Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.7 LAccepted-AOC | L1 | Accepted-AOC Accepted being lowest | |
| 2 | L2₹28.1 L+₹3.3 L (13.3%)Rejected-Finance | L2 | Rejected-Finance Rejected being other than lowest |
Tender Value
₹30.5 L
EMD Value
₹61,000
Closing Date
25 Jan 2020, 6:00 pmClosed
Lt Col Vipin Kumar Singh
GE (S) Ahmednagar, Military Engineer Services, Ahmednagar- 414002
PROVN OF GUARD ROOM WITH SENTRY POST FOR NFS BLDG, CEILING FANS AND WALL MOUNTED FAN FOR MH, EXHAUST FAN FOR OTM 169 MED REGT , GEYSORS FOR MALHOTRA ENCLAVE AND RO FOR SUPPLY PL ASC AND CONNECTED WORKS AT AURANGABAD UNDER GE (S) AHMEDNAGAR
2019_MES_306088_1
8670/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
AURANGABAD
Class D Cat a (i)
7 documents required · 7 mandatory
₹500
Garrison Engineer (South) Ahmednagar
₹61,000
Yes
30 Jan 2020
12 Dec 2019
27 Jan 2020
12 Dec 2019
25 Jan 2020
26 Dec 2019
12 Dec 2019 - 19 Dec 2019
Amount
Surface excavation in hard/dense soil n exc. 30 cm deep and averaging 15 cm and getting out complete all as specified and directed.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundations not exc 10 Sqm on plan and not exc 1.5m in depth in soft/llose soil and getting out all as specified.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundationsnot exc 10 Sqm on plan and not exc 1.5m in depth in hard/dense soil and getting out all as specified.
Excavation in post holes or similar holes, each not exveeding 0.5 Cu.M, getting out inn Soft/Loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance not exceeding 50 M and making good surface complete all as specified and directed.
Returning, filling including spreading, levelling watering and well ramming in layers not exc 25 cm as in soil complete all as specified and directed.
Removing excavated material (soil) to a distance n.exc 50 m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed.
Plain cement concrete 1:4:8, type D-2 (using 40mm graded crushed stone aggregate) as in foundations filling and mass concrete complete all as specified.
Hardcore of gauge not exc 63mm , deposited, spread and levelled in layers n exc 15 cm thick, watered and rolled / rammed to a true surface complete all as specified and directed.
Hardcore of gauge exc 63mm but n exc 100 mm, deposited, spread and levelled in layers n exc 15 cm thick, watered and rolled / rammed to a true surface complete all as specified and directed.
Moorum filling in floors or pavings, laid in layers n exc 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed.
Plain cement concrete in plinth courses, string courses lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as directed
Reinforced cement concrete M-25 (design mix) using 20 mm graded crushed stone aggregate as in foundations including rafts, footings, foundation beams, plinth beams, bases of columns etc. complete all as specified and directed by Engineer-in-Charge.
Reinforced cement concrete M-25 (design mix) using 20mm graded crushed stone aggregate as in Columns, pillars, piers, posts and struts etc. complete all as specified and directed by Engineer-in-Charge.
Reinforced cement concrete M-25 (design mix) using 20mm graded crushed stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5 m span etc. complete all as specified and directed by Engineer-in-Charge.
Reinforced cement concrete M-25 (design mix) using 20 mm graded crushed stone aggregate as in Chajjas etc. complete all as specified and directed by Engineer-in-Charge.
Reinforced cement concrete M-25 (design mix) using 20 mm graded crushed stone aggregate as in Slabs supported on walls, beams and columns in floors, roofs complete all as specified and directed by Engineer-in-Charge.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work vertical or to batter complete all as specified.
Formwork to sides of pillars, posts, struts, piers, columns etc. complete all as specified and directed by Engineer-in-Charge.
Formwork to sides and soffits of floor or roof beam, beam hauchings, girders, bressum-mers, lintels cantilevers, shelves including supports complete all as specified.
Formwork to chullah hoods, chajjas, troughs and similar items including edges including supports complete all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (horizontal or sloping) complete all as specified and directed.
TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia complete all as specified
TMT bars 5 mm dia and over upto and including 10mm dia in stirrups, spacers and binders and binding with and including mild steel wire(annealed) not less than 0.90mm dia as in stirrups, complete all as specified
Brick work with sub class ‘B’ bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified and directed.
Precast cement concrete solid block masonry using solid block of grade C-5 (1:5:8) exc 10cm in width, built in CM 1:6 completeall as specified and direted.
Rendering 15mm thick in CM 1:4 on other than fair face of brick work or concrete surfaces complete all as specified and as directed by Engr-in-charge
Rendering 15mm thick in CM 1:6 on other than fair face of brick work surfaces of wall, ceiling or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed by Engr-in-charge
Rendering 05 mm thick in CM 1:3 on other than fair face of soffits of brick work or ceiling of slabs etc complete all as specified and as directed by Engineer-in-charge
2nd class soft wood (kail) scantling in unframed work fixed clean sawn etc complete all as specified and directed by Engineer-in-Charge.
2nd class soft wood, plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed by Engineer-in-charge.
2nd class hard wood, plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed by Engineer-in-charge
25 mm thick 2nd class soft wood (kail) plain, framed, panelled door shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of 12mm thick veneered particle board medium density, wood particle board with commercial face veneers complete all as specified and directed.
35 mm thick 2nd class hard wood (kail) plain, framed, panelled door shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of 12mm thick veneered particle board medium density, wood particle board with commercial face veneers, complete all as specified and as directed by Engineer-in-charge
30 mm thick second class hard wood (Kail) Glazed and Skelton shutters, open rebated and prepared to receive glass, gauge etc ( with out sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass etc. size of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (b) supplied and fitted to chowkats complete all as specified and directed and as directed by Engineer-in-charge.
12 mm thick Plywood, grade BWR, type BB, fixed with screws to timber frame work complete all as specified and directed by Engr-In-Charge.
3 mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane etc. complete all as specified and as directed by Engineer-in-charge.
Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and as directed by Engineer-in-charge.
Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC 'C channel having a PVC sheet strip of 20mm width shirk inside with solvent cement for stiles and plan colour PVC sheets for top rail, lock rai & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and as directed by Engineer-in-charge.
Mild steel barrel tower bolt, stove enamelled black, with bright bolt of 150 mm long complete all as specified and directed.
Mild steel barrel tower bolt stove enamelled black, with bright bolt of 100mm long complete all as specified and directed.
Mild steel sliding door bolts, stove enameled black with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolts plate and two on staple plate, 250mm long, all as specified.
Butt hinges, medium weight, cold rolled mild steel, 100mm long and fixed complete all as specified and as directed by Engineer-in-charge
Butt hinges, medium weight, cold rolled mild steel, 75 mm long and fixed complete all as specified and as directed by Engineer-in-charge
Mild steel pressed handles, oval type, stove enamelled black, 150 mm size, complete all as specified and directed.
Mild steel pressed handles, oval type, stove enamelled black, 100 mm size, complete all as specified and directed.
Plain cement concrete 1:4:8, type D-2 (using 40mm graded crushed stone aggregate), 75 mm thick as in sub base of floors including form work where required complete all as specified and directed.
100 mm thick PCC 1:2:4, type B-2 (by using 40 mm graded aggregate) as in bed blocks, coping etc. including form work etc complete all as specified and as directed by Engr-in-charge.
Forming 12 mm thick Expansion joints filled 100mm thick of concrete slab filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade 'A' including cutting PCC slab where required complete all as specified and directed by Engr-in-Charge
100 mm thick PCC 1:3:6, type C-2 (by using 40mm graded aggregate) as in base/sub base of flooring etc complete all as specified and as directed by Engr-in-charge.
50 mm thick PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in plinth protection surfaces finished even and fair complete all as specified and as directed.
Preparation of newly plastered surface of walls and applying two coats of oil bound distemper over a coat of chalk whiting complete all as specified and as directed by Engineer-in-charge
Preparation of newly plastered ceiling surfaces and applying two coats of oil bound distemper over a coat of chalk whiting complete all as specified and as directed by Engr-in-charge
Preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and as directed by Engr-in-charge
Preparation of newly plastered surfaces of walls and applying three coats of white wash complete all as specified and as directed by Engr-in-charge
Preparation on new wood or wood based surfaces of any description exc 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and as directed by Engr-in-charge
Steel ventilators, fixed type, with glazing bars etc complete all as specified and as directed by Engr-in-charge
Mild steel flat iron as in hold fasts and similar small articles fixed to chowkats, conforming Fe-290 Gde E-165, complete all as specified and directed by Engineer-in-Charge.
Framed bracket of angles or tees with web and flange cut to shape drilled and countersunk for screw including bending and welding angles as necessory gusset plates, riveting etc, in exc 10 kg each brackets conformining to Fe 410-0 or Fe 310-0 bracket over 10 Kg each to be measured under structural steel) complete all as specified and directed.
Rolled Mild steel Plates (plain or Chequred) channels, square cut or notched, forming holes, with riveted, bolted or welded attachment confirming to Fe 410 - O or Fe 310 - O complete all as specified and directed.
Mild steel work in tubular trusses and tubular posts including special shaped washers etc., complete using but welded. Tubes confirming to IS 1161-1979 graded St 240 with one shop coat of zinc chromate primer paint complete all as specified and directed.
Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strenght of 550 Mpa as in roof covfering/cladding to wall, fixed with self tapping screws etc completed all as specified and directed by Engr-in-Charge.
Preparation on new steel surfaces of any description exc 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed by Engr-in-charge
15 mm bore medium grade galvanised steel water tubing with all fittings and fixed complete to wall and ceiling or laid in floors etc. complete all as specified and as directed by Engr-in-charge
20 mm bore medium grade galvanised steel water tubing with all fittings and fixed complete to wall and ceiling or laid in floors etc. complete all as specified and as directed by Engr-in-charge
Rotational moulded polyethylene 1000 ltr capacity water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as described in SSR Part I and complete all as specified and as directed by Engr-in-charge
15 mm bore bib taps, cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed etc. complete all as specified and as directed by Engr-in-charge
Pillar taps 15 mm bore cast copper alloy with capstan heads, chromium plated, screwed down high pressure, with or without letted 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed etc. complete all as specified and as directed by Engr-in-charge
Stop valve 15 mm bore cast copper alloy, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed etc. complete all as specified and as directed by Engr-in-charge
20 mm bore globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed by Engr-in-charge
PVC connection 15 mm bore, 450 mm long including brass check nuts at both ends screwed for iron pipe complete all as specified and as directed by Engr-in-charge
75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in floors complete all as specified and as directed by Engr-in-charge.
110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in floors complete all as specified and as directed by Engr-in-charge
110 mm bore PVC (SWR) bends, any radius, fixed and jointed complete all as specified and as directed by Engr-in-charge
Slotted vent cowl 100 mm bore, fixed in position complete all as specified and as directed by Engr-in-charge
75 mm dia outlet PVC (SWR) floor trap, plain with grating including jointing with solvent cement and fixed in position including PCC 1:2:4, type B1, complete all as specified and as directed by Engr-in-charge
PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement and PCC 1:2:4, type B1, complete all as specified and as directed by Engr-in-charge
Soap nitch fixed in position with chromium plated brass screws complete all as specified and as directed by Engr-in-charge
Aluminium anodised Tubular towel rail, 20 mm dia, D type, 60 cm long between flanges fixed with screws and gutties complete all as specified and as directed by Engr-in-charge
PVC waste pipe 32 mm bore PVC flexible with plastic check nut for WHB and sink complete all as specified and as directed by Engr-in-charge
Wash basins, Vitreous China (flat back or angle back type) of size 550 mm x 400 mm, including cutting for and pinning in ends of brackets or erecting stand including waste coupling CP and waste / vent pipe and brackets but excluding taps, complete all as specified & directed.
Water Closet vitreous China squatting pan, 'Orissa' pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) complete all as specified and as directed by Engr-in-charge
Vitreous China Urinal, Half stall type, (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement; including provoding and fixing 5 ltr capacity automatic PVC flushing cistern with brackets, flush pipe, grating and Union for discharge pipe complete all as specified and as directed by Engr-in-charge
PVC valveless, syphonic action type, flushing cistern 10 litres capacity low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and as directed by Engr-in-charge
20 mm bore aluminium powder coated curtain rods for pelmets etc, fixed in position complete all as specified and as directed by Engr-in-charge.
Vitrified Ceramic tiles (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15 mm thick cement screed bedding in CM 1:4 complete all as specified and as directed by Engr-in-charge.
Non - skid Ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 15 mm thick cement screed bedding in CM 1:4 complete all as specified and as directed by Engr-in-charge
Glazed Ceramic coloured tiles in vertical surface (skirting/dado), size of tiles 450 mm x 350 mm x 7 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10 mm thick cement plaster backing in CM 1:4 complete all as specified and as directed by Engr-in-charge
20-25mm thick Machine cut kota stone slab flooring laid over and including 15 mm thick cement screed bedding in CM 1:6, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete complete all as specified and as directed by Engr-in-charge
20-25 mm thick Machine cut kota stone on vertical surface such as skirting/ dado laid over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including 10 mm thick cement screed backing in CM 1:4 complete all as specified and as directed by Engr-in-charge
APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3 mm thick reinforced with polyster non woven fabric (wt. not less than 150 gms/sqm) laid on primed surfaces by forced application complete all as specified and diercted.
Septic tank including inlet & outlet chambers for 25 users, brick construction (with top of slab at ground level) including necessary excavation and earth work in any type of soil and disposal of surplus soil to a distance not exc 50 m, bricks work in sub class 'B' bricks built in CM (1:4), RCC as in slab including RCC manhole covers factory made ISI marked conforming to IS 12592 with angle iron frame 100 mm bore cast iron sand cast vent pipes with cast iron cowls complete all as specified and shown in drawing No. CEPZ/88/TD/17M dated 01 Oct 88, sheet 1/4 to 4/4
Soakage well 1.20 m dia and 3.00 m deep below inlet pipe level (depth from inlet pipe to ground level 45 cm) including excavation and earth work in any type of soil filled with brick bats, RCC slab with RCC manhole cover factory made ISI marked conforming to IS 12592 fixed in angle iron frame, SWG single junction inlet filling around slab in slopes and disposal of surplus soils to a distance exceeding 50 m but not exceeding 100m complete all as specified and shown in drawing no. CEPZ/2004/TD/8, sheet No. 1/1 dated 30 Jun 2004.
150 MM internal dia reinforced cement concrete pipes of approved make class NP2, laid and joined in cement mortar with collars (PCC shall be measured and paid for seperately under respective item) complete all as specified and directed.
PCC 1:4:8 type D-2, using 40 mm graded stone aggregate as in concrete bed to drain pipes any type of 150 mm internal dia including packing under and hunching against the sides of the pipes after they are laid & tested complete all as specified and directed.
Chequered cement concrete tiles 20 cm x 20 cm x 25 mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigment over and including 20 mm thick screed bed or beding in CM 1:6 etc. complete all as specified and as directed by Engr-in-charge.
25 mm bore medium grade galvanised steel water tubing with all fittings and fixed complete to wall and ceiling or laid in floors etc. complete all as specified and as directed by Engr-in-charge
50 mm bore medium grade galvanised steel water tubing with all fittings and fixed complete to wall and ceiling or laid in floors etc. complete all as specified and as directed by Engr-in-charge
25 mm bore globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed by Engr-in-charge
50 mm bore globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed by Engr-in-charge
Cutting existing water main 100 mm bore and tapping with provn of specials and joints as required including necessary excavation & earth work and making good the surface/road as per existing complete all as specified and directed.
Construction of valve chamber of size 900 mm x 900 mm x1000 mm including unserviceable rusted MS cover complete without distrubing the existing pipe lines valves and constructing new valve chamber including necessary earth work in any type of soil ,PCC 1:3:6 in base concrete 100 mm thick ,brick work in CM (1:6) with 10 mm thick plaster internally and 15 mm thick externally in CM (1:4) ,6 mm thick MS sheet cover with hinges and locking arrangements fixed to angle iron frame made out of 50 mm x 50 mm x 6 mm MS angle complete with two coats of synthetic enamelled paint over a coat of red oxide on all steel work and three coats of white washing on plastered surface of valve chamber complete all as specified and directed.
Point wiring with 1.5 Sqmm (22/0.30mm) PVC insulated and unsheathed multistranded copper conductor cable, 1100 volts grade, ISI marked, FR type drawn through and including PVC casing and caping (ISI marked) and its accessories such as Tee, elbow, jointer, elbow corner etc. fixed on surface of walls, coloumns/ beams alongwith 1.5 Sqmm (nominal area) copper conductor cable (multistranded) PVC insulated and unsheathed as earth wire connected to common earth dolly at one end and metalic bodies of luminaire/ fan at other end including PVC folding boards or wooden boards with sunmica top for mounting switches, sockets, fan regulators, accessories etc for one light/fan point controlled by one, one way switch complete all as specified and directed.
All as per serial item no. 103 here-in-before but for One 5 Amp 5 pin socket outlet point on independent including earth wire complete all as specified and directed.
All as per serial item no. 103 here-in-before but for One 5 Amp 5 pin socket outlet point on same including earth wire complete all as specified and directed.
All as per ser item No. 103 here-in-before but point wiring with 4.0 Sqmm (36/0.30mm) PVC copper stranded cable FRLS type for one 15 Amp 6 pin socket outlet point including PVC cable 4 Sqmm FRLS type copper stranded conductor as earth wire & connected to commen earth & earth terminals including PVC/wooden folding boards for mounting purposes complete all as specified and directed.
Switch piano flush button single pole one way 5 amps,230 volts, fixed complete all as specified and directed.
Switch piano flush button single pole one way 15 amps, 230 volts fixed, complete all as specified and directed.
Socket outlet 3 pin, 5 Amp multipurpose flush type, fixed complete all as specified and directed.
Socket outlet 2 in 1, 3 pin, 5 & 15 Amp flush type, fixed complete all as specified and directed.
Ceiling rose surface bakelite 65 x 50 mm, 2 to 3 terminals, polycarbonate / PVC / isolated body, fixed complete all as specified and directed.
LED ultra slim edelit downlighter 18W, 220 V AC white powder coated Aluminium housing recess mounting of Make Surya Cat Part No G-Panel (Rd)12W or equivalent complete all as specified and directed.
MCB SPN 32 Amps, 10 KA single pole AC 230 volts complete all as specified and directed.
Sheet metal enclosures, factory made, SPN 8 way double door 240 v with 200 Amps rated bus bar for DB,s suitable for having MCB / Isolator flush with wall complete all as specified and directed..
MCB SP, 6 to 32 Amps 10 KA single pole AC 230 volts, fixed in repairs complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 600 X 600 X 6 mm thick, buried directly in ground earth pit not less than 2.25 meter in depth with top edge of the plate not less than 1.5 meter below normal ground level, connected to galvanized iron wire 4 mm dia earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron as required, including watering arrangement with 20 mm bore medium grade GI tubing, funnel and wire mesh, PCC chamber with CI frame and cover , necessary excavation, returning filling and removal of surplus soil, filling of charcoal and salt in alternate layer complete all as shown in plate No 5 of MES Schedule Part I including testing complete all as specified and directed.
Fan regulator rotary stepped type electronic flush type, AC 240 V, fixed complete all as specified and directed.
Submain wirng with two single core PVC insulated unsheathed, multistranded flexible copper conductor 1100Volts grade cables 2.5 Sqmm drawn through in and including rigid PVC heavy duty surface conduits including 2.5 Sqmm 1100 Volts grade PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified & directed.
Submain wirng with two single core PVC insulated unsheathed, multistranded flexible copper conductor 1100Volts grade cables 4 Sqmm drawn through in and including rigid PVC heavy duty surface conduits including 4 Sqmm 1100 Volts grade PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified & directed.
Exhaust fans AC single phase 230/ 240 V of size 300 mm sweep metallic body copper wound with self opening and closing louvers for protection from birds and rain water , fixing by means of rugged bolts, nuts and washers etc. and foundation brackets, making connection from ceiling rose to fan with and including 1.5 sqmm conductor cable including making hole in existing stone masonary/ brick wall complete and testing at site complete all as specified and directed.
LT XLPE insulated, PVC sheathed,galvanized steel strip or wire armoured, heavy duty, electric cable with aluminium conductor of size 10 sqmm 2 core,1100 volts grade conforming to relevant IS, ISI marked, laid in trenches / wall / floor/ poles etc ,complete including making connection using suitable size aluminium lugs including testing and commissioning complete all as specified and directed by Engineer-in-charge. (Excavation/earth work, sand cushioning and cable covers shall be measured and paid for separately under respective item).
Sand cushioning to under ground cable with a layer of fine river sand 8 cms thick before laying of cables and 15 cms thick after laying of cable in trenches complete all as specified and directed.(For payment prooned down thickness of 18 cm shall be considered)
Unreinforced factory made precast concrete cable protection covers class LV type-2, flat, of size 250 mm x 150 mm x 40mm, ISI marked, laid complete all as specified and directed.
High power LED bldg street light fittings 35/36W including service bracket and clamps and necessary items including making connection with suitable size copper conductor cable complete all as specified and directed.
Ceiling fan with all accessories 230 V,1200 mm sweep, BEE 5 star rated including making connection from ceiling rose to fan with and including 1.5 sqmm copper conductor cable complete all as specified and directed.
Heavy duty metalic body wall mounted air circulating fan 300 mm sweep with regulating switch complete all as specified and directed.
M/s Jai Sai Construction
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .