| 1.00 | Labour for servicing / over hauling of spilt type AC/window AC/Casetter AC /Tower AC indoor/outdoor of capacity 1/1.5/2.0/2.5 TR of any make and type including following item of works:
(a) High Preesure water Jet cleaning of complete unit including cooling coil condenser, Fan (Outdoor unit), blower etc.
(b) Checking of Electrical wiring and carrying out necessary repairs/replacement along with lugs, clamps, soldering etc.
(c) Checking of refrigerant piping and carrying out necessary repairs to copper tubing
(d) Checking of all components/accessories for their serviceability .
(e) Greasing and oiling of fan motor
Note:
Note:- Every machine shall be serviced Twice in contract period. All spares parts required shall be measured and paid for separately . | 244 | Each Job | 504 ₹1.2 L | 325 ₹79,300 | 2,750 ₹6.7 L |
| 2.00 | Attending uregent complaint by qualified technician for immediate site inspection, fault finding, and diagnostic testing of a Split AC unit (1.5TR - 2.5TR) at diffrence places under area of AGE E/M . Including testing of electrical circuits, compressor health, and PCB functionality, Nitrogen pressure testing to identify micro-leaks in the evaporator coil, condenser coil, or flare nuts. Includes soap bubble test and vacuuming of the system using a vacuum pump complete all as specified and directed
On call services shall include atteding to any complaint any time of the contract period on receipt of verbal/written complaint from user/JEE/M/Engr-in-Charge.The contractor has to rectify the defects / repair and make the Split AC functional within 24 hours from the time In case the Split AC is not made functional for whatsoever reason within the specified time limit, an amount of Rs 500/- per such defective Split AC per day will be recovered from the amount due to him through RAR / Final Bill. The contractor shall carry out repair / maint work simultaneously for AICTS and connected area | 60 | Each Job | 168 ₹10,080 | 200 ₹12,000 | 3,000 ₹1.8 L |
| 3.00 | M & L for for replacement of in repair complete Wiring kit of SPLIT AC and window AC of 1.5 and 2.5 sqmm copper flexible cable complete all as specified and directed | 20 | Each Job | 504 ₹10,080 | 180 ₹3,600 | 100 ₹2,000 |
| 4.00 | S&F in replacement of electronic circuit plate (PCB) including necessary repairs to electronic circuit for remote operation suitable for 1.5 / 2.0 ton split type AC for any type complete all as specified and as directed | 50 | Each Job | 1,008 ₹50,400 | 1,250 ₹62,500 | 2,000 ₹1 L |
| 5.00 | Taking down unserviceable/damage wall mounted cooling coil unit of split type AC complete by means of disconnecting electrical connection and suction and discharge pipe line and S&F new cooling coil indoor unit of 1.5 ton capacity of existing dismantled model or equivalent approved by Engineer-in-Charge including remote control, proper fixing on wall, connect to electrical system and connect to suction and discharge pipe line, drain water pipe line as directed and testing and commissioning complete for satisfactory performance of unit after gas charging of following capacity | 4 | Each Job | 9,520 ₹38,080 | 11,500 ₹46,000 | 15,000 ₹60,000 |
| 6.00 | All as per item No-5 above but 2 ton capacity | 4 | Each | 10,080 ₹40,320 | 12,500 ₹50,000 | 15,000 ₹60,000 |
| 7.00 | Taking down unserviceable/damaged/rusted condensor unit of split type AC complete by means of disconnecting electrical connection and suction and discharge pipe line and S&F new condensor outdoor unit consisting of body, motor, condensor & blade suitable for 1.5 ton existing dismantled model or equivalent approved by Engineer-in-Charge and connect to suction and discharge pipe line to compressor after refixing compressor of existing unit as directed and testing and commissioning complete for satisfactory performance of unit after gas charging of following capacity | 4 | Each | 11,200 ₹44,800 | 13,500 ₹54,000 | 15,000 ₹60,000 |
| 8.00 | All as per item No-7 above but 2 ton capacity | 4 | Each | 12,320 ₹49,280 | 14,500 ₹58,000 | 15,000 ₹60,000 |
| 9.00 | M&L for disconnecting electrical connection and dismantling/ taking out indoor and out door unit of split type air conditioning of any make and capacity from any place and installation, commissioning and testing to another location including transportation from existing bldg to another bldg including making good the disturbed surfaces complete all as specified and as directed by Engineer-in-Charge. | 25 | Each Job | 1,400 ₹35,000 | 2,900 ₹72,500 | 200 ₹5,000 |
| 10.00 | S&F in repair fan/blower motor for window double shaft single/double speed, single phase, 230 V , AC of 1/4HP, capacity as required complete, making suitable fixing arrangment for existing place (as per sample) including taking down old unsv complete all as specified and directed | 1 | Each | 2,712 ₹2,712 | 1,750 ₹1,750 | 250 ₹250 |
Updated dates
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
28 May 2026, 6:00 pmClosed
GE SOUTH PUNE
NO 1 GEN BHAGAT MARG PUNE 40
8829 PREVENTAVIE MAINT REPAIR REPLACEMENT OF SUMMER COOLING APPLIANCESAND INTERNAL EM ALLIED WORK AT CTC JCOS OR MD ACCN AND CONNECTED AREA UNDER AGE EM I OF GE SOUTH PUNE
2026_MES_762936_1
8829 GE SOUTH PUNE
Open Tender
Electrical and Maintenance Works
270 days
GE SOUTH PUNE
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE SOUTH PUNE
₹98,000
Yes
9 Jun 2026
30 Apr 2026
30 May 2026
30 Apr 2026
28 May 2026
15 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Labour for servicing / over hauling of spilt type AC/window AC/Casetter AC /Tower AC indoor/outdoor of capacity 1/1.5/2.0/2.5 TR of any make and type including following item of works:
(a) High Preesure water Jet cleaning of complete unit including cooling coil condenser, Fan (Outdoor unit), blower etc.
(b) Checking of Electrical wiring and carrying out necessary repairs/replacement along with lugs, clamps, soldering etc.
(c) Checking of refrigerant piping and carrying out necessary repairs to copper tubing
(d) Checking of all components/accessories for their serviceability .
(e) Greasing and oiling of fan motor
Note:
Note:- Every machine shall be serviced Twice in contract period. All spares parts required shall be measured and paid for separately . | 244 | Each Job | - | - |
Attending uregent complaint by qualified technician for immediate site inspection, fault finding, and diagnostic testing of a Split AC unit (1.5TR - 2.5TR) at diffrence places under area of AGE E/M . Including testing of electrical circuits, compressor health, and PCB functionality, Nitrogen pressure testing to identify micro-leaks in the evaporator coil, condenser coil, or flare nuts. Includes soap bubble test and vacuuming of the system using a vacuum pump complete all as specified and directed
On call services shall include atteding to any complaint any time of the contract period on receipt of verbal/written complaint from user/JEE/M/Engr-in-Charge.The contractor has to rectify the defects / repair and make the Split AC functional within 24 hours from the time In case the Split AC is not made functional for whatsoever reason within the specified time limit, an amount of Rs 500/- per such defective Split AC per day will be recovered from the amount due to him through RAR / Final Bill. The contractor shall carry out repair / maint work simultaneously for AICTS and connected area | 60 | Each Job | - | - | |
M & L for for replacement of in repair complete Wiring kit of SPLIT AC and window AC of 1.5 and 2.5 sqmm copper flexible cable complete all as specified and directed | 20 | Each Job | - | - | |
S&F in replacement of electronic circuit plate (PCB) including necessary repairs to electronic circuit for remote operation suitable for 1.5 / 2.0 ton split type AC for any type complete all as specified and as directed | 50 | Each Job | - | - | |
Taking down unserviceable/damage wall mounted cooling coil unit of split type AC complete by means of disconnecting electrical connection and suction and discharge pipe line and S&F new cooling coil indoor unit of 1.5 ton capacity of existing dismantled model or equivalent approved by Engineer-in-Charge including remote control, proper fixing on wall, connect to electrical system and connect to suction and discharge pipe line, drain water pipe line as directed and testing and commissioning complete for satisfactory performance of unit after gas charging of following capacity | 4 | Each Job | - | - | |
All as per item No-5 above but 2 ton capacity | 4 | Each | - | - | |
Taking down unserviceable/damaged/rusted condensor unit of split type AC complete by means of disconnecting electrical connection and suction and discharge pipe line and S&F new condensor outdoor unit consisting of body, motor, condensor & blade suitable for 1.5 ton existing dismantled model or equivalent approved by Engineer-in-Charge and connect to suction and discharge pipe line to compressor after refixing compressor of existing unit as directed and testing and commissioning complete for satisfactory performance of unit after gas charging of following capacity | 4 | Each | - | - | |
All as per item No-7 above but 2 ton capacity | 4 | Each | - | - | |
M&L for disconnecting electrical connection and dismantling/ taking out indoor and out door unit of split type air conditioning of any make and capacity from any place and installation, commissioning and testing to another location including transportation from existing bldg to another bldg including making good the disturbed surfaces complete all as specified and as directed by Engineer-in-Charge. | 25 | Each Job | - | - | |
S&F in repair fan/blower motor for window double shaft single/double speed, single phase, 230 V , AC of 1/4HP, capacity as required complete, making suitable fixing arrangment for existing place (as per sample) including taking down old unsv complete all as specified and directed | 1 | Each | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.66 MB
8829TD.pdf
Tender Documents • 1.10 MB
BOQ_854595.xls
BOQ • 2.16 MB
Download all tender documents and submit your bid