Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.1 LAccepted-AOC 06 DATALPARA A K DEV ROAD DATALPARA KAMRUP ASSAM 781025 UDYAM AS 03 0016239 | KAMRUP METRO | ASSAM | 781025 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹21.6 L+₹34,116.75 (1.60%)Rejected-Finance BORBARUAH BAZAR A T ROAD DIBRUGARH ASSAM | L2 | Rejected-Finance Higher bid value | |
| 3 | L3₹23.6 L+₹2.3 L (10.8%)Rejected-Finance | L3 | Rejected-Finance Higher bid value | |
| 4 | L4₹24.0 L+₹2.7 L (12.6%)Rejected-Finance | L4 | Rejected-Finance Higher bid value | |
| 5 | L5₹24.1 L+₹2.8 L (13.1%)Rejected-Finance A 153 HQ CE EC KOLKATA LEKHAPANI POST TINSUKIA DIST ASSAM STATE | L5 | Rejected-Finance Higher bid value |
Tender Value
₹21.2 L
EMD Value
₹42,400
Closing Date
20 Aug 2022, 6:00 pmClosed
GE DINJAN
GE DINJAN, PANITOLA (PO), DIBRUGARH (DIST), ASSAM
PROVN OF 01 X TOILET BLOCK FOR OR LIVING ACCN (Bldg No. T-7-10A) OF 2 MTN DIV SIG REGT AND CERTAIN REVENUE AND MINOR WORKS UNDER GE DINJAN
2022_MES_541541_1
C/8467/E8
Open Tender
Civil Works
Item Rate
180 days
DINJAN MIL STN
AS PER TENDER DOCUMENT
9 documents required · 9 mandatory
₹500
GE DINJAN
₹42,400
Yes
28 Sept 2022
28 Jul 2022
22 Aug 2022
28 Jul 2022
20 Aug 2022
12 Aug 2022
Amount
Surface dressing not exceeding 15 cm deep and getting out in soft/loose soil complete all as specified and as directed.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and as directed.
Excavation in post holes (or similar holes) each not exceeding 0.5 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering and removing surplus soil to a distance not exceeding 50m and making good surfaces in soft/loose soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation, or for shafts, wells, cesspits, manholes, pier holes, or laying of cables, poles, etc area not exceeding 10 Sqm on plan and getting out in soft/loose soil complete all as specified and as directed.
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified and as directed.
Removal of surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above starting point complete all as specified and as directed.
Removal of surplus excavated material/soil to a distance eceeding 250m but not exceeding 500 m and depositing where directed by Engr-in-charge.
M&L for hardcore of brocken stone/brick of gauge not exceeding 63 mm, deposited, spread, and leveled in layers not exceeding 15 cm thick, watered and rolled / rammed to a true surfaces complete all as specified and as directed.
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
M&L for PCC, type E2 (1:5:10), (using 40mm graded broken stone aggregate) as in sub base of floor and mass concrete, etc complete all as specified and as directed.
M&L for PCC, type D2 (1:4:8), (using 40mm graded broken stone aggregate) as in foundations, filling and mass concrete, pole etc complete all as specified and as directed.
M&L for PCC, type C2 (1:3:6) (using 40mm graded broken stone aggregate) as in foundations, filling and mass concrete, pole etc complete all as specified and as directed.
M&L for PCC, type C2 (1:3:6), (using 40mm graded broken stone aggregate) as in surface channels and drains etc complete all as specified and as directed.
M&L for RCC (design mix), type M-25, (20 mm graded agg) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
M&L for RCC (design mix), type M-25, (20 mm graded agg) as in chajja etc complete all as specified and as directed.
M&L for RCC (design mix), type M-25, (20 mm graded agg) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
M&L for RCC (design mix), type M-25, (20 mm graded agg) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
M&L for RCC (design mix), type M-25, (20 mm graded agg) in column, pillar, piers, post and struts complete all as specified and as directed.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar work complete all as specified and as directed.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions etc rough finished flat surface of concrete complete all as specified and as directed.
Formwork to chullah hoods, chajjas, troughs and similar items including edges complete all as specified and as directed.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. rough finished flat surface of concrete complete all as specified and as directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200mm thick (horizontal or sloping) complete all as specified and as directed.
M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for TMT bars 05 mm and over upto and incl 10 mm dia for stirrups, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. .
M&L brick work with sub class 'B' bricks, straight or curved on plan exceeding 6m mean radius, built in cement mortar (1:6) complete all as specified and as directed.
M&L brick work with sub class 'B' bricks, straight or curved on plan to any radius, built in cement mortar (1:4) as in half brick thick walls complete all as specified and as directed.
M&L for 15 mm thick rendering on fair faces of brick work or concrete surfaces in CM (1:6) including finished the surface even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 15 mm thick on fair faces of external wall of brick work or stone surfaces in two layers (10 mm and 5 mm thick) in cement mortar in (1:4) using water proofing compound in top layer and finished even and smooth without using extra cement complete all as specified and as directed. Note: water proofing compound measured and paid separately
M&L for 15 mm thick rendering on fair faces of brick work or concrete surfaces in CM (1:4) including finished the surface even and smooth with using extra cement complete all as specified and as directed.
M&L for rendering 10 mm thick of fair faces of brick work or concrete surfaces in cement mortar in (1:6) and finished even and fair complete all as specified and as directed.
M&L for rendering 5 mm thick in cement mortar (1:3) on concrete surfaces as in ceilings (sunshed, chajja etc) and finishing surfaces even and smooth without using extra cement complete all as specified and as directed.
Supply only liquid water proofing compound complete all as specified and as directed.
M&L for coloured glazed ceramic tiles in vertical surface of size 450X 350X 7 mm thick over 10 mm thick back coat of cement mortar in (1:4) set and jointed in neat cement slurry and pointed in white or colour cement to match over complete all as specified and as directed.
M&L for non-skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed or bedding layer of cement mortar in (1:6) for laying floor finishes complete all as specified and as directed.
M&L for 100mm thick PCC, type C2, (1:3:6), (using 40mm graded broken stone aggregate) as in floor laid in panels, sub base etc complete all as specified and as directed.
M&L for 75 mm thick, plain cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) as in plinth protection/ hard standing etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand (1:2) complete all as specified and as directed.
M&L for chequered cement concrete tiles of size 30cm x 30cm x 25mm thick, as in floors etc, including 15 mm thick screed bed in cement mortar (1:6) and set & jointed in neat cement slurry and pointed in grey cement and pigments to match with the shade of tiles complete all as specified and as directed.
M&L for 100 mm thick, plain cement concrete (1:2:4) type B-2 (using 40mm graded stone aggregate) as in floor, hardstanding etc, finishing cement concrete surface even and smooth without using extra cement complete all as specified and as directed.
S&F for factory made solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, supplying & fixing in opening as per specification & drawing complete all as specified and as directed.
S&F for factory made solid panel PVC door shutter, 30 mm thick (style) consisting of frame, made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing in SSR Part II 2010 complete all as specified and as directed
S&F for 75mm long butt hinges, medium weight, cold rolled stainless steel fixed to chowkats complete all as specified and as directed.
S&F for aluminium anodised barrel tower bolts of extruded section 150 mm long complete all as specified and as directed.
S&F for aluminium handle 150 mm long cast type, anodised extruded fabricated type complete all as specified and as directed.
S&F for steel ventilator with top hung shutter including hinges, steel peg stay, complete complete all as specified and as directed.
S&F for 4 mm thick figured glass, pin head type and glazing with oil putty in squares not exceeding 0.5 sqm in each pane complete all as specified and as directed.
S&F for PVC low level flushing cistern, 10 liter capacity, valveless, symphonic action type with inlet, ball valve, float and handle incl bracket, PVC connection pipe and flush pipe of polyethylene of low or high density complete all as specified and as directed.
S&F for vitreous china squatting pan Orissa pattern of size 580mmx440 mm white, with integral foot rests connected with 'P' or 'S' trap (excluding flushing cistern and flush pipe) and provn of lime concrete bedding complete all as specified and as directed.
S&F for vitreous china wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) front or back inlet including connection to drain ( outgoing pipe) and to flushing pipe, anti syphonage pipe, etc and making good to existing surface complete all as specified and as directed.
S&F for vitreous china wash hand basin white flat back size 550x400mm excluding taps, waste chain and plug and porcelain stopper including cutting for and pinning in ends of brackets or erecting stand (exclusive of fixing of supply and waste pipe) complete all as specified and as directed.
S&F for vitreous china urinals bowl, half stall type, white (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar (1:2), securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and union for discharge pipe (exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and as directed.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exceeding 10 cm but not exceeding 20 cm girth complete all as specified and as directed.
S&F for 15 mm bore dia bib taps, chromium plated cast copper alloy, fancy type, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
S&F for 15 mm bore dia angular stop cock/ stop valves, chromium plated cast copper alloy, fancy type, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
S&F for 15 mm bore dia pillar taps, chromium plated, cast copper alloy, fancy type, with capstan heads, screwed down high pressure, with or without lettered 'Hot' or cold with long screwed shanks and fly nuts screwed for iron pipe complete all as specified and as directed.
S&F for 15 mm bore dia stop valves (concealed type), chromium plated cast copper alloy, fancy type, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
S&F for PVC connections 15mm size with PTMT nuts of length 450 mm long complete all as specified and as directed.
S&F for brass chromium plated shower rose, 125 mm size with or without swivel joint any size incl fixing to steel pipe or union complete all as specified and as directed.
M&L for 75 mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement including disconnection of old existing trap, and connected with existing water pipe complete all as specified and as directed.
S&F for salt glazed stoneware gully traps of size 150x150 mm square or round moulded, type 'P' complete all as specified and as directed.
S&F for 20 mm bore, gun metal, gate valve with iron wheel head, screwed both ends for iron pipes and fixed complete all as specified and as directed.
S&F for 50 mm bore, high density polyethylene pipes (HDPE) of pressure rating 6 kgf/ Sqcm in waste pipe for WHB or sink complete all as specified and as directed.
S&F for 15 mm bore, steel tubes, galvanised, medium grade with all fittings & fixed complete to wall and ceiling or laid in floors etc complete all as specified and as directed.
S&F for 20 mm bore, steel tubes, galvanised, medium grade with all fittings & fixed complete to wall and ceiling or laid in floors etc complete all as specified and as directed.
S&F for tubular towel rail, 20mm dia, D-type, 60cm long brass chromium plated between flanges complete all as specified and as directed.
M&L for salt glazed stoneware drain pipes 150mm internal dia grade 'A' laid in trenches and jointed complete all as specified and as directed.
S&F for 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.
S&F for 110 mm bore PVC (SWR) bends any radius complete all as specified and as directed.
S&F for 110 mm bore PVC (SWR) bends with access door complete all as specified and as directed.
S&F for 110 mm bore PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and as directed.
S&F for 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.
S&F for 75 mm bore PVC (SWR) bends any radius complete all as specified and as directed.
S&F for 75 mm bore PVC (SWR) bends with access door complete all as specified and as directed.
S&F for 75 mm bore PVC (SWR) vent cowl complete all as specified and as directed.
S&F for PVC (SWR) reducers complete all as specified and as directed.
M&L for PCC (1:3:6) type C-2 (using 40 mm graded stone aggregate) as in bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested complete for 150 mm bore drain pipes complete all as specified and as directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required for 150mm internal dia of pipe complete all as specified and as directed.
M&L for rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of capacity 500 ltrs hoisted and fixed in position all as specified in SSR Part-1 including dismantling water tank and removing to store complete all as specified and as directed.
S&F for 20 mm bore dia of pipe, Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (minimum weight 20 mm - 210 gms) complete all as specified and as directed.
M&L for preparation of new surfaces of steel or iron surface of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
M&L for preparation of new plastered surfaces and applying three coat of white wash on ceiling complete all as specified and as directed.
M&L for preparation of new plastered surfaces and applying three coat of white wash on wall complete all as specified and as directed.
S&F for mild steel bolts purpose made with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut with washers exceeding 30cm long and dia of neck exceeding 12mm and not exceeding 20mm complete all as specified and as directed.
S&F for rolled mild steel work in square/ rectangular/ tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and as directed.
M&L for rolled mild steel work in plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment conforming to Fe 410-W (Gde-E- 250) complete all as specified and as directed.
S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of profile as approved, any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F for pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges/valley gutter, fixed with self tapping screws complete all as specified and as directed. Note : Colour of ridge shall be same colour as that of sheet used for roof.
M&L concealed point wiring complete with 1.5 sqmm FRLSH, PVC insulated multi stranded copper conductor single core cable 1100 volts grade, drawn into non metallic PVC rigid conduit medium grade of 20mm dia and conduit accessories and fittings like bend, elbows, crosses wall crossing etc. including cutting, chasing and pinning fixed on wall, floor, roof and including provision of PVC insulated FRLS 1.5 sqmm copper conductor for earth continuity and connected to common earth dolly and modular metal flush boxes concealed in wall and modular cover plate with frame for housing the switches socket outlet, fan regulator etc, including testing on completion etc all as specified and directed for one light/ fan point controlled by one way 6 Amp modular switch . Note : Cost of modular metal flush boxes and cover plates frame are deemed to be included in unit rate.
All as per item No. 88 above but wiring with cables of size 2.5 sqmm & cables of size 2.5 sqmm as continuous earth wire for one 3 pin socket outlet, 5/15 Amps on Independent board complete all as specified and as directed.
S&F for switch piano, 5 Amp single pole, flush type one way 230 volts bearing ISI marked complete all as specified and as directed.
S&F for switch socket combination, 2 in 1, 5/16 Amps, 240 volts, bearing ISI marked flush type complete all as specified and as directed.
S&F for ceiling rose, 3 phase/PVC/polycarbonate, isolated body bearing ISI marked and including PVC box complete all as specified and as directed.
S&F in repair lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.
S&F in repair LED bulb of 9 Watt complete all as specified and as directed. Make : Havells /Philips/Bajaj /Surya.
S&F for 20 Watt, surface and wall mounting type LED batten with polycarbonate housing & integrated complete all as specified and as directed. Make : Havells/Philips/Bajaj/Crompton/Century.
S&F in repair Factory made board distribution (DB) double door in sheet steel enclosure with common bus bar at incoming end, SPN, 4 way, 240 Volts suitable for housing MCBs including complete all as specified and as directed.
S&F for MCB, double pole, 240 Volts, 6 to 32 Amps, 'C' Series, 10KA capacity complete all as specified and as directed.
S&F for MCB, 'C' Series, single pole, 240 Volts, 6 to 32 Amps, 'C' Series, 10KA capacity complete all as specified and as directed.
M&L for concealed sub main wiring with two run of 4 Sqmm (nominal area) single core cable PVC insulated, multistranded, unsheathed, copper conductor cables (FRLSH), 1100 Volts grade drawn through PVC casing-caping/conduit of suitable size, fixed to wall/ceiling etc including one run of 4 Sqmm (nominal area) single core, PVC insulated, multistranded, unsheathed, copper conductor (FRLSH) as earth wire and duly connected to common earth point complete all as specified and as directed. Note : (a) PVC Casing-caping/conduit, two run wiring cables and one run of earth wire will be measured as one length (b) All incoming and outgoing cable shall be connected by using proper lugs & sockets.
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to 4mm GI wire by means of bolts and nuts checknuts and washers protected by 20mm bore galvanised iron light grade pipe, funnel with 40mm bore GI medium grade pipe for watering, wire mesh including concrete pit PCC 1:3:6 type C1, precast RCC 1:2:4 type B1 cover slab of size 350x350x50mm reinforced with 8mm dia TMT steel bars @ 150 mm centre to centre in both direction and 10mm dia MS handle of suitable size, charchole or coke and salt in alternative layers, including necessary excavation and earth work in any type of soil, all as specified and shown in electrical plate no 3 of SSR part-1 complete all as specified and directed and tested on completion.
M&L for test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm, drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw including taking down old unserviceable complete all as specified and as directed.
S&F for recess mounted deep drawn size (2 ft x 2 ft) CRCA housing with higher power 36 Watt LED Seamless front frame with flat white height transmission acrylic cover complete all as specified and as directed. Make : Cat. No. DROPDOWNFLAT2x2 PLR 36 W LED 840S of Havells/Philips/Bajaj.
S&F for exhaust fan AC single phage 230/240 Volts of size 380mm sweep with louver complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core complete all as specified and as directed.
S&F for 25 Watt LED building security light new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING separate driver compartment with IP65 protection and impact resistance of IK07 complete all as specified and as directed. Make : Havells/Philips/Bajaj.
M&L for sand cushioning (dry) in trenches for protection of UG cables (below, above and around the UG cable laid in trenches) of 23cm spread thick ness and consolidated (punned) upto 18cm thickness, complete all as specified and as directed. Note : For the purpose of payment, punned thick-ness of sand cushioning only shall be measured and paid for.
S&F for sub-class B brick, well burnt, laid breadth-wise along the axis of cable laid in trenches over sand cushion laid for UG Cable protectioncomplete all as specified and as directed.
M&L for 20 mm bore, steel tubes, galvanised, light grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed.
M/S Abhi Traders
M/s GANDHESWAR PHUKAN
M/S AUTOMOTIVE WORLD
R D Enterprises
M/s. R. K. Trading Company
Bimal Trading Company
STANDARD ELECTRIC WINDERS
FREEZCON
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .