Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.0 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹6.5 L+₹3,040 (0.47%)Rejected-Finance 329 COD COLONY KOYLA NAGAR PO KIDWAI NAGAR KANPUR 208011 | KANPUR | KANPUR | UTTAR PRADESH | 208011 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹6.8 L+₹38,463 (5.96%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹6.9 L+₹40,190 (6.23%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹7.6 L+₹1.1 L (17.7%)Rejected-Finance 74 103 DHANKUTTI KANPUR 208001 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208001 | L5 | Rejected-Finance Being L5 |
Tender Value
₹12 L
EMD Value
₹24,000
Closing Date
1 Dec 2021, 6:00 pmClosed
GE I R and D Kanpur
GE I R and D Kanpur DMSRDE Complex, GT Road Kanpur 208013
REPAIR/REPLACEMENT/MAINT OF INTERNAL WIRING AND OTHER CONNECTED ACCESSORIESETC IN DOMESTIC AREA (60SCIENTIST HOSTEL,WAR MEMORIAL COLONY,TRANSIT HOSTEL,MES KEY PERSONNEL QTRS) DGQA /DRDO POOL QTRS UNDER GE(I) R and D KANPUR.
2021_MES_485903_1
8256/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
War Memorial Colony GE I R and D Kanpur
As Per NIT
8 documents required · 8 mandatory
₹500
Yes
GE I R and D Kanpur
₹24,000
Yes
4 Mar 2022
2 Nov 2021
3 Dec 2021
3 Nov 2021
1 Dec 2021
17 Nov 2021
Amount
M & L for sub main wiring in replacement of worn out aluminium conductor wire with two run of FR PVC insulated unsheathed flexible copper conductor (Multistrands), single core of size 4.0 Sqmm, 1100 Volts grade and one run of 2.5 Sqmm FR PVC insulated unsheathed as earth (In Green Colour), flexible copper conductor (Multistrands) for continuous earthing conforming to IS 694 with latest amendments and including draw in PVC rigid conduit 25 mm dia , connecting incoming / outgoing electric connections by using required size copper lugs / thimbles and making good the disturbed surface to match with existing colour (distumber, Oil bound, Samosem etc ) complete in all respect all as specified and directed.
Note :- 1. Two run of single core cable with one run of contineous earth wire of copper conductor wire flexible (Multistrand) of FR PVC insulated shall be measured and paid as one unit length 2. PVC conduit pipe with fitting shall be measured and paid separately .
M & L for sub main wiring in replacement of worn out aluminium conductor wire with two run of FR PVC insulated unsheathed flexible copper conductor (Multistrands), single core of size 6.0 Sqmm, 1100 Volts grade and one run of 4.00 Sqmm FR PVC insulated unsheathed as earth (In Green Colour), flexible copper conductor (Multistrands) for continuous earthing conforming to IS 694 with latest amendments and drawing in PVC rigid conduit , connecting incoming / outgoing electric connections by using required size copper lugs / thimbles and making good the disturbed surface to match with existing complete in all respect all as specified and directed.
Note :- 1. Two run of single core cable with one run of contineous earth wire of copper conductor wire Flexible (Multistrand) of FR PVC insulated shall be measured and paid as one unit length. 2. PVC conduit pipe with fitting shall be measured and paid separately .
Supplied and fixing in replacement PVC conduit by Non Metallic Rigid PVC conduit, ISI Marked, conforming to IS 9537, medium grade of size 25 mm dia including all fittings like bends, elbow reducer, junction boxes, tee bell mouth all fixing accessories such as coupler lock, nuts, saddles pipe hooks etc complete including Cutting & Chasing required on brick wall not exceeding 10 CM girth for concealed conduit wiring and making good to disturbed surface with cement mortar 1:3 and distemper / colour wash etc to match with existing surfaces including facing / finishing complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.
M&L for drawing the wire in existing conduit steel/PVC complete with point wiring with FR PVC insulated, unsheathed stranded copper conductor of nominal area 1.5 Sqmm, 1100 volts grade, along with one single run of same size and type of copper wire as continuous earth wire to common earth dolly in and sunken terminal boxes pressed MS/GI steel terminal boxes not less than 1.20 mm thick for mounting switch, socket etc including 3 mm thick Hylam brand sunmica laminated sheet cover with brass screw and cup washers with all accessories and making good to disturbed surface with cement mortar ratio of 1:3 and matching surface with existing white/colour wash, oil bound or cement base paint etc to match with existing surface complete all as specified and directed and suitable for the following: -
i) One light point or one fan point controlled by one way, single pole switch
(ii) One 3 pin socket outlet, 6 Amp on “independent board” but below/side the switch board of the light point in same vertical plane.
(iii) One 3 pin socket out let, 6 amps on the "same board" with other switches
(iv) One 3 pin socket outlet, 6 Amp on “independent board”
(v) One bell / buzzer point controlled by one push button on “independent board”.
All as per item No. 5 here in above but drawing in existing conduit for point wiring using 2.5 Sqmm (Nominal area) FR PVC insulated unsheathed copper conductor 1100 volts for one 3/6 pin socket outlet ,suitable for 6/16 amps on “independent board”.with 1.5 sqmm with one single run copper wire as continuous earth wire to common earth dolly complete.
Attending the complaints lodged by the occupants/users of electrification nature & rectification of the fault as per the complaint lodged by the user onward OH line LT/HT lines in any time (day/Night) in respect of main fixture /breakdown for light/fan/bell/light or power socket and LT/HT OH line etc complete repairs to the extent by removing connections from the system removing faults in wires, battens, conduit, sunken boxes, junction boxes, main switches, MCBs/DBs utility light fitting, lamp holders AC ceiling/ Exhaust fans and other type of complaints to connected fixtures of the internal electrification including providing of petty stores such as wires of appropriate size and conductor matching to existing one upto the length of 1 mtr including insulation tape, screws , nuts as required to rectified the fault with regard to the complaint lodged and refixing of fittings, fixtures to their position as dismantled and respect of item if required to be paid under respective item as required complete all as directed at site to th entire satisfaction of Engr-in-Charge/users. Note for Srl No -01 :- (a) No light ,breakdown, repair/ replacement of switches, fan, regulator , replacing burnt/ damaged wiring , replacement of burnt MCBs and main switch , voltage fluctuation, current leakage, replacement of HT DOs/fuse, repair of street lights, repair of OH line, OH conductor and replacement of tube lights etc will be attended with in 8 Hrs as urgent nature. (b) Any LT breakdown complaints will be attended by skilled electricians/ Helpers as required at site without any delay & any time (day/Night).
(c ) The complaints will be attended by electricians & respective helpers in each day & night without any delay. (d) The complaint will be taken from complaint cell of war memorial colony. The rates are included for complaints for 60 scientist hostel, MES Key personnel qtrs, War memorial colony, Transit hostel, RCMA office and residential Accn and complaint cell of Raksha vihar colony. (e) All necessary tools & plants i.e. multimeter, tong tester, spanner set, wrench, screw driver set, combination plier, testing lamp set, drilling machine, bamboo ladder, blower/ vaccum cleaner, crimping tool, cutting and chasing tool, insulation megger , etc will have to kept by each tradesman engaged by contractor at his own cost. (f) Any accident/ mishappening occurred during the execution of work shall be responsibility of Contractor. (g) One MOBILE PHONE should also be provided by contractor to the each trademan engaged by him with incoming & out going facilities for normal and after working hours also so as to contact him in case of emergency during the entire period covered under the contract to keep liaison / communication with MES staff . (h) complaint register and complaint slip shall be providing by the contractor duly printed with CA No and firm and the cost is deemed to be included in unit rate (j ) Cost of material and labour for replacement of new items shall be measured and paid separately under relevant items of Sch A. Against supply only here-in-after .
Supply only switch piano flush button type, 6 Amp one way, 240 Volt, single pole , ISI marked conforming to IS 3854 style double colour series with cover plate complete all as specified and directed. Code No.7001& 7301of make Cona or equivalent of Anchor/SSK/Crabtree or as approved by GE (I).
Supply only Ding Dong sound door bell AC, 230 volts complete all as specified and directed. Code No. 3391/3421 of make - Cona or equivalent model in Anchor/SSK/Crabtree as approved by GE(I)
Supply only bell push switch piano flush button type, 6 Amp one way, 240 Volt, single pole , ISI marked conforming to IS 3854,style double colour series with cover plate complete all as specified and directed. Code No.7011 & 7301 of make Cona or equivalent of Anchor/SSK/Crabtree or as approved by GE (I).
Supply only socket out let, 2 in 1, 5 pin, 6 Amp, 240 Volt AC, flush type, style double colour series with cover plate complete all as specified and directed. Code No. 7021& 7306 of make Cona or equivalent of Anchor/SSK/Crabtree as approved by GE(I).
Supply only switch socket combination multipurpose 5 in 1, 6 pin, 6 and 16 Amp, 240 Volt AC, style duoble colour series" with cover plate complete all as specified and directed. Code No. 7096 & 7316 of make Cona or equivalent of Anchor/SSK/Crabtree as approved by GE(I).
Supply only FASHION batten/angle holder with colour ring. Code No. 2476/2471 of make Cona or equivalent of Anchor/SSK/Crabtree as approved by GE(I).
Supply only FASHION ceiling rose with colour ring. Code No. 2186 of make Cona or equivalent of Anchor/SSK/Crabtree as approved by GE(I).
Supply only medium step type fan regulator 80 Watt, 240 Volt AC, style double colour series "style medium step" ISI marked complete all as specified and directed. Code No.7066 & 7306 of make Cona or equivalent in Anchor/SSK/Crabtree as approved by GE (I).
Supply only FR PVC insulated, unsheathed, single core, flexible copper conductor wire suitable upto voltage grade 1100 Volt , ISI marked, conforming IS 694/1990 with latest ammendment in different colour of following sizes :- Make - Plaza/KEI/Polycab
(a) 0.75 Sq mm
(b) 1.5 Sq mm
(c ) 2.5 Sqmm
(d) 4.0 Sqmm
(e) 6.0 Sqmm
Supply only SPN Distribution Box, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 8 way, confirming to IS 13032 & 8623 complete all as specified and directed. Cat No. Indo Asian optipro/Schneider (Electric)/Legrand as approved by GE (I).
Supply only MCB SPN, 32 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed. Make -Indo Asian optipro /Schneider Electric/Hager /legrand as approved by GE (I).
Supply only MCB SPN, 63 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed. Make -Indo Asian optipro/Schneider Electric/Hager /legrand as approved by GE (I).
Supply only MCB SP, 06 to 32 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed. Make -Indo Asian optipro/ Schneider Electric/Hager as approved by GE (I).
Supply only MCB TPN, 63 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed. Make - INDOASIAN/Schneider Electric/Legrand/ABB as approved by GE (I).
Supply only Condensor of 2.5 MFD, 440 Volt AC , conforming to IS - 1709 for ceiling fans, Make - Epcos/ L&T/ Siemen/Universal
Supply only 1100 volts grade heavy duty cable PVC insulated aluminium conductor cable 6 Sq mm twin core flat or cercultor served with inner sheathing of PVC tape and over all PVC sheathed complete all as specified and directed .
Supply only 1100 volts grade havy duty PVC insulated copper conductor wire 23/076 three core with PVC sheathed cover complete .
Supply only self adhesive PVC electrical insulation tape, ISI Marked, conforming to IS 7809, Part - 3, Section -1 of size as under :- (i) Length - 8 Mtr (ii) Width - 18/19 mm (iii) Thickness - 0.125 mm Make - Steelgrip/Anchorgrip/Miracle or as approved by GE(I)
Supply only AC/Geyser box by sheet steel enclosure in single pole and neutral fitted with two pin and earth plug and socket complete with one single pole MCB, 240 volt, 20 Amps , 'C' series of suitable rating complete all as specified and directed . Make- Legrand/ Schneider Electric as approved by GE (I).
Supply only MCB 4 pole, 100 Amps 415 volt 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed. Make -Schneider Electric/ABB /legrand as approved by GE (I).
Supply only LED lamp retrofit 12 Watt, 230 volts,50 HZ,AC supply with base holder B22 white colour with polycarbonate body and aluminium heat sink complet all as specified and directed . Make Philips/Crompton/C&S.
Supply only LED light fitting trend wall mounted batten with extruded aluminum housing with intregated LEd driver complete along with LED tube aluminum extrusion 20 watt complete. Make: Philips cat part : BN108C LED 20S PSU NW WH/ Cat part of C & S: LTDC0122WLED/WD/Crompton
Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground (Earth pit not less than 2.25 metre below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanised earth strip 32 x 6.00 mm by means of bolts nuts check nuts and protection with 50 mm dia GI Medium grade pipe and washers of galvanised iron or steel, GI strip 7.5 mtr long and plate surrounded with salt charcoal dust etc and 20 mm bore GI light grade pipe for watering, excavation and earth wire including PCC pit in cement concrete 1:3:6 type CI and 40mm thick pit cover of RCC 1:2:4 type 30 reinforced width 8mm dia MS bar @ 150 C/C both ways, furnel wiremesh and testing after completion complete all as specified and directed.
Supply, fixing and testing in replacement of Old unserviceable/ worn out LED T8 Retrofit Tube light:Tara Series.LED T8 retrofit light 20 watt 240 volt,Light source SMD LED array having IP 6X protection complete, all as specified and directed including all accessories complete . Cat part no. of make C&S LT4F20WLEDT8/WD /Cat part no. of Crompton: LTT8-20 or equivalent model in Phillips.
42. S & F in replacement of MCCB with continuously adjustable electronic release ,4 Pole, 415 VAC, Current rating- 400 Amps, Breaking capacity ( Icu ) - 36 KA with thermal setting between 70% to 100% and Ics is equal to 100% of Icu as per the Table- 1, page 13 of IS 13947 (Part-2) /1989, having over current/load protection setting O/L (lr) : 0.7 - 1 In & Short Circuit setting S/C : 2 -10 lr with Rotary Controls/Handle, conforming to IS 13947-II / IEC 60947 - II complete all as specified and directed . Make Legrand / Schenider(Electric) /INDOASIAN
43. S&F in replacement of MCCB with continuously adjustable electronic release ,4 Pole, 415 VAC, Current rating- 250 Amps, Breaking capacity ( Icu ) - 25 KA with thermal setting between 70% to 100% and Ics is equal to 100% of Icu as per the Table- 1, page 13 of IS 13947 (Part-2) /1989, having over current/load protection setting O/L (lr) : 0.7 - 1 In & Short Circuit setting S/C : 2 -10 lr with Rotary Controls/Handle, conforming to IS 13947-II / IEC 60947 - II complete all as specified and directed . Make Legrand / Schenider(Electric) /L&T/INDOASIAN
44. S&F in replacement of MCCB with continuously adjustable electronic release ,4 Pole, 415 VAC, Current rating- 100 Amps, Breaking capacity ( Icu ) - 25 KA with thermal setting between 70% to 100% and Ics is equal to 100% of Icu as per the Table- 1, page 13 of IS 13947 (Part-2) /1989, having over current/load protection setting O/L (lr) : 0.7 - 1 In & Short Circuit setting S/C : 2 -10 lr with Rotary Controls/Handle, conforming to IS 13947-II / IEC 60947 - II complete all as specified and directed . Make Legrand / Schenider(Electric) /L&T/INDOASIAN
supply and fixing of MCCB 200 Amps 25 KA with fixed thermal magnetic release frame F2 optim 1.0 , 4pole all as specified and directed. Make -Schneider Electric/Legrand/L & T/INDOASIAN
DEO Traders
SAKSHAM SUPPLIERS BUILDERS
YS CONSTRUCTION
Himanshu Construction and Suppliers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .