Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹14.6 LAccepted-AOC 10TH FLOOR TOWER A3 FLAT NO 1001 MI RUSTLE COURT GOMTI NAGAR EXTENSION GOMTI NAGAR LUCKNOW UP 226010 | LUCKNOW | LUCKNOW | UP | 226010 | 1 | Accepted-AOC L-1 | |
| 2 | 2₹15.8 L+₹1.0 L (7.09%)Rejected-Finance 118 442 E 2 KAUSHALPURI KANPUR 208012 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208012 | 2 | Rejected-Finance Being other than L-1 | |
| 3 | 3₹15.8 L+₹1.1 L (7.24%)Rejected-Finance 143 ALLAHABADPUR GORAKHPUR | GORAKHPUR | GORAKHPUR | UTTAR PRADESH | 273001 | 3 | Rejected-Finance Being other than L-1 | |
| 4 | 4₹16.3 L+₹1.6 L (10.6%)Rejected-Finance | 4 | Rejected-Finance Being other than L-1 | |
| 5 | Rejected-Technical | - | Rejected-Technical Being as related firm M/s Bechan is banned in WLR |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
16 Apr 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE EAST LUCKNOW
GE EAST LUCKNOW
SPL REAPIR TO OVER HEAD LINE FROM POWER HOUSE BLDG TO GATE NO 08 EXCEPT NCC LINE AND OTHER SANCTIONED WORKS AT MIL STATION BARABANKI UNDER GE (EAST) LUCKNOW.(5th Call)
2021_MES_409763_5
GE/E/LKO/T-64 OF 2020-21
Open Tender
Miscellaneous Works
Item Rate
180 days
Barabanki
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
GE EAST LUCKNOW
₹30,000
Yes
22 May 2021
30 Mar 2021
17 Apr 2021
30 Mar 2021
16 Apr 2021
3 Apr 2021
60 days
Amount
M&L for point wiring with 1.5 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sq mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic ISI PVC conduit of 20 mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of sunk zinc coated pressed steel terminal box of 1.60 mm thick with 3 mm thick plastic laminated sheet top cover, brass screws, cup washers etc and making good to the disturbed surfaces to match the existing complete all as specified and directed for one light / fan point controlled by one, one way switch 06 Amp complete all as specified and directed.
Supply and fix switch piano flush type, 06 Amp, single pole, one way, 230 Volt complete all as specified & directed.
S&F for desert cooler, electric driven (single phase), steel body having nominal air flow capacity of 5000 Cum per hour (or nearest size) complete all as specified and directed.
S&F for mild steel framed work such as grills, gratings etc with ends of bar shoulder &/or riveted or forged into spikes: framed guard bars: barred iron doors: ladders: framed balusters: walk ways: railings: frame work of water tanks & similar work confirming to Fe 290 Gde E-165 complete all as specified and directed.
M&L for preparation of new steel surface of any description over 10 cm width or girth and apply two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Supply & laying XLPE insulated, armoured, heavy duty, underground electric cable with aluminium conductor, 1100 volts grade, cross section area 25 Sqmm, 4 core, complete, all as specified and directed. (Note :- Excavation & Earth work shall be measured and paid separately under the respective items.)
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5m deep for laying of pipe, cable etc and getting out in soft/loose, complete, all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc. 25 cm thick in soft/loose soil, complete, all as specified and directed.
Removing surplus excavated material to a distance exc 250 meter and not exc 500 meter and depositing where directed at level not exc 1.5m above the starting point, complete, all as specified and directed.
M&L Sand cushioning to U/G cable in layers of 23 cm thick (8 cm before laying the cable and 15 cm thick after laying the cable, punned thickness shall be measured) in trenches complete all as specified and directed. Note: - Only punned thickness shall be measured.
Supplying and laying un-reinforced precast concrete cable cover, class HVP, type 1 with peak, size 300mm x 180mm x 40mm for protection of cable complete all as specified and directed.
S&F PVC weather proof, hinged door, junction box with 30A Aluminium bus bar 04 Nos, 240V, Neutral link and 1No MCB SP of 06 Amps, alongwith necessary fixing arrangement such as clamps, nut, bolts, etc complete all as specified and directed.
Supplying and laying GI pipe, 40mm dia, Light grade for cable protection at road crossing etc including necessary road cutting and making good with PCC 1:2:4, Type B-1, using 20mm graded stone aggregate, 100mm thick or fixing on wall / poles of any type, secured with clamps complete all as specified and directed.
Boring of road for laying of pipe not exceeding 90 cm below groundlevel all complete as specified and as directed.
Supplying & laying Fly ash brick laid flat with width equal to the length of brick over cable protection complete all as specified and directed.
M&L Stay assembly comprising of 20 mm dia stay rod 2150 mm long, loop type insulator of size 90 mm x 140 mm, galvanised stay plate 6mm thick of size 300 mm x 300 mm, stay bow, stay clamps etc. complete all as specified and directed & shown in EP No. 1 of SSR Pt I. Note : Excavation, earth work and PCC shall be measured and paid seperately.
M&L for Galvanised stay strand 7/4 mm complete all as specified and directed.
M & L in replacement Earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6.0 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level connecting to the GI strip 32 x 6mm, by means nut bolt, nuts, check nuts and washer of the GI Earth wire protected by provision of GI light grade pipe 40 mm incl provision of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregated with 40 mm thick cover with RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg / Sqm) and frame of angle iron 25mm X 25 mm X 3mm with lugs 2 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, taste point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point complete all as specified and directed.
Supply in replacement of unserviceable PVC insulated sheathed cable with stranded copper conductor of size 1.5 sqmm 3 core from light fitting to junction box complete all as specified and directed.
Demolition mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) including cleaning washing down etc. complete all as specified and directed.
M & L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in padding to maintain slope complete all as specified and directed.
M & L for cleaning of all loose dirt and dust from roof surfaces and applying roof treatment as under :- (a) M & L for brushing neat cement slurry with 3 Kg of cement per Sqm complete all as specified and directed. (b) M & L for 10mm thick plastering in CM 1:4 using 100% course sand on roof including WPC @ 3% by weight of cement. (c) Applying a coat of bitumen primer @ 0.50 ltr/sqm on prepared and allow to dry. (d) Applying a coat of hot blown type bitumen grade 85/25 @ 1.20 Kg/Sqm over primer. (e) Supplying and laying 3mm Third layer of APP modified polymeric membrane thick (Min) polymeric water proofing membrane weight not less than 3 Kg/Sqm. (f) Applying a tack coat of hot blown type bitumen grade 85/25 @ 1.20 Kg per Sqm. (g) Applying two coat of bituminous aluminium paint 200 gram/Sqm (minimum).
S&F for 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls incl taking down the same complete all as specified and directed.
S&F for 110mm bore PVC (SWR) bends any radius complete all as specified and directed.
M & L for providing E-board `Everest` or equivalent make 600 x 600 mm and 12mm thick white prelaminated sett embosed reinforced designer as approved ceiling board/tiles at any height on anodized aluminium snap grid size 605x605mm of frame work for false ceiling complete all as specified and directed.
M&L for complete removal of existing treatment from old / new plastered surfaces of wall and applying two coats of oil bound distemper over a coat of 3mm thick wall care putty on walls, complete all as specified and directed.
Supreme Builders
Sanjai sales and services
M/S NATIONAL ELECTRIC WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .