Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.9 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹44.9 L+₹3.4 L (8.18%)Rejected-AOC | L2 | Rejected-AOC Other than lowest bidder | |
| 3 | L3₹46.8 L+₹5.3 L (12.7%)Rejected-AOC | L3 | Rejected-AOC Other than lowest bidder | |
| 4 | L4₹47.9 L+₹6.4 L (15.4%)Rejected-AOC 00 GIRDHAR GARDEN KE SAMNE KHARI PHATAK ROAD VIDISHA VIDISHA MADHYA PRADESH 464001 | VIDISHA | MADHYA PRADESH | 464001 | L4 | Rejected-AOC Other than lowest bidder | |
| 5 | L5₹48.9 L+₹7.4 L (17.8%)Rejected-AOC VILL PO KUMARHATTI DIST SOLAN HP | SOLAN | SOLAN | HIMACHAL PRADESH | L5 | Rejected-AOC Other than lowest bidder |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
23 Jan 2023, 6:00 pmClosed
Rahul Meena, IDSE, EE, Garrison Engineer
MES OFFICE GE KASAULI DISTT SOLAN HP
REPAIR TO JOINERY, TILING, PLUMBING, PLASTERING, PERIODICAL AND CERTAIN REPAIRS TO PIPE LINE, NRV, SLUICE VLAVES ETC WORKS AT DAGSHAI UNDER GE KASAULI
2022_MES_567886_2
GEK-66/2022-23
Open Tender
Miscellaneous Works
Item Rate
180 days
DAGSHAI UNDER GE KASAULI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE KASAULI
₹1 L
Yes
7 Feb 2023
9 Jan 2023
27 Jan 2023
9 Jan 2023
23 Jan 2023
16 Jan 2023
Amount
Schedule 'A' Section - I
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified.
Demolition stone slabs of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified.
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description and in position not otherwise specifically provided for complete all as specified and as directed.
Demolition of brick or stone masonary built in cement mortar including all quoins arches pillars etc but excluding ashlars facing dressed stone work and precast concrete block, complete all as specified
Demolition of Concrete of any description and in any position not otherwise specifically provided for all as specified and as directed
Taking down cement plaster on brick or stone wall, Ceilling etc including racking out joints, hacking for key scrubbing down with water etc to receive new plaster etc.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exc 1.50 sqm each .
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exc 1.50 sqm but n.exe 4.0 Sqm each .
Taking down shutter of any description exe 1 Sq.m but n.exe 2.0 Sqm each
Taking up or down waste and vent pipes of any type and any dia complete.
Dismantling wall and ceiling board (fibre, pulp, insulation, etc) or insulationboards/kitchen cupboard , any thickness etc. including cover fillets complete all as specified and directed by Engineer-in-Charge
M&L for brick work with sub class `B` bricks, in straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed
M&L for brick work with sub class `B` bricks, in straight or curved on plan in any radius , built in CM 1:4 complete all as specified and directed
M & L Rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finished even and smooth without using extra cement all as specified
M & L Rendering 15mm thick on other than fair faces of brick work or concrete surfaces in CM 1:6 finished even and smooth without using extra cement all as specified
M&L for cement concrete 1:2:4 type B-1 ( using 20mm graded stone aggregate) as in hard standing including necessary form work and finishing surface even and fair without using extra cement complete all as specified and directed
M&L Non skid ceramic coloured tiles 7mm to 8mm thick (squre/rectangular) area of each tile exc0.11sqm but not exc 0.18 sqm in floors , set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15mm thick screed bed with cement mortar 1:6 complete all as specified.
Material and labour for Glazed ceramic coloured tiles in vertical surfaces exc 0.08sqm and n exc 0.16sqm, 7mm thick, set and jointed in neat cement slurry and pointed in white or colour cement to match with and including 10mm thick backing coat on vertical surfaces of wall in cement mortar 1:4 complete all as specified and as directed.
M&L for 16 to 18 mm thick granite stone machine cut (table rubbed & polished) in one piece as in steps,jambs,pillars,windows cills,cooking platform and similar work bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigments to match the shade of granite stone including grinding and polishing including making hole in platform and screed bed for bedding 20 mm thick in cement mortar 1:6 ,complete all as specified.
Rounding to edges of stone slabs to one edge, such as in steps and other similar situations.
Cutting holes, square or circular of area exc. 0.20 and n exc 0.3) Sqm on granite slab for fixing of wash basin complete all as directed.
S&F in repairs sinks with drainage board made of stainless steel 1 mm thick kitchen or laboratory overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm with plugs, washers and wastes; including waste coupling and bedding in cement mortar to dwarf wall or fixing cantilever brackets and connecting union to pipe etc complete all as specified.and directed.
S&F in repair stop valve 15 mm cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both end for iron pipe or for union etc complete all as specified.
S&F in repair stop valve 20 mm cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both end for iron pipe or for union etc complete all as specified.
S&F in repair 15mm bore Bib taps, chromium plated cast copper alloy, fancy type, screwed down for iron pipe or for brass ferrule etc complete all as specified and directed.
Ditto as item No 25.00 above but long body.
S&F in repair 15mm bore angle cock, chromium plated, brass, fancy type, screwed both ends for iron pipe or for union etc complete all as specified and directed.
S&F in repair 15 mm bore brass Chromium plated wall/basin/sink mixer for mixing hot & cold water screwed down for iron pipe etc complete all as specified.
S&F in repair PVC bath cabinate with mirror ,complete all as specified.
S&F in repair chromium plated wall mixer 3 in one with crutch and multi flow hand shower with 1.5 mtr flexible tube (chrome) including fixing to steel pipe or unions three joints to steel pipes or union and plugging and screwing to walls etc complete all as specified
S&F in repairs Vitreous China wash hand basin white with pedastal flat back size 550x400 mm including brackets, complete all as specified
Supply and fix in repair vitreous china wash basin counter sunk type oval shape, star white including waste coupling chromium plated, fixing brackets, cutting for and pinning in ends of brackets complete all as specified and as directed.
S &F in repair for plastic water closet seat cover white closed pattern with flat bottom mild steel chromium plated or aluminium hinging device etc complee all as specified and directed.
S&F Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts,) complete incl making good to floor to match with adjoining surfaces all as directed by Engr-in-Charge
S&F as in repair fixing WC Orissa pattern of size 580x440mm white with integral foot rest (excluding flushing cistern and flush pipe) includung provision of lime concrete bedding etc complete all as specified and directed by Engr-in-Charge.
S&F in repair 10 ltr capacity PVC valveless syphonic action type flusing cistern low level white with inlet ball valve float and handle including bracket fixed etc complete all as specified
S&F in repair PVC connection 15mm bore with PTMTnuts of length 450mm etc complete all as specified
S&F in repair 32mm dia PVC flexible waste pipe for urinals/WHB/sink all as specified.
Supplying and laying of 20 mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified
Supplying and laying of 20 mm dia CPVC pipes brass Elbow fixed to CPVC pipe complete all as specified and directed
Supplying and laying of 20 mm dia CPVC pipes brassTee fixed to CPVC pipe complete all as specified and directed
S&F for 20 MM dia CPVC Brass MTA /FTA to CPVC / GI pipe all as specified directed.
S&F in repair Towel rail 600mm long chromium plated fixed in and including chromium plated brass screws and wooden/plastic cleatsetc complete all as specified.
S&F in repair 75 mm dia PVC(SWR) floor trap, with grating including jointing with solvent cement etc complete all as specified.
S&F in repair 110 mm dia PVC(SWR) 'S' trap including jointing with solvent cement etc complete all as specified.
Material and labour for precast RCC (1:2:4) type B-1 using 20mm graded mechanically crushed stone aggregate as in landing cover slab for kittchen platform manholes , septic tank set in cement mortor ( 1:6) including necessary form work complete all as specified and as directed. (Reinforcement shall be measured separately)
S&F mild steel TMT bars 10mm dia and over, cut to length, bent to shape required including crancking bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire not less than 0.5mm dia or securing with clips quality confirming to deformed or twisted bars complete all as specified and as directed.
S & F in repair 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed by the Engineer-in-Charge
S & F in repair 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and as directed by the Engineer-in-Charge
S & F in repair 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed by the Engineer-in-Charge
S & F in repair 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, walls complete all as specified and as directed by the Engineer-in-Charge
S&F in repair PVC(SWR) bend 110mm dia bore complete all as specified and directed by Engr-in-Charge
S&F in repair PVC(SWR) bend 110mm dia bore with access door complete all as specified and directed by Engr-in-Charge
S&F in repair PVC(SWR) junction single(Single T) equal or unequal 110mm dia bore with access door complete all as specified and directed by Engr-in-Charge
S&F in repair PVC(SWR) vent cowl110mm dia bore complete all as specified and directed by Engr-in-Charge
S&F in repair PVC(SWR) bend 75mm dia bore complete all as specified and directed by Engr-in-Charge
S&F in repair PVC(SWR) bend 75mm dia bore with access door complete all as specified and directed by Engr-in-Charge
S&F in repair PVC(SWR) junction single (Single T) equal or unequal 75 mm dia bore with access door complete all as specified and directed by Engr-in-Charge
S&F in repair CP toilet paper holder all as specified and as directed
S & F Soild PVC door frame of size 50mm x 47mm made out of 5mm wood grain printed PVC prelaminated sheet and edges will be painted to match wilth prelaminted sheet reinforced with MS square tube supplied and fixing in opening as per specification & drawings.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) of prelamintaed wood grain printed PVC sheet on both sides and stiles and rails feathered at edges and consisting of frame made out of M.S. tubes for top & bottom rails.M.S. frame shall be covered with heat moulded PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing.
S&F 100 mm long stainless steel butt hinges all as specified and directed.
S & F for Aluminium anodized 150 mm long barrel tower bolt of extruded section and fixed.
S&F 150mm long extruded aluminium alloy anodized handles febricated type
S&F 250 mm long Aluminium alloy anodised sliding door bolt with hasp and staple(bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolt of extruded section or cast aluminium alloy and fixed etc complete
S &F Powder Coated Anodised aluminium frame for doors, windows, parttions , ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified.
S &F powder coated aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified
S&L for sheet glass ordinary quality 4.80mm thick in aluminium windows of area of each pane exc 0.50 Sqm complete all as specificed and directed by Engr-in-Charge
S&F in repair 9mm thick pre-laminated particle board interior grade, both side lamination of approved colour and pattern fixed to wooden / aluminium frame work as in door/cupboard shutters all as specified
Material and Labour for 2nd class hard wood (Hollock) Plain fillets Exc6 & n. exc 13 sq.cm square, rectangular or triangular in section, clean sawn, secured with nails or brads,complete all as specified
M&L for 18/19 mm block boards,interior grade, fixed with screws to timber frame work complete all as specified.
S&F for 0.9 mm thick decorative laminate type 1 of surface finish colour and pattern as approved, fixed with approved adhesive as per specified and as directed
M& L for external teak wood lipping, 6mm thick fixed with nails complete all as specified and directed
S&F in repair Continuous (piano) hinges,mild steel, bright finish or elec trogalvanised , , bright finish width of flaps(when open) 30 mm complete all as specified.
S&F 100 mm long extruded stainless steel handle fabricated type anodised, complete all as specified.
S&F Hasp and staple, safety type,of aluminium anodised including bolt to hinge plate and fixed with screws 100 mm size complete all as specified.
S&F magnetic steel stopper catcher holder for cup board of approprite shape and size all as directed
S&F mild steel cupboard shutter with frame Godrej pattern, made out of 22 gauge mild steel sheet including chromium plated MS handle with proper locking arrangement (brass mortice lock vertical type, size 65mm, 4 levers with escutcheon pushes and two keys) with & including two coats of spray painting with sysnthetic enamel paint with approved tint over a coat of red oxide primer including fixing with 6 Nos 12mm dia bolt 150mm long grouted in brick wall/concrete including making good the disturbed surface as original complete all as specified and as directed.
M & L for 500 Litres rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including PTMT float valve of 15 mm dia and taking down old unserviceble PVC water tank all as specified in SSR Part-I completed and as directed by the Engr-in-Charge
S&F in repair stainless steel soap dish of approved pattern all as specified and as directed.
S&F CP grating of 100 mm da including jointing with solvent cement all as specified and as directed
S & F in repair 20mm dia,D type, 60cm long chromium plated towel rail, complete.
S&F aluminium anodised 4 pin cloth hook hanger fixed to wall complete all as specified and as directed.
M&L for cement concrete 1:2:4 type B-1 ( using 20mm graded stone aggregate) as in hard standing including necessary form work and finishing surface even and fair without using extra cement complete all as specified and directed
M&L for Preparation of newly plastered surfaces of walls and applying two coat of oil bound distempering over a coat of Chalk whitening etc complete all as specified.
M&L for preparation of new plastered surfaces of wall including cornices, pillasters etc of bldgs and applying two coat of cement base paint on walls over a coat of primer complete all as specified and directed
M&L for preparation of new plastered / unplastered surfaces of wall including cornices, pillasters etc of bldgs and applying three coat of white wash complete all as specified and directed
M&L preparation of old plastered or unplastered surfaces of walls including complete removal of existing treatment by washing, rubbing down and stopping of previously treated surfaces and applying two coat of exterior emulsion paint over a coat of primer of approved tint and make complete all as specified and directed
All as per Item No 90.00 above but one coat of exterior emulsion paint complete all as specified and directed
M&L for preparation of plastered or unplastered old surfaces of walls and applying one coat of oil bound distemper of any approved tint complete all as specified and directed
All as per Item No 92.00 above but complete removal of existing treatment and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed
M&L preparation of old painted steel surfaces exc 10cm in width or girth and appling one coat of synthetic enamel paint complete all as specified and directed
M&L for for applying 1 mm thick wall care putty of old decorated plastered or unplastered surfaces of wall complete all as specified and directed
M & L for preparation of old painted wooden surfaces of any description position and location not otherwise described over 10cms width or girth and applying one coat of synthetic enamel paint (ordinary tint) all as specified and as directed.
All as per Item No 96.00 above but applying two coat of synthetic enamel paint complete all as specified and directed
M&L for cement concrete 1:4:8 type D-2 ( using 40mm graded stone aggregate) as in sub base floor and in foundation including necessary form work and finishing surface fair and even complete all as specified and directed
M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade with grey cement and no pigment set and jointed in neat cement slurry all as specified.all as specified and as directed
M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade with grey cement and pigment set and jointed in neat cement slurry all as specified.all as specified and as directed
M&L for screed bed or bedding layer of mortar 20mm thick CM 1:6 for laying tiles and stone slab complete all as specified and directed
M&L for PCC Type B1 1: 2:4 (20 mm graded stone aggregate )Providing, cement concrete in roof kerbs or mud stops, rounded or chamfered on edges as in coping ,kneelers , appex stone, coping etc.
Removing building materials etc. (other than spoil payable under items 03028 to 03031 in Section-3 Earthwork) to a distance of 100m or beyond the lead up to 2 km included in the rates, including loading, unloading and stacking at the destination all as specified and as directed.
Excavation in trenches in hard dense soil n.exc 1.5 mtr wide & n.exc 1.5mtr in depth and n. exc. 10sqm on plan for laying pipe in trenches and getting out complete all as specified and directed.
Returning filling in trenches, spreading, levelling, watering and well ramming in layers n.exc 25cm in hard dense soil complete all as specified and directed.
Removing of surplus soil to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above starting point complete all as specified and directed.
Taking out unserviceable/defective/damaged/blockage GI pipe 15 mm bore steel water tubing,sorting out serviceable pipe fitting for reuse and cleaning the pipe including fitting and removing away all unserviceable pipe from site, complete all as specified and as directed. (Note: Exacavation and earhwork shall be measured and paid for separately.)
All as per serial item No. 107.00 here-in-before but of size 20mm bore -ditto-.
All as per serial item No. 107.00 here-in-before but of size 25 mm bore -ditto-.
All as per serial item No. 107.00 here-in-before but of size 40mm bore -ditto-.
All as per serial item No. 107.00 here-in-before but of size 50mm bore -ditto-.
All as per serial item No. 107.00 here-in-before but of size 80mm bore -ditto-.
All as per serial item No. 107.00 here-in-before but of size 100mm bore -ditto-.
S&F GI tubing medium grade, ISI Marked conforming to IS 1239 Part-I 2004, 15mm bore with and including all fittings such as bends , elbows,tees, short length, socket, union, check nuts, nipples etc. fixed and laid in trenches/floor/under culvert/road crossing etc including testing complete all as specified and as directed.
All as per serial item No. 114.00 here-in-before but of size 20mm bore -ditto-.
All as per serial item No. 114.00 here-in-before but of size 25mm bore -ditto-.
All as per serial item No. 114.00 here-in-before but of size 40mm bore -ditto-.
All as per serial item No. 114.00 here-in-before but of size 50mm bore -ditto-.
All as per serial item No. 114.00 here-in-before but of size 80mm bore -ditto-.
All as per serial item No. 114.00 here-in-before but of size 100mm bore -ditto-.
Supply & fixing vertically/ horizontally on wall & laying 150mm bore MS pipe, thickness not less than 5.40mm, flanged ends, laid in trenches including taking out old unserviceable pipe complete all as specified and directed.
Taking out old unsv and S&F Bronze gate valve for 15mm bore pipe, with iron wheel head, screwed both ends for iron pipe and fixed, ISI marked conforming to IS 778: 1984, fixed as in repair complete all as specified and directed.
All as per serial item No. 122.00 here-in-before but of size 20mm bore -ditto-.
All as per serial item No. 122.00here-in-before but of size 25mm bore -ditto-.
All as per serial item No. 122.00 here-in-before but of size 40mm bore -ditto-.
All as per serial item No. 122.00 here-in-before but of size 50mm bore -ditto-.
Taking out old unsv and S&F 15mm bore bib tap, cast copper alloy with crutch or butter fly handle, chromium plated, fancy type, screwed down(ISI marked) conforming to IS 8931: 1993, screwed for iron pipe or for brass ferrule fixed as in repair complete all as specified and directed.
Taking out old unsv and S&F 20mm bore bib tap, cast copper alloy with crutch or butter fly handle, chromium plated, fancy type, screwed down(ISI marked) conforming to IS 8931: 1993, screwed for iron pipe or for brass ferrule fixed as in repair complete all as specified and directed.
Taking out old unsv and Supplying, fixing and testing of cast iron Sluice valve PN1.6 as per IS-14846, body, dome, wedge-CI IS:210, rings-bronze IS:318, Spindal-SS IS:6603, Gland Packing greasy jute packing, fasteners-CS, Gasket- Natural rubber, nominal size DN-150 mm, both ends flanged in existing line, after removal of old unserviceable sluice valve without damaging to existing pipe line complete all as specified and directed by Engr-in-charge. Note : Suitable size flanges for existing pipe line, Joints and jointing materials shall be included under this item.
All as per serial item No. 129.00 here-in-before but nominal size DN-100 mm -ditto-.
All as per serial item No. 129.00 here-in-before but nominal size DN-80 mm -ditto-.
Taking out old unsv and S&F Water meter 150 mm nominal bore conforming to IS:2373-1981 having CI casing bronze body and SS/Alloy/Bronze gear having dial duly marked with litres or kilolitres in boldface, thread/flanged end type with provision of strainer out side the meter , fixed as in repair complete all as specified and as directed .
All as per serial item No. 132.00 here-in-before but of size 100 mm bore -ditto-.
All as per serial item No. 132.00 here-in-before but of size 80 mm bore -ditto-.
All as per serial item No. 132.00 here-in-before but of size 50 mm bore -ditto-.
All as per serial item No. 132.00 here-in-before but of size 40 mm bore -ditto-.
Construction of brick masonary pit of size 60 x 60 x 60cm internal size with MS sheet 3mm thick and angle iron frame of size 40x40x6mm duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer including locking arrangement, lifting handle and including excavation / earth work, PCC in foundation, brick work, plaster including demolition of existing pit complete all as specified and shown in drawing No. STD- 1258, sheet 1/1. (original date - 30.11.93 and revised date - 15.09.2000 ) Note : Drawing mentioned above has not been enclosed herewith, however the same can be seen in the office of GE Kasauli.
Construction of brick masonary pit of size 90 x 90 x 90 cm internal size with MS sheet 3mm thick and angle iron frame of size 40x40x6mm duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer including locking arrangement, lifting handle and including excavation / earth work, PCC in foundation, brick work, plaster including demolition of existing pit complete all as specified and shown in drawing No. STD- 1258, sheet 1/1 (original date - 30.11.93 and revised date - 15.09.2000 ) Note : Drawing mentioned above has not been enclosed herewith, however the same can be seen in the office of GE Kasauli.
Construction of brick masonary pit of size 120 x 120 x 120cm internal size with MS sheet 3mm thick and angle iron frame of size 40x40x6mm duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer including locking arrangement, lifting handle and including excavation / earth work, PCC in foundation, brick work, plaster including demolition of existing pit complete all as specified and shown in drawing No. STD- 1258, sheet 1/1. (original date - 30.11.93 and revised date -15.09.2000) Note : Drawing mentioned above has not been enclosed herewith, however the same can be seen in the office of GE Shimla hills Kasauli.
Dismantling and taking out old flanged and drilled pipe line complete with all fittings and flanged joints,150mm dia, including necessary excavation ,returning and filling etc complete, removing unserviceable from site and transporting out of site complete all as specified and directed by Engr-in-charge.
Supplying, laying, jointing and testing hot finished seamless carbon steel pipe not less than YST-240, grade B as per ASTM A 106, Sch 40, nominal size NPS-150 mm, outer dia 168.30 mm, with nominal wall thickness 7.1 mm and weight 28.22 Kg/ Rm, including short pieces as required at site, laid in trenches/over RCC pillars/across or under bridges/along hill side (up or down)/culverts/inside valve pits complete all as specified snd directed by Engr-in-charge. NOTE:- (i) Excavation Earth work, PCC, seamless pipe fittings, MS flanges & flanged joints shall measured and paid for separatly under relevant items. (ii) Work will be carried out in piecemeal loacations experienced based on break downs and weaker sections of existing rising main as per site requirement and as directed by Engineer-in-charge. (iii) Any other expenses including permision from state authorities are included under this item.
Supplying, laying, jointing and testing bends, suitable length, radius as specified and as per site requirement, made of hot finished seamless carbon steel pipe not less than YST-240, grade B as per ASTM A 106, Sch 40, nominal size NPS-150 mm, outer dia 168.30 mm, with nominal wall thickness 7.1 mm and weight 28.2 Kg/ Rm, including short pieces with flanged ends duly fabricated as required at site, laid in trenches/over RCC pillars/across or under bridges/along hill side (up or down)/culverts/inside valve pits complete all as specified snd directed by Engr-in-charge. NOTE:- As per item No - 141.00.
Supplying, laying, jointing and testing of Tees, suitable length and as per site requirement, made of hot finished seamless carbon steel pipe not less than YST-240, grade B as per ASTM A 106, Sch 40, nominal size NPS-150 mm, outer dia 168.30 mm, with nominal wall thickness 7.1 mm and weight 28.2 Kg/ Rm, including short pieces with flanged ends duly fabricated as required at site, laid in trenches/over RCC pillars/across or under bridges/along hill side (up or down)/culverts/inside valve pits complete all as specified and directed by Engr-in-charge. NOTE:- As per item No - 141.00.
Supply and fixing heavy duty MS flange of nominal size DN-150, duly painted with two coats of black japan paint, for NPS-150 mm nominal size pipes, 36 mm thick, 345 mm outer dia, having 8 nos hole of size 33 mm drilled for M30 size bolts for jointing with existing pipes,duly welded with pipes/tees/bends properly to both the plain ends complete all as specified and directed by Engr-in-charge.
Flanged joint for 150mm nominal size pipes comprising of one 3.0 mm steel reinforced compressed asbestos fibre gasket and 8 nos nuts, bolts of size M30 and 125 mm length and 2 nos washers 3 mm thick for each bolt to joint pipes/fittings/bends etc complete all as specified and directed by Engr-in-charge.
Supplying, fixing and testing of high pressure, heavy duty cast steel sluice valve, nominal size DN-150 mm, conforming to API 600, Class 600, suitable to hydrostatic test pressure for body 156 kg/sq cm & for seat 115 kg/sq cm, both ends flanged in existing line, after removal of old unserviceable gate valve without damaging to existing pipe line complete all as specified and directed by Engr-in-charge. Note : Suitable size MS flanges for existing pipe line, Joints and jointing materials shall be included under this item.
Supplying, fixing and testing of high pressure, heavy duty cast steel non return valve/ check valve, nominal size DN-150 mm, conforming to BS 1868, Class 600, suitable to hydrostatic test pressure for body 156 kg/sq cm & for seat 115 kg/sq cm, both ends flanged in existing line, after removal of old unserviceable non return valve without damaging to existing pipe line complete all as specified and directed by Engr-in-charge. Note : Suitable size MS flanges for existing pipe line, Joints and jointing materials shall be included under this item.
Two coats of synthetic enameled paint (tint of paint as directed) over one coat of red oxide primer on surfaces over 10 cm width or girth including preparation of new surfaces on mild steel pipe including fittings, Gate valve and NRV etc complete from tank to pump set and from pump set to delivery gate valve in Pit chamber , and writing names/letters using white paint as directed at different locations of water supply installation at kasauli complete all as specified and directed by Engineer-in-charge.
Dismantling of defective/unsv 150 mm nominal size pipe line and taking out from trenches with necessary excavation work and carrying out the reapir work at site or local wk shop for welding work to repair defective portion of pipe line and providing leak proof jointing material to leaked/pierced portion and took back after repair to work site complete and relaying of repaired pipe line 150mm bore in trenches and jointing the same in trenches complete with new gasket, nut bolts and other jointing material including testing/commissioning the pipe line on full pressure complete all as specified and directed by Engr-in-charge. NOTE :- (i) MS flanges & flanged joints shall measured and paid for separatly under relevant items. (ii) Work will be carried out in piecemeal loacations experienced based on break downs and weaker sections of existing rising main as per site requirement and as directed by Engineer-in-charge.
Dismantling of defective/unsv 100 mm nominal size pipe line and taking out from trenches with necessary excavation work and carrying out the reapir work at site or local wk shop for welding work to repair defective portion of pipe line and providing leak proof jointing material to leaked/pierced portion and took back after repair to work site complete and relaying of repaired pipe line 100mm bore in trenches and jointing the same in trenches complete with new gasket, nut bolts and other jointing material including testing/commissioning the pipe line on full pressure complete all as specified and directed by Engr-in-charge. NOTE :- (i) MS flanges & flanged joints shall measured and paid for separatly under relevant items. (ii) Work will be carried out in piecemeal loacations experienced based on break downs and weaker sections of existing rising main as per site requirement and as directed by Engineer-in-charge.
PCC (1:3:6) type C2 using 40mm graded stone aggregate for anchorage blocks for pipe line/making good the cut portion of roads/paths/hard standings etc including necessary from work where required , to support the pipe line complete all as specified and as directed by Engineer-in-charge.
Cross arms bracings, support, clamps and back plates fabricated from structural steel section including nuts, bolts, washers etc, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminum paint complete all as specified and directed by Engineer-in-charge.
Supply of calcium hypo chloride, 65%-70% chlorine content, high strength granular disinfectant for treatment of drinking water complete all as specified and qty as per requirement and as directed by Engr-in-Charge.
S&F MCCB 630 Amps 4 pole, 50 KA, 415 V, 50 Hz with thermal setting between 70% to 100%, adjustable type and connecting up in the existing panel location including taking out existing unserviceable MCCB complete all as speciified and as directed by Engineer-in-charge.
S&F MCCB 400 Amps 4 pole, 35 KA, 415 V, 50 Hz with thermal setting between 70% to 100%, adjustable type and connecting up in the existing panel location including taking out existing unserviceable MCCB complete all as speciified and as directed by Engineer-in-charge.
S&F MCCB 250 Amps 4 pole, 35 KA, 415 V, 50 Hz with thermal setting between 70% to 100%, adjustable type and connecting up in the existing panel location including taking out existing unserviceable MCCB complete all as speciified and as directed by Engineer-in-charge.
S & F in repair/replacement Flanged rubber gasket of 3.0 mm thickness for 100/150mm nominal size pipes comprising of suitable holes for attachments, complete all as specified and directed by Engr-in-charge.
M & L electronic Water level indicator electrically operated digital type showing indication of water of under ground sump/ main service tank installed at various location of Dagshai station any capacity not below 2000 gallons including taking out existing mechanical water level indicator complete all as specified and directed.
Disconnecting /unscrewing coupling for 220/240 HP pump set and seperating pump and motor, disconnecting all water connections from pump including suction and discharge pipe line and taking out the pump from base frame, transporting to workshop to carry out the necessary repairs and took back after repairs , installing on existing location ,making all the connections carefully, commissioning and testing at site to the entire satisfaction of the Engr-in-Charge. Note: All the Spares/ parts/ job repairs required to be replaced shall be measured and paid seperately as under:- Note : Attend the complaint with in 12 Hrs and after repairing the same to be fixed and testing within 48 Hrs.
Coupling Set suitable for 220/240 HP Pumping set
Replacement of gun metal impeller
Replacement of gun metal Bush
Replacement of Gland Sleeve
Replacement of body Neck ring gun metal
Replacement of Pump shaft stainless steel
Counter Plate stainless steel
Diffuser Packing
Impeller brazing machining and reboring
New Key way of impeller disc
Diffuser outer dia brazing and machining
Impellers outer dia brazing and machining
Disconnecting /unscrewing coupling for 125HP to 150 HP pump set and seperating pump and motor, disconnecting all water connections from pump including suction and discharge pipe line and taking out the pump from base frame, transporting to workshop to carry out the necessary repairs and took back after repairs , installing on existing location ,makng all the connections carefully, commissioning and testing at site to the entire satisfaction of the Engr-in-Charge. Note: All the Spares/ parts/ job repairs required to be replaced shall be measured and paid seperately as under:- Note : Attend the complaint with in 12 Hrs and after repairing the same to be fixed and testing within 48 Hrs.
Coupling Set suitable for 125HP to 150 HP Pumping set
Replacement of gun metal impeller
Replacement of gun metal Bush
Replacement of Gland Sleeve
Replacement of body Neck ring gun metal
Replacement of Pump shaft stainless steel
Counter Plate stainless steel
Diffuser Packing
Impeller brazing machining and reboring
New Key way of impeller disc
Diffuser outer dia brazing and machining
Impellers outer dia brazing and machining
Disconnecting /unscrewing coupling for 60 HP to 75 HP pump set and seperating pump and motor, disconnecting all water connections from pump including suction and discharge pipe line and taking out the pump from base frame, transporting to workshop to carry out the necessary repairs and took back after repairs , installing on existing location ,makng all the connections carefully, commissioning and testing at site to the entire satisfaction of the Engr-in-Charge. Note: All the Spares/ parts/ job repairs required to be replaced shall be measured and paid seperately as under:- Note : Attend the complaint with in 12 Hrs and after repairing the same to be fixed and testing within 48 Hrs.
Coupling Set suitable for 60 HP to 75 HP Pumping set
Replacement of gun metal impeller
Replacement of gun metal Bush
Replacement of Gland Sleeve
Replacement of body Neck ring gun metal
Replacement of Pump shaft stainless steel
Counter Plate stainless steel
Diffuser Packing
Impeller brazing machining and reboring
New Key way of impeller disc
Diffuser outer dia brazing and machining
Impellers outer dia brazing and machining
Taking out old unserviceable with replacement of pressure gauge upto 100 Kg/sqcm, complete all as speciified and as directed by Engineer-in-charge.
Taking out old unserviceable with replacement of ball bearing 6314, complete all as speciified and as directed by Engineer-in-charge.
Taking out old unserviceable with replacement of ball bearing 6315, complete all as speciified and as directed by Engineer-in-charge.
Taking out old unserviceable with replacement of ball bearing 6319, complete all as speciified and as directed by Engineer-in-charge.
Taking out old unserviceable with replacement of roller bearing NU 207, complete all as speciified and as directed by Engineer-in-charge.
Taking out old unserviceable with replacement of roller bearing NU 307, complete all as speciified and as directed by Engineer-in-charge.
Disconnecting existing electric motor and dismantling from foundation and transporting the same to the workshop for repairs and refixing the same on existing location after repair & making electric connection including testing and commissionig complete. including taking out burnt winding and rewinding the motor with super enamelled copper wires as per existing guage and size including super quality of varnish and insulating material as required for 220/240 HP electric motor complete all as speciified and as directed by Engineer-in-charge. Note : Attend the complaint with in 12 Hrs and after repairing the same to be fixed and testing within 48 Hrs.
-ditto- all asper Item No. 168.00 above but of capacity 150 HP.
-ditto- all as per item No. 168.00 above but of capacity 125 HP.
-ditto- all as per item No. 168.00 above but of capacity 75 HP.
-ditto- all as per item No. 168.00 above but of capacity 60 HP.
Disconnecting /unscrewing Auto Transformer Starter Panel of capacity 150-220 HP, disconnecting all electric connections and carrying out necessary repair at site with replacement of parts as under complete all as specified including testing at site to the entire satisfaction of the Engr-in-Charge. Note: All the Spares/ parts/ job repairs required to be replaced shall be measured and paid as under:
Disconnecting /unscrewing Auto Transformer Starter Panel of capacity 60-75 HP, disconnecting all electric connections and carrying out necessary repair at site with replacement of parts as under complete all as specified including testing at site to the entire satisfaction of the Engr-in-Charge. Note: All the Spares/ parts/ job repairs required to be replaced shall be measured and paid as under:
Electronic over current relay cap 0.5 – 60A 220V AC complete with arrangement for over current, phase reversal, under current and phase imbalance protection suitable for 125-240 HP ATS Panel complete all as speciified and as directed by Engineer-in-charge.
Electronic over current relay cap 0.5 – 60A 220V AC complete with arrangement for over current, phase reversal, under current and phase imbalance protection suitable for 60-75 HP ATS Panel complete all as speciified and as directed by Engineer-in-charge.
Three pole power contactor, AC Control, AC3 Rating 95A/ 47 KW, 415V complete with auxillary contact heavy duty suitable for pumping set operation including taking out existing unserviceable power contactor and removal from site complete all as speciified and as directed by Engineer-in-charge.
Three pole power contactor, AC Control, AC3 Rating 140A/ 75 KW, 415V complete with auxillary contact heavy duty suitable for pumping set operation including taking out existing unserviceable power contactor and removal from site complete all as speciified and as directed by Engineer-in-charge.
Three pole power contactor, AC Control, AC3 Rating 265A/ 140 KW, 415V complete with auxillary contact heavy duty suitable for pumping set operation including taking out existing unserviceable power contactor and removal from site complete all as speciified and as directed by Engineer-in-charge.
Three pole power contactor, AC Control, AC3 Rating 300A/ 160 KW, 415V complete with auxillary contact heavy duty suitable for pumping set operation including taking out existing unserviceable power contactor and removal from site complete all as speciified and as directed by Engineer-in-charge.
No volt coil complete all as speciified and as directed by Engineer-in-charge.
Timer complete all as speciified and as directed by Engineer-in-charge.
Indicator set RYB 01 set of 3 pcs.
M&L for reparing/servicing of APFC panel board of Cap 135-150 KVAr by replacing the all defective components with new components, rewiring, cleaning, testing, reconnecting, reinstalling and commissioning the APFC panel board complete all as direcetd by Engineer-in-Charge. Note : Supply of cables, wires & other minor spare parts etc will deemed to be included in the quoted rate.
All as per item No 187.00 here in before but of cap 100-125 KVAr.
All as per item No 187.00 here in before but of cap 50-75 KVAr.
Earthing complete with galvanised steel earth electrode plate of size 600x600x6mm thick, buried directly in ground(earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below normal ground level, connected to galvanised iron earth strip 32x6mm up to test point with suitable GI nuts/bolts and brazed properly up to main board including earth pit in cement concrete 1:2:4 type B-1, precast RCC cover in 1:2:4 reinforced with expanded metal, with suitable handle, excavation and earth work in any type of soil and including medium grade GI watering pipe 25mm bore with funnel wire mesh and medium grade GI earth wire protection pipe 50mm bore up to main board complete as shown in electrical plate no 3 of MES schedule Part-I 2009, connected to earthing testing point including taking out existing unsv earthing complete all as specified and testing on completion complete all as specified and directed by Engr-in-charge. Note : The units rate includes the cost of excavation & earth work in any type of soil charcoal & salt in altemate layers, 25mm GI Pipe (light grade) for watering 50mm GI protection pipe (light grade) funnel wire mesh PCC chamber in PCC 1:3:6 type C-1 cast iron frame and 40mm thick RCC cover for pit etc & no extra payment will be made.
Supply & Fixing in repair/replacement GI pipe 100 mm dia light grade along pole for covering cable including clamp, nuts, bolts & washers etc complete all as specified.
Supply & Fixing double walled corrugated HDPE duct pipe of 120 mm outer dia confirming to IS: 14930 (Part-II) of approved colour with fittings for cable protection complete all as specified.
Supply, laying, jointing and testing replacement PVC insulated cable 1100 volt grade with multi stranded, single core copper 95 Sqmm, Grade As Per IS 7098 (Part -1) 1988 including making electrical connection for main panel, to starter and starter to motor in pieces of suitable length as per site requirement duly fixed with suitable size of copper lugs/thimbles complete all as specified and as directed by Engr-in-charge.
Supply, laying, jointing and testing replacement PVC insulated cable 1100 volt grade with multi stranded, single core copper 120 Sqmm, Grade As Per IS 7098 (Part 1) 1988 including making electrical connection for main panel, to starter and starter to motor in pieces of suitable length as per site requirement duly fixed with suitable size of copper lugs/thimbles complete all as specified and as directed by Engr-in-charge.
Supply, laying, jointing and testing replacement PVC insulated cable 1100 volt grade with multi stranded, single core copper 185 Sqmm, Grade As Per IS 7098 (Part 1) 1988 including making electrical connection for main panel, to starter and starter to motor in pieces of suitable length as per site requirement duly fixed with suitable size of copper lugs/thimbles complete all as specified and as directed by Engr-in-charge.
S&F for replacement of battery 12 V 180 Ah maintenance free, including taking down all as specified and direcetd by Engr-in-Charge
S & F in replacement of Start Push button for ATS Panel all as per existing and all as specified and direcetd by Engr-in-Charge
S & F in replacement of Stop Push button for ATS Panel all as per existing and all as specified and direcetd by Engr-in-Charge
S & F in replacement of Meter indicator of one phase of Servo Voltage Stablizer of rated capacity 300 KVA; rated voltage 240V, 3 phase 50 Hz all as specified and direcetd by Engr-in-Charge
S & F in replacement of Program Controller card of capacity 150 KVAr for APFC Panel all as specified and direcetd by Engr-in-Charge
S & F in replacement of Program Controller card of capacity 200 KVAr for APFC Panel all as specified and direcetd by Engr-in-Charge.
S & F in replacement of MC Contactor of 25 KVAr capacity for APFC Panel all as specified and direcetd by Engr-in-Charge.
S & F in replacement of MC Contactor of 10 KVAr capacity for APFC Panel all as specified and direcetd by Engr-in-Charge.
S & F in replacement of MC Contactor of 05 KVAr capacity for APFC Panel all as specified and direcetd by Engr-in-Charge.
S & F in replacement of Heavy Duty Capacitor of 20 KVAr capacity for APFC Panel all as specified and direcetd by Engr-in-Charge.
S & F in replacement of Heavy Duty Capacitor of 10 KVAr capacity for APFC Panel all as specified and direcetd by Engr-in-Charge.
S & F in replacement of Heavy Duty Capacitor of 1 to 5 KVAr capacity for APFC Panel all as specified and direcetd by Engr-in-Charge.
S&F in replacement of Rubber Mat of size ( 1 Meter x 2 meter x 19mm) uses in pumps house for safety purposes for operators as specified and directed by Engineer in charge.
Supply only PTFE Gland packing white colour 12 mm of square shape as specified and directed by Engineer in charge.
Supply only Grease yellowish of Grade- 3 in a bucket/barrel of 1kilogram for industrial appliation as specified and directed by Engineer in charge.
Supply only high quality Lubrication Oil in a bucket/barrel of 1 Ltr as specified and directed by Engineer in charge.
S & F in replacement of Copper Thimble of below mentioned sizes(dia ) as specified and directed by Engineer in charge.
Supply only Gasket sheet of 3mm to 5mm thickness of high pressure bearing capacity as specified and directed by Engineer in charge.
Supply only high quality Gear Oil of SAE class 80W90 in a bucket/barrel of 1 Ltr as specified and directed by Engineer in charge.
S & F in replacement of current transformer 250/5A, Class 1 ID 45 CT With 15 VA for Ammeter with current rating 5.0 amps for ATS panel, all as specified and direcetd by Engr-in-Charge.
S & F in replacement of Change Over Switch of rating 400A of Servo Voltage Stablizer of rated capacity 300 KVA; rated voltage 240V with 3 no of phases , all as specified and direcetd by Engr-in-Charge.
S & F in replacement of sign board of size 2x1 Sqm with detailed schematic diagram of water supply installations with proper arrangement to fix on angle/column, complete all as specified and directed by engineer in charge.
S&F in replacement of shock treatment chart in multi languages i.e english and hindi of size 2 x1 Sqm with proper arrangement to fix, complete all as specified and directed by engineer in charge.
Amount of credit of Rs. 159761.40 for retrived old material as mentioned in Schedule 'A' section-II of tender document in pdf form, will be deducted offline while acceptence of tender.
Arsh Builder
R. P. Suppliers and Construction Co.
S R AND CO
Vishal Builder
M/S PARMOD KUMAR
R B TRADERS
M/S Lekh Ram Sharma and Sons
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .