for 11 KV cable for end termination heat shrink type joint with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of following size:-
Size 50 sqmm to 95 sqmm, Indoor type
Size 50 sqmm to 95 sqmm, outdoor type
M&L (in repair) cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable complete all as specified & directed of size size 50 sqmm to 95 sqmm
Supply & laying in trenches/through pipes/ducts or on poles XLPE armoured cable of following sizes with aluminum conductor, 11 KV `E’ complete all as specified & directed of follwing sizes Note :-Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid seperately
70 Sqmm 3 core
120 Sqmm 3 core
S&F hand charging handle rod suitable for existing 11 KV VCB of make Crompton Greaves complete all as specofied & directed
Checking & locating of fault in underground HT/LT cable of any size by cable fault locator machine complete all as directed
Taking out and repairing/overhauling of 11 KV air break gang operated switch tripple pole, mechanically operated mounted on insulators and steel frame installed vertically / horizontally, repairing defective copper strap, knife rod, movable post, insulator 200 amps capcity, ON/OFF handle, replacement of broken/worn-out components, oiling and greasing of mechanical moving parts, smoothing and polishing of electric contacts with providing conducting jelly of contacts refixed the same after repair complete all as directed
Supply, installation, testing & commissioning (in replacement) of Gang operated air break switch with drop out fuse unit complete with 12 insulator set, HT 11 KV triple pole, 200 amps current rating complete with drop out fibre glass tube fuse, mechanically operated mechanism from ground level consisting of operating rod of 25mm bore medium grade GI pipe of suitable length with locking arrengment, flat iron clamp 50mm x 6mm including MS channel of suitable size and length for fixing GOD including bolts, nuts and washers including jumper connection with copper flexible designed jumper complete all as specified and directed
M&L for repair/ overhauling of existing APFC panel of 80 KVAR rating including cleaning with compressed air, tightening of all electric connections, replacement of wornout/unserviceable parts such as automatic power factor controller relays, capacitors, contactors, CTs, cable of suitable capacity/rating with supply & replacement of lugs, nut, bolts, internal wiring with suitable size of PVC copper conductor wire, lugs/ thimbles of required size, including any work not included above but considered necessary for efficient performance of APFC panel and testing on completion complete all as specified & directed. Note :- Spare parts such as capacitors, relay, MCBs, contactor & indiacator lamps will be measured and paid separately
Supply& fixing capacitor metalized poly propylene heavy duty (MPP-H) for 3 phase 440 volts & 50 Hz system for permissible non- linear load 15% of 10 KVAR capacity
S&F (in replacement) lightning arrester, metal oxide type (gap less) for out door use complete with all fittings and fixing arrangements, transmission class, discharge capacity 65 kilo amps, suitable for 11000 volts including brackets, clamps, nuts, bolts, washers and connecting to earth wire 4mm dia GI with manufacturers test certificate complete all as specified & directed
M&L in replacement of danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with M.S clamps, bolts and nuts of approved size for HT/LT 20 x 15 cm size complete all as directed
S&F (in replacement) following items in the existing panel / location and connection with using aluminum lugs including making necessary alteration in panel/door as required for proper fixing & connection complete all as specified and directed Note:- MCCB should be properly fited in existing compartment and operating handle of MCCB should be proper in opening existing cover/door of compartment of LT panel board
MCCB 3 pole 63 amps, 16 KA breaking capacity, 415 Volt, fixed type
MCCB 4 pole 63 amps, 16 KA breaking capacity, 415 Volt, fixed type
MCCB 4 Pole 100 amps, 16 KA breaking capacity, 415 Volt
MCCB 4 Pole 125 amps, 16 KA breaking capacity, 415 Volt
MCCB 4 Pole 200 amps, 25 KA breaking capacity, 415 Volt
MCCB 4 Pole 250 amps, 25 KA breaking capacity, 415 Volt
MCCB 4 Pole 350 amps, 35 KA breaking capacity, 415 Volt
Volt meter (0 to 500 volts) digital type, three phase of size 96mm x 96mm
Amp meter (0 to 500 amps) digital type, three phase of size 96mm x 96mm with suitable CTs
Indicator lamp, LED type
S&F steel tubular electric pole, swaged type type 410 SP-31 (9 metre long) complete with CI base plate,finial taper plug bolts, nuts & screws all as specified including the following:-
Removal of surplus soil obtained from excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L for Providing PCC 1:4:8, type D2 (using 40mm graded crushed stone aggregate) in foundation 600mm x 600mm x 1500mm (planting depth) for concrete encasing the pole upto GL
M&L for Providing PCC 1:3:6, type C2 (using 40mm graded crushed stone aggregate) for plinth block /Collar above GL, 300mm high and 450mm dia
M&L for Providing PCC 1:2:4, type C2 (using 40mm graded crushed stone aggregate) for plinth block /Collar above GL, 300mm high and 450mm dia
M&L for painting of pole externally with one coats of black bituminous paint (upto planting depth) and above plinth block/ concrete collar with two coats of aluminium paint over a coat of red oxide primer including preparation of surfaces including painting of 30 cm wide black bands/strip 3 Nos with synthetic enamel paint in alternate layers upto the height of 1.5 Mtr above coping level complete all as directed
Dismantling and taking out userviceable / damaged PCC pole any size/type complete
S&F (in replacement) bracket for street light made out of 40mm bore GI pipe medium grade not less than 1.2 mtr length bent to shape fixed on pole/wall with and including 50x6mm FI clamps - 02 Nos with nut bolts, washers including painting of clamps with two coats of synthetic enamel paint over a coat of red oxide primer complete
M&L in repair for loop junction box, outdoor type, size 30cmx20cmX15cm, made out of engineering plastic one piece moulding type, bus bar rating 63 amps 4 strips aluminium with bus bar mounting colour R, Y, B, N on DMC unbreakable insulator with cable entry main supply from bottom side and pole light connection from back side, simens grey colout, shock proof, rust proof, fire retardant, having front opening and locking arrangement with MCB SP 10 amps - 01 No, box duly fixed on the pole with flat iron clamp of size 25 mmX3mm with nuts & bolts complete all as specified and directed Note : Cost of incoming & outgoing cable lugs & glands of suitable size deemed to be included in the quoted rate against this item.
M&L (in replacement) for LED street/security light fittings 45 watt, made up of of pressure die cast aluminium housing with toughned glass and individual high power LEDs with secondary optics, IP 66 protection, to be mounted on existing/ new GI bracket and connecting the street light fitting using 1.5 Sqmm PVC insulated copper cable complete all as directed. Note - New GI bracket with clamp shall be measured & paid seperately
All as per the description of srl item No 108 above but LED light fitting 60 watt
All as per the description of srl item No 108 above but LED light fitting 90 watt
M&L for LED Flood Light luminaire, energy saving & enviornmental friendly, long life diecast aluminium, IP65, with high power LED as light source including necessary fixing arrangement with clamps of suitable size and connection using 1.5 Sqmm PVC insulated copper cable complete all as directed for following wattage :-
S&F (in replacement) LED Post top lantern luminaire 70 Watt, 5700 K, energy saving, environmental friendly, long life aesthetically designes with symmetrical light distribution, spun aluminium landscape luminaire with high power LED as light source, clear acrylic cover, IP-65 including connection using 1.5 Sqmm PVC insulated copper cable complete complete all as directed
Repair of earth pit including required exacavation, earth work and PCC work to make good damaged/disturbed surfaces of earth pit chamber & making new pit cover of RCC 1:2:4 type B-1 using 20mm graded stone aggregate reinforced and lifting handle on RCC cover with 8mm MS bars at 150mm centre to centre both ways including supply & fixing of wire mesh and funnel including re-connection of earth wire/strip with panel/transformer using GI nut, bolts & washer complete all as specified & directed
All as per above item srl no.46 but with GI strip 32 x 6mm as earthing lead (earth strip will be protected by using 50mm bore GI pipe 'light grade')
S&F in repairs LED Post top lantern luminaire with die cast aluminium spigot, lid cover and clear acrylic cover 40 watt, 5700 K with IP-65 protection including connection complete.
M&L for PCC 1:4:8 type D-2, using stone aggregate 40mm graded, with and including demolishing the existing dameged foundation, including necessary form work where required and fair finish to the exposed surfaces, complete all as directed.
M&L for rewinding of transformer 100 kVA to 500 kVA complete using appropriate size of copper wound wire (HT/LT coils), including opening all electrical connection,taking out of Old/burnt coil ,transportation to civil workshop and return back with including labour cost and testing complete all as secified ad directed.
M/s Prakash Enterprises (BID ID -3063409)
NEETU TRADERS (INDIA) (BID ID -3068647)
J.P. Enterprises (BID ID -3066397)
MK Enterprises (BID ID -3068494)
MOHIT ENTERPRISES (BID ID -3068287)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .